MAURY USCG vessel records Sign in
← All vessels

BIG STONE LEADER

BIG STONE LEADER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1981, most recently in August 2026, along with 24 deficiencies.

Records from 1981 to 2026. Most recent: inspection, 19 August 2026.

Built
1978
Last inspected
19 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3624
Flag
UNITED STATES
366665740
Maury page id
psix-49800

Inspections, by type

…with no type recorded14
Years with a record 39 calendar years (1981–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)106.4 ft × 21.5 ft × 4.4 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)106.4 ft × 21.5 ft × 4.4 ft
ITC tonnagegross 127 / net 38
BuilderCAMCRAFT, INC. · JEAN LAFITTE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW CASTLE, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
127 - Convention (Subpart B), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
38 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3624MMSI 366665740 · active · compulsorily equipped · granted 26 June 2018, expires 26 June 2028
WSL5754MMSI 366665740 · cancelled · compulsorily equipped · granted 24 January 2015, cancelled 19 June 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 78

19 August 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8468300
18 March 2026 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8302102
10 October 2025 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8247110
8 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8205356
16 August 2024 Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7986659
2 May 2024 Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7905484
11 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7893292
22 May 2023 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7690624
7 December 2022 In-Service Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7609026
25 October 2022 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7583335
1 September 2022 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7547988
28 April 2022 Internal Structural Exam · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7690904
26 August 2021 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7295969
1 August 2020 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7046490
26 June 2020 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6987405
1 May 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6946647
23 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6894976
23 August 2019 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6790272
25 June 2019 Excursion Permit
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6725459
28 August 2018 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6525330
27 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6492603
16 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6481598
5 July 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6467135
5 July 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6483272
30 May 2018 Internal Structural Exam · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6421823
8 March 2016 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5864551
19 May 2014 Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4862209
4 May 2009 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3465058
24 July 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3277819
10 December 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3112735
23 April 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2913445
6 June 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867278
2 December 2005 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2900282
7 April 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2327917
3 September 2004 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2185582
22 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2106632
1 April 2004 COI Inspection · Administrative Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2033190
22 October 2003 Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1933958
2 October 2002 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1682266
25 January 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1481267
26 October 2001 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1379627
25 October 1999 COI Inspection · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462084
17 May 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402900
12 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388753
24 January 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445305
20 January 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1451254
5 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 37532
28 June 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 39193
16 January 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1418077
20 November 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 55429
18 January 1996 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1400273
23 January 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869871
3 January 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468335
16 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166553
4 January 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420821
6 January 1993 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1137169
2 July 1992 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362637
24 March 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359382
20 December 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 943872
4 January 1991 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 920883
7 July 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906188
6 February 1990 COI Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1215324
2 May 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1340387
8 February 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1341120
7 February 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1031097
12 February 1988 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1027889
16 May 1987 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331617
19 August 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989916
22 May 1986 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1295120
7 May 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 987654
27 July 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280524
5 August 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277022
5 August 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281176
13 May 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1276750
12 August 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963769
6 August 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965925
9 October 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 964364
6 August 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967781

Deficiency record · 24

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 September 2022 Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of at least 100% of the total persons permitted on board. Vessel has total inflatable life raft capacity of 48 persons. Maximum persons onboard reduced from 49 to 48 until liferaft capacity is increased. 46 CFR 180.202
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 6 September 2022
Resolution: O/O requested Max persons onboard be reduced from 49 to 48. COI Amended to reflect decrease in max persons.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 July 2018 Resolved
Every vessel 65' or more in length must be fitted with a public address system that is audibile during normal operations thoughout accommodation spaces.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2018
Resolved 13 July 2018
Resolution: Verified PA system is audible from aft deck, in galley, passenger seating and crew accommodation below deck.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 July 2018 Resolved
Vessel must comply with EPA VGP (Vessel General Permit) requirements as mandated by the EPA.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2018
Resolved 13 July 2018
Resolution: Verified vessel has completed PARI form and started logging inspections IAW VGP.
Lifesaving › Lifefloat › Lifeline
Issued 23 April 2007 Resolved
Replace all deteriated lines including the weaklink tether and floating light line for both lifefloats.
Due 7 May 2007
Resolved 24 April 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 23 April 2007 Resolved
Replace deteriorating retro tape on both lifefloats.
Due 7 May 2007
Resolved 24 April 2007
Construction/Loadline › Hull › Weld
Issued 1 April 2004 Resolved
Make repairs to 3 fractured welds in forepeak as makred. ! fracture on port side and 2 on stbd side. Drill stop fracture in stbd side that has propagated into vertical side frame.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 12 April 2004
Resolution: All Fractures repaired.
Construction/Loadline › Structures › Door
Issued 1 April 2004 Resolved
Repair fracture on bottom hinge of aft cabin door.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 12 April 2004
Resolution: Hinge repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 April 2004 Resolved
Vessel operated 66 days outside of 90 day window to have annual inspection completed. Vessel to undergo COI exam prior to leaving port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2004
Resolution: Vessel completed COI exam.
Construction/Loadline › Structures › Deck Plating
Issued 24 October 2003 Resolved
Provide inspection access to under deck in aft compartment.
Action required: 705 - Other - as specified
Due 24 January 2004
Resolved 1 April 2004
Resolution: Item cleared by GALMS 01APR04.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 October 2003 Resolved
Repair or replace center propeller due to crack on leading edge of propeller blade at hub.
Due 24 October 2003
Resolved 24 October 2003
Resolution: Corrected on the spot.
Engineering › Steering Gear System › Rudder
Issued 24 October 2003 Resolved
Replace missing cotter pin on stbd rudder tie rod connection.
Due 24 October 2003
Resolved 24 October 2003
Resolution: Corrected on the spot.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 24 October 2003 Resolved
Replace port MDE salt water suction valve.
Due 24 October 2003
Resolved 24 October 2003
Resolution: Corrected on the spot.
Engineering › Fuel Oil Service System
Issued 24 October 2003 Resolved
Repair diesel fuel line leak on stbd MDE.
Due 24 October 2003
Resolved 24 October 2003
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 24 October 2003 Resolved
Replace laundry dryer vent and clean residual lent.
Due 24 November 2003
Resolved 1 April 2004
Resolution: Item cleared by GALMS 01APR04.
Construction/Loadline › Hull › Weld
Issued 24 October 2003 Resolved
Gouge and weld the following cracked frames: #2 port web 6 frames from centerline, #3 port web 6 frames from centerline, #1 port in two locations 6 frames from centerline, center stanchion at crossbar, #2 center stanchion at crossbar, #4 port web 2 frames from centerline.
Due 24 October 2003
Resolved 24 October 2003
Resolution: Corrected on the spot.
Construction/Loadline
Issued 3 January 1995 Resolved
REMOVE AND REPLACE INCORRECT BOLTS IN TONNAGE OPENING WITH "J" BOLTS.
Condition: Unknown
Due 17 January 1995
Resolved 23 January 1995
Construction/Loadline
Issued 3 January 1995 Resolved
REMOVE CAULKING FROM AROUND TONNAGE OPENING.
Condition: Unknown
Due 17 January 1995
Resolved 23 January 1995
Electrical
Issued 3 January 1995 Resolved
PROVIDE NON-CONDUCTIVE HAND HOLD ON MAIN SWITCHBOARD.
Condition: Unknown
Due 17 January 1995
Resolved 23 January 1995
Lifesaving
Issued 20 December 1991 Resolved
PROVIDE ONBOARD A SUITABLE RESCUE DEVICE.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Navigation
Issued 7 February 1989 Resolved
INSTALL COTTER KEYS IN STEERING SYSTEM ATTACHMENT PINS.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Fire Fighting
Issued 7 February 1989 Resolved
PERFORM ANNUAL SERVICING OF PORTABLE FIRE EXTINGUISHING DEVICES AND FORWARDA COPY OF SERVICE REPORT TO CORPUS CHRISTI OCMI.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Engineering
Issued 7 February 1989 Resolved
PROVE PROPER OPERATION OF PORT SHIP SERVICE GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Engineering
Issued 27 July 1984 Resolved
PROVIDE GUARDS OVER SHAFT COUPLINGS ON PORT AND CENTER ENGINES.
Condition: Unknown
Due 27 July 1984
Resolved 27 July 1984
Construction/Loadline
Issued 27 July 1984 Resolved
REPAIR GUARD RAIL CHAINS AS NEEDED ON AFT DECK. UNTIL SUCH TIME AS THIS IS DONE, NO PASSENGERS ARE TO BE ALLOWED ON AFT DECK WHILE VESSEL IS UNDERWAY.
Condition: Unknown
Due 27 July 1984
Resolved 27 July 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.