MAURY USCG vessel records
← All vessels

HUZZAH

Built
1999
Last inspected
18 April 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 April 2023
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG4084
497566
Flag
UNITED STATES
Maury page id
psix-497566

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.0 ft × 4.5 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTSS FABRICATING INC & SKIPPERLINER INDUS INC · LA CROSSE, WI, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Net Ton
22 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

18 April 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7665841
9 March 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7152559
7 November 2019 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6846879
24 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841006
28 June 2019 Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6728743
3 October 2018 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6554088
31 May 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6428842
1 August 2017 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6221491
29 September 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6012082
11 May 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5879644

Deficiency record · 11

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019 Resolved
Batteries in engine room not secured. Secure all 3 battery banks in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 12 December 2019
Resolution: Inspected battery installation, SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 November 2019 Resolved
Electric bilge pump discharge hull penetrations have no stop valves. Install positive stop valves as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 6 December 2019
Resolution: Positive action valves installed at each bilge pump hull penetration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019 Resolved
Junction box on starboard engine missing cover. Install cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Secured junction box cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 November 2019 Resolved
Starboard engine jacket water temperature gage inoperable. Provide temp gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 22 November 2019
Resolution: Installed and tested stbd engine jacke water temperature gage, sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 November 2019 Resolved
Vessel anchor size not suitable for vessel size. Provide anchor suitable for the vessel size and the water it operates in.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 6 December 2019
Resolution: Vessel anchor, chain, line and shackles replaced with adequately sized equipment.
Construction/Loadline › Hull › Stiffener
Issued 31 May 2018 Resolved
Renew longitudinal stiffner support brackets in forward void, port side as marked; prior to credit hull exam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: Installed new gussets on all marked frames on port forepeak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2018 Resolved
Reconnect bonding wire on starboard outboard drive; prior to credit hull exam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: Reconnected bonding wire on starboard outdrive.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 August 2017 Resolved
Bundle and secure wires going to the drive tilt in the lazarette
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Vessel rep. bundled wires.
Stability › Watertight Integrity › General
Issued 1 August 2017 Resolved
Replace watertight gasket on the forward compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Vessel rep. replaced gasket on hatch in fwd compartment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 August 2017 Resolved
Replace the bracket for the B-I fire extinguisher in the pilot house. Install approved type bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Vessel rep. installed bracket for fire extingguisher.
Construction/Loadline › Structures › End Bulkhead
Issued 1 August 2017 Resolved
Crop and renew wasted bracket in the forward compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Vessel rep. installed bracket in fwd compartment.

Ownership record