Professional
The full record for this vessel
Behind this panel: 8 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 8
7 September 2022
PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7553421
11 January 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7378361
19 August 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6782055
3 January 2019
PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6604695
10 October 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6284368
25 October 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6029449
28 July 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5955789
26 April 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5862608
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2022
No resolution recorded
The following basic principles underlie the regulations in this chapter are embodied in the regulations as appropriate, having regard to the type of ships and the potential fire hazards involved: containment and extinction of any fire in the space of origin. PSCO observed accumulation of oil in the bilge in way of the fly wheel and thermal oil underneath the settling tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 September 2022
No resolution recorded
Where "A" class divisions are penetrated for the passage of electrical cables, pipes, trunks, ducts, ect., or for girders, beams, or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired. PSCO observed a cable penetration in a A-0 bulkhead without proper insulation.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2022
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. PSCO observed a plastic bag covering 01 smoke detectors near the main engine.
Action required: 10 - Deficiency Rectified
Resolved 7 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2022
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed melted extension cord connection to a space heater in bosn stores and PSCO observed bosn store bilge alarm wire electrical taped to power supply. 74SOLAS(04)con II-I/45.13
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 14 January 2022
Resolution: Received class report attesting to satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 January 2022
Resolved
Cargo ships with a horizontal distance from end of stern to nearest survival craft is more than 100m shall carry additional life raft. Such liefraft maybe securely fastened so as to permit manual release. PSCO observed forward liferaft secured by painted shackle. Not allowing manual release. 74SOLAS(20)con III/31.1.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 14 January 2022
Resolution: Received class report attesting to satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2022
Resolved
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be madein the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed no procedures in place for using ballast water tank as a sewage holding tank. 74SOLAS(20)con I/II(b)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 14 January 2022
Resolution: Received class report attesting to satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 January 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed engine room bilge alarm and corresponding indicating light inoperable. 74SOLAS(20)con I/II
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2022
Resolved 11 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 11 January 2022
Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stowed. PSCO observed 02 immersion suits with holes below the zipper in bosn stores. 74SOLAS(20)con III/32.3.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2022
Resolved 11 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 January 2019
Resolved
The fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed the majority of the fire extinguisher brackets in the engine room were wire-tied shot or broken, as well as, 02 fire extinguisher hoses were kinked and exhibiting dry-rot. 74SOLAS(2014)II/2/14.1.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 August 2019
Resolution: Recieved documentation from class attesting to new brackets being installed as well as new hoses bought and put into service.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 October 2016
Resolved
All ships of 3,000 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.5, have: where considered appropriate by the administration, a second 9 GHz radar, or other means, to determine and display the range and bearing of other surface craft, obstructions, buoys, shorlines and navigational marks to assist in navigation and in collision avoidance,which are function
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 26 October 2016
Resolution: Tech report submitted
Fire Fighting › Fire Pumps › Pressure
Issued 27 April 2016
Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. Vessel emergency fire pump cannot provide adequate water pressure to the firemain system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2016
Resolution: Received BV Class Report dated 27APR2016. Class report saved in MISLE Documentation.