CAPTAIN CROFTON

CAPTAIN CROFTON is a 1978 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in January 2020, along with 14 deficiencies.

Records from 2016 to 2020. Most recent: inspection, 24 January 2020.

Built
1978
Last inspected
24 January 2020
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 January 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH8056
Flag
UNITED STATES
Maury page id
psix-49741

Documentation record

Registered dimensions (L × B × D)38.8 ft × 14.0 ft × 5.6 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTSMOUTH, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

7 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

24 January 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6895471
24 January 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6608961
22 January 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6339818
31 October 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6298282
24 October 2017 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6290999
26 October 2016 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6028673
2 March 2016 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5824276

Deficiency record · 14

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2019 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous rotating machinery. Observed rotating belt exposed on starboard maine engine. Install cover/guard to satisfaction of attending Coast Guard Marine Inspector. (46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
Resolution: Installed a guard on rotating belt on starboard engine.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 January 2019 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Bilge high level alarm for cabin space was inoperable. (46 CFR 182.530)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
Resolution: Both audible and visual alarm tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2019 Resolved
The owner, managing operator, or a qualified servicing facility shall conduct inspections and tests on portable fire extinguishers. Current/past servicing certificates were not present during inspection. Vessel owner/representative shall provide fire servicing certificates for portable fire extinguishers to the satisfaction of the attending Coast Guard Marine Inspector. (46 CFR 176.810(b)(1))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 28 January 2019
Resolution: Vessel representative emailed a copy of the BFPE certificate of inspection of all portable fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2019 Resolved
Each ring life buoy on a vessel must not be permanently secured in any way. Ring life buoy line was attached to the vessel. (46 CFR 180.70(b)(4))
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
Resolution: Found ring life buoy not permanently attached to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2019 Resolved
Each floating water light attached to ring life buoy must be attached to the lanyard with a corrosion-resistant clip. The floating water light was permanently attached to the ring life buoy. (46 CFR 180.70(d)(3))
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
Resolution: Floating water light attached with corrosion-resistant clip around the body of ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2019 Resolved
The name of the vessel must be marked of painted on each ring life buoy. Name of vessel was fading/peeling off of ring life buoy. (46 CFR 185.604(b))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
Resolution: New name stickers were placed on ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 January 2019 Resolved
Life float is required to have Type II retro-reflective tape. The top life float on board the vessel had sun-damaged retro-reflective tape and needs to be replaced. (IMO Resolution A.658(16))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 14 February 2019
Resolution: Appropriate SOLAS Type II reflective tape replaced on ring life buoy.
Engineering › Bilge Water Management System › Pump
Issued 24 October 2017 Resolved
Cabin Bilge unable to dewater, vessel needs to demonstrate function of bilge in that space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2017
Resolved 31 October 2017
Resolution: Witnessed operational test of the vessel's bilge system.
Stability › Watertight Integrity › General
Issued 24 October 2017 Resolved
Window at Operating Station cracked, repair for adequate strength and view. Cite 177.1030
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 31 October 2017
Resolution: Vessel replaced starboard window at operating station.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 March 2016 Resolved
Light fixtures overhead in cabin were smoking, fire hazard. Replace to satification of the Marine Inspector. OLD T 46CFR183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 10 March 2016
Resolution: Light fixtures overhead in cabin were replaced in kind; all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 March 2016 Resolved
FCC Safety Certificate is expired, vessel is restricted to 1000ft from shore until renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 10 March 2016
Resolution: FCC Safety Certificate was renewed; all sat.
Communications › Radio Communications › EPIRB
Issued 2 March 2016 Resolved
Hydrostatic release on EPIRB is expired, vessel is restricted to 3nm from shore until replaced.
Condition: Invalid
Due 16 March 2016
Resolved 10 March 2016
Resolution: Replaced with new Hydrostatic release; all sat.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 March 2016 Resolved
Indicator light for steering compartment high water level is inoperable. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 10 March 2016
Resolution: Repaired Indicator light for steering compartment high water level; all sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 March 2016 Resolved
Conduct man overboard and fire drills in the presence of a marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2016
Resolved 10 March 2016
Resolution: Conducted man overboard and fire drills; all sat.

Ownership record