MAURY USCG vessel records
← All vessels

EVER URANUS

EVER URANUS is a 1999 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in November 2021, along with 3 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 5 November 2021.

Built
1999
Last inspected
5 November 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 November 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9168855
497909
Flag
PANAMA
Maury page id
psix-497909

Documentation record

Tonnage as PSIX records it30235 - Convention (Subpart B), Net Ton
63216 - Dead Weight, Ton
87544 - Displacement, Ton
69246 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

5 November 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7344909
17 September 2021 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7314558
14 September 2021 COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7312454
11 February 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6623659
26 July 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5948224

Deficiency record · 3

Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 26 July 2016 Resolved
1410 - Propulsion Main Engine - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. The connection for high pressure fuel line to # 6 cylinder leaking. 74SOLAS(04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2016
Resolution: The fuel line to the main engine injector # 6 located atop the cylinder cover was disassembled to address a leaking joint/seal, re-assembled, tested and considered satisfactory. The protective shield was then re-installed.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 26 July 2016 Resolved
0650 - Lifebuoys - Not less than two lifebuoys shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. The vessel only has one self-activing smoke signal attached to the lifebuoys on the navigation bridge. 74SOLAS(2014) III/7.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2016
Resolution: A new smoke signal of model IKAROS Man Overboard Smoke MK IV valid from 01/2015 thru 04/2019 and with MED Cert. Notified Body stamp # 0062/15 was installed with the buoy.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 26 July 2016 Resolved
1420 - Cleanliness of E/R - Buckets, pans, and plastic tarp containing oil found on multiple points for main engine leaks, potentially creating a fire hazard. 74SOLAS(2004) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2016
Resolution: All areas were found cleaned and house keeping appeared in order. The buckets, plastic and other clean up materials were cited. The Chief Engineer advised they had been doing some engine cleaning. Deficiency # 03 is considered rectified.

Ownership record