MAURY USCG vessel records Sign in
← All vessels

KANO REEFER

KANO REEFER is a 1999 freight ship. The Coast Guard has recorded 15 inspections since 2010, most recently in September 2022, along with 13 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 2010 to 2022. Most recent: inspection, 7 September 2022.

Built
1999
Last inspected
7 September 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9194957 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
497766
Flag
PANAMA
—
Maury page id
psix-497766

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 7 calendar years (2010–2022)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it4600 - Dead Weight, Ton
4734 - Convention (Subpart B), Net Ton
8507 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

7 September 2022 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7553421
11 January 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7378361
19 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6782055
3 January 2019 PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6604695
10 October 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6284368
25 October 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6029449
28 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5955789
26 April 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5862608
17 December 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5783829
27 October 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5752029
23 October 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5749317
28 December 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4214835
27 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4212905
18 January 2011 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3928138
22 December 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3914698

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2022 No resolution recorded
The following basic principles underlie the regulations in this chapter are embodied in the regulations as appropriate, having regard to the type of ships and the potential fire hazards involved: containment and extinction of any fire in the space of origin. PSCO observed accumulation of oil in the bilge in way of the fly wheel and thermal oil underneath the settling tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 September 2022 No resolution recorded
Where "A" class divisions are penetrated for the passage of electrical cables, pipes, trunks, ducts, ect., or for girders, beams, or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired. PSCO observed a cable penetration in a A-0 bulkhead without proper insulation.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2022 Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. PSCO observed a plastic bag covering 01 smoke detectors near the main engine.
Action required: 10 - Deficiency Rectified
Resolved 7 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed melted extension cord connection to a space heater in bosn stores and PSCO observed bosn store bilge alarm wire electrical taped to power supply. 74SOLAS(04)con II-I/45.13
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 14 January 2022
Resolution: Received class report attesting to satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 January 2022 Resolved
Cargo ships with a horizontal distance from end of stern to nearest survival craft is more than 100m shall carry additional life raft. Such liefraft maybe securely fastened so as to permit manual release. PSCO observed forward liferaft secured by painted shackle. Not allowing manual release. 74SOLAS(20)con III/31.1.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 14 January 2022
Resolution: Received class report attesting to satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2022 Resolved
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be madein the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed no procedures in place for using ballast water tank as a sewage holding tank. 74SOLAS(20)con I/II(b)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 14 January 2022
Resolution: Received class report attesting to satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed engine room bilge alarm and corresponding indicating light inoperable. 74SOLAS(20)con I/II
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2022
Resolved 11 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 11 January 2022 Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stowed. PSCO observed 02 immersion suits with holes below the zipper in bosn stores. 74SOLAS(20)con III/32.3.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2022
Resolved 11 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 January 2019 Resolved
The fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed the majority of the fire extinguisher brackets in the engine room were wire-tied shot or broken, as well as, 02 fire extinguisher hoses were kinked and exhibiting dry-rot. 74SOLAS(2014)II/2/14.1.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 August 2019
Resolution: Recieved documentation from class attesting to new brackets being installed as well as new hoses bought and put into service.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 October 2016 Resolved
All ships of 3,000 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.5, have: where considered appropriate by the administration, a second 9 GHz radar, or other means, to determine and display the range and bearing of other surface craft, obstructions, buoys, shorlines and navigational marks to assist in navigation and in collision avoidance,which are function
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 26 October 2016
Resolution: Tech report submitted
Fire Fighting › Fire Pumps › Pressure
Issued 27 April 2016 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. Vessel emergency fire pump cannot provide adequate water pressure to the firemain system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2016
Resolution: Received BV Class Report dated 27APR2016. Class report saved in MISLE Documentation.
Communications › Radio Communications › EPIRB
Issued 28 December 2011 Resolved
1671 (Satellite EPIRB 406 MHz/1.6GGHz) - Every ship shall be provided with a satellite EPIRB which is capable of floating free if the ship sinks. The hydrostatic release unit currently installed on the EPIRB is designed for life raft use. Cite: 74 SOLAS (09 CONS) IV/7.1.6.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2011
Resolution: Sector Delaware Bay PSC branch received copy of receipt from local supplier for correct EPIRB hydrostatic release mechanism.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 22 December 2010 Resolved
1420 -Cleanliness of Engine Room - PSCO found unclean conditions in the engine room. The F/O purifier located next to the O.W.S has oil soaked lagging, the fuel filters for the #1 & #2 generator sets is covered in oil, and the lagging for the low pressure fuel supply line going to the fuel injection pump is soaked with oil. SOLAS74 (2004 Cons.) Ch.II-1/Reg. 26.7
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 18 January 2011
Resolution: PSCO verified that required lagging was replaced and fuel filters were cleaned. Deficiency rectified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.