Records from 2005 to 2026. Most recent: inspection, 1 May 2026.
Inspection history · 78
1 May 2026
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8359373
17 February 2026
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8311983
17 October 2025
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8256504
1 October 2025
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8245358
23 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8239411
25 June 2025
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8165598
8 May 2025
Security Breach
Type not classified · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8131983
11 April 2025
In-Service Inspection · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8109995
3 December 2024
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8040253
10 October 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8017184
20 September 2024
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8003218
27 June 2024
Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7936770
6 March 2024
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7871658
23 February 2024
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7875916
29 January 2024
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7859297
29 November 2023
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7829817
26 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7814795
17 October 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7806904
10 October 2023
Security Breach
Type not classified · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7830655
27 September 2023
Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7795362
5 July 2023
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7733858
17 May 2023
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7691156
21 April 2023
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7666675
6 December 2022
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7598916
8 September 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536210
19 July 2022
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7516981
24 March 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417387
1 December 2021
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7358356
14 October 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7331818
26 July 2021
Special Consideration · Appeal
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7268328
15 July 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7258001
14 July 2021
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7255687
6 July 2021
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7249818
10 May 2021
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7191727
30 April 2021
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7186296
24 April 2021
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7212179
30 March 2021
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7164812
2 December 2020
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7096749
24 October 2020
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7096897
3 September 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7048628
19 May 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6955761
6 April 2020
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935983
6 January 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6883489
4 December 2019
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6865281
24 October 2019
Deadweight Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6831916
18 October 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6849558
10 October 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6831881
10 July 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6744969
30 May 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6883531
22 May 2019
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6690596
26 February 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6632331
22 January 2019
Damage Survey · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6614468
27 November 2018
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6587316
9 October 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6557481
26 September 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6548066
27 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6524612
21 June 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6452364
16 April 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392213
12 April 2018
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6390631
11 April 2018
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6389800
10 April 2018
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6389049
7 April 2018
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6388691
26 March 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6379052
9 November 2017
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6303917
8 September 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6262677
10 July 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6299411
12 June 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6173948
27 April 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6133889
8 March 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6101221
28 November 2016
MTSA Verification · Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6048614
19 October 2016
Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6026234
5 October 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6016811
28 June 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5922188
6 May 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5870288
26 April 2016
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5863823
25 March 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5840387
3 February 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5809003
20 January 2016
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5800173
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 1 October 2025
Resolved
Remove excessive oil from the E/R Bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 1 November 2025
Resolution: Evidence def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2025
Resolved
Investigate and repair oil leak on stbd M/E in way of the govenor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2025
Resolved 1 November 2025
Resolution: Oil leaks has been fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2025
Resolved
Repair oil leak on the #1 SSDG in way of the lube oil cooler.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2025
Resolved 1 November 2025
Resolution: Oil leak has been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 June 2025
Resolved
REPAIR STAIRTOWER DOOR ON STBD UPPER CAR RAMP SO THAT IT CLOSES PROPERLY.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 25 June 2025
Resolution: CORRECTED ON THE SPOT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2025
Resolved
REPLACE PORTABLE FIRE EXTINGUISER AT STATION 11.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 July 2025
Resolved 25 June 2025
Resolution: CORRECTED ON THE SPOT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 June 2025
Resolved
E/R to MSD space WTD failed to operate. They hydraulic piston seal failed. The door has been manually closed. The WTD must remain closed until repairs are completed and tested to the satisfaction of the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2025
Resolved 16 July 2025
Resolution: O/O provided service report that included attestment to the satisfactory testing of the opening and closing of door locally and remotely.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2024
Resolved
Repair/replace damaged starboard side reduction gear and prove proper operation in the presence of a USCG Marine Inspector prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 10 April 2025
Resolution: Repaired
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 December 2024
Resolved
Conduct man overboard, fire, security and anchor drill in the presence of a USCG Marine Inspector prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 17 April 2025
Resolution: Drills completed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2024
Resolved
Conduct sprinkler test on vehicle decks in the presence of a USCG Marine Inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 17 April 2025
Resolution: Sprinkler test completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2024
Resolved
Unable to complete STBD MDE PTSP's due to reduction gear failure. Complete PTSP's prior to carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 10 April 2025
Resolution: repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 September 2024
Resolved
Repack stuffing tubes on aft upper deck electrical wiring to A/C units.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2024
Resolved 20 September 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2024
Resolved
STBD side aft door on accommodation deck is not closing properly/bottom of door is rubbing on deck preventing door from shutting on its own. Prove door operates properly.
Action required: 705 - Other - as specified
Due 1 November 2024
Resolved 11 April 2025
Resolution: Door closes properly
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 September 2024
Resolved
Remount speaker on the port stack.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2024
Resolved 2 October 2024
Resolution: speaker was remounted
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 September 2024
Resolved
Replace cage on lighting globe in galley walk-in cooler.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2024
Resolved 2 October 2024
Resolution: Cage was installed
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 June 2024
Resolved
Repair/replace dist panel door in galley.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 8 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2024
Resolved
Repair sprinkler head bracket stbd side under ramp midship
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 8 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 March 2024
Resolved
Provide evidence that the main fire pump operates as designed and reaches 50 or above PSI
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 21 March 2024
Resolution: repaired
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 March 2024
Resolved
Sprinkler pumps that can be used to provide required water PSI were not readily available.
Action required: 10 - Deficiency Rectified
Due 15 March 2024
Resolved 6 March 2024
Resolution: Corrected before we departed ferry
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2024
Resolved
STBD Main Diesel Engine coolant deliver pump leaking. Provide evidence that the pump has been repaired/replaced to stop the leak
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 27 June 2024
Resolution: MI attended vessel and witnessed the repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2024
Resolved
L/O pressure switch above the STBD Main Diesel Engine coolant pump is leaking. Provide evidence that the pump has been repaired/replaced to stop the leak.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 21 March 2024
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 November 2023
Resolved
Replace worn fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 12 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 November 2023
Resolved
Remove paint from waterlight.
Action required: 10 - Deficiency Rectified
Due 14 December 2023
Resolved 12 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 November 2023
Resolved
Prove proper operation of smoke detector D18
Parts are backordered until January.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2024
Resolved 6 March 2024
Resolution: MI witnessed proper operation of detector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2023
Resolved
Prove proper operation of Low Lube Oil alarm.
Parts on order.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 January 2024
Resolved 8 July 2024
Resolution: MI witnessed engine tech test alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 April 2023
Resolved
Replace port engine tach on port bridge wing. Currently inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2023
Resolved 11 May 2023
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 April 2023
Resolved
Fire panel has error code z90 for several spaces. Clear code, test detectors, provide report.
This was cleared while on board.
Action required: 10 - Deficiency Rectified
Resolved 21 April 2023
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 April 2023
Resolved
The raw water inlet and discharge lines for #2 generator were found wasted IWO heat exchanger, make repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2023
Resolved 11 May 2023
Resolution: completed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023
Resolved
The wiring for stbd M/E exhaust temp sensors were found pulled from junction box. Return wires to junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2023
Resolved 11 May 2023
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2023
Resolved
Repair gasket on stbd M/E reduction gear cooler. Gasket found to be leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 11 May 2023
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 April 2023
Resolved
#2 generator high water temp sensor found inoperable during testing. Install new.
New sensor installed and tested sat, cleared while on board.
Action required: 10 - Deficiency Rectified
Resolved 21 April 2023
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022
Resolved
The STBD reduction gear cooling lines have 2 soft patches. Renew piping IWO soft patches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 18 May 2023
Resolution: Complete
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 6 December 2022
Resolved
Vessel is authorized for *PUMS on COI, however, the vessel is not fitted with an engineer assist alarm or dead man alarm. Vessel PUMS endorsement revoked, amending COI.
Action required: 10 - Deficiency Rectified
Resolved 6 December 2022
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 December 2022
Resolved
The alarm indicator for the "STBD main high oil" is out in ECR. Replace bulb.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 18 May 2023
Resolution: Completed.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 6 December 2022
Resolved
Complete the following tests at the 1st quarterly re-inspection:
Boiler automation tests
Control Air Receiver Relief Valve
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 December 2022
Resolved
Make repairs and prove proper operation of the #3 generator reverse power relay prior to operation.
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Completed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 December 2022
Resolved
Make repairs and prove proper operation to CO2 piping (for bow thruster siren). MI's witnessed leaking of CO2 from behind installed fire insulation boundary.
Action required: 10 - Deficiency Rectified
Resolved 6 December 2022
Resolution: Upon removal, found that a hole was drilled in an elbow to hold the framing in place for the insulation. This was repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2022
Resolved
Make repairs to fire door on stbd fwd main car deck (to stairwell). Wire re-inforced glass is cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2023
Resolved 21 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 December 2022
Resolved
Provide lithium ion (AA) batteries IAW floating electric waterlight instructions. MI's found alkaline batteries in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 8 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 December 2022
Resolved
Make updates to VRP with new employees name/contact info, and remove employees no longer in charge. MI's found that Mario is still listed in contacts and he no longer works at Bridgeport & Port Jeff Ferries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 8 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2021
Resolved
Doors in stairway enclosures and main vertical zone bulkheads shall be of the self-closing type. Fire doors from car decks do not latch closed. Adjust doors to self-close (some need handle adjustments, and some tension).
46 CCFR 72.05-25(b)(9)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 15 December 2021
Resolution: Doors adjusted and tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 December 2021
Resolved
Vessels manual fire alarm system stations must be of an approved type. The pull station located outside the crew space on aft starboard side was unable to be tested due to corrosion within the locking mechanism. Repair/replace pull station and test for proper functionality.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 15 December 2021
Resolution: New pull station installed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 December 2021
Resolved
Repair lighting in voids 5 & 7, currently not working.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 24 March 2022
Resolution: Lighting has been repaired or terminated. Because the lights are so high in the overhead replacement was difficult and will be fully restored at next drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2021
Resolved
Prove proper operation of #2 generator reverse power relay.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 15 December 2021
Resolution: #2 reverse power relay tested sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 December 2021
Resolved
Prove proper operation of port main engine shutdown for CO2 discharge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 24 March 2022
Resolution: engine shutdown operational.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 July 2021
Resolved
Fire Detectors must be located in all spaces except
those having little or no fire risk. While conducting a
quarterly re-inspection MI’s identified two heat
detectors (only 1 heat operational of 3) in the bow
thruster space and one heat detector in the steering
compartment that showed Z90 invalid reply on the fire
detection panel. MI’s conducted inspection of the heat
detectors and found them damaged and hanging from the
mounting bracket. Vessels crew could not say how long
they were like that but admitted they have been that way
for “a while”. This indicates the crew and company
management are not proactively managing the vessel.
Vessel to prove proper operation of heat detectors in
steering compartment and bow thruster space.
46 CFR 76.27-80(b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 July 2021
Resolution: New detector installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 July 2021
Resolved
The inspector shall examine the bilges in machinery
spaces to see there is no accumulation of oil which
might create a fire hazard. During inspection of the bow
thruster space it was noted that there was approximately
20 inches of oil and water in the bilge. At least 3
inches of oil was on top of the water. On the COI
(3/30/21) inspection similar conditions were found and
documented in the engine room. This indicates the crew and company management are not proactively managing the vessel. Remove oil and clean bilges in bow thruster space.
46 CFR 71.25-45
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 July 2021
Resolution: Approximately 1300 gallons of oil and water were removed from the bilge of the bow thruster space, E/R, and MSD space.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 July 2021
Resolved
The position of the rudder must be shown at the
alternative steering station. Rudder angle indicator at
emergency steering station is not operational. This was
documents as a CG-835 at the COI (3/30/21) and not
corrected and is overdue. No repairs have been made to
date and MI’s were never contacted requesting an
extension. This presents a risk to safe navigation in an
emergency. Prove proper operation rudder angle
indicator.
46 CFR 77.05-1 to 113.40-5
Action required: 30 - Ship detained
Resolved 14 July 2021
Resolution: New rudder angle indicator was installed and tested. Sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 July 2021
Resolved
No flammable or combustible liquids may be stored in any
service space. During inspection of the MSD space a
large trash can was found with approximately 20 gallons
of hydraulic fluid that has been drained from the
elevator space and is being stored. Remove hydraulic oil
from MSD space.
46 CFR 147.45(b)
Action required: 30 - Ship detained
Resolved 14 July 2021
Resolution: Approximately 1300 gallons of oil and water were removed from the bilge of the bow thruster space, E/R, and MSD space.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 July 2021
Resolved
The inspector shall examine the bilges in machinery
spaces to see there is no accumulation of oil which
might create a fire hazard. During inspection of the
engine room a leak for the stbd main engine lube oil
cooler was found with a leak on the flange in way of the gasket. The leak appeared to be on going due to
staining. There was approximately half gallon of lube
oil underneath the cooler. Remove excess oil and repair
leak in lube oil cooler.
46 CFR 71.25-45
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 July 2021
Resolution: Approximately 1300 gallons of oil and water were removed from the bilge of the bow thruster space, E/R, and MSD space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
Oil valves should be readily accessible from outside the
compartment which the valves are located. During the
inspection of the car deck MI's identified vehicles
parked over the emergency fuel shut offs for the bow
thruster space. In this condition the fuel
shut offs would not be able to be closed in an
emergency. Provide corrective action plan to ensure
emergency fuel shut offs remain accessible at all times.
46 CFR 56.50-60(d)(1)
Condition: Invalid
Action required: 30 - Ship detained
Resolved 14 July 2021
Resolution: Company provided documentation of a safety meeting held with crew detailing the standing order to not park cars over the emergency fuel shutoffs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 May 2021
Resolved
Crop and renew escape hatch in sewage void.
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 14 July 2021
Resolution: New hatch installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2021
Resolved
Fire screen door leading from galley to service area will not latch. Adjust door so when the door is released it will close and latch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 16 April 2021
Resolution: Recieved email with video from vessel rep. showing the fire screen doors closing properly.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 30 March 2021
Resolved
During engine room examination the engine room was found to have excessive oil in the bilge. Remove oil and water from bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 14 July 2021
Resolution: E/R pumped out.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 2 December 2020
Resolved
Prove proper operation of rudder angle indicator in emergency steering space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2021
Resolved 14 July 2021
Resolution: New rudder angle indicator installed and tested.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 December 2020
Resolved
Prove proper operation of #1 SSDG high water temp. alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2021
Resolved 30 March 2021
Resolution: Alarm tested sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 December 2020
Resolved
Prove proper operation of STBD M/E high gear oil alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2021
Resolved 24 March 2022
Resolution: New gear oil alarm installed and tested.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 December 2020
Resolved
Prove proper operation of #1 bow thruster gear oil pressure alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2021
Resolved 30 March 2021
Resolution: Alarm tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 December 2020
Resolved
Overhaul and prove proper operation of escape hatch from MSD space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2021
Resolved 30 March 2021
Resolution: hatch was cleaned and operates. However the hatch ring will require replacement at next drydocking in April.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2020
Resolved
Make permanent repair to hole in main car deck port side aft in way of stanchion tube for removable fence.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2020
Resolved 21 September 2020
Resolution: Hole in deck was permanently repaired by a qualified welder
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 September 2020
Resolved
Repair hydraulic leak in operating station for engine room water tight door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2020
Resolved 21 September 2020
Resolution: Leak was repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2020
Resolved
provide lagging for any piping in the engine room over 150 degrees as noted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2020
Resolved 2 December 2020
Resolution: New lagging installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 September 2020
Resolved
Replace high water temperature sensor for #2 bow thruster prime mover
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2020
Resolved 21 September 2020
Resolution: New sensor was installed
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 3 September 2020
Resolved
Replace computer card in alarm panel for the low gear oil alarm on the stbd main engine
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2020
Resolved 3 December 2020
Resolution: New card installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2020
Resolved
secure hydraulic line for steering gear located stbd side of steering void
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2020
Resolved 21 September 2020
Resolution: Hydraulic line has been secured to bracket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 December 2019
Resolved
Prove proper operation of #2 generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 4 December 2019
Resolution: MSD Coram withnessed proper operation of generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 December 2019
Resolved
Make permenant repairs to leak in expansion tank on #1 generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2019
Resolved 4 December 2019
Resolution: Leak repaired and verified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 December 2019
Resolved
Prove proper operation of fire detection in E/R.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2019
Resolved 4 December 2019
Resolution: E/R fire detection tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 December 2019
Resolved
Repair exhaust leak in bow thruster space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 3 September 2020
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 4 December 2019
Resolved
Prove proper operation of emergency generator high water temperature alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 4 December 2019
Resolution: Alarm tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2019
Resolved
make pressure vessels in E/R available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 4 December 2019
Resolution: Pressure vessels internally examined and relife valves tested. Dates updated in MISLE.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019
Resolved
Re-hang light fixture located in the steering gear void. Light fixture was hanging by the electrical supply wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2019
Resolution: Light fixture hung.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2019
Resolved
Provide lagging on all piping on the port and starboard main engine oil coolers that are in excess of 150 degrees.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
Resolution: Issued in error.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 October 2019
Resolved
Weld up holes in work bench adjacent to the engine room water tight door to prevent the actuation handle from being held in the open position by a screw driver or other object. Engine room water tight door was found rigged in such a way as to prevent the door from being closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2019
Resolution: deficiency issued in error.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 10 July 2019
Resolved
Old sewage treatment plant needs to be cleaned out and secured due to leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2019
Resolution: Tank has been cleaned and ready for removal at next drydock.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 10 July 2019
Resolved
Remove old sewage treatment plant at next scheduled dry-dock
Action required: 705 - Other - as specified
Resolved 8 September 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 July 2019
Resolved
Remove and properly dispose of all oily waste water from bilge in engine room and MSD space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2019
Resolved 3 September 2020
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 10 July 2019
Resolved
Engineer assist alarm needs to be installed in the engineer's state room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
Resolution: Alarm installed and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2019
Resolved
Company must provide full size paper copies of approved plans related to the crew cabin additions and modifications. This requirement is noted on each MSC approval letter as a condition of approval in the electronic commerce program.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: Plans recieved at last DD
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 January 2019
Resolved
A transformer is installed under the port side stairs to the uppermost deck in order to step down 240v to 120v. Ground detection must be installed on the newly installed isolated 120v distribution system as per 46 CFR 111.05-21(d). Plans must be updated and approved by MSC prior to system being placing in operation.
Action required: 705 - Other - as specified
Resolved 8 September 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 November 2018
Resolved
Install properly calibrated time delays for the Bolier, EDG and Paint Locker Spaces
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2018
Resolved 6 December 2018
Resolution: Shore side maintenace Organization replaced all time delay bottles with calibrated units.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 November 2018
Resolved
Properly install H2O sensor on #2 generator
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2018
Resolved 8 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2018
Resolved
Fire detection system is alarming on heat detector #59 intermittently and pull station #28 continually. The fire detection system also has a ground fault.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 6 December 2018
Resolution: Fire detection system found sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2018
Resolved
Fire alarm bell in pilot house has been disabled by removing the contact maker and turning the bell around. Prove proper operation of fire alarm bell.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 6 December 2018
Resolution: Fire alarm bell installed correctly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 September 2018
Resolved
Repair or replace port and stbd side shell watertight doors and prove proper operation.
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 6 December 2018
Resolution: Doors repaired in drydock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2018
Resolved
Replace wasted sprinkler piping as needed and conduct test in presence of CG MI.
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 6 December 2018
Resolution: sprinkler system repaired in NY during drydock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 September 2018
Resolved
Repair or replace alarm for engine room water tight door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 6 December 2018
Resolution: Door tested and found sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2018
Resolved
Remove dead end wire on port aft car deck.
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 6 December 2018
Resolution: Dead end wire removed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 8 September 2020
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2018
Resolved
Replace broken light fixture cover located in CO2 room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 26 September 2018
Resolution: Light fixture provided with cover.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 21 June 2018
Resolved
Conduct thorough cleaning of galley, debris under counters and mold around beer kegs in cooler.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2018
Resolved 6 December 2018
Resolution: Galley cleaned iwa new company work instruction.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 June 2018
Resolved
Repair forward stbd heat detector in engine room. Detector is continuously alarming.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 26 September 2018
Resolution: This item cleared but re-issued for similar issue on 26SEP18.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 21 June 2018
Resolved
Replace low lube oil pressure sensor on #1 bow thruster engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 26 September 2018
Resolution: Comleted. Not tested as vessel was underway.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 16 April 2018
Resolved
Prior to the carriage of passengers conduct sea trails.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2018
Resolution: Marine Inspectors attended the vsl today to conduct the sea trials, all SAT and the CG835 was cleared.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 26 March 2018
Resolved
Repair broken sprinkler pipe hanger, starboard side aft, under upper car deck.
Due 26 April 2018
Resolved 12 April 2018
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 26 March 2018
Resolved
Repair smoke detection system. Trouble alarm in the steering space.
Due 26 April 2018
Resolved 12 April 2018
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 26 March 2018
Resolved
Provide velcro securing straps for 3 painter extension tubes for IBAs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 10 April 2018
Resolution: Velcro straps installed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 March 2018
Resolved
Provide placards for starboard side aft lifejacket locker on the sun deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 10 April 2018
Resolution: Placards installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 5 December 2017
Resolved
Re-label emergency fuel shut offs for E-Gen and boiler on Texas deck.
Due 4 January 2018
Resolved 12 April 2018
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 5 December 2017
Resolved
Repair insulation on upper boiler piping.
Due 4 January 2018
Resolved 12 April 2018
Engineering › Steam System (auxiliary) › Valve
Issued 5 December 2017
Resolved
Install elbow on upper boiler releif valve.
Due 4 January 2018
Resolved 12 April 2018
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 5 December 2017
Resolved
Demonstrate operational readness of #2 SSG RVS power trip
Due 4 January 2018
Resolved 12 April 2018
Electrical › Electric Generation Source (service) › Generator
Issued 5 December 2017
Resolved
Propside adjust Hi BMD SST points for #1 and #3 SSG
Due 4 January 2018
Resolved 12 April 2018
Electrical › Electric Generation Source (service) › Generator
Issued 5 December 2017
Resolved
Repair o-ring #3 SSG, at heat exchangers
Due 4 January 2018
Resolved 12 April 2018
Engineering › Thrusters › Motor
Issued 5 December 2017
Resolved
Demonstrate operational readness of bow thruster Low oil alarm.
Due 4 January 2018
Resolved 12 April 2018
Electrical › Electrical Distribution System (service) › Cable
Issued 5 December 2017
Resolved
Repair wasted cable hangers on car deck.
Due 4 January 2018
Resolved 12 April 2018
Navigation › Piloting/Steering › Marine Charts
Issued 5 December 2017
Resolved
Replace chart 12362 and chart 12354 with updated charts.
Due 4 January 2018
Resolved 12 April 2018
Construction/Loadline › Structures › Door
Issued 5 December 2017
Resolved
Install T handle on emergency hatch on PS upper deck stack for engine room.
Due 4 January 2018
Resolved 12 April 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 December 2017
Resolved
Repair bilge alarm in void #5.
Condition: Improper/Lack of Maintenance
Due 4 January 2018
Resolved 12 April 2018
Engineering › Bilge Water Management System › Piping
Issued 5 December 2017
Resolved
Re-attach fore peak bilge bracket.
Due 4 January 2018
Resolved 12 April 2018
Engineering › Bilge Water Management System › Strainer
Issued 5 December 2017
Resolved
Replace bilge screen in Void 4?
Due 4 January 2018
Resolved 12 April 2018
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 5 December 2017
Resolved
Repair broken urinals
Due 4 January 2018
Resolved 26 September 2018
Resolution: Uninals replaced.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 March 2017
Resolved
Repair electrical receptacle on focsle. Box is held togther with zip ties.
Due 8 April 2017
Resolved 27 April 2017
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 8 March 2017
Resolved
Repair damaged thermostat in deli.
Due 8 April 2017
Resolved 27 April 2017
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 March 2017
Resolved
Replace battery and repair detector located in the steering space on smoke detection system.
Due 8 April 2017
Resolved 27 April 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 8 December 2016
Resolved
Repair loose hanging electrical cables on the starboard car deck, midship.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Cable repaired.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 December 2016
Resolved
Repair burnt electrical heat tape on the port car deck midship.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2016
Resolution: Heating tape repaired.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 8 December 2016
Resolved
Conduct complete test of all alarm, safeties, and shutdowns in accordance with CG approved automation test procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2016
Resolution: Test completed and witness by CG Marine Insepctors.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 December 2016
Resolved
Replace wasted section of intercooler feed water piping on the port MDE.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Piping repaired.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 December 2016
Resolved
Secure loose electrical cable on the port side of the engine room in way of the air compressor.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Cable secured.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 December 2016
Resolved
Secure wiring into junction box and remove oil from box and wiring located on the deck next to the port main engine.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Wiring secured.
Construction/Loadline › Structures › Superstructure
Issued 8 December 2016
Resolved
Service hydraulic ram for the service elevator and clean all oil from the underside of the elevator and elevator shaft.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Ram serviced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 December 2016
Resolved
Make drain from the elevator shaft penetrating the MSD room aft water tight bulkhead water tight and remove and properly dispose of waist oil drained from elevator shaft.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Drain secured.
Engineering › Bilge Water Management System › Strainer
Issued 8 December 2016
Resolved
Clean all oil and oil soaked sorbent pads from engine room and MSD room bilges.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Bilges cleaned.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 8 December 2016
Resolved
Replace temperature gauge on starboard side generator #1.
Due 8 January 2017
Resolved 14 December 2016
Resolution: Gauge repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 October 2016
Resolved
Repair exhaust leaks on both the port and starboard exhaust manifolds
Due 3 November 2016
Resolved 8 November 2016
Engineering › Freshwater System (cylinder head cooling) › Suction Strainer
Issued 5 October 2016
Resolved
Replace sea strainer on #1 generator.
Due 3 November 2016
Resolved 8 November 2016
Construction/Loadline › Structures › Door
Issued 5 October 2016
Resolved
Replace waisted locker room doors located aft on the main car deck.
Due 3 November 2016
Resolved 15 November 2016
Construction/Loadline › Structures › Manhole
Issued 5 October 2016
Resolved
Provide a T-handle for the emergency escape hatch for the port stack.
Due 3 November 2016
Resolved 8 November 2016
Construction/Loadline › Structures › Door
Issued 5 October 2016
Resolved
Repair self closing door located on the stbd side vehicle ramp.
Due 3 November 2016
Resolved 8 November 2016
Fire Fighting › Fire Hoses › Condition
Issued 5 October 2016
Resolved
Service all fire stations valves and nozzel.
Due 3 November 2016
Resolved 8 November 2016
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 5 October 2016
Resolved
Eco-depth sounder was not functional. Replace/repair to original.
Due 3 November 2016
Resolved 15 November 2016
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 25 March 2016
Resolved
Repair or replace sensors located in the port aft engine room and sstbd forward engine room.
Due 24 April 2016
Resolved 6 May 2016
Construction/Loadline › Structures › Door
Issued 25 March 2016
Resolved
Repair door latch at upper car deck stbd side aft.
Due 24 April 2016
Resolved 6 May 2016