02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
A vessel must comply with the structural design requirements of Lloyd's Yachts and Small Craft. During vessels scheduled hull and internal structural examinations significant amounts of structural deterioration were identified. With the agreement of the owner the examinations were suspended to allow the owner time to consult a shipwright.
Provide repair proposal for rotten hood end of plank on stbd side 02 planks above the chine approximatively 12 feet from the bow.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: Scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
Provide repair proposal to make collision bulkhead watertight, and structurally sound. Light was observed passing through the blkd on the stbd side. Vertical stiffeners were no longer fastened to the blkd and were loose.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: Scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
Provide repair proposal addressing wasted internal fasteners in void #2. At least 25 fasteners (through bolts in frames) were found completely wasted. Most of the wasted fasteners were in the frames iwo the chine.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: Scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
Provide repair proposal addressing the chine frames pulling away from the hull in void #2.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: Scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
Provide repair proposal for the replacement of rotten engine bed on stbd inboard engine longitudinal stringer.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: Scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
During the internal examination of the engine room many of the deck beams were found with varying degrees of rot. The worst rot was found in the forward 2 deck beams but many (at least 05) require the "angle hair" be removed in order fully evaluate the condition of the deck beam. Provide repair proposal for the replacement of the forward 02 rotten deck beams. Scrape and remove "angle hair" and rotten wood from all deck beams.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
Provide repair proposal for broken and rotten shelf on the port side engine room in way of the engine.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
During the internal examination of the engine room most of the frames at the chine were found rotten with wasted fasteners (at least 16). Provide repair proposal for the replacement of rotten frames and wasted fasteners on port and stbd side of the engine room in way of the chine.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
During the outer hull walk approximately 30% of the vessels caulk was missing. At various places through internal hull exam, light could be observed entering the vessel at or below the water line. Reef and re-caulk all missing caulk and make hull watertight.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2022
Resolution: scrapped
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2020
Resolved
The hull and internal structural exams were suspended after completing the engine room in order to allow the vessel owner the opportunity to consult with a shipwright. In order to complete the hull and internal structural examinations all CG-835's need to be addressed to the satisfaction of an attending marine inspector and the internal structural exam needs to be completed in the MSD void and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 31 December 2020
Resolved 1 March 2021
Resolution: scrapped
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 August 2020
Resolved
Plank seams in E/R is missing calking.
Action required: 10 - Deficiency Rectified
Due 12 August 2020
Resolved 12 August 2020
Resolution: The seam was reamed and re-caulked.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 12 August 2020
Resolved
Re-seal MSD blkd penetration in aft engine room blkd.
Action required: 10 - Deficiency Rectified
Due 12 August 2020
Resolved 12 August 2020
Resolution: Penatration re-sealed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 April 2019
Resolved
Provide updated Coast Pilot and Light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 7 May 2019
Resolution: Updated Coast Pilot and Light list.
Lifesaving › Hand Flares › Quantity
Issued 17 May 2018
Resolved
Provide 6 hand red flares red or orange smoke distress signals.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 4 June 2018
Resolution: Distress signals provided.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 May 2017
Resolved
Secure hole in collision bulk head.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: Repaired.
Construction/Loadline › Hull › Side Shell
Issued 8 May 2017
Resolved
Repair leak in STBD plank in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: leak repaired.
Construction/Loadline › Hull › Side Shell
Issued 8 May 2017
Resolved
Repair leak in engine room FWD bulk head by chime panel
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: repair completed.
Construction/Loadline › Hull › Side Shell
Issued 8 May 2017
Resolved
Light was seen coming through hull PS engine room AFT 3 planks above chime. Adjacant to battery box.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 25 May 2017
Resolution: repaired.
Communications › Radio Communications › EPIRB
Issued 8 May 2017
Resolved
Provide documentation for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 8 May 2017
Resolution: Documentation provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 May 2017
Resolved
Repair fire buoy engine shut off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: test completed
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 8 May 2017
Resolved
PS eng pump cooling leaking.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 25 May 2017
Resolution: repaired.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 May 2016
Resolved
Replace 13 adult life jackets.
Condition: Improper/Lack of Maintenance
Due 2 May 2016
Resolved 2 May 2016
Resolution: 13 adult life jackets replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2016
Resolved
Replace battery in lifefloeat and ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 16 May 2016
Resolution: Battery replaced
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 2 May 2016
Resolved
replace cooling hose on STBD MDE
Condition: Improper/Lack of Maintenance
Due 2 June 2016
Resolved 16 May 2016
Resolution: Hose replaced.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 May 2016
Resolved
Secure bracket on PORT MDE alternator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 16 May 2016
Resolution: Bracket tightened.
Lifesaving › Hand Flares › Expired
Issued 2 May 2016
Resolved
Provide 6 distress flares.
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 16 May 2016
Resolution: flares installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2016
Resolved
Provide aspirin for first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 16 May 2016
Resolution: aspirin installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 May 2016
Resolved
Provide light list and coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 16 May 2016
Resolution: Light list provided.