← All vessels
GOLD RIVER
Freight Ship · Bulk Carrier class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named GOLD RIVER
GOLD RIVER is a 1999 freight ship. The Coast Guard has recorded 16 inspections since 1999, most recently in January 2008, along with 3 deficiencies and 4 operational controls.
Records from 1999 to 2008. Most recent: inspection, 11 January 2008.
- Built
- 1999
- Last inspected
- 11 January 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9205603 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRYN7
497945
Flag
HONG KONG
—
Maury page id
psix-497945
Inspections, by type
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it32972 - Dead Weight, Ton
39712 - Displacement, Ton
19908 - Convention (Subpart B), Gross Ton
11044 - Convention (Subpart B), Net Ton
39712 - Displacement, Ton
19908 - Convention (Subpart B), Gross Ton
11044 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
11 January 2008
ISM Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3128674
9 October 2007
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3075837
30 September 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2504847
9 September 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2488371
20 April 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2338968
22 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2279272
21 January 2005
Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2278029
20 April 2004
NPV Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2048698
24 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1845685
22 April 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1778614
12 November 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1704336
22 May 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1619692
23 October 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 294967
17 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286051
13 July 2000
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 279632
23 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432073
Deficiency record · 3
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 30 September 2005
Resolved
Vessel failed to provide a 24 hour advance notice of arrival after leaving Philadelphia. Vessel must wait until 1937 hours on September 30, 2005 before proceeding to port.
Construction/Loadline › Structures › Air Pipe
Issued 20 April 2004
Resolved
Soft patch on piping. The pipe located above Heat Tank has rubber tape soft patch installed. A second pipe on the Aux. Condenser has a pin hole leak located aft side at 12 o'clock position. Repair both pipes to the satisfaction of the Safety Construction issuing authority prior to 04 May 2004.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 22 May 2002
Resolved
Master stated that he did not submit Ballast Water report to Coast Guard National Ballast Water Information Clearing House.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National