Records from 2016 to 2025. Most recent: inspection, 17 July 2025.
Inspection history · 11
17 July 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8193890
13 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710892
20 September 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7575387
7 June 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7447703
9 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225159
7 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026515
10 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713864
11 June 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6558808
28 September 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6264413
14 June 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162548
13 June 2016
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5917074
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 July 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. marine inspector noted safety cotter pin missing from manual actuation handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 13 August 2025
Resolution: O/o provided picture of installed manual activation pin.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 July 2025
No resolution recorded
Each life float must be fitted with two paddles; each paddle must be lashed to the life float to which it belongs and buoyant. Marine inspector noted both paddles were not lashed to the life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2018
Resolved
Vessel to provide 01 additional fire bucket with lanyard
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 10 June 2019
Resolution: Vessel has required fire buckets
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2017
Resolved
Provide visual light at operating station for auto actuated bilge pump IAW 46CFR182.530.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: Visual indicator for automatic bilge pumps have been corrected to illuminate at the operating console when pump is operating.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 14 June 2017
Resolved
Replace/Recharge portable B-II fire extinguisher due to low charge IAW 46CFR176.810.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 28 June 2017
Resolution: Fire extinguisher replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2017
Resolved
Install 60' of buoyant life line to life ring buoy IAW 46CFR181.30.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: 60' of buoyant life line has been purchased for installation on life ring buoy.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 June 2017
Resolved
Install handles for four sliding windows in main passenger compartment that also serve as emergency exits.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 23 June 2017
Resolution: 04 handles have been installed on the sliding windows in the main passenger cabin.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 14 June 2017
Resolved
Install anchor of appropriate weight and size with sufficient line or chain for vessels operating area IAW 46CFR184.300.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 28 June 2017
Resolution: Anchor and line installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2016
Resolved
Twist on type wire nuts used for middle compartment bilge pump wiring. Replace with pressure type wire connectors IAW 46CFR183.340(g).
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 13 June 2016
Resolution: Twist on type wire nuts were replaced with pressure type connectors.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2016
Resolved
. Middle compartment automatic bilge pump does not have a visual indicator light at the operating station as required by 46CFR182.530(c).
Due 13 June 2016
Resolved 13 June 2016
Resolution: Visual indicator light was installed at the operating station console to indicate automatic pump operation.