Records from 1985 to 2011. Most recent: inspection, 25 July 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
25 July 2011
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4090479
11 November 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1703887
9 July 2000
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1051784
5 June 2000
COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365861
22 July 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457679
18 June 1999
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365271
17 November 1998
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 806011
16 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 806845
17 September 1998
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1372375
21 May 1998
COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 795957
17 July 1997
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1118178
17 September 1996
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 139342
30 June 1996
Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1085054
20 December 1995
Administrative
Administrative · Commandant (CG-CVC) · Activity 870889
10 September 1995
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1193319
21 June 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 95674
20 June 1994
Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 859336
25 April 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 113587
15 January 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 25599
8 December 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1159632
30 November 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1159149
12 September 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 833278
26 July 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 844274
9 July 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 221794
7 June 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 176359
19 December 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 180426
11 November 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 89938
5 November 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946464
14 June 1992
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953892
10 February 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 94304
28 December 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 61365
24 September 1991
Administrative
Administrative · Commandant (CG-CVC) · Activity 1002872
3 July 1991
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936781
19 February 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914298
6 November 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909810
22 June 1990
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919589
24 January 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229168
26 September 1989
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 898633
27 December 1988
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197747
6 May 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1344658
20 March 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 994630
12 December 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004710
27 December 1986
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1002103
1 November 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301123
Fire Fighting
Issued 17 July 1997
Resolved
REPLACE THE MISSING PLACARD ON THE DRY CHEMICAL SYSTEMS LOCATED ON THE MAINDECK.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 17 July 1997
Resolved
PROVIDE SUFFICIENT PROVISIONS FOR THE PORT LIFEBOAT PRIOR TO THE VESSELS DEPARTURE.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 8 December 1993
Resolved
RENEW OR MAKE PERMANENT REPAIRS TO THE PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH THE MANUFACTURER'S REPAIR PLAN TO THE SATISFACTION TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Fire Fighting
Issued 26 July 1993
Resolved
UNPLUG ALL CLOGGED NOZZLES ON WATER CURTAIN SYSTEM,(APPOX.30) REMOVE PAINT FROM DIFFUSERS AND REPLACE ALL BENT DIFFUSERS. _x001C_
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Lifesaving
Issued 26 July 1993
Resolved
PROVIDE TO [name withheld], MANUFACTURER'S REPAIR PLANS FOR BOTHPORT AND STB LIFEBOATS TO INCLUDE, BUT NOT LIMITED TO, REPAIRS OF SHELL- INNER DECK(SEPARTION), ALL HAND RAILS, CONDITION AND REPLACEMENT OF FLOTATION AND DRILLED HOLES IN KEELS(4 EA. PER BOAT).
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Fire Fighting
Issued 26 July 1993
Resolved
MAKE TEMPORARY REPAIRS TO WATER CURTAIN PIPING, REPAIR SOFT PATCH, HOLE IN PIPING ON STB SIDE MAINFOLD, HOLE IN PIPING ON AFT COMPRESSOR ROOM BULKHEADAND HOLE IN PIPING ON PORT SIDE MAINFOLD. UPON COMPLETION TEST TO WORKING PRESSURE IN PRESENCE OF A MARINE INSPECTOR
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993
Fire Fighting
Issued 26 July 1993
Resolved
MAKE PERMANENT REPAIRS TO WATER CURTAIN SYSTEM PIPING, THAT HAVE BEEN TEMPORARY REPAIRED BY ITEM 01. AFTER REPAIRS HYDRO PIPING TO 1.5 TIMES MAWPIN PRESENCE OF A MARINE INSPECTION_x001C_
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Unknown
Issued 22 June 1990
Resolved
REPLACE THE FOLLOWING NON-METALLIC EXPANSION JOINTS: S.W. SERVICE SUCTION & DISCHARGE, MAIN L.O. COOLFR OUT AUX COND X-OVER, BOTH L.O. COOLFR INLETS,L.O. COOLFR OUT AND NO.1 AUX CIRC PUMP SUCTION.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 22 June 1990
Resolved
PROVIDE COAST GUARD APPROVED PLANS OR APPROVAL LETTER FOR WHEEL HOUSE SLID-ING DOOR FASTNERS. SHOULD SAME NOT BE GIVEN APPROVAL, FASTNERS SHALL BE REMOVED IMMEDIATELY UPON NOTIFICATION.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 22 June 1990
Resolved
REPLACE WITH CURRENT/WITH-IN SERVICE DUF DATE FORWARD INFLATEABLE LIFERAFT.REPLACEMENT SHALL BE CAPABLE OF CARRYING AT LEAST 10 PERSONS.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 24 January 1990
Resolved
SERVICE ALL PORTABLE, SEMI-PORTABLE AND FIXED CONTROLS AND FIRE EXTINGUISHING SYSTEMS IN ACCORDANCE WITH 46 CFR 31.10-18 AND 31.10-18A.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 24 January 1990
Resolved
REPAIR OR REPLACE THE RELIEF VALVES FOR THE SSDG STARTING AIR BOTTLES TO RELIEVE AT OR BELOW THE MAWP OF THE BOTTLES.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 24 January 1990
Resolved
HYDRO TEST ALL FIRE HOSES IN ACCORDANCE WITH 46 CFR 31.10-12.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 24 January 1990
Resolved
REPAIR THE OILY WATER SEPARATOR SO THAT IT PROPERLY SAMPLES THE EFFLUENT FROM THE SEPARATOR. UNTIL THIS IS REPAIRED, ALL THE EFFLUENT MUST BE PUMPED INTO THE OILY WASTE TANK AND THE OVERBOARD VALVE MUST BE SECURED.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 27 December 1988
Resolved
REPAIR/REPLACE DEFECTIVE 15 PPM OIL CONTENT DETECTOR/ALARM UNIT. OPERATIONOF OWS OVERBOARD DISCHARGE IN AUTOMATIC MODE PROHIBITED UNTIL DETECTOR/ ALARM UNIT IS OPERATIONAL.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Lifesaving
Issued 27 December 1988
Resolved
DEMONSTRATE THAT KHI ALUMINUM WELD PROCEDURE SK-64-1 OF 11 FEB 1976 MEETS ALL APPLICABLE ASME CODE/CFR REQUIREMENTS, OR REQUALIFY IIL 5086-0 ALUMINUMWELD PROCEDURE FOR ASME CODE/CFR. REPAIR TO CARGO TANK #3 CONSIDERED TEMPORARY PENDING COMPLETION OF APPROVED WELD PROCEDURE QUALIFICATION.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Electrical
Issued 12 December 1987
Resolved
REPAIR OR REPLACE THE MISSING ACTIVATION LEVER CONNECTING ROD FOR THE STARBOARD LIFEBOAT EXTERIOR DISCONNECT BREAKER.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Lifesaving
Issued 12 December 1987
Resolved
REPAIR OR REPLACE THE BROKEN PORT LIFEBOAT EMBARKATION LADDER.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Deck/Cargo
Issued 12 December 1987
Resolved
PERMANENTLY REPAIR THE PATCHED INERT GAS GENERATOR AFTERCOOLER WATER SUPPLYLINE.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987
Resolved
PERMANENTLY REPAIR THE PATCHED HULL PROTECTION LNG SPILL WASHDOWN SUPPLY LINE AT THE STARBOARD SIDE CARGO MANIFOLD.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Lifesaving
Issued 12 December 1987
Resolved
PROVIDE A LIFERAFT DEPLOYMENT INSTRUCTION PLACARD FOR THE STBD RAFT.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Electrical
Issued 12 December 1987
Resolved
PERMANENTLY REPAIR THE BROKEN CABLE TRAY HANGER AND PIPE HANGER LOCATED IN THE VICINITY OF FRAME 73, PORT UNDERDECK TUNNEL.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987
Resolved
CONDUCT ANNUAL SERVICING OF THE SKID MOUNTED ANSUL DRY CHEMICAL EXTINGUISHERS. PROVIDE A COPY OF THE SERVICE CERTIFICATE TO THE [name withheld], HI.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987
Resolved
COMPLETE THE ANNUAL SERVICING OF THE FIXED CO2 SYSTEM, INCLUDING HYDRO- STATIC TESTING OF ANY CYLINDER WHICH HAS NOT BEEN TESTED WITHIN PRECEDING 12 YEARS. PROVIDE [name withheld], WITH A COPY OF THE SERVICE CERTIFICATE.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987
Resolved
COMPLETE AN ANNUAL SERVICING OF SEMI-PORTABLE AND PORTABLE DRY CHEMICAL ANDCO2 EXTINGUISHERS, INCLUDING HYDROSTATIC TESTING OF ALL PORTABLE CO2 CYLINDERS WHICH HAVE NOT RECEIVED SUCH TESTING WITHIN THE PREVIOUS 5 YEARS.PROVIDE [name withheld] WITH A COPY OF THE SERVICE CERTIFICATE.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Deck/Cargo
Issued 12 December 1987
Resolved
REPAIR OR REPLACE THE INOPERATIVE ROTATOR UNIT FOR THE STARBOARD SIDE "GAS IN CCR" ALARM BEACON.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Electrical
Issued 12 December 1987
Resolved
PERMANENTLY REPAIR THE PATCHED SSTG SALT WATER COOLING LINES AT ENGINE ROOM12 FOOT LEVEL, FRAME 44, PORT OVERHEAD; ENGINE ROOM 17 FOOT LEVEL, FRAME 38PORT OVERHEAD; AND ENGINE ROOM 12 FOOT LEVEL, FRAME 50, PORT SIDE NEAR #1 AUXILIARY CONDENSER.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Deck/Cargo
Issued 27 December 1986
Resolved
REMOVE ANY PAINT, SILICON, UNAUTHORIZED GASKET OR WRAP FROM BETWEEN AND AROUND THE CONTACT POINT BETWEEN THE COVER AND EXPLOSION PROOF ELECTRICAL JUNCTION BOX FOR ALL SUCH JUNCTION BOXES IN THE FOLLOWING LOCATIONS: CARGOTANK DOME TOPS, CARGO TANK CATWALK, PORT & STBD CARGO MANIFOLDS (CONTINUED)
Condition: Unknown
Due 27 December 1986
Resolved 27 December 1986
Deck/Cargo
Issued 27 December 1986
Resolved
(CONTINUED FROM ABOVE) AND IN AND AROUND THE CARGO COMPRESSOR ROOM. TO BECOMPLETED PRIOR TO LOADING CARGO.
Condition: Unknown
Due 27 December 1986
Resolved 27 December 1986
Unknown
Issued 1 November 1985
Resolved
HAVE ALL FIRE EXTINGUISHING SYSTEMS AND EXTINGUISHERS SERVICED, AND FURNISHA COPY OF THE SERVICING CERTIFICATES TO THIS OFFICE.
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985