Records from 1983 to 2005. Most recent: inspection, 14 July 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
14 July 2005
Uninspected Other
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2426339
11 September 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388593
1 October 1997
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406188
1 April 1997
MARPOL Annex I Examination · Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466453
15 January 1997
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1413103
5 July 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1088363
15 March 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 885408
11 March 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 647454
26 April 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 862393
30 March 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 834778
15 March 1995
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 864686
23 December 1994
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167916
19 April 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 858232
31 March 1994
Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167764
17 November 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1159847
8 March 1993
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 836325
12 February 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 833369
12 February 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 835176
21 January 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1133684
14 December 1992
Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831133
1 June 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 954974
7 May 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 647455
8 April 1992
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 951853
16 December 1991
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1258682
17 May 1991
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 937882
24 January 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 911785
20 March 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1226993
31 January 1990
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1230474
12 December 1989
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 929750
12 May 1989
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1200896
3 January 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1348002
17 November 1988
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1205399
6 November 1987
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1004501
9 December 1986
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1022117
24 October 1986
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1315100
10 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 981515
10 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 981519
15 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 975168
19 September 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969735
14 July 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274238
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 September 1998
Resolved
Cover electrical wiring to lighting panel.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 11 September 1998
Resolved
Double clamp all raw water hoses to engine.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 September 1998
Resolved
Cut on deck access for fuel shut offs.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Lifesaving › Lifebuoys › Serviceable
Issued 11 September 1998
Resolved
Replace painter on lifefloat and ring buoy. No passengers may be carried until complete.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Hull › Hull Plating
Issued 11 September 1998
Resolved
SUBMIT FOR APPROVAL REPAIR PROPOSAL FOR SIDESHELL FRACTURES ON THE STARBOARD SIDE 1) IN WAY OF THE AFT OF THE PILOT HOUSE AND 2) TEN FEET FORWARD OF THE AFT OF THE PILOT HOUSE.
Condition: Unknown
Due 7 October 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 September 1998
Resolved
Provide covers to battery boxes.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 September 1998
Resolved
Service all fire extinquishers. No passengers may be carried until complete.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Hull › Hull Plating
Issued 11 September 1998
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, COMPLETE REPAIRS IN ACCORDANCE WITH APPROVED REPAIR PROPOSAL. SEE DEFICIENCY DEA1 OF CASE MI988027797.
Condition: Unknown
Due 7 October 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 September 1998
Resolved
Mount emergency checkoff and emergency broadcast placards.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 September 1998
Resolved
Repair masthead light. Day light ops only, until repaired.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Fire Bucket › Quantity
Issued 11 September 1998
Resolved
Provide 3 fire buckets._x001C_
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 1998
Resolved
Properly mount bilge pumps.
Condition: Unknown
Due 12 October 2004
Resolved 12 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 11 September 1998
Resolved
Replace worn retro tape on lifejackets.
Condition: Unknown
Due 5 October 2004
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline
Issued 1 October 1997
Resolved
Make repairs to the aft deck where cracked, at the attachment to the gunwale.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Construction/Loadline
Issued 1 October 1997
Resolved
Make repairs to aft gunwale in way of damage to gunwale where the cleat wasripped out.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Electrical
Issued 1 April 1997
Resolved
Replace missing connector on jumper wire connecting negative terminals of batteries
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Electrical
Issued 1 April 1997
Resolved
In accomodation space remove the plastic carrying cases used as electrical distribution panels and replace with proper UL marine equipment
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 1 April 1997
Resolved
Make repairs to bow where damaged, glass and epoxy
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Engineering
Issued 1 April 1997
Resolved
Replace port cutlass bearing
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Engineering
Issued 1 April 1997
Resolved
Replace both port and starboard strut bearings
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Engineering
Issued 1 April 1997
Resolved
Remove starboard strut, locate and repair damaged and leaking mounting
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Lifesaving
Issued 1 April 1997
Resolved
PROPERLY MARK PFD LOCATION AND AMOUNT AND ADULT.
Condition: Unknown
Due 30 May 1997
Resolved 4 June 1997
Lifesaving
Issued 1 April 1997
Resolved
SEPARATE AND MARK CHILDREN'S PFDS
Condition: Unknown
Due 30 May 1997
Resolved 4 June 1997
Lifesaving
Issued 1 April 1997
Resolved
INSTALL CLIP ON LIFE FLOAT LIGHT.
Condition: Unknown
Due 30 May 1997
Resolved 4 June 1997
Lifesaving
Issued 1 April 1997
Resolved
RE-RETRO TAPE LIFE FLOAT
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Lifesaving
Issued 1 April 1997
Resolved
INSTALL DECK RAILS
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Lifesaving
Issued 1 April 1997
Resolved
RETRO TAPE LIFE BUOY
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Lifesaving
Issued 1 April 1997
Resolved
MARK LOCATION OF FIRST AID KIT.
Condition: Unknown
Due 30 May 1997
Resolved 4 June 1997
Engineering
Issued 1 April 1997
Resolved
Replace throttle return springs on both engines
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Engineering
Issued 1 April 1997
Resolved
Remove wooden plug from port main diesel engine exhuast manifold and replace with proper metal plug.
Condition: Unknown
Due 19 April 1997
Resolved 1 April 1997
Lifesaving
Issued 1 April 1997
Resolved
PROVIDE AN EPRIB (ROUTE IS RESTRICTED TO LESS THAN 3NM UNTIL ONE IS PROVIDED.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Electrical
Issued 1 April 1997
Resolved
MAKE PROPER WIRE RUNS AND PROPERLY HANG ALL WIRING IN ENGINE ROOM. REMOVE NUMEROUS DEAD END WIRES, IMPROPER HOUSEHOLD TYPE WIRE NUTS SPLICES, HOUSEHOLD GRADE WIRING, IMPROPER BARE TWISTED WIRE USED AS SPICES._x001C_ _x001C_
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 1 April 1997
Resolved
INSTALL A PROPER ENGINE ACCESS HATCH. (present one is not weather/water tight and is loose on deck)
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Documentation
Issued 1 April 1997
Resolved
POST CURRENT RADIO CERT, EMERG BCST INST, COI, PFD DONNING INST, EMERG RADIO OPERATION INST, LICENSE ETC.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 1 April 1997
Resolved
MAKE OPERATIONAL FWD BILGE PUMP
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Engineering
Issued 1 April 1997
Resolved
STBD RAW WATER SYSTEM, DOUBLE CLAMP RUBBER HOSE BETWEEN THRU-HULL AND STRAINER.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Documentation
Issued 1 April 1997
Resolved
LOG MONTHLY DRILLS (FIRE, ABANDON SHIP) AND LOG WASTE (DISPOSAL MARPOL V)
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Navigation
Issued 1 April 1997
Resolved
PROPERLY ORIENT PIN IN STARBOARD STEERING ARM. PIN IS IN UPSIDE DOWN WITH COTTER PIN ON TOP.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Construction/Loadline
Issued 1 April 1997
Resolved
CLEAN AROUND BILGE PUMPS (AND CLEAN OUT LUMBER HOLES SO BILGE WATER DOES NOT COLLECT)
Condition: Unknown
Due 30 May 1997
Resolved 4 June 1997
Navigation
Issued 1 April 1997
Resolved
MAKE OPERATIONAL STBD RUNNING LIGHT
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Documentation
Issued 1 April 1997
Resolved
POST EMPLOYEE ASSIST PROGRAM INFO (1-800 NUMBER ETC) IN WORK PLACE.
Condition: Unknown
Due 1 April 1997
Resolved 1 April 1997
Engineering
Issued 15 January 1997
Resolved
Replace port main diesel engine exhaust manifold due exccessive corrosion and leaking exhaust.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 15 January 1997
Resolved
Make proper wire runs and properly hang all wiring in engine room._x001C_ Remove numerous dead ended wires, improper household type wire nut splices,househould grade wiring, improper bare twisted wire used as splices
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 15 January 1997
Resolved
Make proper splices to starboard main diesel engine (oil temp?) sensor
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 15 January 1997
Resolved
Repair starboard rail and house amidships where cracked.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 15 January 1997
Resolved
Remove dead ended wir and properly splice wires coming out of starboard main diesel alternator.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Engineering
Issued 15 January 1997
Resolved
Replace port oil cooler housing due to severe wastage (corrosion)
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 15 January 1997
Resolved
Rewire main control station properly_x001C_ example - main bus wire hanging loose with improper connections, bare guagelight bulbs hanging free on wires, bare dead ended wires, unused wires, household wiring, improper splices
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Navigation
Issued 15 January 1997
Resolved
Replace pin in starboard steering arm properly_x001C_ Pin in upside down with cotter pin on top
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 15 January 1997
Resolved
Make proper electrical splices for aft bilge pump located in lazerette
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 15 January 1997
Resolved
Crop and renew all of main deck in way of area covering engine compartment
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 15 January 1997
Resolved
Repair hull/deck joint at port bow where cracked and separated.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 15 January 1997
Resolved
Repair hull/deck joint at starboard bow were damaged and 6 ft. section of ajoining toe rail.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 15 January 1997
Resolved
Remove rotted filler down to good fiber glass and reglass
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 15 January 1997
Resolved
Make repairs to swim step/man overboard recovery platform in way of replassing mising bolts and correcting serious corrosion problems
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 15 January 1997
Resolved
Replace connection for starboard main diesel engine starter_x001C_ Wire fell out of crimped connection
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Engineering
Issued 15 January 1997
Resolved
Replace port main diesel engine motor mounts_x001C_ 2" x2" angle iron completely wasted with less than 25% of the metal remaining
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Fire Fighting
Issued 15 March 1996
Resolved
Provide on board all the required portable fire extinguishers and provide for review the fire extinguisher servicing report.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Lifesaving
Issued 15 March 1996
Resolved
Lash both 4 foot paddles to the vessel's life float.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Lifesaving
Issued 15 March 1996
Resolved
Mark the vessel's life float with the person capacity.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Accommodation/Occupational Safety
Issued 15 March 1996
Resolved
Repair and or renew the marine sanitation device's holding tank overboard discharge valve.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Lifesaving
Issued 15 March 1996
Resolved
Provide on board all required distress signals in accordance with 46 CFR Part 180.35-5. Vessel did not have any pyrotechnic distress signals on board.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Electrical
Issued 15 March 1996
Resolved
Replace the protective cover over the electrical panel located in the vessel's head.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 15 March 1996
Resolved
Provide two (2) flashlights for emergency lighting.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 15 March 1996
Resolved
Replace the screw cap type splices with crimp type wire splices noted in the electrical panel located in the vessel's head.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Lifesaving
Issued 15 March 1996
Resolved
Remark the children's life preserver stowage locker.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 15 March 1996
Resolved
Free up the locking mechanism for both main deck Bowman flush deck hatch covers.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Electrical
Issued 15 March 1996
Resolved
Renew the ground wires from both main diesel engines to the vessel's grounding strap.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Construction/Loadline
Issued 15 March 1996
Resolved
Repair FRP damage noted to the port and starboard toe rails and the overhead at the port side storm rail.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Construction/Loadline
Issued 15 March 1996
Resolved
At the next required dry docking, renew all deck beams and the wood deck over the entire engine compartment. Advanced stages of wood rot noted in sveral locations.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Construction/Loadline
Issued 15 March 1996
Resolved
Provide and install a six (6) foot length of hose on the portable hand operated bilge/fire pump.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Documentation
Issued 15 March 1996
Resolved
Vessel is restricting from operating more than 1000 feet from shore until avalid FCC Safety Certificate is on board.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Lifesaving
Issued 15 March 1996
Resolved
Clean engine space bilges of all oil and oily residues.
Condition: Unknown
Due 15 March 1996
Resolved 18 March 1996
Documentation
Issued 15 March 1995
Resolved
Submit written proof of a chemical testing program which complies wth Title46 CFR, Part 16 to USCG Resident Inspection Office St. Croix._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Lifesaving
Issued 15 March 1995
Resolved
Vessel is limted to carrying 27 adults until one replacement adult size life preserver is provided for a total of 28 adult size life preservers.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Accommodation/Occupational Safety
Issued 15 March 1995
Resolved
Vessel is limted to 21 passengers until fixed seating is provided for a total of 26 passengers. Title 46 CFR 176.01-25._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Navigation
Issued 15 March 1995
Resolved
Repair the 360 degree white masthead light. 1972 COLREGS, Annex I, Rule 22. Vessel is limted to daylight operations until repairs are made.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Engineering
Issued 23 December 1994
Resolved
Renew the starboard side cutlass bearing.
Condition: Unknown
Due 23 December 1994
Resolved 5 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Renew all wasted nuts and bolts supporting the transom dive platform.
Condition: Unknown
Due 23 December 1994
Resolved 5 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Make operable the closure devices for both flush deck hatches.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Renew the 1 1/4" gate valve for the MSD discharge line.
Condition: Unknown
Due 23 December 1994
Resolved 5 January 1995
Electrical
Issued 23 December 1994
Resolved
Replace wire nuts with U.L. approved compression wire splices in way of thebilge pump located in the compartment forward of the steering compartment.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Accommodation/Occupational Safety
Issued 23 December 1994
Resolved
Renew safety cable for transom opening.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Repair the starboard toe-rail in way of previous repairs that were made during last drydocking.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Tighten fasteners in bow compartment that connect hull to deck cap.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Cap off bilge line manifold in engine comparment that is no longer is use.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Make proper repairs to FRP deck beam brackets 4, 5 and 6 which are pulling away from the FRP side shell in engine compartment on port side,
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
Plug or cover the two 1" holes located near the centerline of the forward bulkhead in engine compartment.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
In engine compartment on port side in way of side shell, prperly terminate through hull that is no longer in use.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Construction/Loadline
Issued 23 December 1994
Resolved
In engine compartment, scrape away all furry wood and treat surface with a wood preservative.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Electrical
Issued 23 December 1994
Resolved
Replace all wire nuts with U.L. approved compression wire splices in way ofthe bilge pump located in the steering compartment.
Condition: Unknown
Due 23 January 1995
Resolved 24 January 1995
Electrical
Issued 31 March 1994
Resolved
PROVIDE PROPER ELECTRIC WIRE SUPPORT BRACKETS & RERUN WIRE AS NECESSARY TO REMOVE ELECTRICAL WIRE FROM HANGING LOOSELY THROUGHOUT ENGINE ROOM.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Construction/Loadline
Issued 31 March 1994
Resolved
REMOVE DELAMINATED FIBERGLASS ON THE MAIN DECK AND ON THE AFT BULKHEAD OF THE HEAD AND PRESENT FOR INSPECTION BEFORE CONDUCTING REPAIRS.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Electrical
Issued 31 March 1994
Resolved
PROPERLY MOUNT LIGHT/SWITCH COMBINATION IN ENGINE ROOM.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Navigation
Issued 31 March 1994
Resolved
PROVIDE AND INSTALL SUPPORTS FOR HYDRAULIC LINES IN LAZARETTE.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Construction/Loadline
Issued 31 March 1994
Resolved
REMOVE AND PROPERLY REATTACH UNDER DECK SUPPORT BRACKETS. #2, #3 PORT, AND #2 STBD FROM FORWARD BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Construction/Loadline
Issued 14 December 1992
Resolved
Crop and renew as original all rotted areas of plywood bulkhead between steering gear space and ballast tank space.
Condition: Unknown
Due 14 December 1992
Resolved 14 December 1992
Construction/Loadline
Issued 14 December 1992
Resolved
Re-tab all underdeck longitudinal frames located in the ballast tank space where they penetrate the bulkheads.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Construction/Loadline
Issued 14 December 1992
Resolved
Make permanent repairs to damaged side shell and toe rail at starboard bow.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Construction/Loadline
Issued 14 December 1992
Resolved
Grind out cracked fiberglass on vertical side shell box supports located incockpit. Renew as original.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Accommodation/Occupational Safety
Issued 14 December 1992
Resolved
Reweld cracked and eroded welds on swim platform in way of boarding ladder.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Electrical
Issued 14 December 1992
Resolved
Provide cover for battery box.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Construction/Loadline
Issued 14 December 1992
Resolved
Crop and renew outboard-most plywood decking above ballast tank space and engine room where rotted on port and starboard sides. Re-laminate the plywood decking as original.
Condition: Unknown
Due 14 December 1992
Resolved 14 December 1992
Construction/Loadline
Issued 14 December 1992
Resolved
Re-glass bottom transverse framing where it has delaminated from the wood.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Construction/Loadline
Issued 14 December 1992
Resolved
In the engine room, re-tab all underdeck transverse frame brackets on the side shell where they are loose.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Construction/Loadline
Issued 14 December 1992
Resolved
Remove all "angel hair" from framing in the engine room. Treat wood framing to prevent recurrence.
Condition: Unknown
Due 20 March 1993
Resolved 8 March 1993
Lifesaving
Issued 8 April 1992
Resolved
PROVIDE 11 ADDITIONAL ADULT PFD'S. VESSEL CAN CARRY NMT 17 POB UNTIL THIS REQUIREMENT IS CLEARED IAW 46CFR180.25.
Condition: Unknown
Due 21 April 1992
Resolved 18 June 1992
Construction/Loadline
Issued 8 April 1992
Resolved
AT NEXT VESSEL DRY DOCK MAKE PEMANENT REPAIRS TO GUNWALE IWO AFT STBD CORNER AT AND ALONG STERN MAIN DECK.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 8 April 1992
Resolved
AT NEXT VESSEL DRY DOCK MAKE PERMANENT REPAIRS TO FWD PORT SHEAR STRAKE.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Documentation
Issued 8 April 1992
Resolved
CONDUCT A STABILITY TEST ON THE VESSEL OR PROVIDE PROOF THAT A SATISFACTORYTEST HAS BEEN PERFORMED IAW 46CFR171.030.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Documentation
Issued 20 March 1990
Resolved
OBTAIN AND POST ONBOARD VESSEL VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Accommodation/Occupational Safety
Issued 20 March 1990
Resolved
MAKE PERMANENT REPAIRS AND REINSTALL BOW HAND RAIL. PASSENGERS ARE NOT ALLOWED ON FORE-DECK UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Accommodation/Occupational Safety
Issued 20 March 1990
Resolved
OBTAIN DIVERS BOARDING LADDER OR REINSTALL DIVING PLATFORM.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Lifesaving
Issued 17 November 1988
Resolved
STOW PFDS IN ACCORDANCE WITH 46CFR 180.25-10(A)
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Construction/Loadline
Issued 24 October 1986
Resolved
RENEW ROTTED SECTION OF DECK IN WAY OF THE MIDDLE AFT COMPARTMENT.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986