← All vessels
ENTERPRISE
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named ENTERPRISE
ENTERPRISE is a 1978 passenger vessel (inspected). The Coast Guard has recorded 99 inspections since 1985, most recently in October 2025, along with 170 deficiencies, 5 operational controls and 3 casualty investigations between 2012 and 2013.
Records from 1985 to 2025. Most recent: inspection, 25 October 2025.
- Built
- 1978
- Last inspected
- 25 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 170 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2012–2013
Identity
596049
WYB2848
49795
Flag
UNITED STATES
367095040
Maury page id
psix-49795
Inspections, by type
…with no type recorded6
Years with a record
40 calendar years (1985–2025)
The 99 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)76.3 ft × 24.7 ft × 5.3 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPEACOCKS BOAT BUILDING CO · WILMINGTON, CA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WYB2848MMSI 367095040 · active · compulsorily equipped · granted 5 June 2018, expires 30 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 99
25 October 2025
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8214137
6 May 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075374
28 January 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981997
12 October 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8008054
25 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7867605
12 October 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7804055
26 April 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7634195
14 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650833
14 February 2023
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610142
26 January 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627759
16 December 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610172
8 December 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606132
24 February 2022
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377152
9 October 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329219
12 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7173529
17 February 2021
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7141187
28 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6962574
27 February 2019
Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610161
22 February 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630768
7 December 2018
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622604
5 June 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6435475
13 April 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384240
27 November 2017
Deficiency Check · Annual Inspection
Physical examination · Navigation Center · Activity 6313556
1 March 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6070489
14 February 2017
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6069649
31 May 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5894964
26 April 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829485
8 September 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5238338
7 September 2015
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5238536
7 May 2014
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4835708
19 July 2012
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4384263
14 February 2012
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4000343
13 February 2012
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4243626
1 February 2012
Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4233247
18 February 2011
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3961545
7 January 2011
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3922843
23 March 2010
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3680557
16 March 2010
DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3696965
12 January 2010
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3636706
11 May 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3470344
14 April 2009
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3452694
6 April 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3448136
5 February 2009
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3413129
23 January 2008
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3126053
9 April 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2903068
12 March 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2870823
4 April 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594063
27 March 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2610488
4 January 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2561571
17 March 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2302823
12 March 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2023363
3 December 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1959535
18 March 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1759591
13 March 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1491690
27 November 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1473832
30 April 2001
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382335
3 April 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397617
30 March 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387017
28 March 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395407
21 December 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410217
24 March 1999
Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397113
24 March 1998
Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388493
15 April 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390498
6 September 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398529
22 April 1996
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1080617
16 April 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392436
23 October 1995
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 872093
25 April 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392212
28 March 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1468782
10 May 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169455
27 April 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168765
4 May 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149443
2 April 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149197
5 January 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 832532
12 May 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267596
25 November 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 943488
25 November 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253579
16 May 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220825
9 April 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1211537
16 July 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 903411
19 June 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928336
23 May 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908773
31 January 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1232471
2 January 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928356
21 December 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1217696
31 August 1989
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039637
22 June 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887420
6 June 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888765
20 January 1989
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205272
18 January 1989
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888494
14 June 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 891724
26 May 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886958
26 May 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1342077
23 July 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022417
14 July 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1017848
8 June 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1028534
9 June 1986
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991153
16 October 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994446
7 June 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983131
Deficiency record · 170
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2024
Resolved
Exhaust gas leaking from exhaust hose in steering lazarette. Fix exhaust gas leak. 46CFR182.05(a) Old T
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 October 2024
Resolved
Audible alarm sounds in pilot house but no visual for bilge high water
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2024
Resolved
Each survival craft must be ready for immediate use so that crew members can carry out preparations for embarkation and launching in less than 5 minutes. MI found life float and buoyant apparatus painter and grab lines tangled in a way that impedes immediate use.
180.130(a)(5)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found three overhead light fixture covers missing in bunk room.
46 CFR 183.200(b)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2024
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high.
When stowed in tiers, the separate units must be kept apart by spacers. Life floats and buoyant apparatuses found without spacers in between.
46 CFR 180.137(f)
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 25 March 2024
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding
the maximum load from wave and wind conditions. MI found
cracked window on bridge.
46 CFR 177.1020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet)in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Each floating waterlight on a vessel carrying only one ring buoy, musy be attached to the lanyard with a corrosion resistant clip. MI found ring life buoy with light not secured with a corrosion resistant clip.
46 CFR 180.70(d)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. MI found life jackets with the wrong vessel name.
46 CFR 185.604(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 February 2023
Resolved
Make ID'd bulkhead penetrations water tight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 February 2023
Resolved
MI found fwd and aft flush type hatches inoperable.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 February 2022
Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for life floats and buoyant apparatus must meet the follwing specifications: Lifeline and pendants. The lifeline and pendants must be furnished bu the manufacturer with the approved life float or buoyant apparatus. Replacement lifeline and pendants must meet the requirements in Subpart 160.010 of this chapter. Properly rig life float and buoyant apparatus onboard.
46 CFR 180.175(f)(1)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
46 CFR 183.430
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2022
Resolved
Each battery used in an item of lifesaving equipment except inflatable survival craft equipment must be replaced duringt he annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number.
46 CFR 185.726(d)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 April 2021
Resolved
Each vessel constructed of a material other than wood certificated to operate on a coastwise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel is certificated to carry 153 total person. Vessel has on board life saving for 104 total persons. Vessel is restricted to carrying 104 persons until they can satisfactorily provide life floats for 100% of total persons permitted on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI discovered the visual indicator for the forward galley compartment high water level alarm to not be operational. Vessel to prove proper operation of the visual indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI discovered float alarm activation switch to be mounted in such away that it inhibits proper operation. Vessel to mount the switch properly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 April 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI discovered fan blades to be completely uncovered. Vessel to provide proper guard for fan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards. MI discovered outlet in the galley space to have a piece broken off inside the outlet and generally be unsafe. Vessel to replace the unsafe outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI discovered 04 life jackets that did not have an operational clip for proper securing. Vessel to replace the 04 life jackets and is limited to 149 total persons on board until compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 April 2021
Resolved
Each life float must be fitted with two paddles; each paddle must be lashed to the life float. MI discovered the paddles for the vessel's 25 person life float to not be lashed to the life float. Vessel to properly lash the paddles to the life float.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 April 2021
Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently equipped to allow the crew to recover a helpless person from the water. MI determined that the rescue platform the crew uses to remove a helpless person from the water to be too corroded for safe use. Vessel to provide a satisfactory means to recover an unresponsive person from the water.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2020
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC type accepted category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB battery expired JAN2019, vessel is restricted from operating beyond 03 nautical miles from shore until battery is replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 February 2019
Resolved
Vessel stern light is found to be inoperable. Prove stern light is operable. Vessel is restricted to day time operations until deficiency is corrected.
Fire Fighting › Fire Pumps › Capacity
Issued 5 June 2018
Resolved
properly repair vessel fire pump to provide 50 gallons per minute at a pressure greater than 60 PSI. Vessel is no-sailed.
Documentation › Logs/Records › Logbook (official)
Issued 5 June 2018
Resolved
Ensure a written passenger count is available and logged both onshore and on vessel of all passengers.
Engineering › Lubricating Oil Service System › Pump
Issued 1 March 2017
Resolved
Repair oil leaks on generator and main engine.
Lifesaving › Lifebuoys › Stowage
Issued 1 March 2017
Resolved
Mount starboard ring lifebuoy so that it is readily accessible.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 March 2017
Resolved
Label 17 Adult/1 Child lifejacket with Vsl name so that it is clearly visible.
46CFR185.30-5
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 March 2017
Resolved
Replace retroreflective tape on 17 adult/1 child life jackets where indicated.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 March 2017
Resolved
CLearly mark stowage of lifejackets and post donning placard.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 March 2017
Resolved
Replace 1 missing adult lifejacket.
Lifesaving › Lifefloat › Float-free Link
Issued 1 March 2017
Resolved
Connect all Life floats to their weak links.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 February 2017
Resolved
Conduct permanent weld repairs to marine sanitation holding tank, both port & stbd.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 14 February 2017
Resolved
Remove all oil in engine room bilge to remove flammable hazards.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 April 2016
Resolved
Provide operable masthead light. Vessel is restricted to daylight operations until corrected. Make stern & masthead light visible to correct arc of visibility (135 degrees / 225 degrees).
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 26 April 2016
Resolved
Provide new stowage arrangement for waterlights of 03 buoyant apparatuses on top of wheelhouse, so that it does not interfere in launching.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 26 April 2016
Resolved
Provide now weak link with identification tag for the BA on top of wheelhouse.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2016
Resolved
Make all new wiring above wheelhouse secured with metal supports not more than 24" apart.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 April 2016
Resolved
Provide legible emergency instructions posted at the operating station.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 April 2016
Resolved
Log all fire, abandon ship, & MOB drills & make ready for CG review.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 April 2016
Resolved
Test & log EPIRB checks on monthly basis.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 April 2016
Resolved
Prove proper securing of MSD while within 3NM.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 April 2016
Resolved
Provide second hose clamp on exhaust piping in lazarette.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 April 2016
Resolved
Provide current crew list with all employees for DAPI.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 26 April 2016
Resolved
Renew severaly degraded retroreflective material.
Lifesaving › Buoyant Apparatus › Marking
Issued 26 April 2016
Resolved
[name withheld] with vessel name and persons capacity.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 April 2016
Resolved
Replace 06 unserviceable Kapok PFDs and provide 03 additional PFDs to fulfill required # per COI.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 April 2016
Resolved
Renew retroreflective material on 23 identified PFDs.
Lifesaving › Lifefloat › Paddle
Issued 26 April 2016
Resolved
Provide paddles for new lifefloat.
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 26 April 2016
Resolved
Arrange survival craft for logical deployment either by crew or automatically upon sinking.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2016
Resolved
Renew retroreflective material on ring (01) lifebuoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 8 September 2015
Resolved
Prove proper operation of main engine/start up.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 March 2012
Resolved
Replace expired batteries in lifefloat lights.
Documentation › Certificates/Documents › Stability Letter
Issued 5 March 2012
Resolved
Provide stability addendum in accordance with AAWPP from MSC.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 March 2012
Resolved
Make forward engine room bulkhead watertight.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 1 February 2012
Resolved
Renew cracked bridge windows.
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2011
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2011
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Electrical › Electric Generation Source (service) › Switch
Issued 23 March 2010
Resolved
Remove or cap dead end wires on genset fuel system.
Electrical › Electrical Distribution System (service) › Conductor
Issued 23 March 2010
Resolved
Secure all loose wires in cable runs.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 23 March 2010
Resolved
Replace anchor line. Line has areas that are worn through more than half way and is generally in bad condition.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 23 March 2010
Resolved
Secure loose anchors below decks. Make compartment ready for sea. Two spare anchors stowed below decks were sitting on deck next to missing deck plates. Possibility of anchor falling 2 feet into bilge and puncturing hull.
Stability › Unintentional Flooding › General
Issued 23 March 2010
Resolved
Cap old keel cooler piping under main engine. If cooler were to rupture, compartment will flood.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 March 2010
Resolved
Install fan guard on engine room supply fan.
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2009
Resolved
Company policy insufficient as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2009
Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Engineering › Steering Gear System › Ram
Issued 6 April 2009
Resolved
Hydraulic steering ram rod (port side unit) found leaking while at full rudder during steering gear test. Vessel required to repair or replace hydraulic steering ram, to the satisfaction of an attending CG marine inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 6 April 2009
Resolved
Crop and renew watertight bulkhead supports, ladder, and bilge athwartships support IAW 46CFR176.802, using NVIC 7-68 as a guide, in the vessel's forepeak.
Construction/Loadline › Hull › Transverse Frame
Issued 6 April 2009
Resolved
Crop and renew corroded athwartships frames as indicated in vessel's lazarette IAW 46CFR176.802, using NVIC 7-68 as a guide.
Lifesaving › Lifefloat › Paddle
Issued 6 April 2009
Resolved
Replace 02 paddles in vessel's life float arrangement IAW 46CFR180.175(d).
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 April 2009
Resolved
Install main engine exhaust lagging to cooling water injection IAW46CFR182.425(b)(2).
Communications › Radio Communications › EPIRB
Issued 6 April 2009
Resolved
Replace expired EPIRB battery IAW 46CFR180.64.
Stability › Watertight Integrity › General
Issued 6 April 2009
Resolved
Address water ingress from rudder post IAW 46CFR176.814.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 April 2009
Resolved
Mark vessel's name in clearly legible letters on all ring life buoys IAW 46CFR185.604(b).
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 March 2007
Resolved
Replace outlet cover under bridge helm console.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 March 2007
Resolved
Install proper stuffing tube for cable going into fuse box on bridge.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 12 March 2007
Resolved
Crop and renew ladder support to fwd peak to good metal
Electrical › Lighting (service) › Lighting Fixture
Issued 12 March 2007
Resolved
Replace globe for light fixture in sewage compartment.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 March 2007
Resolved
Provide wire supports (metallic) every 24" for cable in sewage compartment.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 12 March 2007
Resolved
Properly mount sewage pump.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 March 2007
Resolved
Provide cover for outlet box on mess deck.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 March 2007
Resolved
Provide enclosure for electrical cable splice in engineroom portside aft.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 March 2007
Resolved
Replace spliced cable for battery charger in engineroom
Engineering › Fuel Oil Service System › Filter
Issued 12 March 2007
Resolved
Remove fuel oil from fuel filter bowl in engineroom.
Documentation › Logs/Records › Drug Test Records
Issued 12 March 2007
Resolved
Provide proof of 1 hour EAP supervisor training.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 12 March 2007
Resolved
Provide rescue boat/platform to allow crew to recover helpless person in water.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 27 March 2006
Resolved
Repair damage to twin disk gear box. Vessel suffered minor engine failure when gasket in gear box was damaged.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 January 2006
Resolved
Clean, treat rust in lazarette.
Navigation › Electronic Positioning
Issued 12 March 2004
Resolved
Expired EPIRB battery
Documentation › Certificates/Documents
Issued 12 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electrical Distribution System (service)
Issued 13 March 2002
Resolved
Provide cover for open fuse box and distribution panel above bunk in pilot house. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Electrical
Issued 13 March 2002
Resolved
Provide single-line diagram of electrical system throughout vessel. Vessel seemed to have inadequate/missing circuit protection for bridge equipment. Additionally, ship's captain (Andrew) stated that they had been making several changes to the electrical system over time.
Electrical › Electric Generation Source (service)
Issued 13 March 2002
Resolved
Provide cover for generator set electrical box connections. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Engineering › Fuel Oil Storage/Transfer System
Issued 13 March 2002
Resolved
Provide adequate flame shields for fuel shutoff reach rods per 46 CFR 182.455(b)(4). LEGACY COMPONENT DESC: Fuel Shutoff Valves
Engineering › Pressure Vessel
Issued 13 March 2002
Resolved
Provide proof that air compressor meets ASME "U" or "UM" standards; Vessel's data placard did not show any ASME certification. If it does not, it will need to be replaced with an ASME "U" or "UM" approved cylinder. LEGACY COMPONENT DESC: Marking and Stamping
Lifesaving › Buoyant Apparatus
Issued 13 March 2002
Resolved
Place spacers between buoyant apparatus and lifefloats.
Lifesaving › Buoyant Apparatus
Issued 13 March 2002
Resolved
Two BA's were not stowed in a float-free arrangement; They were stowed underneath a metal frame for the RADAR and radio. This was corrected during the course of the inspection.
Lifesaving
Issued 13 March 2002
Resolved
Provide proof of current NOAA registration for EPIRB. LEGACY COMPONENT DESC: EPIRB
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 December 2001
Resolved
Replaced sewage holding tank overboard discharge valve.
Construction/Loadline
Issued 24 March 1999
Resolved
Install and prove proper operation of bilge high level alarms IAW 46 CFR 182.530.
Electrical
Issued 16 April 1996
Resolved
Replace all wire splices with approved wire connectors. Remove all wiring that is not in use.
Navigation
Issued 25 April 1995
Resolved
PROVIDE UPDATED LIGHT LIST AND COAST PILOT.
Electrical
Issued 27 April 1994
Resolved
REPLACE BULBS IN STERN, PORT AND FWD MAST LIGHTS WITH PROPER MARINE BULBS.
Lifesaving
Issued 27 April 1994
Resolved
PROVIDE 29 ADDITIONAL ADULT LIFEJACKETS.
Electrical
Issued 27 April 1994
Resolved
REWIRE AFT DECK LIGHTS.
Construction/Loadline
Issued 27 April 1994
Resolved
REMOVE OIL FROM BILGES.
Construction/Loadline
Issued 4 May 1993
Resolved
PROVIDE A MEANS OF PERMANENTLY SECURING THE LADDER INTO THE NO.3 BELOW DECKCOMPARTMENT.
Construction/Loadline
Issued 4 May 1993
Resolved
PROVE PROPER OPERATION OF THE ELECTRICAL AUXILIARY BILGE PUMP.
Engineering
Issued 4 May 1993
Resolved
RENEW THE FLAME SCREEN ON THE STARBOARD DIESEL FUEL TANK VENT.
Documentation
Issued 5 January 1993
Resolved
INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 45 CFR 185.30-3 PRIOR TO COMPLETION OF THE FIRST ROUTINE DRYDOCKING AFTER 01 JANUARY 1993.
Accommodation/Occupational Safety
Issued 12 May 1992
Resolved
REMOVE EXCESS GREASE BUILD-UP FROM GALLEY GRILL.
Lifesaving
Issued 12 May 1992
Resolved
POST SIGN PROHIBITING PASSENGER ACCESS TO UPPER DECK._x001C_
Accommodation/Occupational Safety
Issued 12 May 1992
Resolved
PROVIDE A TOTAL OF TWO (2) WASH BASINS FOR PASSENGERS.
Construction/Loadline
Issued 9 April 1991
Resolved
IN THE FOREPEAK: REPLACE UNDERDECK TRANSVERSE FRAMES AND LONGITUDINALS IN THE AREA OF HATCH OPENING AS MARKED IN CHALK.
Construction/Loadline
Issued 9 April 1991
Resolved
RENEW PIPING FOR BAIT SUCTION AFTER THE SEA VALVE TO THE 90 DEGREE ELBOW INTHE HOLDING TANK COMPARTMENT.
Electrical
Issued 9 April 1991
Resolved
REPLACE LAGGING ON GENERATOR EXHAUST.
Construction/Loadline
Issued 9 April 1991
Resolved
RESTENCIL MAXIMUM DRAFT MARKS ON BOTH PORT AND STBD QUARTER IN A CONSTRASTING COLOR FROM THAT OF THE HULL.
Engineering
Issued 9 April 1991
Resolved
RELOCATE REACH ROD FOR PORT SIDE EMERGENCY FUEL SHUT-OFF TO INBOARD SIDE OFBILGE PUMP PIPING.
Accommodation/Occupational Safety
Issued 9 April 1991
Resolved
RE-ATTACH TOP OF LADDER TO THE TOP OF THE MID-BODY COMPARTMENT UNDER THE GALLEY.
Electrical
Issued 9 April 1991
Resolved
REPAIR OR REMOVE ABANDONED OVERHEAD LIGHTING IN THE MID-BODY COMPARTMENT UNDER GALLEY.
Navigation
Issued 9 April 1991
Resolved
REPLACE PIN FROM STEERING GEAR RAM TO RUDDER YOKE ON STBD SIDE OF STEERING GEAR.
Engineering
Issued 19 June 1990
Resolved
REPLACE PVC PIPING IN BILGE DISCHARGE SYSTEM WITH METALLIC PIPING AS PER 46 CFR 182.40-5(B).
Fire Fighting
Issued 19 June 1990
Resolved
REPLACE FIRE HOSE WITH UL APPROVED RUBBER LINED FIRE HOSE AS PER 46 CFR 181.15-10(D).
Lifesaving
Issued 23 May 1990
Resolved
PROVIDE AN ADDITIONAL 27 ADULT LIFE PRESERVERS PRIOR TO ENGAGING IN WHALE WATCHING.
Electrical
Issued 23 May 1990
Resolved
REMOVE OR PROPERLY DEAD-END UNUSED WIRES UNDER BRIDGE CONSOLE.
Fire Fighting
Issued 23 May 1990
Resolved
REPAIR BROKEN GLASS ON FIREMAIN PRESSURE GAUGE.
Construction/Loadline
Issued 23 May 1990
Resolved
PROVIDE WATERTIGHT CLOSURES FOR EMERGENCY STEERING ACCESS AND PORT & STBD EMERGENCY FUEL CUT-OUT VALVE ACCESS.
Lifesaving
Issued 23 May 1990
Resolved
PROVIDE 25 ADULT LIFE PRESERVERS. TOTAL PERSONS ON BOARD SHALL BE LIMITED TO 74 UNTIL COMPLETION OF THIS ITEM
Engineering
Issued 23 May 1990
Resolved
PROVE PROPER OPERATION OF THE MECHANICAL BILGE PUMP POWERED BY THE MAIN ENGINE.
Engineering
Issued 23 May 1990
Resolved
PROVE PROPER OPERATION OF THE MAIN ENGINE LUBE OIL PRESSURE GAUGE IN THE PILOT HOUSE.
Electrical
Issued 23 May 1990
Resolved
PROVIDE GLOBES FOR LIGHTS IN BOTH HEADS AND OVER LADDER TO THE CREW COMPARTMENT.
Construction/Loadline
Issued 23 May 1990
Resolved
IN THE CREW COMPARTMENT - REPAIR/REPLACE BROKEN PORTLIGHT GLASS (PORT SIDE,AFT), REPAIR/REPLACE BROKEN PORTLIGHT DOG (STBD SIDE, AFT), AND PROVE PROPER OPERATION OF ALL PORTLIGHT DOGS.
Accommodation/Occupational Safety
Issued 23 May 1990
Resolved
PROVIDE CUT-OUT VALVES IN WATER SUPPLY TO EACH TOILET.
Accommodation/Occupational Safety
Issued 23 May 1990
Resolved
PROVE ADEQUATE WATER PRESSURE TO EACH WASH BASIN IN THE HEADS.
Navigation
Issued 23 May 1990
Resolved
PROPERLY SUPPORT HYDRAULIC HOSE AT THE STEERING GEAR.
Accommodation/Occupational Safety
Issued 23 May 1990
Resolved
PROPERLY SUPPORT TRANSVERSE DECK PLATE IN FRONT OF ENGINE ROOM BATTERY BOX.
Accommodation/Occupational Safety
Issued 23 May 1990
Resolved
REMOVE OR PROPERLY MOUNT GALLEY CROCK POT AND CHIP RACK.
Electrical
Issued 23 May 1990
Resolved
PROVIDE PROPER METALLIC SUPPORTS FOR ELECTRIC CABLES UNDER BRIDGE CONSOLE, ON BRIDGE, ON GALLEY DECK, IN ENGINE ROOM, AND IN FWD COMPARTMENT.
Electrical
Issued 21 December 1989
Resolved
REPAIR OPEN LIGHT SOCKET IN LAZARETTE AND INSTALL A PROPER COVER.
Construction/Loadline
Issued 21 December 1989
Resolved
PROPERLY REPAIR STARBOARD AFT CORNER SECTION OF MAIN DECK RAILING.
Construction/Loadline
Issued 21 December 1989
Resolved
PROPERLY WATERPROOF THREE HOLES AND ONE STUFFING TUBE IN AFT BULKHEAD OF FORWARD STORAGE AREA (NEAR BATTERY CHARGER).
Construction/Loadline
Issued 21 December 1989
Resolved
REMOVE WATER AND DEBRIS FROM BILGES IN THE FOREPEAK AND THE LAZARETTE.
Electrical
Issued 21 December 1989
Resolved
PROPERLY DRIP-PROOF THE TWO BATTERY CHARGERS (IN ENGINEROOM AND FORWARD STORAGE AREA).
Engineering
Issued 21 December 1989
Resolved
INSTALL PROPER FLAME DIFFUSERS ON THE FUEL OIL FILTERS FOR THE MAIN ENGINE.
Engineering
Issued 21 December 1989
Resolved
PROPERLY LABEL BILGE SUCTION VALVES AT THE BILGE MANIFOLD.
Engineering
Issued 21 December 1989
Resolved
INSTALL PLUGS IN DRAIN VALVES FOR THE PORT AND STARBOARD FUEL OIL TANKS ANDIN THE DRAIN VALVE FOR THE AFT LUBE OIL TANK.
Documentation
Issued 6 June 1989
Resolved
PROVIDE VALID STABILITY LETTER.
Lifesaving
Issued 6 June 1989
Resolved
MAKE UP PENDANTS OF PROPER LENGTH AND ATTACH RETROREFLECTIVE TAPE TO B/A'S.
Navigation
Issued 6 June 1989
Resolved
PERMANENTLY BOLT AIR COMPRESSOR IN SECOND COMPARTMENT.
Engineering
Issued 6 June 1989
Resolved
LABEL FUEL SHUT-OFF VALVES WITH ARROW INDICATING DIRECTION TO CLOSE.
Fire Fighting
Issued 6 June 1989
Resolved
PROVIDE HAND FIRE PUMP AND PROVE PROPER OPERATION.
Construction/Loadline
Issued 6 June 1989
Resolved
MAKE ENGINEROOM HATCH, PORT SIDE, WEATHERTIGHT.
Electrical
Issued 26 May 1988
Resolved
PROVIDE COVERS FOR 2 MOTOR CONTROLLERS IN THE ENGINEROOM.
Electrical
Issued 26 May 1988
Resolved
REPAIR KICK PIPE FOR THE ELECTRICAL WIRE AT VSL MAST.
Lifesaving
Issued 26 May 1988
Resolved
REPAIR GRAB LINE ON THE LIGHTED RING BUOY.
Lifesaving
Issued 26 May 1988
Resolved
PROVIDE A WATERTIGHT CONTAINER FOR DISTRESS SIGNALS.
Lifesaving
Issued 26 May 1988
Resolved
PROVIDE 3 WATER LIGHTS FOR THE VESSELS BUOYANT APPATATUS AND RING BUOY.
Lifesaving
Issued 26 May 1988
Resolved
PROVIDE PROPER PENDANT LINES FOR ALL 4 OF THE VESSEL'S BUOYANT APPARATUS.
Lifesaving
Issued 26 May 1988
Resolved
PROPERLY AND PERMANENTLY FIX THE VESSEL'S NAME TO THE BUOYANT APPARATUS.
Documentation
Issued 26 May 1988
Resolved
PROVIDE PROOF OF PROPER VESSEL DOCUMENTATION.
Engineering
Issued 26 May 1988
Resolved
LABEL EMERGENCY FUEL SHUTOFFS.
Fire Fighting
Issued 26 May 1988
Resolved
PROVIDE A 1.5" FIRE NOZZLE FOR #2 FIRE HOSE.
Accommodation/Occupational Safety
Issued 26 May 1988
Resolved
REPLACE LEAKING ENGINEROOM BILGE SUCTION PIPING.
Construction/Loadline
Issued 8 June 1987
Resolved
DRYDOCK THE VESSEL FOR COAST GUARD EXAMINATION.
Lifesaving
Issued 8 June 1987
Resolved
REPAIR SNAPS ON 5 ADULT LIFE JACKETS.
Fire Fighting
Issued 8 June 1987
Resolved
REPAIR FIREPUMP SO THAT IT WILL PROVIDE A 50 GPM AND 60 PSI MINIMUM.
Engineering
Issued 8 June 1987
Resolved
REPAIR JABSCO BILGE PUMP.
Fire Fighting
Issued 8 June 1987
Resolved
REPAIR PORT FIRESTATION NOZZLE SO THAT IT WILL SHUT OFF.
Lifesaving
Issued 8 June 1987
Resolved
REPAIR BROKEN STRAP ON RING BUOY.
Lifesaving
Issued 8 June 1987
Resolved
STENCIL VESSEL NAME AND CAPACITY ON THE BUOYANT APPARATUS (IN LETTERS AND NUMBERS AT LEAST 1 1/2" HIGH).
Casualty record · 3
16 September 2012Routine · role: Involved in a Marine Casualty · activity 4442405
10 June 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4665547
4 July 2013Routine · role: Involved in a Marine Casualty · activity 4655003
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.