MAURY USCG vessel records
← All vessels

CALYPSO

Built
1978
Last inspected
28 October 2021
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 October 2021
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2869
Flag
UNITED STATES
Maury page id
psix-49803

Documentation record

Registered dimensions (L × B × D)34.1 ft × 13.6 ft × 6.3 ft
Registered tonnagegross 16 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderENSIGN YACHTS · FORT LAUDERDALE, FL, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 44 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

28 October 2021 Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390791
2 March 2021 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7148898
25 November 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7101752
24 October 2019 Examination of Repairs · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6841635
7 November 2018 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577858
25 July 2018 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6490840
27 November 2017 Damage Survey · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6313585
26 November 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6314493
17 October 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6297882
17 August 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6241769
9 November 2016 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6038388
7 September 2016 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5994598
10 February 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5887974

Deficiency record · 44

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2021 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The annual inspection was due on 30 October 2020. A Renewal COI inspection must be conducted prior to carriage of passengers for hire. 46CFR176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Vessel's port side engine room ventilation cover damaged and no longer closes duct for space protected by fixed gas extinguishing system allowing extinguishing agent to vent freely. 46 CFR 182.465 (h)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2019
Resolved 6 November 2019
Resolution: Rebuilt vent cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2019 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Fuel leak on supply line to main engine cylinder. Complete repairs prior to movement. 46 CFR 182.01-5 (a)
Action required: 60 - Rectify deficiencies prior to movement
Due 25 October 2019
Resolved 28 October 2019
Resolution: Fuel line replaced in kind. Witnessed operation of main engine without fuel leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2019 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Main engine mount fractured. Provide repair plan to satisfaction of marine inspector. 46 CFR 182.01-5 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2019
Resolved 28 October 2019
Resolution: Both forward engine mounts replaced in kind. Engine witnessed in operation with no movement noted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 October 2019 Resolved
The owner or managing operator must provide satisfactory evidence to the marine inspector of the required servicing for a fire extinguishing system required to be installed per 46 CFR 181.400. Fixed fire extinguishing system installed to protect the engine room was last serviced in July 2018. Provide a service report by a qualified servicing facility for the fixed fire extinguishing system located in the engine compartment. 46 CFR 176.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2019
Resolved 28 October 2019
Resolution: Fixed fire extinguishers serviced by third party. Witnessed engine shutdown and override procedure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. Vessel may not carry passengers past 31OCT19. 46 CFR 176.404 (a)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2019
Resolved 5 November 2019
Resolution: Satisfactory drills complete.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2019 Resolved
All connections shall be made to the battery terminals with permanent type connectors. Connections on batteries made with non permanent connectors. 46 CFR 183.05-20 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 5 November 2019
Resolution: permanent connectors installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2019 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Fuel shut off valves missing labeling. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 5 November 2019
Resolution: Fuel shut off's labeled
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2019 Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories as UL Boat or UL marine cable. Cable supplying speakers not marine grade. 46 CFR 183.340 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 28 October 2019
Resolution: Speaker wire removed and replaced with 18AWG marine grade conductors.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 October 2019 Resolved
Each survival craft must be: secured to the vessel by a painter with a float-free link permanently attached to the vessel. Life float painter not attached to the vessel. 46 CFR 180.130 (a)(1)
Action required: 10 - Deficiency Rectified
Resolved 24 October 2019
Resolution: Attached painter to life float
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019 Resolved
The owner or operator must make the vessel available for all specific inspections and drills required by subpart H of this part. In accordance with Work Instruction 31 provide reduced manning written policy. 46 CFR 176.404 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 24 November 2019
Resolution: Policy recieved.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2019 Resolved
A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant OCMI. Vessel has hand tiller for auxiliary steering, however use of tiller required additional tools and several steps prior to operation. Provide dedicated emergency steering tool kit and detailed procedure for auxiliary steering operation. 46 CFR 182.620 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 6 November 2019
Resolution: Provided emergency steering tool kit and instructions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
Complete DAPI audit with the presence of a Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 5 September 2018
Resolution: Drug program is run through Maritime consortium. Seafox, Moemac, Enzo, Dive Barge, Seahound & South Seas II are all vessels covered. DAPI audit completed 05SEP2017. Activity #6254996. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
FCC operator's permit not present during time of inspection. Provide operator's permit. IAW 47CFR13.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 1 August 2018
Resolution: Master provided FFC operators permit. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
Provide CG approved policy IAW Work Instruction 31.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 1 August 2018
Resolution: Vessel rep provide CG approved policy of WI 31 to MI. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2018 Resolved
5-B:C fire extinguisher found at operating station. Provide fire extinguisher of adequate size. 10-B:C minimum required for operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2018
Resolved 5 September 2018
Resolution: Verified adequate size extinguisher on board vessel. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 August 2018 Resolved
Anchor light found inoperable. Vessel restricted to daylight operation only until proper operation of navigation lights is verified by the marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 5 September 2018
Resolution: Verified proper operation of anchor light. All sat.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 November 2017 Resolved
Conductor connected from battery switch to main engine starter found corroded and with a loose connection preventing the engine from starting. Renew electrical conductor in accordance with vessel plans. Prove operation of main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Electrical conductor renewed as per original approved plans.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 November 2017 Resolved
MI discovered welding cable installed as a conductor between the main engine alternator and the battery. Wiring must be of an approved type in accordance with 46 CFR 183.340(d).
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Welding cable removed and approved conductor placed into service.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 27 November 2017 Resolved
Overcurrent protection fuses must be of cartridge type only and listed by UL. Found ANL fuses installed in the DC circuit prior to battery switch for inverter. Replace fuses with UL approved cartridge type. Battery switch must be installed on supply side of fuses.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 29 November 2017
Resolution: Fuses removed and battery switch placed into service on supply side of breakers.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 November 2017 Resolved
Main engine starter positive conductor found installed in the engine room bilge under water. Conductors must be installed as high above the bilge as possible and supported every 24 inches apart.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Conductors placed into service as high above the bilge as possible.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 27 November 2017 Resolved
Electrical connections on the batteries found corroded and loosened. Renew electrical connections on battery terminals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Electrical connections to battery terminals renewed.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 27 November 2017 Resolved
Create vapor tight seal in the bulkhead between engine compartment and battery compartment to ensure fixed suppression system is successful when operated. Multiple holes found in bulkhead providing ventilation for suppression agent to escape engine compartment when used.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Vapor tight seal found in bulkhead. Operator used expansion foam to seal holes in bulkhead where electrical wiring penetrates.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 August 2017 Resolved
Provide properly serviced fireboy for the engine compartment prior to operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 28 August 2017
Resolution: Vessel provided proper operation of serviced fireboy.
Lifesaving › Lifebuoys › Serviceable
Issued 17 August 2017 Resolved
Renew ring buoy prior to operation IAW 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 28 August 2017
Resolution: Vessel had new ring buoy.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 17 August 2017 Resolved
Provide and properly post discharge placard IAW MARPOL I.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Provided properly posted oil discharge placard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 August 2017 Resolved
Provide Coast Guard approved first aid kit prior to carrying passengers IAW 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 28 August 2017
Resolution: Provided Coast Guard approved first aid kit.
Lifesaving › Lifefloat › Serviceable
Issued 17 August 2017 Resolved
Repair broken internal netting metal retainer on the life float IAW 46 CFR 180.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Repaired mettal retainer on life float.
Engineering › Bilge Water Management System › Pump
Issued 17 August 2017 Resolved
Prove proper operation of after compartment bilge alarm IAW 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: Proved proper operation of after bilge alarm.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 17 August 2017 Resolved
Ensure installation of proper engine room vent covers IAW 46 CFR 182.465.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Dispplayed proper operation of engine room vent covers.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 August 2017 Resolved
Prove proper operation of stern navigation light, limited to daytime operation only until completion of this item IAW COLREGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Provided proper operaton of stern nav light.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 17 August 2017 Resolved
Provide written policies and emergency response procedures per Sector Honolulu Work Instruction 31.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 29 November 2017
Resolution: Vessel provided written policies and emergency response procedures per Sector Honolulu Work Instruction 31.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 August 2017 Resolved
Provide emergency instructions procedures for fire and man overboard casualties IAW 46 CFR 185.510.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 7 September 2017
Resolution: Provided emergency instructions for fire and man overboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 9 November 2016 Resolved
Ensure portable fire extinguishers onboard are located in required locations (outside engine space, operating station, accomodation space)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Extinguishers properly placed in locations specified by 46CFR
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 November 2016 Resolved
Provide a valid COD
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: COD was applied for and copy was provided to [name withheld] for review and acceptance.
Documentation › Certificates/Documents › FCC SSL
Issued 9 November 2016 Resolved
Provide a valid FCC Station license
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 22 November 2016
Resolution: Vsl Captain stopped into office and provided FCC Station License for review.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 9 November 2016 Resolved
***Provide emergency steering tiller*Tiller onboard was missing sleeve to fit properly.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: A new sleeve was fabricated and proper operation of tiller was witnessed.
Navigation › Piloting/Steering › Marine Charts
Issued 9 November 2016 Resolved
Provide current navigational charts for vessels operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: New charts purchased and placed onboard.
Communications › Radio Communications › EPIRB
Issued 9 November 2016 Resolved
Provide new hydrostatic release for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: New hydrostatic release placed on EPIRB
Documentation › Markings/Placards › Lifejacket Placard
Issued 9 November 2016 Resolved
Provide liefjacket placard for lifejacket model that is onboard.
Due 17 November 2016
Resolved 17 November 2016
Resolution: New placards paced onboard.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 November 2016 Resolved
Replace coroded and broken grounding wire on starboard fuel tank. Port fuel tank grounding wire missing, replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: New grounding wires installed on port and starboard fuel tanks.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 9 November 2016 Resolved
Replace corroded conductor connection at battery terminals, overcurrent protection for conductors, battery charger and shore power.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: corroded conductors replaced and overcurrent protection installed with proper conductor size and approval.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 November 2016 Resolved
Prior to carrying passengers, conduct emergency drills in the presence of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: MOB, Fire Drill and unresponsive diver drill conducted satisfactorily.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 November 2016 Resolved
Replace wasted/corroded bracket for B-II extinguisher
Due 17 November 2016
Resolved 17 November 2016
Resolution: new bracket installed.

Recorded names · 2

MOEMAC (2006–2015), MOE MAC (2016–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.