MAURY USCG vessel records Sign in
← All vessels

ARINAGA

ARINAGA is a 1999 freight ship. The Coast Guard has recorded 19 inspections since 1999, most recently in June 2016, along with 6 deficiencies and 2 operational controls.

Records from 1999 to 2016. Most recent: inspection, 4 June 2016.

Built
1999
Last inspected
4 June 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9200342 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
497944
Flag
LIBERIA
—
Maury page id
psix-497944

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (1999–2016)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16173 - Convention (Subpart B), Net Ton
54318 - Displacement, Ton
47263 - Dead Weight, Ton
25955 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

4 June 2016 PII Safety Exam · Ballast Water Examination · COE-Offshore · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5889131
16 July 2015 COE-Dockside
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5177969
3 July 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4073952
17 December 2009 ISPS II Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3651845
10 February 2009 Random ISPS/MTSA-No PSC
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3413932
7 February 2009 PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3403874
5 April 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2902232
19 July 2006 ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2717887
3 August 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2449802
26 December 2004 Random ISPS/MTSA/PSC · Spot Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2258889
10 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2256960
8 December 2004 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2255544
9 August 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2161181
4 August 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2155192
2 August 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2154045
30 September 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1917104
1 August 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1650877
5 March 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287830
5 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 430477

Deficiency record · 6

Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 5 April 2007 Resolved
Vessel's main engine is not working properly due to loss of piston compression. Vessel is required to provide class report to Sector LA/LB prior to departure verifying vessel's main engine is properly working. Solas 74 amended Chp II-I Reg 26 17A
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2007
Resolution: Rcvd report of satisfactory class survey.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 4 August 2004 Resolved
Main engine fresh water cooler sea water supply pipe has a pin hole leak. Make proper repairs to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2004
Resolved 9 August 2004
Resolution: Received class report from BV satisfying requirement.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 4 August 2004 Resolved
Vessel has 09 empty emergency escape breathing devices in contradiction to ships fire control plan requirements. Provide fully charged emergency escape breathing devices on board and stored according to fire control plan to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2004
Resolved 9 August 2004
Resolution: Received class report from BV satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 August 2004 Resolved
Oily Water Separator not operating properly due to burnt oil content meter power supply unit. Repair/replace oil content meter power supply unit and prove proper operation of oily water separator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2004
Resolved 8 December 2004
Resolution: 08 Dec 04: Received class report from BV stating deficiency has been rectified.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 30 September 2003 Resolved
Port and STBD Embarkation ladders wasted. Repair to the satisfaction of Class Surveyor or renew as original meeting the requirments of SOLAS 74a III/11.7. Repair or renew prior to leaving the Port of Baltimore.
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 30 September 2003
Resolution: Class Surveyor sent report attesting to proper repairs.
Construction/Loadline › Markings
Issued 1 August 2002 Resolved
LOADLINE NEEDS TO BE REPAINTED, IN VIOLATION OF ICLL 66. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2002
Resolved 5 August 2002
Resolution: CONDUCTED FOLLOW-UP ON VESSEL''S LOADLINE, WHICH WAS REPAINTED.

Ownership record