MEGAN T. MILLER

MEGAN T. MILLER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1981, most recently in November 2025, along with 109 deficiencies and 2 casualty investigations between 2011 and 2012.

Records from 1981 to 2025. Most recent: inspection, 20 November 2025.

Built
1978
Last inspected
20 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW9003
Flag
UNITED STATES
367141930
Maury page id
psix-49802

Inspections, by type

…with no type recorded12
Years with a record 43 calendar years (1981–2025)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)83.5 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW9003MMSI 367141930 · active · compulsorily equipped · granted 7 September 2016, expires 8 October 2026
WCV5654MMSI not assigned · cancelled · compulsorily equipped · granted 29 November 1995, cancelled 6 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JOSEPH M Industrial Vessel · MISLE 204992 · 16 September 2011 · activity 4165647

Inspection history · 89

20 November 2025 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8271596
17 September 2025 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8236340
6 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8058925
18 January 2024 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7846355
5 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7802784
4 May 2023 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7680991
11 August 2022 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7527849
11 February 2022 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7392568
16 November 2021 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7351747
19 January 2021 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7126856
21 September 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7059964
20 February 2020 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6909092
20 September 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6814978
5 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6773443
29 January 2019 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6623957
19 September 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6544208
28 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6525551
15 February 2018 Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6349767
13 December 2017 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6323839
7 December 2017 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6320033
8 August 2017 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6230573
28 November 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6049110
25 October 2016 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6029512
22 September 2016 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6006747
11 February 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5813496
3 December 2015 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5776990
1 May 2014 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4850770
17 May 2012 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4314144
1 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4299266
22 December 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4211982
16 September 2011 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4165647
26 October 2010 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3877867
10 March 2010 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3693082
30 September 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3335293
21 March 2008 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3168950
13 February 2008 Administrative Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3146773
17 October 2007 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3081835
4 September 2007 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3048035
8 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2884229
13 October 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2799743
15 September 2005 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2487352
24 August 2005 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2473409
15 February 2005 Plan Review "T" Boat · Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2292997
27 August 2004 Annual Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2173778
5 November 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1939785
3 July 2003 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1833699
18 September 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1676077
13 November 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1414029
15 August 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1431085
30 April 2001 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 464172
28 September 2000 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1417139
28 January 2000 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 815278
20 September 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1453661
8 September 1999 Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365354
21 June 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1084527
16 November 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 805201
23 June 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127365
30 October 1997 Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1455526
23 October 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1114944
1 November 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 852130
13 November 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425643
7 June 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 124708
20 December 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1382894
20 December 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461550
4 October 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429803
16 June 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151383
16 February 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432648
20 February 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947791
2 December 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252083
29 November 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250216
19 September 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934239
7 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226886
15 March 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926005
27 April 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235327
21 March 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237588
24 March 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347893
5 October 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197863
8 August 1988 Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037100
16 June 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206992
9 July 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328892
19 November 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331219
11 December 1985 COI Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 994322
30 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1288970
3 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286000
13 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972667
16 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972245
19 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966567
5 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969324
6 August 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273023

Deficiency record · 109

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 January 2025 Resolved
Semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10; the 160-B extinguisher in the engine room has not been inspected since 2022. 46 CFR 176.810 (b)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2025
Resolved 15 January 2025
Resolution: Operator ordered new semi-portable extinguisher
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 January 2025 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape. There is not adequate emergency lighting for the recently installed emergency exit leading to the bridge. 46 CFR 183.432 (a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 January 2025
Resolution: Operator installed new e-lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2023 Resolved
Prove proper operation of pressure relief valve on air receiver.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 6 October 2023
Resolution: O/O provided proof of proper operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2023 Resolved
Replace all plastic waste (trash) cans with metal cans.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 6 October 2023
Resolution: O/O provided proof of purchase of metal cans.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 November 2021 Resolved
Prove proper operation of EPIRB. During self test the EPIRB failed to operate. Vessel restricted to <3 miles from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 18 November 2021
Resolution: New EPIRB installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 November 2021 Resolved
Prove proper operation of VHF-DSC radios. Both VHF radios do not have GPS location.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2021
Resolved 17 November 2021
Resolution: GPS location was functioning on both VHF radios.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 November 2021 Resolved
Aft weathertight door has an opening for a cable pass through with no cap. Door is no longer weathertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2021
Resolved 17 November 2021
Resolution: New cap was installed on the door.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 16 November 2021 Resolved
Man overboard drill failed. Vessel captain to conduct drills for training. Drills to be conducted in the presence of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2021
Resolved 17 November 2021
Resolution: A successful drill was completed by the vessels crew.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 September 2019 Resolved
Overnight sleeping berths were found with mattresses that did not comply with 46CFR177.405(g). Provide mattresses that comply with 46CFR177.405(g).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2019
Resolved 23 October 2019
Resolution: 20 new mattresses on board that comply with standard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 September 2019 Resolved
Provide escape ladder for emergency escape from passenger berthing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2019
Resolved 23 October 2019
Resolution: provided
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 August 2019 Resolved
Provide rescue platform or equivalent and demonstrate Man Over Board drill to the satisfaction of attending marine inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 August 2019 Resolved
The refrigerator is currently using an extension cord. The hardwire cord from the fridge needs to be on continuous run or move the fixed outlet to reach properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Vessel wired the correct cable to a fixed outlet.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 August 2019 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces. There is no visual means of high level alarm.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Vessel has installed visual alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2019 Resolved
Provide latch on distribution panel in Engine Room. As well as upper deck house panel #3 missing 2 blanks.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Vessel has installed correct blanks and covered hole where latch us to be.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2019 Resolved
Provide life jacket placards for type of life jackets onboard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 August 2019 Resolved
All smoke detectors expired and need to be replaced.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: All expire smoke detectors have been replaced with new detectors.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 August 2019 Resolved
Provide gauge for fire pump. Pump shall be capable of providing 60 PSI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 20 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018 Resolved
Vsl is broadcasting broadcasting invalid MMSI, smaller than expected vessel length and invalid AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 25 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Engineering › Steering Gear System › Ram
Issued 8 August 2017 Resolved
Make permanent repair to steering ram.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 23 October 2019
Resolution: Completed
Construction/Loadline › Structures › Manhole
Issued 8 August 2017 Resolved
Make repair to forepeak hatch to ensure it maintains watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 24 August 2017
Resolution: New gasket installed.
Engineering › Lubricating Oil Service System › Gauge
Issued 8 August 2017 Resolved
Make repair to port MDE oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 24 August 2017
Resolution: Gauge repaired.
Personnel › Training › First Aid/CPR
Issued 8 August 2017 Resolved
Provide proof of training in First Aid/CPR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 24 August 2017
Resolution: CPR/first aid training provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 November 2016 Resolved
Open space in the panelboard. Provide a blank as required to cover the open space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: A blank was provided to cover the open space in the panel board.
Lifesaving › Lifebuoys › Serviceable
Issued 28 November 2016 Resolved
Life ring outside the pilot house is cracked along the seam making it unservicable. Provide a serviceable life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: A serviceable life ring has been provided.
Lifesaving › Hand Flares › Quantity
Issued 28 November 2016 Resolved
Vessel was short 01 orange Smoke. Provide 01 orange smoke to have the reqired number of hand flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: New package of orange smoke to have the reqired number of hand flares has been provided.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 November 2016 Resolved
EPIRB is not being tested monthly nor is testing that is conducted logged. Create/log monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: A log to capture monthly EPIRB tests has been created.
Stability › Incline Test › General
Issued 25 October 2016 Resolved
MEGAN T MILLER O.N. 596207 must operate within the bounds of her current stability letter with the following conditions: Max draft 7’ 9” forward, 8’ 9” aft Max deck cargo of 46 LT No crane ops. These requirements remain in effect until such time as a new stability letter is issued.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 5 December 2017
Resolution: MSC issued Stability Letter
Engineering › Compressed Air System (start air) › Valve
Issued 3 December 2015 Resolved
The compressed air system pressure relief valve was set at 200psi. The max is 165psi. Replace with correct valve and provide proof of operation to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 5 July 2016
Resolution: Valve replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 1 May 2012 Resolved
Frame #3 STBD side in the forward ballast tank was wasted and requires replacement
Condition: Placed in Improper Service
Due 1 May 2012
Resolved 7 June 2012
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 May 2012 Resolved
Area around shaft logs in mid ballast tank need to be cleaned and painted.
Condition: Placed in Improper Service
Due 1 May 2012
Resolved 7 June 2012
Construction/Loadline › Hull › Hull Plating
Issued 1 May 2012 Resolved
Bottom plate in engine room area requires cropped and replaced to good metal.
Condition: Placed in Improper Service
Due 1 May 2012
Resolved 7 June 2012
Electrical › Electric Supply System (service) › Battery Conductor
Issued 22 December 2011 Resolved
Found battery cable insulation to be loose at connection. O/O to repair insulation of cable at effected area.
Due 22 January 2012
Resolved 10 January 2012
Resolution: Repaired
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 22 December 2011 Resolved
Diesel F/O tanks and Lube Oil tanks missing sight glass guards x5. O/O to install guards.
Due 22 January 2012
Resolved 10 January 2012
Resolution: Replaced
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 December 2011 Resolved
Found Main Switchboard missing a door latch. O/O to install a locking latch to secure door cover.
Due 22 January 2012
Resolved 10 January 2012
Resolution: Repaired
Construction/Loadline › Structures › Deck Plating
Issued 22 December 2011 Resolved
Found deck plate next to fire pump in the Eng room to be not properly secured. O/O to secure deck plate to prevent plate from sliding around.
Due 22 January 2012
Resolved 10 January 2012
Resolution: Repaired
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 December 2011 Resolved
Found 2 screws missing on cover of water heater. O/O to install missing screws.
Due 22 January 2012
Resolved 10 January 2012
Resolution: Repaired
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 December 2011 Resolved
Lighting dist panel missing two insert blanks. O/O to install blanks.
Due 22 January 2012
Resolved 10 January 2012
Resolution: Repaired
Engineering › Steering Gear System › Feedback Unit
Issued 26 October 2010 Resolved
Steering Gear feedback circuit wiring was being chafed by Ram. O/O addressed problem On the Spot.
Condition: Damaged By Earlier Event
Due 27 October 2010
Resolved 27 October 2010
Resolution: Wiring moved away from ram and chafing gear installed around wiring.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 October 2010 Resolved
Freezer in storage area had mount installed but freezer was not bolted to it presenting a safety issue should the freezer fall while vessel is underway. Item corrected on the spot.
Condition: Placed in Improper Service
Due 27 October 2010
Resolved 27 October 2010
Resolution: Item corrected on the spot.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 30 September 2008 Resolved
Install dielectric matt in way of switchboard.
Condition: Improper Installation
Due 2 October 2008
Resolved 2 October 2008
Resolution: MI attended vessel and cleared requirement.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 September 2008 Resolved
Install an approved blank in circuit breaker opening on dist. panel.
Condition: Improper/Lack of Maintenance
Due 2 October 2008
Resolved 2 October 2008
Resolution: MI attended vessel and cleared requirement.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 30 September 2008 Resolved
Prove proper operation of pressure relief valve.
Condition: Placed in Improper Service
Due 2 October 2008
Resolved 2 October 2008
Resolution: MI attended vessel and cleared requirement.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 September 2008 Resolved
Install hold downs on battery box covers.
Condition: Improper/Lack of Maintenance
Due 2 October 2008
Resolved 2 October 2008
Resolution: Mi attended vessel and cleared requirement.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2007 Resolved
Original COI not on board vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2007
Resolved 18 October 2007
Resolution: Corrected
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 October 2007 Resolved
Original operators license not on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2007
Resolved 18 October 2007
Resolution: Corrected
Construction/Loadline › Structures › Air Pipe
Issued 17 October 2007 Resolved
Exterior gooseneck-vents for tanks and voids not provided with closures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2007
Resolved 18 October 2007
Resolution: Corrected
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 October 2007 Resolved
Emergency Broadcast Placard not posted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2007
Resolved 18 October 2007
Resolution: Corrected
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 September 2007 Resolved
Ensure proper operation of bildge high water alarm on bridge prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2007
Resolution: Ensured proper operation of bildge high water alarm on bridge.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 September 2007 Resolved
Provide vessel with copy of Coast Guard Light list, and coast pilot for vessels operating area.
Due 10 September 2007
Resolved 7 September 2007
Resolution: Provided vessel with copy of Coast Guard Light list, and coast pilot for vessels operating area.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 September 2007 Resolved
Provide two adult type I lifejackets to replace two adult type I lifejackets that were rejected at inspection. Vessels passenger allowance is reduced by two until completed.
Due 10 September 2007
Resolved 7 September 2007
Resolution: Provided two adult type I lifejackets to replace two adult type I lifejackets that were rejected at inspection.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 September 2007 Resolved
Clean engine room bilges of excess oily water mixture.
Due 10 September 2007
Resolved 7 September 2007
Resolution: Cleaned engine room bilges of excess oily water mixture.
Communications › Radio Communications › EPIRB
Issued 13 October 2006 Resolved
Replace cracked antenna on EPIRB.
Due 30 December 2006
Resolved 30 October 2006
Resolution: Replaced cracked antenna on EPIRB.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 13 October 2006 Resolved
Repair shutdown solinoid on stbd MDE to ensure free movement.
Due 30 October 2006
Resolved 30 October 2006
Resolution: Repaired shutdown solinoid on STBD MDE to ensure free movement.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 September 2005 Resolved
Repair/Replace outlet box cover on FWD bulkhead in galley space.
Condition: Improper/Lack of Maintenance
Due 1 October 2005
Resolved 14 October 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 September 2005 Resolved
Replace J-box cover on hot water heater supply line.
Condition: Placed in Improper Service
Due 1 October 2005
Resolved 14 October 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 September 2005 Resolved
Repair/Replace missing lagging on lagging on exhaust piping in engineroom.
Condition: Improper/Lack of Maintenance
Due 1 October 2005
Resolved 14 October 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 February 2005 Resolved
Make proper repairs to deck rails, wasted, on main deck.
Due 31 March 2005
Resolved 19 September 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 August 2004 Resolved
Conduct and log quarterly man overboard drills.
Due 3 September 2004
Resolved 1 September 2004
Resolution: Faxed copy the all drills were done for the quarter.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 August 2004 Resolved
Install high level visual bilge alarm in pitot house.
Due 10 September 2004
Resolved 2 September 2004
Resolution: Already had it but did not know where light was when set off.
Engineering › Generator (propulsion-electric) › Circuit Breaker (overload/over current protection)
Issued 27 August 2004 Resolved
Install generator distributor guard (bustie bar).
Due 10 September 2004
Resolved 2 September 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 August 2004 Resolved
Provide proof all oil transfer hoses are hydrostatically tested IAW 33 CFR 156.150.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2004
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 27 August 2004 Resolved
Provide copy of oil transfer procedures IAW 33 CFR 155.720.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2004
Resolution: Had them on the vessel the operator was not aware of them. They were updated due to the absence of a DOI being filled out, which is required by 33 CFR 156.
Communications › Internal Communications System › Portable Radios
Issued 27 August 2004 Resolved
Provide an auto start for engines in the pilot house or provide a communication system that allows the operator comms with the engine room. 46 CFR 184.602 (old T 184.35-1).
Due 10 September 2004
Resolved 6 October 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 August 2004 Resolved
Provide drawings, material specifications and breaker box blanks utilized in the main engine start system.
Action required: 705 - Other - as specified
Due 8 October 2004
Resolved 6 October 2004
Electrical › Electrical Distribution System (service)
Issued 5 November 2003 Resolved
Repair wiring from battery charfger to battery switches, remove cable splices.
Due 12 November 2003
Resolved 26 November 2003
Electrical › Lighting (service)
Issued 5 November 2003 Resolved
Repair or replace light cover in starboard engineroom.
Due 12 November 2003
Resolved 26 November 2003
Electrical › Electric Supply System (service)
Issued 5 November 2003 Resolved
Provide metal tiebacks for cable runs in the engineroom and equipment room.
Due 12 November 2003
Resolved 26 November 2003
Fire Fighting › Fire Hydrants
Issued 5 November 2003 Resolved
Provide spanner wrenches for both hose stations.
Due 12 November 2003
Resolved 26 November 2003
Lifesaving › Buoyant Apparatus
Issued 18 September 2002 Resolved
Renew sea painter for lifefloats.
Condition: Improper/Lack of Maintenance
Due 25 September 2002
Resolved 24 September 2002
Resolution: New sea painter added.
Lifesaving › Lifebuoys
Issued 18 September 2002 Resolved
Renewed stbd side wheelhouse ringbuoy.
Condition: Improper/Lack of Maintenance
Due 25 September 2002
Resolved 24 September 2002
Resolution: New ring buoy installed.
Lifesaving › Lifebuoys
Issued 18 September 2002 Resolved
Renew lines on waterlight for stbd ringbuoy & inboard lifefloat light. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 25 September 2002
Resolved 24 September 2002
Resolution: New lines placed on items.
Personnel › Certificates/Documents/Licenses
Issued 18 September 2002 Resolved
Provide copies of CG licences and marine operator permits for all of the vessel masters. LEGACY COMPONENT DESC: License, Master
Due 25 September 2002
Resolved 30 September 2002
Resolution: Crewmembers sent to Sea School for MROP. Matched certificates w/ CG licenses. Application to FCC has been made, pending MROP.
Documentation › Manuals/Policy Documentation
Issued 18 September 2002 Resolved
Update fuel transfer procedures to be IAW 33 CFR 155.720 through 155.750. LEGACY COMPONENT DESC: Transfer Procedures
Due 25 September 2002
Resolved 24 September 2002
Resolution: Transfer procedures IAW w/ 33 CFR and examined.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 18 September 2002 Resolved
Mark and hydrostatically test oil transfer hose IAW 33 CFR 154.500 as required by 33 CFR 156.120. Vessel may not use hose until completed. LEGACY COMPONENT DESC: Transfer Hose
Condition: Improper/Lack of Maintenance
Due 25 September 2002
Resolved 24 September 2002
Resolution: Hoses hydro''d and marked.
Engineering › Compressed Air System (start air)
Issued 18 September 2002 Resolved
Hydrostatically test air receiver. LEGACY COMPONENT DESC: Receiver/Bottle
Due 25 September 2002
Resolved 25 September 2002
Resolution: Air receiver tested satisfactorily by Success Corp. New 200 psi gauge installed.
Lifesaving
Issued 13 November 2001 Resolved
PROVIDE PLANS FOR PUBLIC ADDRESS SYSTEM REQUIRED UNDER 46 CFR 184.610.
Condition: Unknown
Due 7 December 2001
Resolved 13 November 2001
Resolution: Electrical plan submitted for PA system. Plan under review.
Deck/Cargo
Issued 13 November 2001 Resolved
PROVIDE AND LOG CREW TRAINING IN ACCORDANCE WITH 46 CFR 185.420.
Condition: Unknown
Due 13 February 2002
Resolved 18 September 2002
Resolution: Verified at COI exam. Drills conducted for the last year.
Lifesaving
Issued 13 November 2001 Resolved
CONDUCT AND LOG SURVIVAL CRAFT MAINTENANCE AND INSPECTIONS IAW 46 CFR 185.720.
Condition: Unknown
Due 13 February 2002
Resolved 18 September 2002
Resolution: Verified at COI exam. Checked for past year.
Lifesaving
Issued 13 November 2001 Resolved
PROVIDE TRAINING AND CONDUCT DRILLS AND LOG IAW 46 CFR 185.520 & 185.524.
Condition: Unknown
Due 13 February 2002
Resolved 18 September 2002
Resolution: Verified logs for the past year.
Navigation
Issued 13 November 2001 Resolved
PROVIDE TIDE TABLES & TIDAL CURRENT TABLES IAW 46 CFR 184.420.
Condition: Unknown
Due 7 December 2001
Resolved 4 December 2001
Resolution: Tide table book for Eastern US and tide current book for Eastern US purchased from NY Nautical. Verified via fax 11 Dec 01
Navigation
Issued 13 November 2001 Resolved
PROVIDE CORRECTED CHARTS AND CG LIGHT LIST IAW 46 CFR 184.420.
Condition: Unknown
Due 7 December 2001
Resolved 11 December 2001
Resolution: Light List received from NY Nautical 4 Dec 01. Corrected charts of LI Sound received 11 Dec 2001, they are corrected to 1 Dec 2001. Verified via fax 11 Dec 01
Navigation
Issued 13 November 2001 Resolved
REPAIR ILLUMINATING ELEMENT OF MAGNETIC COMPASS IAW 46 CFR 184.402. VESSELRESTRICTED TO DAYLIGHT OPERATIONS UNTIL REPAIRED.
Condition: Unknown
Due 7 December 2001
Resolved 13 November 2001
Resolution: New bulb installed in compass light. Confirmed via fax 11 Dec 01.
Navigation
Issued 13 November 2001 Resolved
PROVIDE TRAINING ADN PROVE OPERATION OF MF/SSB RADIO.
Condition: Unknown
Due 7 December 2001
Resolved 11 December 2001
Resolution: Recieved SSB training manual. Conducted training with all Captains. Verified vis fax 11 Dec 01.
Documentation
Issued 13 November 2001 Resolved
PROVIDE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.720 THROUGH 33 CFR 155.750.
Condition: Unknown
Due 7 December 2001
Resolved 18 September 2002
Resolution: Transfer procedures were available at COI inspection. However, not in accordance with the regulations. Have re-issued requirement.
Deck/Cargo
Issued 13 November 2001 Resolved
MARK AND HYDOSTATICALLY TEST OIL TRASNFER HOSES IAW 33 CFR 154.500 AS REQUIRED UNDER 33 CFR 156.120.
Condition: Unknown
Due 7 December 2001
Resolved 18 September 2002
Resolution: Item was not completed when checked at COI. Have re-issued this requirement.
Lifesaving
Issued 13 November 2001 Resolved
PROVIDE EPIRB IAW 46 CFR 180.64. VESSEL RESTRICTED TO NO FARTHER THAN 3 MILES FROM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 7 December 2001
Resolved 21 November 2001
Resolution: Installed new 406 EPIRB (ACR-RLB-32) on 16 Nov 01. Unit was registered with NOAA on 21 Nov 01. Confirmed via fax 11 Dec 01.
Lifesaving
Issued 13 November 2001 Resolved
PROVIDE PENDENTS FOR LIFE FLOATS IAW 46 CFR 180.75.
Condition: Unknown
Due 7 December 2001
Resolved 19 November 2001
Resolution: Pendents for lifefloats were installed on 27 Nov 01. Confirmed via fax 11 Dec 01.
Lifesaving
Issued 13 November 2001 Resolved
PROVIDE LIGHTS FOR LIFEJACKETS IAW 46 CFR 180.75. VESSEL RESTRICTED TO NO MORE THAN 20NM FROM HARBOUR OF SAFE REFUGE UNTIL COMPLETE.
Condition: Unknown
Due 7 December 2001
Resolved 19 November 2001
Resolution: All life jackets were equipped with CG approved cylume markers. Confirmed via fax 11 Dec 01.
Fire Fighting
Issued 13 November 2001 Resolved
SERVICE OR REMOVE B-IV FIRE EXTINGUISHER.
Condition: Unknown
Due 7 December 2001
Resolved 11 December 2001
Resolution: B-IV extinguisher was removed from vessel until can be properly serviced. Vessel meets minimum required fire fighting without this extinguisher.
Electrical
Issued 13 November 2001 Resolved
PROVIDE COVERS FOR JUNCTION BOXES ON FORWARD BULKHEAD IN ENGINE ROOM WORK AREA.
Condition: Unknown
Due 7 December 2001
Resolved 5 December 2001
Resolution: Cover replaced on one junction box. Second junction box replaced as new. Confirmed via fax 11 Dec 01.
Electrical
Issued 13 November 2001 Resolved
PROVIDE ELECTRICAL MAT FOR IN FRONT OF GENERATOR SWITCH PANEL.
Condition: Unknown
Due 7 December 2001
Resolved 13 November 2001
Resolution: Electrical mat placed in front of generator.
Electrical
Issued 13 November 2001 Resolved
PROVIDE COVERS FOR OPENINGS IN CIRCUIT BREAKER BOXES, (1) IN UPPER DECK HOUSE PANEL #3 AND (1) IN ENGINE ROOM PANEL #1.
Condition: Unknown
Due 7 December 2001
Resolved 11 December 2001
Resolution: Blanks placed in openings of circuit breakers. Confirmed via fax 11 Dec 01.
Electrical
Issued 13 November 2001 Resolved
PROVIDE PERMANENT WIRING (HARDWIRE) FOR BRIDGE HEATER/DEFROSTER. REMOVE/HARDWIRE RECEPTACLE.
Condition: Unknown
Due 7 December 2001
Resolved 11 December 2001
Resolution: Receptacle was removed. Bridge defroster was hardwired to electrical system.
Construction/Loadline
Issued 15 August 2001 Resolved
REPAIR/REPLACE 3' VALVE FOR BALLAST MANIFOLD.
Condition: Unknown
Due 17 August 2001
Resolved 21 November 2001
Lifesaving
Issued 28 September 2000 Resolved
PROVIDE PROPER NOAA REGISTRATION FOR THE VESSEL'S EPIRB.
Condition: Unknown
Due 20 October 2000
Resolved 17 October 2000
Construction/Loadline
Issued 28 September 2000 Resolved
MAKE ALL BALLAST AND WING TANKS AVAILABE FOR INSPECTION.
Condition: Unknown
Due 20 October 2000
Resolved 17 October 2000
Construction/Loadline
Issued 8 September 1999 Resolved
PROVIDE A MEANS OF SECURING THE SEGRAGATION VALVE BTW THE BILGE AND BALLASTTANK MANIFOLD.
Condition: Unknown
Due 17 September 1999
Resolved 20 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
REMOVE ALL WATER FROM PORT AND STBD WING TANKS AND STBD PEAK TANK TO FACILITATE INSPECTION.
Condition: Unknown
Due 17 September 1999
Resolved 20 September 1999
Navigation
Issued 23 June 1998 Resolved
Provide written documentation that vessel complies with all FCC regulationsfor a small passenger vessel operating on an OCEANS route up to 200 miles from shore. Vessel may not operate beyond 100 miles from shore until this requirement is complied with.
Condition: Unknown
Due 31 July 1998
Resolved 26 June 1998
Construction/Loadline
Issued 30 October 1997 Resolved
MAKE THE BALLAST TANKS & THE FRESH WATER TANK IN THE SPACE AFT OF THE ENGINE ROOM AVAILABLE TO EXAMINE. SPACE TO BE CLEAN & SAFE FOR MEN TO ENTER.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Documentation
Issued 23 October 1997 Resolved
REMARK NAME ON VESSEL'S STERN.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Lifesaving
Issued 1 November 1996 Resolved
RENEW RETRO ON ALL LIFE JACKETS.
Condition: Unknown
Due 1 November 1996
Resolved 4 November 1996
Lifesaving
Issued 1 November 1996 Resolved
RENEW WEBBING ON 2 L/F'S, RENEW NETTING ON 1 L/F, RENEW NETTING AND FRAME ON ANOTHER L/F.
Condition: Unknown
Due 1 November 1996
Resolved 4 November 1996
Documentation
Issued 1 November 1996 Resolved
PROVIDE A STATION BILL IAW 46 CFR 185.514.
Condition: Unknown
Due 1 November 1996
Resolved 4 November 1996
Lifesaving
Issued 1 November 1996 Resolved
PROVIDE AND PROPERLY INSTALL METAL DRYER DUCTING.
Condition: Unknown
Due 1 November 1996
Resolved 4 November 1996
Documentation
Issued 1 November 1996 Resolved
OBTAIN FCC LICENSE/CERTIFICATE.
Condition: Unknown
Due 26 November 1996
Resolved 25 November 1996
Lifesaving
Issued 1 November 1996 Resolved
SECURE WASHER, DRYER, AND FREEZER.
Condition: Unknown
Due 1 November 1996
Resolved 4 November 1996
Lifesaving
Issued 1 November 1996 Resolved
RENEW GASKETS AND CLEAN KNIFE EDGES ON WATERTIGHT DOORS.
Condition: Unknown
Due 1 November 1996
Resolved 4 November 1996
Engineering
Issued 15 March 1991 Resolved
PROVIDE MAIN ENGINE STARTS AND STOPS IN PILOTHOUSE. [46CFR 175.10-29]
Condition: Unknown
Due 15 March 1991
Resolved 15 March 1991

Casualty record · 2

16 September 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4165647
15 August 2012Routine · role: Involved in a Marine Casualty · activity 4419119
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.