ARANSAS SEAHORSE is a 1978 offshore supply vessel. The Coast Guard has recorded 12 inspections since 1982, most recently in January 1993, along with 5 deficiencies.
Records from 1982 to 1993. Most recent: inspection, 11 January 1993.
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for ARANSAS SEAHORSE (ON 594760), retrieved 18 September 2026. mauryrecords.com/v/psix-49745.html
Documentation record
Tonnage as PSIX records it167 - Regulatory (Subpart C or D), Net Ton 246 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
11 January 1993Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 665629
21 September 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1315648
13 January 1987COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328442
13 January 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328447
13 January 1987COI Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328607
12 January 1987COI Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006526
12 January 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020897
12 January 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024791
12 January 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319691
12 January 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328617
18 December 1984Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1283161
22 June 1982Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967715
SUBMIT DOCUMENTATION THAT BOTH LIFERAFTS HAVE BEEN SERVICED BY A COAST GUARD APPROVED FACILITY AND INSTALLED BACK ABOARD VESSEL NO LATER THAN 31 MARCH 1987 TO [name withheld] WERE SERVICED LOCALLY SEP 86 BY A NON-APPROVED FACILITY.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Accommodation/Occupational Safety
Issued 12 January 1987Resolved
REINSTALL FAN AND SCREENING ON GAYLORD HOOD.
Condition: Unknown
Due 31 March 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1987Resolved
REPAIR ANNUNCIATOR ALARM PANEL FOR MAIN ENGINES AND GENERATORS.
Condition: Unknown
Due 30 June 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1987Resolved
CROP OUT OT SOUND METAL AND RENEW IN KIND THE DISCHARGE LINE OF BILGE- BALLAST PUMP IN WAY OF THE TEMPORARY REPAIR IN BEND.
Condition: Unknown
Due 30 June 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1987Resolved
CLEAN BILGES OF ENGINEROOM AND ALLEY TO REMOVE OIL AND SLUDGE.
Condition: Unknown
Due 30 June 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.