MAURY USCG vessel records Sign in
← All vessels

LNG LIBRA

LNG LIBRA is a 1979 tank ship. The Coast Guard has recorded 44 inspections since 1985, most recently in July 2011, along with 30 deficiencies.

Records from 1985 to 2011. Most recent: inspection, 25 July 2011.

Built
1979
Last inspected
25 July 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7413232 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
366264000 (licence lapsed)
Maury page id
psix-49790

Inspections, by type

…with no type recorded15
Years with a record 18 calendar years (1985–2011)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28525 - Convention (Subpart B), Net Ton
95084 - Convention (Subpart B), Gross Ton
72650 - Dead Weight, Ton
101200 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDZGMMSI 366264000 · terminated · compulsorily equipped · granted 30 January 1998, cancelled 1 December 2000
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 44

25 July 2011 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4090479
11 November 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1703887
9 July 2000 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1051784
5 June 2000 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365861
22 July 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457679
18 June 1999 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365271
17 November 1998 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 806011
16 November 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 806845
17 September 1998 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1372375
21 May 1998 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 795957
17 July 1997 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1118178
17 September 1996 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 139342
30 June 1996 Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1085054
20 December 1995 Administrative
Administrative · Commandant (CG-CVC) · Activity 870889
10 September 1995 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1193319
21 June 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 95674
20 June 1994 Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 859336
25 April 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 113587
15 January 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 25599
8 December 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1159632
30 November 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1159149
12 September 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 833278
26 July 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 844274
9 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 221794
7 June 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 176359
19 December 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 180426
11 November 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 89938
5 November 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946464
14 June 1992 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953892
10 February 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 94304
28 December 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 61365
24 September 1991 Administrative
Administrative · Commandant (CG-CVC) · Activity 1002872
3 July 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936781
19 February 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914298
6 November 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909810
22 June 1990 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919589
24 January 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229168
26 September 1989 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 898633
27 December 1988 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197747
6 May 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1344658
20 March 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 994630
12 December 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004710
27 December 1986 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1002103
1 November 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301123

Deficiency record · 30

Fire Fighting
Issued 17 July 1997 Resolved
REPLACE THE MISSING PLACARD ON THE DRY CHEMICAL SYSTEMS LOCATED ON THE MAINDECK.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 17 July 1997 Resolved
PROVIDE SUFFICIENT PROVISIONS FOR THE PORT LIFEBOAT PRIOR TO THE VESSELS DEPARTURE.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 8 December 1993 Resolved
RENEW OR MAKE PERMANENT REPAIRS TO THE PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH THE MANUFACTURER'S REPAIR PLAN TO THE SATISFACTION TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Fire Fighting
Issued 26 July 1993 Resolved
UNPLUG ALL CLOGGED NOZZLES ON WATER CURTAIN SYSTEM,(APPOX.30) REMOVE PAINT FROM DIFFUSERS AND REPLACE ALL BENT DIFFUSERS. _x001C_
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Lifesaving
Issued 26 July 1993 Resolved
PROVIDE TO [name withheld], MANUFACTURER'S REPAIR PLANS FOR BOTHPORT AND STB LIFEBOATS TO INCLUDE, BUT NOT LIMITED TO, REPAIRS OF SHELL- INNER DECK(SEPARTION), ALL HAND RAILS, CONDITION AND REPLACEMENT OF FLOTATION AND DRILLED HOLES IN KEELS(4 EA. PER BOAT).
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Fire Fighting
Issued 26 July 1993 Resolved
MAKE TEMPORARY REPAIRS TO WATER CURTAIN PIPING, REPAIR SOFT PATCH, HOLE IN PIPING ON STB SIDE MAINFOLD, HOLE IN PIPING ON AFT COMPRESSOR ROOM BULKHEADAND HOLE IN PIPING ON PORT SIDE MAINFOLD. UPON COMPLETION TEST TO WORKING PRESSURE IN PRESENCE OF A MARINE INSPECTOR
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993
Fire Fighting
Issued 26 July 1993 Resolved
MAKE PERMANENT REPAIRS TO WATER CURTAIN SYSTEM PIPING, THAT HAVE BEEN TEMPORARY REPAIRED BY ITEM 01. AFTER REPAIRS HYDRO PIPING TO 1.5 TIMES MAWPIN PRESENCE OF A MARINE INSPECTION_x001C_
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Unknown
Issued 22 June 1990 Resolved
REPLACE THE FOLLOWING NON-METALLIC EXPANSION JOINTS: S.W. SERVICE SUCTION & DISCHARGE, MAIN L.O. COOLFR OUT AUX COND X-OVER, BOTH L.O. COOLFR INLETS,L.O. COOLFR OUT AND NO.1 AUX CIRC PUMP SUCTION.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 22 June 1990 Resolved
PROVIDE COAST GUARD APPROVED PLANS OR APPROVAL LETTER FOR WHEEL HOUSE SLID-ING DOOR FASTNERS. SHOULD SAME NOT BE GIVEN APPROVAL, FASTNERS SHALL BE REMOVED IMMEDIATELY UPON NOTIFICATION.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 22 June 1990 Resolved
REPLACE WITH CURRENT/WITH-IN SERVICE DUF DATE FORWARD INFLATEABLE LIFERAFT.REPLACEMENT SHALL BE CAPABLE OF CARRYING AT LEAST 10 PERSONS.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 24 January 1990 Resolved
SERVICE ALL PORTABLE, SEMI-PORTABLE AND FIXED CONTROLS AND FIRE EXTINGUISHING SYSTEMS IN ACCORDANCE WITH 46 CFR 31.10-18 AND 31.10-18A.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 24 January 1990 Resolved
REPAIR OR REPLACE THE RELIEF VALVES FOR THE SSDG STARTING AIR BOTTLES TO RELIEVE AT OR BELOW THE MAWP OF THE BOTTLES.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 24 January 1990 Resolved
HYDRO TEST ALL FIRE HOSES IN ACCORDANCE WITH 46 CFR 31.10-12.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 24 January 1990 Resolved
REPAIR THE OILY WATER SEPARATOR SO THAT IT PROPERLY SAMPLES THE EFFLUENT FROM THE SEPARATOR. UNTIL THIS IS REPAIRED, ALL THE EFFLUENT MUST BE PUMPED INTO THE OILY WASTE TANK AND THE OVERBOARD VALVE MUST BE SECURED.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Unknown
Issued 27 December 1988 Resolved
REPAIR/REPLACE DEFECTIVE 15 PPM OIL CONTENT DETECTOR/ALARM UNIT. OPERATIONOF OWS OVERBOARD DISCHARGE IN AUTOMATIC MODE PROHIBITED UNTIL DETECTOR/ ALARM UNIT IS OPERATIONAL.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Lifesaving
Issued 27 December 1988 Resolved
DEMONSTRATE THAT KHI ALUMINUM WELD PROCEDURE SK-64-1 OF 11 FEB 1976 MEETS ALL APPLICABLE ASME CODE/CFR REQUIREMENTS, OR REQUALIFY IIL 5086-0 ALUMINUMWELD PROCEDURE FOR ASME CODE/CFR. REPAIR TO CARGO TANK #3 CONSIDERED TEMPORARY PENDING COMPLETION OF APPROVED WELD PROCEDURE QUALIFICATION.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Electrical
Issued 12 December 1987 Resolved
REPAIR OR REPLACE THE MISSING ACTIVATION LEVER CONNECTING ROD FOR THE STARBOARD LIFEBOAT EXTERIOR DISCONNECT BREAKER.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Lifesaving
Issued 12 December 1987 Resolved
REPAIR OR REPLACE THE BROKEN PORT LIFEBOAT EMBARKATION LADDER.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Deck/Cargo
Issued 12 December 1987 Resolved
PERMANENTLY REPAIR THE PATCHED INERT GAS GENERATOR AFTERCOOLER WATER SUPPLYLINE.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987 Resolved
PERMANENTLY REPAIR THE PATCHED HULL PROTECTION LNG SPILL WASHDOWN SUPPLY LINE AT THE STARBOARD SIDE CARGO MANIFOLD.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Lifesaving
Issued 12 December 1987 Resolved
PROVIDE A LIFERAFT DEPLOYMENT INSTRUCTION PLACARD FOR THE STBD RAFT.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Electrical
Issued 12 December 1987 Resolved
PERMANENTLY REPAIR THE BROKEN CABLE TRAY HANGER AND PIPE HANGER LOCATED IN THE VICINITY OF FRAME 73, PORT UNDERDECK TUNNEL.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987 Resolved
CONDUCT ANNUAL SERVICING OF THE SKID MOUNTED ANSUL DRY CHEMICAL EXTINGUISHERS. PROVIDE A COPY OF THE SERVICE CERTIFICATE TO THE [name withheld], HI.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987 Resolved
COMPLETE THE ANNUAL SERVICING OF THE FIXED CO2 SYSTEM, INCLUDING HYDRO- STATIC TESTING OF ANY CYLINDER WHICH HAS NOT BEEN TESTED WITHIN PRECEDING 12 YEARS. PROVIDE [name withheld], WITH A COPY OF THE SERVICE CERTIFICATE.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Fire Fighting
Issued 12 December 1987 Resolved
COMPLETE AN ANNUAL SERVICING OF SEMI-PORTABLE AND PORTABLE DRY CHEMICAL ANDCO2 EXTINGUISHERS, INCLUDING HYDROSTATIC TESTING OF ALL PORTABLE CO2 CYLINDERS WHICH HAVE NOT RECEIVED SUCH TESTING WITHIN THE PREVIOUS 5 YEARS.PROVIDE [name withheld] WITH A COPY OF THE SERVICE CERTIFICATE.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Deck/Cargo
Issued 12 December 1987 Resolved
REPAIR OR REPLACE THE INOPERATIVE ROTATOR UNIT FOR THE STARBOARD SIDE "GAS IN CCR" ALARM BEACON.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Electrical
Issued 12 December 1987 Resolved
PERMANENTLY REPAIR THE PATCHED SSTG SALT WATER COOLING LINES AT ENGINE ROOM12 FOOT LEVEL, FRAME 44, PORT OVERHEAD; ENGINE ROOM 17 FOOT LEVEL, FRAME 38PORT OVERHEAD; AND ENGINE ROOM 12 FOOT LEVEL, FRAME 50, PORT SIDE NEAR #1 AUXILIARY CONDENSER.
Condition: Unknown
Due 12 December 1987
Resolved 12 December 1987
Deck/Cargo
Issued 27 December 1986 Resolved
REMOVE ANY PAINT, SILICON, UNAUTHORIZED GASKET OR WRAP FROM BETWEEN AND AROUND THE CONTACT POINT BETWEEN THE COVER AND EXPLOSION PROOF ELECTRICAL JUNCTION BOX FOR ALL SUCH JUNCTION BOXES IN THE FOLLOWING LOCATIONS: CARGOTANK DOME TOPS, CARGO TANK CATWALK, PORT & STBD CARGO MANIFOLDS (CONTINUED)
Condition: Unknown
Due 27 December 1986
Resolved 27 December 1986
Deck/Cargo
Issued 27 December 1986 Resolved
(CONTINUED FROM ABOVE) AND IN AND AROUND THE CARGO COMPRESSOR ROOM. TO BECOMPLETED PRIOR TO LOADING CARGO.
Condition: Unknown
Due 27 December 1986
Resolved 27 December 1986
Unknown
Issued 1 November 1985 Resolved
HAVE ALL FIRE EXTINGUISHING SYSTEMS AND EXTINGUISHERS SERVICED, AND FURNISHA COPY OF THE SERVICING CERTIFICATES TO THIS OFFICE.
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.