Records from 2016 to 2025. Most recent: inspection, 17 July 2025.
Inspection history · 11
17 July 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192127
13 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710888
7 June 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7447680
9 September 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7308465
26 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225136
7 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026526
10 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6714059
8 June 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6568958
14 June 2017
Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162501
27 September 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6007947
13 June 2016
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5917030
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2025
No resolution recorded
Remote fuel shutoff stations must be marked with legible 1 inch lettering indicating purpose of the valve and direction of operation. Enclosure for the Fuel Shut-off valve was not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2025 — due date passed with no resolution recorded
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2017
Resolved
Provide visual light at operating station for auto actuated bilge pump IAW 46CFR182.530.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: Visual indicator for automatic bilge pumps have been corrected to illuminate at the operating console when pump is operating.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 June 2017
Resolved
Install handles for four sliding windows in main passenger compartment that also serve as emergency exits.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: 04 handles have been installed on the sliding windows in the main passenger cabin.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2017
Resolved
Install 60' of bouyant lifeline to ring life buoy IAW 46CFR181.30.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: 60' of buoyant life line has been purchased for installation on life ring buoy.
Construction/Loadline › Hull › Stiffener
Issued 27 September 2016
Resolved
Internal backing block outboard and port of engine covering old trailering-related damage to hull is warped and delaminating, due to water intrusion. Crop and renew failed block to original scantlings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 14 June 2017
Resolution: Verified repairs were made, all sat.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2016
Resolved
Middle compartment automatic bilge pump does not have a visual indicator light at the operating station as required by 46CFR182.530(c)
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 13 June 2016
Resolution: Visual indicator light was installed at the operating station console to indicate automatic pump operation.