Records from 2012 to 2025. Most recent: inspection, 25 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 27
25 October 2025
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8214137
6 May 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075374
28 January 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981997
12 October 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8008054
25 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7867605
12 October 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7804055
26 April 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7634195
14 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650833
14 February 2023
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610142
26 January 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627759
16 December 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610172
8 December 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606132
24 February 2022
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377152
9 October 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329219
12 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7173529
17 February 2021
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7141187
28 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6962574
27 February 2019
Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610161
22 February 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630768
7 December 2018
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622604
5 June 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6435475
13 April 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384240
27 November 2017
Deficiency Check · Annual Inspection
Physical examination · Navigation Center · Activity 6313556
1 March 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6070489
14 February 2017
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6069649
31 May 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5894964
26 April 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829485
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2024
Resolved
Exhaust gas leaking from exhaust hose in steering lazarette. Fix exhaust gas leak. 46CFR182.05(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2024
Resolved 12 October 2024
Resolution: re-attached exhaust hose to slide under pedro fitting, tightened hose clamps.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 October 2024
Resolved
Audible alarm sounds in pilot house but no visual for bilge high water
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2024
Resolved 23 October 2024
Resolution: MI witnessed proper illumination of high water alarm in pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2024
Resolved
Each survival craft must be ready for immediate use so that crew members can carry out preparations for embarkation and launching in less than 5 minutes. MI found life float and buoyant apparatus painter and grab lines tangled in a way that impedes immediate use.
180.130(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found three overhead light fixture covers missing in bunk room.
46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2024
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high.
When stowed in tiers, the separate units must be kept apart by spacers. Life floats and buoyant apparatuses found without spacers in between.
46 CFR 180.137(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 25 March 2024
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding
the maximum load from wave and wind conditions. MI found
cracked window on bridge.
46 CFR 177.1020
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet)in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Each floating waterlight on a vessel carrying only one ring buoy, musy be attached to the lanyard with a corrosion resistant clip. MI found ring life buoy with light not secured with a corrosion resistant clip.
46 CFR 180.70(d)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. MI found life jackets with the wrong vessel name.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 16 April 2024
Resolution: Attended vessel for DFU. Corrected to the Satisfaction of attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 February 2023
Resolved
Make ID'd bulkhead penetrations water tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 16 March 2023
Resolution: All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 February 2023
Resolved
MI found fwd and aft flush type hatches inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 14 April 2023
Resolution: Recieved pictures. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 February 2022
Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for life floats and buoyant apparatus must meet the follwing specifications: Lifeline and pendants. The lifeline and pendants must be furnished bu the manufacturer with the approved life float or buoyant apparatus. Replacement lifeline and pendants must meet the requirements in Subpart 160.010 of this chapter. Properly rig life float and buoyant apparatus onboard.
46 CFR 180.175(f)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Operator provided photo of reel dark synthetic "Tytan" lifeline and floats rerigged.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Operator provided photo of flashlights (three) onboard vesel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2022
Resolved
Each battery used in an item of lifesaving equipment except inflatable survival craft equipment must be replaced duringt he annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number.
46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
Resolution: Operator provided photo of six 6V batteries dated 03/24.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 April 2021
Resolved
Each vessel constructed of a material other than wood certificated to operate on a coastwise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel is certificated to carry 153 total person. Vessel has on board life saving for 104 total persons. Vessel is restricted to carrying 104 persons until they can satisfactorily provide life floats for 100% of total persons permitted on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2021
Resolved 14 March 2023
Resolution: Deficiency no longer applciable. Vessel has since been certificated with a new COI and different passenger account.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI discovered the visual indicator for the forward galley compartment high water level alarm to not be operational. Vessel to prove proper operation of the visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 5 May 2021
Resolution: Vessel installed new bilge alarm panel. Vessel provided video of panel operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI discovered float alarm activation switch to be mounted in such away that it inhibits proper operation. Vessel to mount the switch properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel properly mounted float switch and demonstrated proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 April 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI discovered fan blades to be completely uncovered. Vessel to provide proper guard for fan.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel installed cover for ventilation fan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards. MI discovered outlet in the galley space to have a piece broken off inside the outlet and generally be unsafe. Vessel to replace the unsafe outlet.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel replaced outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI discovered 04 life jackets that did not have an operational clip for proper securing. Vessel to replace the 04 life jackets and is limited to 149 total persons on board until compliance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2021
Resolved 14 March 2023
Resolution: Deficiency no longer applicable. Vessel has since receieved a new COI with a different passenger count.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 April 2021
Resolved
Each life float must be fitted with two paddles; each paddle must be lashed to the life float. MI discovered the paddles for the vessel's 25 person life float to not be lashed to the life float. Vessel to properly lash the paddles to the life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel tethered paddles to lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 April 2021
Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently equipped to allow the crew to recover a helpless person from the water. MI determined that the rescue platform the crew uses to remove a helpless person from the water to be too corroded for safe use. Vessel to provide a satisfactory means to recover an unresponsive person from the water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 16 April 2021
Resolution: Vessel made repairs to hinges on their platform. Platform is sound and ready for service.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2020
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC type accepted category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB battery expired JAN2019, vessel is restricted from operating beyond 03 nautical miles from shore until battery is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2020
Resolved 2 June 2020
Resolution: Replaced with new EPIRB and battery set to expire MAY2030.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 February 2019
Resolved
Vessel stern light is found to be inoperable. Prove stern light is operable. Vessel is restricted to day time operations until deficiency is corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 May 2019
Resolution: Vessel provided operable stern light to the satisfaction of the MI.
Fire Fighting › Fire Pumps › Capacity
Issued 5 June 2018
Resolved
properly repair vessel fire pump to provide 50 gallons per minute at a pressure greater than 60 PSI. Vessel is no-sailed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2018
Resolution: Vessel repaired fire pump and is able to provide 50 GPM at a pressure greater that 60 PSI. All sat.
Documentation › Logs/Records › Logbook (official)
Issued 5 June 2018
Resolved
Ensure a written passenger count is available and logged both onshore and on vessel of all passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 7 June 2018
Resolution: Verified properly written passenger count. All sat.
Engineering › Lubricating Oil Service System › Pump
Issued 1 March 2017
Resolved
Repair oil leaks on generator and main engine.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Replaced gasket on generator and tightened filter fittings on main engine to eliminated oil leaks.
Lifesaving › Lifebuoys › Stowage
Issued 1 March 2017
Resolved
Mount starboard ring lifebuoy so that it is readily accessible.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Placed ring lifebuoy in easily accessible location during inspection. Permanent mount provided later.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 March 2017
Resolved
Label 17 Adult/1 Child lifejacket with Vsl name so that it is clearly visible.
46CFR185.30-5
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: labeled lifejackets with vessel name.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 March 2017
Resolved
Replace retroreflective tape on 17 adult/1 child life jackets where indicated.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Replaced retro-reflective tape on lifejackets to the satisfaction of the attending Marine Inspector.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 March 2017
Resolved
CLearly mark stowage of lifejackets and post donning placard.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 14 March 2017
Resolution: Labeled lifejacket stowage.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 March 2017
Resolved
Replace 1 missing adult lifejacket.
Action required: 705 - Other - as specified
Resolved 1 March 2017
Resolution: Corrected during inspection, no CG-835 issued to owner.
Lifesaving › Lifefloat › Float-free Link
Issued 1 March 2017
Resolved
Connect all Life floats to their weak links.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 March 2017
Resolution: Corrected during inspection.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 February 2017
Resolved
Conduct permanent weld repairs to marine sanitation holding tank, both port & stbd.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 14 March 2017
Resolution: See Narrative.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 14 February 2017
Resolved
Remove all oil in engine room bilge to remove flammable hazards.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 14 March 2017
Resolution: See Narrative.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 April 2016
Resolved
Provide operable masthead light. Vessel is restricted to daylight operations until corrected. Make stern & masthead light visible to correct arc of visibility (135 degrees / 225 degrees).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 26 April 2016
Resolved
Provide new stowage arrangement for waterlights of 03 buoyant apparatuses on top of wheelhouse, so that it does not interfere in launching.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 26 April 2016
Resolved
Provide now weak link with identification tag for the BA on top of wheelhouse.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2016
Resolved
Make all new wiring above wheelhouse secured with metal supports not more than 24" apart.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 April 2016
Resolved
Provide legible emergency instructions posted at the operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 April 2016
Resolved
Log all fire, abandon ship, & MOB drills & make ready for CG review.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 31 May 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 April 2016
Resolved
Test & log EPIRB checks on monthly basis.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 31 May 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 April 2016
Resolved
Prove proper securing of MSD while within 3NM.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 April 2016
Resolved
Provide second hose clamp on exhaust piping in lazarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 April 2016
Resolved
Provide current crew list with all employees for DAPI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 May 2016
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 26 April 2016
Resolved
Renew severaly degraded retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Retroreflective material attached.
Lifesaving › Buoyant Apparatus › Marking
Issued 26 April 2016
Resolved
[name withheld] with vessel name and persons capacity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Name of vessel properly marked on BA's.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 April 2016
Resolved
Replace 06 unserviceable Kapok PFDs and provide 03 additional PFDs to fulfill required # per COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: 09 new lifejackets made available.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 April 2016
Resolved
Renew retroreflective material on 23 identified PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: New retroreflective material installed.
Lifesaving › Lifefloat › Paddle
Issued 26 April 2016
Resolved
Provide paddles for new lifefloat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Paddles provided.
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 26 April 2016
Resolved
Arrange survival craft for logical deployment either by crew or automatically upon sinking.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Deployment plan for survival craft arrangement made logical and workable.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2016
Resolved
Renew retroreflective material on ring (01) lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: New retroreflective material attached to ring lifebuoy.