Records from 1999 to 2025. Most recent: inspection, 17 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
17 July 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8193890
13 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710892
20 September 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7575387
7 June 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7447703
9 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225159
7 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026515
10 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713864
11 June 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6558808
28 September 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6264413
14 June 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162548
13 June 2016
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5917074
21 June 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4887864
6 June 2012
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4335710
14 September 2011
Simplified Stability Test
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4155854
20 July 2011
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4077948
21 January 2009
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3397869
18 June 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3328142
24 October 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3086163
5 June 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2952265
20 July 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2719386
26 August 2005
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2475664
29 June 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2196734
18 June 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1914056
18 June 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1612628
22 June 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1068271
14 June 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1440352
10 June 1999
Initial Certification · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1453621
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 July 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. marine inspector noted safety cotter pin missing from manual actuation handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 13 August 2025
Resolution: O/o provided picture of installed manual activation pin.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 July 2025
No resolution recorded
Each life float must be fitted with two paddles; each paddle must be lashed to the life float to which it belongs and buoyant. Marine inspector noted both paddles were not lashed to the life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2018
Resolved
Vessel to provide 01 additional fire bucket with lanyard
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 10 June 2019
Resolution: Vessel has required fire buckets
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2017
Resolved
Provide visual light at operating station for auto actuated bilge pump IAW 46CFR182.530.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: Visual indicator for automatic bilge pumps have been corrected to illuminate at the operating console when pump is operating.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 14 June 2017
Resolved
Replace/Recharge portable B-II fire extinguisher due to low charge IAW 46CFR176.810.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 28 June 2017
Resolution: Fire extinguisher replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2017
Resolved
Install 60' of buoyant life line to life ring buoy IAW 46CFR181.30.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: 60' of buoyant life line has been purchased for installation on life ring buoy.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 June 2017
Resolved
Install handles for four sliding windows in main passenger compartment that also serve as emergency exits.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: 04 handles have been installed on the sliding windows in the main passenger cabin.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 14 June 2017
Resolved
Install anchor of appropriate weight and size with sufficient line or chain for vessels operating area IAW 46CFR184.300.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 28 June 2017
Resolution: Anchor and line installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2016
Resolved
Twist on type wire nuts used for middle compartment bilge pump wiring. Replace with pressure type wire connectors IAW 46CFR183.340(g).
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 13 June 2016
Resolution: Twist on type wire nuts were replaced with pressure type connectors.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2016
Resolved
. Middle compartment automatic bilge pump does not have a visual indicator light at the operating station as required by 46CFR182.530(c).
Due 13 June 2016
Resolved 13 June 2016
Resolution: Visual indicator light was installed at the operating station console to indicate automatic pump operation.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 July 2011
Resolved
Mark lifejacket stowage to indicate number in compartment.
Due 3 August 2011
Resolved 3 August 2011
Resolution: Life jacket stowage has been properly marked.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 20 July 2011
Resolved
Properly install and equip buoyant apparatus.
Due 3 August 2011
Resolved 3 August 2011
Resolution: Buoyant apparatus has been properly installed and equipped.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 July 2011
Resolved
Install metal brackets with gasketing on all fuel lines and wire runs.
Due 3 August 2011
Resolved 3 August 2011
Resolution: Wiring is properly secured.
Fire Fighting › Fire Bucket › Availability
Issued 20 July 2011
Resolved
Acquire an additional 2.5 gallon firebucket.
Due 31 July 2011
Resolved 31 July 2011
Resolution: Additional fire bucket has been acquired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2007
Resolved
Provide a visual indicator at the operating station for all installed automatic bilge pumps.
Due 1 May 2008
Resolved 18 June 2008
Resolution: corrected
Lifesaving › Buoyant Apparatus › Painter
Issued 5 June 2007
Resolved
Attach painter to allow IBA to auto inflate and float free.
Due 18 June 2007
Resolved 18 June 2007
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 5 June 2007
Resolved
Provide painter and weak link for life foat.
Condition: Improper Installation
Due 18 July 2007
Resolved 16 October 2007
Lifesaving › Buoyant Apparatus › Float Free
Issued 5 June 2007
Resolved
Remove line securing life float to cabin top and install in a float free condition.
Condition: Improper Installation
Due 18 July 2007
Resolved 16 October 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 June 2007
Resolved
Prove annual fixed fire extinguishing system servicing.
Condition: Improper/Lack of Maintenance
Due 18 July 2007
Resolved 18 June 2008
Resolution: corrected
Operations/Management › Drills/Instruction › Abandon Ship
Issued 20 July 2006
Resolved
establish vessel specific procedures for abandon ship and flood control and drill all crew
Daily checks of bilge alarms and pumps need to be recorded prior to operation each day
Due 20 July 2006
Resolved 18 June 2007
Construction/Loadline › Structures › Door
Issued 20 July 2006
Resolved
locate and identify emergency exits from passenger area
Due 20 July 2006
Resolved 18 June 2007
Lifesaving › Buoyant Apparatus › Not on Board
Issued 20 July 2006
Resolved
Investigate and propose a procedure to rescue passengers from vessel in the event of sinking
Due 20 July 2006
Resolved 18 June 2007
Resolution: Installed one 15 person LF and one 25 person IBA.
Electrical
Issued 14 June 2000
Resolved
SECURE BATTERIES IN ENGINE COMPARTMENT
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 14 June 2000
Resolved
PROVIDE A LADDER TO ASSIST IN MAN OVERBOARD RETRIEVAL.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Fire Fighting
Issued 14 June 2000
Resolved
REINSTALL FIXED FIREFIGHTING BOTTLE SO THAT IT DISCHARGES DIRECTLY INTO ENGINE COMPARTMENT.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Documentation
Issued 14 June 2000
Resolved
POST STABILITY LETTER
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 10 June 1999
Resolved
PROVIDE 3 DAY AND 3 NIGHT APPROVED VISUAL DISTRESS SIGNALS WITH BRIGHTLY COLORED WATERTIGT CONTAINER.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Lifesaving
Issued 10 June 1999
Resolved
LABEL LOCATION OF FIRST AID KIT.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Fire Fighting
Issued 10 June 1999
Resolved
PROVIDE MANUAL ACTUATOR FOR ENGINE SPACE FIXED FIRE SUPPRESSION SYSTEM.
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Fire Fighting
Issued 10 June 1999
Resolved
PROVE PROPER OPERATION OF ENGINE SHUTDOWN FOR ENGINE SPACE FIRE SUPPRESSIONSYSTEM.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999