Records from 2011 to 2025. Most recent: inspection, 20 November 2025.
Inspection history · 25
20 November 2025
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8271596
17 September 2025
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8236340
6 January 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8058925
18 January 2024
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7846355
5 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7802784
4 May 2023
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7680991
11 August 2022
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7527849
11 February 2022
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7392568
16 November 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7351747
19 January 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7126856
21 September 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7059964
20 February 2020
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6909092
20 September 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6814978
5 August 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6773443
29 January 2019
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6623957
19 September 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6544208
28 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6525551
15 February 2018
Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6349767
13 December 2017
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6323839
7 December 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6320033
8 August 2017
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6230573
28 November 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6049110
25 October 2016
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6029512
22 September 2016
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6006747
11 February 2016
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5813496
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 January 2025
Resolved
Semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10; the 160-B extinguisher in the engine room has not been inspected since 2022.
46 CFR 176.810 (b)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2025
Resolved 15 January 2025
Resolution: Operator ordered new semi-portable extinguisher
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 January 2025
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape. There is not adequate emergency lighting for the recently installed emergency exit leading to the bridge.
46 CFR 183.432 (a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 January 2025
Resolution: Operator installed new e-lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2023
Resolved
Prove proper operation of pressure relief valve on air receiver.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 6 October 2023
Resolution: O/O provided proof of proper operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2023
Resolved
Replace all plastic waste (trash) cans with metal cans.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 6 October 2023
Resolution: O/O provided proof of purchase of metal cans.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 November 2021
Resolved
Prove proper operation of EPIRB. During self test the EPIRB failed to operate. Vessel restricted to <3 miles from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 18 November 2021
Resolution: New EPIRB installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 November 2021
Resolved
Prove proper operation of VHF-DSC radios. Both VHF radios do not have GPS location.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2021
Resolved 17 November 2021
Resolution: GPS location was functioning on both VHF radios.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 November 2021
Resolved
Aft weathertight door has an opening for a cable pass through with no cap. Door is no longer weathertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2021
Resolved 17 November 2021
Resolution: New cap was installed on the door.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 16 November 2021
Resolved
Man overboard drill failed. Vessel captain to conduct drills for training. Drills to be conducted in the presence of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2021
Resolved 17 November 2021
Resolution: A successful drill was completed by the vessels crew.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 September 2019
Resolved
Overnight sleeping berths were found with mattresses that did not comply with 46CFR177.405(g). Provide mattresses that comply with 46CFR177.405(g).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2019
Resolved 23 October 2019
Resolution: 20 new mattresses on board that comply with standard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 September 2019
Resolved
Provide escape ladder for emergency escape from passenger berthing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2019
Resolved 23 October 2019
Resolution: provided
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 August 2019
Resolved
Provide rescue platform or equivalent and demonstrate Man Over Board drill to the satisfaction of attending marine inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 August 2019
Resolved
The refrigerator is currently using an extension cord. The hardwire cord from the fridge needs to be on continuous run or move the fixed outlet to reach properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Vessel wired the correct cable to a fixed outlet.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 August 2019
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces. There is no visual means of high level alarm.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Vessel has installed visual alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2019
Resolved
Provide latch on distribution panel in Engine Room. As well as upper deck house panel #3 missing 2 blanks.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Vessel has installed correct blanks and covered hole where latch us to be.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2019
Resolved
Provide life jacket placards for type of life jackets onboard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 August 2019
Resolved
All smoke detectors expired and need to be replaced.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: All expire smoke detectors have been replaced with new detectors.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 August 2019
Resolved
Provide gauge for fire pump. Pump shall be capable of providing 60 PSI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 20 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018
Resolved
Vsl is broadcasting broadcasting invalid MMSI, smaller than expected vessel length and invalid AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 25 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Engineering › Steering Gear System › Ram
Issued 8 August 2017
Resolved
Make permanent repair to steering ram.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 23 October 2019
Resolution: Completed
Construction/Loadline › Structures › Manhole
Issued 8 August 2017
Resolved
Make repair to forepeak hatch to ensure it maintains watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 24 August 2017
Resolution: New gasket installed.
Engineering › Lubricating Oil Service System › Gauge
Issued 8 August 2017
Resolved
Make repair to port MDE oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 24 August 2017
Resolution: Gauge repaired.
Personnel › Training › First Aid/CPR
Issued 8 August 2017
Resolved
Provide proof of training in First Aid/CPR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 24 August 2017
Resolution: CPR/first aid training provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 November 2016
Resolved
Open space in the panelboard. Provide a blank as required to cover the open space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: A blank was provided to cover the open space in the panel board.
Lifesaving › Lifebuoys › Serviceable
Issued 28 November 2016
Resolved
Life ring outside the pilot house is cracked along the seam making it unservicable. Provide a serviceable life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: A serviceable life ring has been provided.
Lifesaving › Hand Flares › Quantity
Issued 28 November 2016
Resolved
Vessel was short 01 orange Smoke. Provide 01 orange smoke to have the reqired number of hand flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: New package of orange smoke to have the reqired number of hand flares has been provided.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 November 2016
Resolved
EPIRB is not being tested monthly nor is testing that is conducted logged. Create/log monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 30 November 2016
Resolution: A log to capture monthly EPIRB tests has been created.
Stability › Incline Test › General
Issued 25 October 2016
Resolved
MEGAN T MILLER O.N. 596207 must operate within the bounds of her current stability letter with the following conditions:
Max draft 7’ 9” forward, 8’ 9” aft
Max deck cargo of 46 LT
No crane ops.
These requirements remain in effect until such time as a new stability letter is issued.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 5 December 2017
Resolution: MSC issued Stability Letter