Records from 2002 to 2026. Most recent: inspection, 27 April 2026.
Inspection history · 20
27 April 2026
Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8357135
1 December 2025
Internal Structural Exam · Vessel Attendance · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8275579
12 March 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8092871
27 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7869422
25 October 2023
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7814106
8 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7650356
7 March 2022
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7405171
8 December 2021
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7364713
20 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7179718
12 May 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6938905
27 November 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6863954
14 May 2019
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6704752
20 June 2018
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6468165
8 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6404878
1 May 2018
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6422832
4 December 2017
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6317610
29 September 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6277899
17 August 2017
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6247096
30 March 2017
Deficiency Check · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6113667
26 May 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5885794
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 March 2025
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire explosion, machinery failure and personnel injury. The starboard generator was leaking diesel fuel. Repair generator. 46CFR182.100
Action required: 10 - Deficiency Rectified
Due 12 March 2025
Resolved 12 March 2025
Resolution: Fuel rack removed, repaired, and reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 March 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. No guard was installed in way of the rotating machinery on the starboard generator. Install guard. 46CFR177.35-15
Action required: 10 - Deficiency Rectified
Due 12 March 2025
Resolved 12 March 2025
Resolution: Installed guard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Only 140 life jackets were found to be in a serviceable condition and/or approved under the appropriate approval series. Replace lifejackets with lifejackets approved under the approval series' found in 46CFR180.71. The vessel is limited to carrying 140 total person on board.
Action required: 705 - Other - as specified
Due 12 March 2025
Resolved 13 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 March 2025
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. The required lights for the survival craft were stored under the mast structure possibly preventing the survival craft from floating free. Move lights so the craft and all provisions are float free.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2025
Resolved 12 March 2025
Resolution: Provided pictures of relocated lights
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2025
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type, a space containing propulsion machinery and a space containing an internal combustion engine of more than 50 hp. The engineroom was not fitted with an alarm system. Install alarm system in the engineroom such that the actuation of the alarm results in both audible and visual alarms in all areas required by 46CFR181.405(c).
46CFR181.405(c); 181.450; 175.110(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 25 March 2025
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 March 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have donning instructions posted. Post donning instructions in conspicuous places for each type of lifejacket on board.
46CFR185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 25 March 2025
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. No emergency instructions mounted at the operating station. Mount emergency instruction at the operating station. Recommended format can be found at 46CFR185.512.
46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 25 March 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2022
Resolved
Inspect vessel in accordance with 46 CFR 182.115. Inspect bilge pumping arrangements in accordance with old T 46 CFR 182.25. Installed bilge system would not dewater all spaces. Vessel limited to 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 March 2022
Resolution: Video evidence received showing satisfactory operation of bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 March 2022
Resolved
Inspect life saving arrangements in accordance with 46 CFR 176.808. Life floats were not satisfactorily rigged for manual deployment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 21 March 2022
Resolution: Life floats are properly rigged.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 7 March 2022
Resolved
Inspect lifesaving arrangements in accordance with 46 CFR 176.808. Provide satisfactory means to recover person from the water.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 21 March 2022
Resolution: Means provided to recover person form the water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 March 2022
Resolved
Inspect vessel in accordance with 46 CFR 183.115. Wiring methods must meet old T 46 CFR 183.10-20. Extension cords were present in the galley and bridge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 21 March 2022
Resolution: Extension cords were present in the galley and bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2022
Resolved
Inspect vessel in accordance with 46 CFR 182.115. Inspect bilge system in accordance with old T 46 CFR 182.25-5(d). Forepeak bilge suction valve was not operable from above the main deck. To be corrected by completion of Dec 2023 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 March 2023
Resolution: Witnessed the satisfactory repair of the forepeak bilge suction valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
Unable to verify life jacket lights expiration date. Vessels route is reduced to only coastwise operations until new lights can be provided for each life jacket onboard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 June 2021
Resolution: New lights provided and affixed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2020
Resolved
21 Adult and 02 child life jackets taken out of service due to poor condition. Provide proof of replacement life jackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Owner provided proof of all new replacemnt life jackets, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2019
Resolved
Make proper electrical splice for bilge wires in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 19 December 2019
Resolution: Proper splicing crimps and heat shrink tape used, ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2019
Resolved
Crop and renew wasted bilge piping in the forward bow void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 26 May 2019
Resolution: Renewed bilge piping, tested all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2019
Resolved
Properly install electrical conduit on the port main deck overhead,
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 26 May 2019
Resolution: Repaired and installed electrical conduit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019
Resolved
Adjust the starboard engine room air dampner to close properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 26 May 2019
Resolution: Adjusted dampner and tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2019
Resolved
Replace existing plastic fire hose nozzles.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 26 May 2019
Resolution: Replaced plastic fire hose nozzles with approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2019
Resolved
03 Adult and 02 Child life jackets were found unserviceable, replace with approved type of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 26 May 2019
Resolution: Replaced 05 Life jackets with approved type.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2019
Resolved
Provide proof of spanner wrenches installed at each fire hose station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 26 May 2019
Resolution: Provided proof of new installed spanner wrenches at each fire hose station.
Engineering › Bilge Water Management System › Valve
Issued 30 March 2017
Resolved
Remove and clean check valve in bilge system
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 April 2017
Resolution: Vessel removed and cleaned check valves.
Engineering › Bilge Water Management System › Piping
Issued 30 March 2017
Resolved
Prove proper operation of fwd bilge suction. Vessel required to maintain portable bilge pump.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 April 2017
Resolution: Vessel conducted sat test of fwd bilge suction
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 30 March 2017
Resolved
Tighten / add packing on port shaft
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 April 2017
Resolution: Vessel tighten packing
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 30 March 2017
Resolved
Repair port exhaust water leak
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 April 2017
Resolution: Vessel repaired exhaust leak
Lifesaving › Lifefloat › Float-free Link
Issued 30 March 2017
Resolved
Install proper size lifefloat weaklink and painter cage
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 April 2017
Resolution: Vessel installed proper painter cage and weaklink