MAURY USCG vessel records Sign in
← All vessels

TONY G

TONY G is a 1978 offshore supply vessel. The Coast Guard has recorded 47 inspections since 1981, most recently in April 2016, along with 49 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1981 to 2016. Most recent: inspection, 15 April 2016.

Built
1978
Last inspected
15 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYB6693
Flag
TANZANIA
367166850, 367466530 (licence lapsed)
Maury page id
psix-49783

Inspections, by type

…with no type recorded7
…past their stated due date1
Years with a record 33 calendar years (1981–2016)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF5724MMSI 367466530 · expired · compulsorily equipped · granted 16 September 2010, cancelled 21 November 2020
WYB6693MMSI 367166850 · expired · voluntarily equipped · granted 14 June 2000, cancelled 14 August 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

15 April 2016 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5855027
24 February 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5820654
23 February 2016 Uninspected Other
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5821861
7 February 2016 Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5818784
29 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5755632
27 January 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3933638
23 March 2010 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3700856
21 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3463327
19 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3434285
10 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3189923
23 March 2007 Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2897684
7 April 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2619231
4 April 2005 Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2317362
5 May 2004 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2060141
16 April 2004 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2045205
15 April 2004 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2045176
30 April 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1783549
1 August 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1656040
21 March 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1491196
29 May 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1405213
30 May 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381835
9 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388756
11 March 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408078
12 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467502
4 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437054
1 March 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1157832
1 March 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353761
24 March 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358345
21 May 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414162
23 March 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1318907
2 December 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251937
29 November 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938871
16 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219501
1 April 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928418
22 March 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211390
14 March 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338059
27 February 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042122
30 January 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035864
6 October 1988 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890457
16 March 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338572
9 April 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003998
24 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306225
16 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983172
10 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280465
27 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275568
2 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969087
12 June 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971634

Deficiency record · 49

Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 January 2011 No resolution recorded
Install proper overboard piping for washer gray water at next hull exam (2013)
Action required: 705 - Other - as specified
Due 31 December 2013 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 27 January 2011 Resolved
Install proper engine air flap on stbd MDE.
Due 27 February 2011
Resolved 24 February 2011
Fire Fighting › Means of Escape › Number
Issued 21 April 2009 Resolved
Vessel has 18 person berthing area over 12' in length and requires a 2nd means of escape IAW old T regs.
Action required: 705 - Other - as specified
Due 21 April 2010
Resolved 27 January 2011
Stability › Watertight Integrity › General
Issued 19 March 2009 Resolved
Install hard gasket on Engine Room Water Tight door.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Resolution: Installed hard gasket in Engine room wtd to ensure proper fit and water tight integrity.
Construction/Loadline › Hull › Bracket
Issued 19 March 2009 Resolved
Sister weld good plate to bottom angle in port side engineroom that will require to be cropped and renewed at next dry dock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Resolution: Completed sister weld of good angle iron to wasted hull angle in port side engine room.
Navigation › Piloting/Steering › Marine Charts
Issued 19 March 2009 Resolved
Provide large scale corrected nautical chart for area operating.
Condition: Unknown
Due 19 April 2009
Resolved 27 March 2009
Resolution: Purchased upadated nautical chart of area.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 19 March 2009 Resolved
Provide a cap for Fuel oil hose from Fuel oil pump in Engine Room.
Condition: Unknown
Due 19 April 2009
Resolved 27 March 2009
Resolution: Cap for hose was purchased and installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 April 2008 Resolved
Master's FCC radio operators license was expired.
Action required: 705 - Other - as specified
Resolved 23 April 2008
Resolution: Received verification of renewed license.
Engineering › Bilge Water Management System › Not Operational
Issued 23 March 2007 Resolved
The bilge alarm did not function.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 March 2007 Resolved
The magnetic compass light did not work.
Action required: 705 - Other - as specified
Resolved 9 April 2007
Fire Fighting › Nozzles › Type
Issued 23 March 2007 Resolved
The AFFF nozzle was missing the required adapter to tie into the existing fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Engineering › Lubricating Oil Service System › Gauge
Issued 23 March 2007 Resolved
The jacket water temperature and lube oil pressure gauges were not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2007
Engineering › Fuel Oil Service System › Hose
Issued 7 April 2006 Resolved
Renew chaffed stbd engine fuel hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 April 2006 Resolved
Blank off open breaker holes in engine room panel boards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2006
Resolution: Corrected.
Lifesaving › Lifefloat › Paddle
Issued 7 April 2006 Resolved
Stencil paddles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2006
Resolution: Corrected.
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2005 Resolved
Repair and crop wasted area in way of starboard engine room hull.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2005
Resolved 7 April 2005
Resolution: Completed.
Construction/Loadline › Structures › End Bulkhead
Issued 4 April 2005 Resolved
Make repairs to weqage tank
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2005
Resolved 7 April 2005
Resolution: Completed
Fire Fighting › Fire Main › Condition
Issued 4 April 2005 Resolved
Make repairs to fire punp leaks, install gauge and demonstrate proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2005
Resolved 7 April 2005
Resolution: Completed
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 April 2005 Resolved
Secure fire monitor f/o supply and return lines.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2005
Resolved 7 April 2005
Resolution: Completed
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 April 2005 Resolved
Repair all f/o remote vlaves
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2005
Resolved 7 April 2005
Resolution: Completed
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2005 Resolved
Seal forward e/r bulkhead port side.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2005
Resolved 7 April 2005
Resolution: Completed
Engineering › Fuel Oil Service System
Issued 5 May 2004 Resolved
Port & starboard emergency F/O shut-off remote control for valves seized and not turning LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 13 May 2004
Resolution: Replaced remote control valves with new equipment
Documentation › Manuals/Policy Documentation
Issued 15 April 2004 Resolved
Provide vessel transfer procedures. Crew could not locate item during inspection LEGACY COMPONENT DESC: Transfer Procedures
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 16 April 2004
Resolution: Transfer procedures located on board vessel
Electrical › Electrical Distribution System (service)
Issued 15 April 2004 Resolved
Cable located in overhead of void space fwd of engine room secured with plastic zip ties. CG835 issued to replace with metal banding LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 26 April 2004
Resolution: Wire secured in overhead with metal banding
Electrical › Electric Supply System (service)
Issued 15 April 2004 Resolved
Battery storage holder and deck sub-structure rotted out, possibly from battery acid contamination. Issued CG835 to replace entire structure. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 26 April 2004
Resolution: Fabricated new deck support, purchased new battery box
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 April 2004 Resolved
Ensure that COI is endorsed for the carriage of packaged hazardous waste, ensure that necessary deck and firefighting equipment is on-board vessel to accomodate endorsment. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Resolved 7 April 2005
Resolution: All required fire-fighting wquipment is on board.
Construction/Loadline › Structures
Issued 15 April 2004 Resolved
Hinge mounts supporting engine room escape hatch wasted. Issued CG835 to replace hinge mounts LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 28 April 2004
Resolution: Fabricated new hinge mounts for scuttle hatch
Construction/Loadline › Penetrations
Issued 15 April 2004 Resolved
Stuffing box located in deck vestibule to engine room, several old wires and cut-off piping petruding though box terminating in vestibule. Issued CG835 to remove same and properly plug holes.
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 28 April 2004
Resolution: Items removed, stuffing box sealed.
Construction/Loadline › Structures
Issued 15 April 2004 Resolved
Clutch oil piping in void space fwd of engine room not secured to bulkhead. Issued CG835 to properly secure piping
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 28 April 2004
Resolution: Fabricated new brackets to secure piping
Lifesaving › Buoyant Apparatus
Issued 30 April 2003 Resolved
BA Paddles were wasted and worn...Directed Port Engineer to obtain 4 new paddles for BA's. LEGACY COMPONENT DESC: Paddles
Condition: Improper/Lack of Maintenance
Due 29 May 2003
Resolved 15 April 2004
Resolution: Paddles replaced.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 April 2003 Resolved
Vessel rep directe to label all switchboard components (toggles, push-buttons, ect...)
Condition: Unknown
Due 29 May 2003
Resolved 30 April 2003
Resolution: Crew properly labled all switchboard components.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 April 2003 Resolved
Vessel was missing non-conductive mat to be located in front of electrical switchboard. LEGACY COMPONENT DESC: Non-conducting mat
Condition: Unknown
Due 29 May 2003
Resolved 30 April 2003
Resolution: Vessel Represenative provided non-conducting mat in the presence of Marine Inspector.
Electrical › Electrical Distribution System (service)
Issued 30 April 2003 Resolved
Remove current busted junction box, which engine room bildge pump ties into, and replace with new juntion box. LEGACY COMPONENT DESC: Junction Box
Condition: Damaged By Earlier Event
Due 29 May 2003
Resolved 15 April 2004
Resolution: Replaced.
Electrical › Electrical Distribution System (service)
Issued 30 April 2003 Resolved
Place a blank within slot 25 on main switchboard. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Due 29 May 2003
Resolved 15 April 2004
Resolution: Blanked.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 30 April 2003 Resolved
Vessel representative was directed to replace lagging on both port and strb exhust pipes. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Due 29 May 2003
Resolved 30 April 2003
Resolution: Vessel representative had crew replace lagging during inspection.
Pollution Prevention/Response › Prevention Equipment
Issued 30 April 2003 Resolved
Crew was directed to tighten loose chain on MSD valve and also directed to install ball valve for sewage tank. LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Condition: Improper Installation
Due 29 May 2003
Resolved 15 April 2004
Resolution: Valve secured.
Operations/Management › Drills/Instruction
Issued 30 April 2003 Resolved
Vessel representative was directed to provide emergency broadcast plackard, passenger orientation list, station bill, and emergency instruction list per 46 CFR 185 LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Due 29 May 2003
Resolved 15 April 2004
Resolution: Placards posted.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 April 2003 Resolved
Dryer had a pillow case in place as a lint trap. Vessel representative was directed to replace it with a proper catch design lint trap. LEGACY COMPONENT DESC: Laundry
Condition: Improper Installation
Due 29 May 2003
Resolved 15 April 2004
Resolution: Installed correct trap.
Lifesaving › Lifejacket/PFD (Type IV)
Issued 30 April 2003 Resolved
2 pfd's were misssing lights LEGACY COMPONENT DESC: Lights
Condition: Unknown
Due 29 May 2003
Resolved 15 April 2004
Resolution: Replaced.
Engineering › Fuel Oil Service System
Issued 30 April 2003 Resolved
Directed vessel representative to replace fuel flame screens on both port and starboard fuel vents. LEGACY COMPONENT DESC: Vent Pipe
Condition: Damaged By Earlier Event
Due 29 May 2003
Resolved 15 April 2004
Resolution: Replaced.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 March 2002 Resolved
CURRENT TIDAL CURRENTS NOT NOT PROVIDED.
Condition: Unknown
Due 21 March 2002
Resolved 21 March 2002
Construction/Loadline › Structures › Door
Issued 21 March 2002 Resolved
ALL WATERTIGHT DOORS OUT OF ADJUSTMENT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2002
Resolved 21 March 2002
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 March 2002 Resolved
ALL REQUIRED LOGBOOK ENTRIES NOT BEING LOGGED.
Due 22 March 2002
Resolved 22 March 2002
Lifesaving › Lifebuoys
Issued 21 March 2002 Resolved
CONDEMENED TWO RING BOUYS.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2002
Resolved 21 March 2002
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 March 2002 Resolved
BLANKS NOT INSTALLED IN OPENINGS IN DISTRBUTION PANEL IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2002
Resolved 21 March 2002
Unknown
Issued 29 May 2001 Resolved
Vessel was missing an updated sticker for their Certificate of Documentation. MSIS show that their documentation is up to date.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Unknown
Issued 29 May 2001 Resolved
Could not demonstrate proper use of the sideband radio due to radio not being programmed.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Engineering
Issued 1 April 1991 Resolved
INSTALL PILOT HOUSE STARTS AND STOPS FOR MAIN ENGINES IAW 46 CFR 175.10-29.AN ALTERNATIVE COMMUNICATIONS SYSTEM INSTALLED UNDER 46 CFR 184.35-1 _x001C_ MAYBE CONSIDERED AND APPROVED BY THE OCMI.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Construction/Loadline
Issued 24 April 1986 Resolved
EFFECT PERMANENT REPAIRS TO FRACTURED LONGITUNDINAL FRAME PORT SIDE IN FORE PEAK COMPT. APPROX 8FT' AFT OF BOW 5FT BELOW MAIN DECK TO BE COMPLETED PRIOR TO 24MAY86.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.