MAURY USCG vessel records Sign in
← All vessels

ENTERPRISE

ENTERPRISE is a 1978 passenger vessel (inspected). The Coast Guard has recorded 99 inspections since 1985, most recently in October 2025, along with 170 deficiencies, 5 operational controls and 3 casualty investigations between 2012 and 2013.

Records from 1985 to 2025. Most recent: inspection, 25 October 2025.

Built
1978
Last inspected
25 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYB2848
Flag
UNITED STATES
367095040
Maury page id
psix-49795

Inspections, by type

…with no type recorded6
Years with a record 40 calendar years (1985–2025)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)76.3 ft × 24.7 ft × 5.3 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPEACOCKS BOAT BUILDING CO · WILMINGTON, CA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYB2848MMSI 367095040 · active · compulsorily equipped · granted 5 June 2018, expires 30 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 99

25 October 2025 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8214137
6 May 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075374
28 January 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981997
12 October 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8008054
25 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7867605
12 October 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7804055
26 April 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7634195
14 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650833
14 February 2023 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610142
26 January 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627759
16 December 2022 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610172
8 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606132
24 February 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377152
9 October 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329219
12 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7173529
17 February 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7141187
28 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6962574
27 February 2019 Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610161
22 February 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630768
7 December 2018 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622604
5 June 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6435475
13 April 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384240
27 November 2017 Deficiency Check · Annual Inspection
Physical examination · Navigation Center · Activity 6313556
1 March 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6070489
14 February 2017 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6069649
31 May 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5894964
26 April 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829485
8 September 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5238338
7 September 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5238536
7 May 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4835708
19 July 2012 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4384263
14 February 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4000343
13 February 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4243626
1 February 2012 Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4233247
18 February 2011 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3961545
7 January 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3922843
23 March 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3680557
16 March 2010 DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3696965
12 January 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3636706
11 May 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3470344
14 April 2009 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3452694
6 April 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3448136
5 February 2009 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3413129
23 January 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3126053
9 April 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2903068
12 March 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2870823
4 April 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594063
27 March 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2610488
4 January 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2561571
17 March 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2302823
12 March 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2023363
3 December 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1959535
18 March 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1759591
13 March 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1491690
27 November 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1473832
30 April 2001 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382335
3 April 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397617
30 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387017
28 March 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395407
21 December 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410217
24 March 1999 Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397113
24 March 1998 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388493
15 April 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390498
6 September 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398529
22 April 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1080617
16 April 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392436
23 October 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 872093
25 April 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392212
28 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1468782
10 May 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169455
27 April 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168765
4 May 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149443
2 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149197
5 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 832532
12 May 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267596
25 November 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 943488
25 November 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253579
16 May 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220825
9 April 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1211537
16 July 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 903411
19 June 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928336
23 May 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908773
31 January 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1232471
2 January 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928356
21 December 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1217696
31 August 1989 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039637
22 June 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887420
6 June 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888765
20 January 1989 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205272
18 January 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888494
14 June 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 891724
26 May 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886958
26 May 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1342077
23 July 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022417
14 July 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1017848
8 June 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1028534
9 June 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991153
16 October 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994446
7 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983131

Deficiency record · 170

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2024 Resolved
Exhaust gas leaking from exhaust hose in steering lazarette. Fix exhaust gas leak. 46CFR182.05(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2024
Resolved 12 October 2024
Resolution: re-attached exhaust hose to slide under pedro fitting, tightened hose clamps.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 October 2024 Resolved
Audible alarm sounds in pilot house but no visual for bilge high water
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2024
Resolved 23 October 2024
Resolution: MI witnessed proper illumination of high water alarm in pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2024 Resolved
Each survival craft must be ready for immediate use so that crew members can carry out preparations for embarkation and launching in less than 5 minutes. MI found life float and buoyant apparatus painter and grab lines tangled in a way that impedes immediate use. 180.130(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found three overhead light fixture covers missing in bunk room. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2024 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Life floats and buoyant apparatuses found without spacers in between. 46 CFR 180.137(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 25 March 2024 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions. MI found cracked window on bridge. 46 CFR 177.1020
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet)in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Each floating waterlight on a vessel carrying only one ring buoy, musy be attached to the lanyard with a corrosion resistant clip. MI found ring life buoy with light not secured with a corrosion resistant clip. 46 CFR 180.70(d)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. MI found life jackets with the wrong vessel name. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 February 2023 Resolved
Make ID'd bulkhead penetrations water tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 16 March 2023
Resolution: All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 February 2023 Resolved
MI found fwd and aft flush type hatches inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 14 April 2023
Resolution: Recieved pictures. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 February 2022 Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for life floats and buoyant apparatus must meet the follwing specifications: Lifeline and pendants. The lifeline and pendants must be furnished bu the manufacturer with the approved life float or buoyant apparatus. Replacement lifeline and pendants must meet the requirements in Subpart 160.010 of this chapter. Properly rig life float and buoyant apparatus onboard. 46 CFR 180.175(f)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Operator provided photo of reel dark synthetic "Tytan" lifeline and floats rerigged.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Operator provided photo of flashlights (three) onboard vesel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2022 Resolved
Each battery used in an item of lifesaving equipment except inflatable survival craft equipment must be replaced duringt he annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. 46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Operator provided photo of six 6V batteries dated 03/24.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 April 2021 Resolved
Each vessel constructed of a material other than wood certificated to operate on a coastwise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel is certificated to carry 153 total person. Vessel has on board life saving for 104 total persons. Vessel is restricted to carrying 104 persons until they can satisfactorily provide life floats for 100% of total persons permitted on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2021
Resolved 14 March 2023
Resolution: Deficiency no longer applciable. Vessel has since been certificated with a new COI and different passenger account.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2021 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI discovered the visual indicator for the forward galley compartment high water level alarm to not be operational. Vessel to prove proper operation of the visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 5 May 2021
Resolution: Vessel installed new bilge alarm panel. Vessel provided video of panel operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2021 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI discovered float alarm activation switch to be mounted in such away that it inhibits proper operation. Vessel to mount the switch properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel properly mounted float switch and demonstrated proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 April 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI discovered fan blades to be completely uncovered. Vessel to provide proper guard for fan.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel installed cover for ventilation fan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards. MI discovered outlet in the galley space to have a piece broken off inside the outlet and generally be unsafe. Vessel to replace the unsafe outlet.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel replaced outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI discovered 04 life jackets that did not have an operational clip for proper securing. Vessel to replace the 04 life jackets and is limited to 149 total persons on board until compliance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2021
Resolved 14 March 2023
Resolution: Deficiency no longer applicable. Vessel has since receieved a new COI with a different passenger count.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 April 2021 Resolved
Each life float must be fitted with two paddles; each paddle must be lashed to the life float. MI discovered the paddles for the vessel's 25 person life float to not be lashed to the life float. Vessel to properly lash the paddles to the life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel tethered paddles to lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 April 2021 Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently equipped to allow the crew to recover a helpless person from the water. MI determined that the rescue platform the crew uses to remove a helpless person from the water to be too corroded for safe use. Vessel to provide a satisfactory means to recover an unresponsive person from the water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel made repairs to hinges on their platform. Platform is sound and ready for service.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2020 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC type accepted category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB battery expired JAN2019, vessel is restricted from operating beyond 03 nautical miles from shore until battery is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2020
Resolved 2 June 2020
Resolution: Replaced with new EPIRB and battery set to expire MAY2030.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 February 2019 Resolved
Vessel stern light is found to be inoperable. Prove stern light is operable. Vessel is restricted to day time operations until deficiency is corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 May 2019
Resolution: Vessel provided operable stern light to the satisfaction of the MI.
Fire Fighting › Fire Pumps › Capacity
Issued 5 June 2018 Resolved
properly repair vessel fire pump to provide 50 gallons per minute at a pressure greater than 60 PSI. Vessel is no-sailed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2018
Resolution: Vessel repaired fire pump and is able to provide 50 GPM at a pressure greater that 60 PSI. All sat.
Documentation › Logs/Records › Logbook (official)
Issued 5 June 2018 Resolved
Ensure a written passenger count is available and logged both onshore and on vessel of all passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Verified properly written passenger count. All sat.
Engineering › Lubricating Oil Service System › Pump
Issued 1 March 2017 Resolved
Repair oil leaks on generator and main engine.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Replaced gasket on generator and tightened filter fittings on main engine to eliminated oil leaks.
Lifesaving › Lifebuoys › Stowage
Issued 1 March 2017 Resolved
Mount starboard ring lifebuoy so that it is readily accessible.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Placed ring lifebuoy in easily accessible location during inspection. Permanent mount provided later.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 March 2017 Resolved
Label 17 Adult/1 Child lifejacket with Vsl name so that it is clearly visible. 46CFR185.30-5
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: labeled lifejackets with vessel name.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 March 2017 Resolved
Replace retroreflective tape on 17 adult/1 child life jackets where indicated.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Replaced retro-reflective tape on lifejackets to the satisfaction of the attending Marine Inspector.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 March 2017 Resolved
CLearly mark stowage of lifejackets and post donning placard.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Labeled lifejacket stowage.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 March 2017 Resolved
Replace 1 missing adult lifejacket.
Action required: 705 - Other - as specified
Resolved 1 March 2017
Resolution: Corrected during inspection, no CG-835 issued to owner.
Lifesaving › Lifefloat › Float-free Link
Issued 1 March 2017 Resolved
Connect all Life floats to their weak links.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 March 2017
Resolution: Corrected during inspection.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 February 2017 Resolved
Conduct permanent weld repairs to marine sanitation holding tank, both port & stbd.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 14 March 2017
Resolution: See Narrative.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 14 February 2017 Resolved
Remove all oil in engine room bilge to remove flammable hazards.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 14 March 2017
Resolution: See Narrative.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 April 2016 Resolved
Provide operable masthead light. Vessel is restricted to daylight operations until corrected. Make stern & masthead light visible to correct arc of visibility (135 degrees / 225 degrees).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 26 April 2016 Resolved
Provide new stowage arrangement for waterlights of 03 buoyant apparatuses on top of wheelhouse, so that it does not interfere in launching.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 26 April 2016 Resolved
Provide now weak link with identification tag for the BA on top of wheelhouse.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2016 Resolved
Make all new wiring above wheelhouse secured with metal supports not more than 24" apart.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 April 2016 Resolved
Provide legible emergency instructions posted at the operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 April 2016 Resolved
Log all fire, abandon ship, & MOB drills & make ready for CG review.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 31 May 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 April 2016 Resolved
Test & log EPIRB checks on monthly basis.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 31 May 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 April 2016 Resolved
Prove proper securing of MSD while within 3NM.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 April 2016 Resolved
Provide second hose clamp on exhaust piping in lazarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 April 2016 Resolved
Provide current crew list with all employees for DAPI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 26 April 2016 Resolved
Renew severaly degraded retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Retroreflective material attached.
Lifesaving › Buoyant Apparatus › Marking
Issued 26 April 2016 Resolved
[name withheld] with vessel name and persons capacity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Name of vessel properly marked on BA's.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 April 2016 Resolved
Replace 06 unserviceable Kapok PFDs and provide 03 additional PFDs to fulfill required # per COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: 09 new lifejackets made available.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 April 2016 Resolved
Renew retroreflective material on 23 identified PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: New retroreflective material installed.
Lifesaving › Lifefloat › Paddle
Issued 26 April 2016 Resolved
Provide paddles for new lifefloat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Paddles provided.
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 26 April 2016 Resolved
Arrange survival craft for logical deployment either by crew or automatically upon sinking.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Deployment plan for survival craft arrangement made logical and workable.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2016 Resolved
Renew retroreflective material on ring (01) lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: New retroreflective material attached to ring lifebuoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 8 September 2015 Resolved
Prove proper operation of main engine/start up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 9 September 2015
Resolution: Vessel replaced starter & associated wires with new; MI witness 02 start and secured from bridge control; all appeared satisfactory.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 March 2012 Resolved
Replace expired batteries in lifefloat lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2012
Resolved 5 March 2012
Documentation › Certificates/Documents › Stability Letter
Issued 5 March 2012 Resolved
Provide stability addendum in accordance with AAWPP from MSC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2012
Resolved 27 April 2012
Resolution: See attached email in documents stating no action is required for the a stability addendum
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 March 2012 Resolved
Make forward engine room bulkhead watertight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 March 2012
Resolved 5 March 2012
Resolution: Item was fixed on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 1 February 2012 Resolved
Renew cracked bridge windows.
Due 1 March 2012
Resolved 27 March 2012
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2011 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 20 March 2011
Resolved 24 February 2011
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2011 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 20 March 2011
Resolved 24 February 2011
Electrical › Electric Generation Source (service) › Switch
Issued 23 March 2010 Resolved
Remove or cap dead end wires on genset fuel system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 6 April 2010
Resolution: Wire were no longer needed so wire run was removed.
Electrical › Electrical Distribution System (service) › Conductor
Issued 23 March 2010 Resolved
Secure all loose wires in cable runs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 6 April 2010
Resolution: All cable runs now have hangers and are secure.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 23 March 2010 Resolved
Replace anchor line. Line has areas that are worn through more than half way and is generally in bad condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 6 April 2010
Resolution: Anchor line has been replaced with new 3 inch double braided line.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 23 March 2010 Resolved
Secure loose anchors below decks. Make compartment ready for sea. Two spare anchors stowed below decks were sitting on deck next to missing deck plates. Possibility of anchor falling 2 feet into bilge and puncturing hull.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 6 April 2010
Resolution: One anchor was removed and the other has been secured. This applies only for the anchors below deck, the main anchor is on the bow and ready for use.
Stability › Unintentional Flooding › General
Issued 23 March 2010 Resolved
Cap old keel cooler piping under main engine. If cooler were to rupture, compartment will flood.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 6 April 2010
Resolution: Keel cooler has been capped.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 March 2010 Resolved
Install fan guard on engine room supply fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 6 April 2010
Resolution: Fan cover is now installed and works as it should.
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2009 Resolved
Company policy insufficient as required by 46 CFR part 16.401.
Due 14 May 2009
Resolved 5 May 2009
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2009 Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 14 May 2009
Resolved 5 May 2009
Engineering › Steering Gear System › Ram
Issued 6 April 2009 Resolved
Hydraulic steering ram rod (port side unit) found leaking while at full rudder during steering gear test. Vessel required to repair or replace hydraulic steering ram, to the satisfaction of an attending CG marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 11 May 2009
Resolution: Ram replaced, operation sat.
Construction/Loadline › Hull › Transverse Frame
Issued 6 April 2009 Resolved
Crop and renew watertight bulkhead supports, ladder, and bilge athwartships support IAW 46CFR176.802, using NVIC 7-68 as a guide, in the vessel's forepeak.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: Repairs conducted as directed.
Construction/Loadline › Hull › Transverse Frame
Issued 6 April 2009 Resolved
Crop and renew corroded athwartships frames as indicated in vessel's lazarette IAW 46CFR176.802, using NVIC 7-68 as a guide.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: Repairs conducted as directed.
Lifesaving › Lifefloat › Paddle
Issued 6 April 2009 Resolved
Replace 02 paddles in vessel's life float arrangement IAW 46CFR180.175(d).
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 8 April 2009
Resolution: 02 new paddles provided.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 April 2009 Resolved
Install main engine exhaust lagging to cooling water injection IAW46CFR182.425(b)(2).
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: Lagging installed
Communications › Radio Communications › EPIRB
Issued 6 April 2009 Resolved
Replace expired EPIRB battery IAW 46CFR180.64.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 9 April 2009
Resolution: EPIRB battery replaced.
Stability › Watertight Integrity › General
Issued 6 April 2009 Resolved
Address water ingress from rudder post IAW 46CFR176.814.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: No leakage noted while operating ship''s rudder.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 April 2009 Resolved
Mark vessel's name in clearly legible letters on all ring life buoys IAW 46CFR185.604(b).
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 8 April 2009
Resolution: All ring life buoys properly stenciled.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 March 2007 Resolved
Replace outlet cover under bridge helm console.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Cover replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 March 2007 Resolved
Install proper stuffing tube for cable going into fuse box on bridge.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Stuffing tube installed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 12 March 2007 Resolved
Crop and renew ladder support to fwd peak to good metal
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Repair approved.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 March 2007 Resolved
Replace globe for light fixture in sewage compartment.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Globe replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 March 2007 Resolved
Provide wire supports (metallic) every 24" for cable in sewage compartment.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Supports provided.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 12 March 2007 Resolved
Properly mount sewage pump.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Mounted properly.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 March 2007 Resolved
Provide cover for outlet box on mess deck.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Cover provided.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 March 2007 Resolved
Provide enclosure for electrical cable splice in engineroom portside aft.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Wire replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 March 2007 Resolved
Replace spliced cable for battery charger in engineroom
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Cable replaced.
Engineering › Fuel Oil Service System › Filter
Issued 12 March 2007 Resolved
Remove fuel oil from fuel filter bowl in engineroom.
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 12 March 2007
Resolution: Vsl removed fuel oil.
Documentation › Logs/Records › Drug Test Records
Issued 12 March 2007 Resolved
Provide proof of 1 hour EAP supervisor training.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Training certificate provided.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 12 March 2007 Resolved
Provide rescue boat/platform to allow crew to recover helpless person in water.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 9 April 2007
Resolution: Platform installed on rescue ladder.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 27 March 2006 Resolved
Repair damage to twin disk gear box. Vessel suffered minor engine failure when gasket in gear box was damaged.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 29 March 2006
Resolution: All repairs were made and engine was tested.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 January 2006 Resolved
Clean, treat rust in lazarette.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 12 March 2007
Resolution: Vsl treated rust in laz.
Navigation › Electronic Positioning
Issued 12 March 2004 Resolved
Expired EPIRB battery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2004
Resolution: New battery provided
Documentation › Certificates/Documents
Issued 12 March 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 17 April 2004
Resolved 17 March 2004
Resolution: Recieved Fax of License
Electrical › Electrical Distribution System (service)
Issued 13 March 2002 Resolved
Provide cover for open fuse box and distribution panel above bunk in pilot house. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 13 April 2002
Resolved 17 April 2002
Resolution: Satisfactorily installed metallic covering.
Electrical
Issued 13 March 2002 Resolved
Provide single-line diagram of electrical system throughout vessel. Vessel seemed to have inadequate/missing circuit protection for bridge equipment. Additionally, ship's captain (Andrew) stated that they had been making several changes to the electrical system over time.
Due 13 April 2002
Resolved 21 March 2002
Electrical › Electric Generation Source (service)
Issued 13 March 2002 Resolved
Provide cover for generator set electrical box connections. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 13 April 2002
Resolved 17 April 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 13 March 2002 Resolved
Provide adequate flame shields for fuel shutoff reach rods per 46 CFR 182.455(b)(4). LEGACY COMPONENT DESC: Fuel Shutoff Valves
Due 13 April 2002
Resolved 17 April 2002
Engineering › Pressure Vessel
Issued 13 March 2002 Resolved
Provide proof that air compressor meets ASME "U" or "UM" standards; Vessel's data placard did not show any ASME certification. If it does not, it will need to be replaced with an ASME "U" or "UM" approved cylinder. LEGACY COMPONENT DESC: Marking and Stamping
Due 13 April 2002
Resolved 21 March 2002
Resolution: Purchased a one (01) cubic foot "UM" certified air tank.
Lifesaving › Buoyant Apparatus
Issued 13 March 2002 Resolved
Place spacers between buoyant apparatus and lifefloats.
Due 13 April 2002
Resolved 17 April 2002
Lifesaving › Buoyant Apparatus
Issued 13 March 2002 Resolved
Two BA's were not stowed in a float-free arrangement; They were stowed underneath a metal frame for the RADAR and radio. This was corrected during the course of the inspection.
Action required: 705 - Other - as specified
Resolved 13 March 2002
Resolution: This was corrected during the course of the inspection.
Lifesaving
Issued 13 March 2002 Resolved
Provide proof of current NOAA registration for EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 13 April 2002
Resolved 14 March 2002
Resolution: Owner faxed over current NOAA Registration for EPIRB.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 December 2001 Resolved
Replaced sewage holding tank overboard discharge valve.
Due 26 December 2001
Resolved 26 December 2001
Resolution: New valve
Construction/Loadline
Issued 24 March 1999 Resolved
Install and prove proper operation of bilge high level alarms IAW 46 CFR 182.530.
Condition: Unknown
Due 24 May 1999
Resolved 12 May 1999
Electrical
Issued 16 April 1996 Resolved
Replace all wire splices with approved wire connectors. Remove all wiring that is not in use.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Navigation
Issued 25 April 1995 Resolved
PROVIDE UPDATED LIGHT LIST AND COAST PILOT.
Condition: Unknown
Due 28 April 1995
Resolved 26 April 1995
Electrical
Issued 27 April 1994 Resolved
REPLACE BULBS IN STERN, PORT AND FWD MAST LIGHTS WITH PROPER MARINE BULBS.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 27 April 1994 Resolved
PROVIDE 29 ADDITIONAL ADULT LIFEJACKETS.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Electrical
Issued 27 April 1994 Resolved
REWIRE AFT DECK LIGHTS.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 27 April 1994 Resolved
REMOVE OIL FROM BILGES.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 4 May 1993 Resolved
PROVIDE A MEANS OF PERMANENTLY SECURING THE LADDER INTO THE NO.3 BELOW DECKCOMPARTMENT.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Construction/Loadline
Issued 4 May 1993 Resolved
PROVE PROPER OPERATION OF THE ELECTRICAL AUXILIARY BILGE PUMP.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Engineering
Issued 4 May 1993 Resolved
RENEW THE FLAME SCREEN ON THE STARBOARD DIESEL FUEL TANK VENT.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Documentation
Issued 5 January 1993 Resolved
INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 45 CFR 185.30-3 PRIOR TO COMPLETION OF THE FIRST ROUTINE DRYDOCKING AFTER 01 JANUARY 1993.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Accommodation/Occupational Safety
Issued 12 May 1992 Resolved
REMOVE EXCESS GREASE BUILD-UP FROM GALLEY GRILL.
Condition: Unknown
Due 31 May 1992
Resolved 20 May 1992
Lifesaving
Issued 12 May 1992 Resolved
POST SIGN PROHIBITING PASSENGER ACCESS TO UPPER DECK._x001C_
Condition: Unknown
Due 31 May 1992
Resolved 20 May 1992
Accommodation/Occupational Safety
Issued 12 May 1992 Resolved
PROVIDE A TOTAL OF TWO (2) WASH BASINS FOR PASSENGERS.
Condition: Unknown
Due 31 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 9 April 1991 Resolved
IN THE FOREPEAK: REPLACE UNDERDECK TRANSVERSE FRAMES AND LONGITUDINALS IN THE AREA OF HATCH OPENING AS MARKED IN CHALK.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Construction/Loadline
Issued 9 April 1991 Resolved
RENEW PIPING FOR BAIT SUCTION AFTER THE SEA VALVE TO THE 90 DEGREE ELBOW INTHE HOLDING TANK COMPARTMENT.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Electrical
Issued 9 April 1991 Resolved
REPLACE LAGGING ON GENERATOR EXHAUST.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Construction/Loadline
Issued 9 April 1991 Resolved
RESTENCIL MAXIMUM DRAFT MARKS ON BOTH PORT AND STBD QUARTER IN A CONSTRASTING COLOR FROM THAT OF THE HULL.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Engineering
Issued 9 April 1991 Resolved
RELOCATE REACH ROD FOR PORT SIDE EMERGENCY FUEL SHUT-OFF TO INBOARD SIDE OFBILGE PUMP PIPING.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Accommodation/Occupational Safety
Issued 9 April 1991 Resolved
RE-ATTACH TOP OF LADDER TO THE TOP OF THE MID-BODY COMPARTMENT UNDER THE GALLEY.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Electrical
Issued 9 April 1991 Resolved
REPAIR OR REMOVE ABANDONED OVERHEAD LIGHTING IN THE MID-BODY COMPARTMENT UNDER GALLEY.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Navigation
Issued 9 April 1991 Resolved
REPLACE PIN FROM STEERING GEAR RAM TO RUDDER YOKE ON STBD SIDE OF STEERING GEAR.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Engineering
Issued 19 June 1990 Resolved
REPLACE PVC PIPING IN BILGE DISCHARGE SYSTEM WITH METALLIC PIPING AS PER 46 CFR 182.40-5(B).
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Fire Fighting
Issued 19 June 1990 Resolved
REPLACE FIRE HOSE WITH UL APPROVED RUBBER LINED FIRE HOSE AS PER 46 CFR 181.15-10(D).
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Lifesaving
Issued 23 May 1990 Resolved
PROVIDE AN ADDITIONAL 27 ADULT LIFE PRESERVERS PRIOR TO ENGAGING IN WHALE WATCHING.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Electrical
Issued 23 May 1990 Resolved
REMOVE OR PROPERLY DEAD-END UNUSED WIRES UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Fire Fighting
Issued 23 May 1990 Resolved
REPAIR BROKEN GLASS ON FIREMAIN PRESSURE GAUGE.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Construction/Loadline
Issued 23 May 1990 Resolved
PROVIDE WATERTIGHT CLOSURES FOR EMERGENCY STEERING ACCESS AND PORT & STBD EMERGENCY FUEL CUT-OUT VALVE ACCESS.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Lifesaving
Issued 23 May 1990 Resolved
PROVIDE 25 ADULT LIFE PRESERVERS. TOTAL PERSONS ON BOARD SHALL BE LIMITED TO 74 UNTIL COMPLETION OF THIS ITEM
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Engineering
Issued 23 May 1990 Resolved
PROVE PROPER OPERATION OF THE MECHANICAL BILGE PUMP POWERED BY THE MAIN ENGINE.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Engineering
Issued 23 May 1990 Resolved
PROVE PROPER OPERATION OF THE MAIN ENGINE LUBE OIL PRESSURE GAUGE IN THE PILOT HOUSE.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Electrical
Issued 23 May 1990 Resolved
PROVIDE GLOBES FOR LIGHTS IN BOTH HEADS AND OVER LADDER TO THE CREW COMPARTMENT.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Construction/Loadline
Issued 23 May 1990 Resolved
IN THE CREW COMPARTMENT - REPAIR/REPLACE BROKEN PORTLIGHT GLASS (PORT SIDE,AFT), REPAIR/REPLACE BROKEN PORTLIGHT DOG (STBD SIDE, AFT), AND PROVE PROPER OPERATION OF ALL PORTLIGHT DOGS.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Accommodation/Occupational Safety
Issued 23 May 1990 Resolved
PROVIDE CUT-OUT VALVES IN WATER SUPPLY TO EACH TOILET.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Accommodation/Occupational Safety
Issued 23 May 1990 Resolved
PROVE ADEQUATE WATER PRESSURE TO EACH WASH BASIN IN THE HEADS.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Navigation
Issued 23 May 1990 Resolved
PROPERLY SUPPORT HYDRAULIC HOSE AT THE STEERING GEAR.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Accommodation/Occupational Safety
Issued 23 May 1990 Resolved
PROPERLY SUPPORT TRANSVERSE DECK PLATE IN FRONT OF ENGINE ROOM BATTERY BOX.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Accommodation/Occupational Safety
Issued 23 May 1990 Resolved
REMOVE OR PROPERLY MOUNT GALLEY CROCK POT AND CHIP RACK.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Electrical
Issued 23 May 1990 Resolved
PROVIDE PROPER METALLIC SUPPORTS FOR ELECTRIC CABLES UNDER BRIDGE CONSOLE, ON BRIDGE, ON GALLEY DECK, IN ENGINE ROOM, AND IN FWD COMPARTMENT.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Electrical
Issued 21 December 1989 Resolved
REPAIR OPEN LIGHT SOCKET IN LAZARETTE AND INSTALL A PROPER COVER.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Construction/Loadline
Issued 21 December 1989 Resolved
PROPERLY REPAIR STARBOARD AFT CORNER SECTION OF MAIN DECK RAILING.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Construction/Loadline
Issued 21 December 1989 Resolved
PROPERLY WATERPROOF THREE HOLES AND ONE STUFFING TUBE IN AFT BULKHEAD OF FORWARD STORAGE AREA (NEAR BATTERY CHARGER).
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Construction/Loadline
Issued 21 December 1989 Resolved
REMOVE WATER AND DEBRIS FROM BILGES IN THE FOREPEAK AND THE LAZARETTE.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Electrical
Issued 21 December 1989 Resolved
PROPERLY DRIP-PROOF THE TWO BATTERY CHARGERS (IN ENGINEROOM AND FORWARD STORAGE AREA).
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Engineering
Issued 21 December 1989 Resolved
INSTALL PROPER FLAME DIFFUSERS ON THE FUEL OIL FILTERS FOR THE MAIN ENGINE.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Engineering
Issued 21 December 1989 Resolved
PROPERLY LABEL BILGE SUCTION VALVES AT THE BILGE MANIFOLD.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Engineering
Issued 21 December 1989 Resolved
INSTALL PLUGS IN DRAIN VALVES FOR THE PORT AND STARBOARD FUEL OIL TANKS ANDIN THE DRAIN VALVE FOR THE AFT LUBE OIL TANK.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Documentation
Issued 6 June 1989 Resolved
PROVIDE VALID STABILITY LETTER.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989 Resolved
MAKE UP PENDANTS OF PROPER LENGTH AND ATTACH RETROREFLECTIVE TAPE TO B/A'S.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Navigation
Issued 6 June 1989 Resolved
PERMANENTLY BOLT AIR COMPRESSOR IN SECOND COMPARTMENT.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 6 June 1989 Resolved
LABEL FUEL SHUT-OFF VALVES WITH ARROW INDICATING DIRECTION TO CLOSE.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Fire Fighting
Issued 6 June 1989 Resolved
PROVIDE HAND FIRE PUMP AND PROVE PROPER OPERATION.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Construction/Loadline
Issued 6 June 1989 Resolved
MAKE ENGINEROOM HATCH, PORT SIDE, WEATHERTIGHT.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Electrical
Issued 26 May 1988 Resolved
PROVIDE COVERS FOR 2 MOTOR CONTROLLERS IN THE ENGINEROOM.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Electrical
Issued 26 May 1988 Resolved
REPAIR KICK PIPE FOR THE ELECTRICAL WIRE AT VSL MAST.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Lifesaving
Issued 26 May 1988 Resolved
REPAIR GRAB LINE ON THE LIGHTED RING BUOY.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Lifesaving
Issued 26 May 1988 Resolved
PROVIDE A WATERTIGHT CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Lifesaving
Issued 26 May 1988 Resolved
PROVIDE 3 WATER LIGHTS FOR THE VESSELS BUOYANT APPATATUS AND RING BUOY.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Lifesaving
Issued 26 May 1988 Resolved
PROVIDE PROPER PENDANT LINES FOR ALL 4 OF THE VESSEL'S BUOYANT APPARATUS.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Lifesaving
Issued 26 May 1988 Resolved
PROPERLY AND PERMANENTLY FIX THE VESSEL'S NAME TO THE BUOYANT APPARATUS.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Documentation
Issued 26 May 1988 Resolved
PROVIDE PROOF OF PROPER VESSEL DOCUMENTATION.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Engineering
Issued 26 May 1988 Resolved
LABEL EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Fire Fighting
Issued 26 May 1988 Resolved
PROVIDE A 1.5" FIRE NOZZLE FOR #2 FIRE HOSE.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Accommodation/Occupational Safety
Issued 26 May 1988 Resolved
REPLACE LEAKING ENGINEROOM BILGE SUCTION PIPING.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 8 June 1987 Resolved
DRYDOCK THE VESSEL FOR COAST GUARD EXAMINATION.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Lifesaving
Issued 8 June 1987 Resolved
REPAIR SNAPS ON 5 ADULT LIFE JACKETS.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Fire Fighting
Issued 8 June 1987 Resolved
REPAIR FIREPUMP SO THAT IT WILL PROVIDE A 50 GPM AND 60 PSI MINIMUM.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Engineering
Issued 8 June 1987 Resolved
REPAIR JABSCO BILGE PUMP.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Fire Fighting
Issued 8 June 1987 Resolved
REPAIR PORT FIRESTATION NOZZLE SO THAT IT WILL SHUT OFF.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Lifesaving
Issued 8 June 1987 Resolved
REPAIR BROKEN STRAP ON RING BUOY.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Lifesaving
Issued 8 June 1987 Resolved
STENCIL VESSEL NAME AND CAPACITY ON THE BUOYANT APPARATUS (IN LETTERS AND NUMBERS AT LEAST 1 1/2" HIGH).
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987

Casualty record · 3

16 September 2012Routine · role: Involved in a Marine Casualty · activity 4442405
10 June 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4665547
4 July 2013Routine · role: Involved in a Marine Casualty · activity 4655003
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record