CALYPSO

CALYPSO is a 1978 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1985, most recently in October 2021, along with 119 deficiencies — 1 with no resolution recorded —, 3 operational controls and 5 casualty investigations between 2006 and 2017.

Records from 1985 to 2021. Most recent: inspection, 28 October 2021.

Built
1978
Last inspected
28 October 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ2869
Flag
UNITED STATES
367071520
Maury page id
psix-49803

Inspections, by type

…with no type recorded10
Years with a record 35 calendar years (1985–2021)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.1 ft × 13.6 ft × 6.3 ft
Registered tonnagegross 16 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderENSIGN YACHTS · FORT LAUDERDALE, FL, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2869MMSI 367071520 · active · compulsorily equipped · granted 17 November 2016, expires 17 November 2026
WDC7446MMSI 367071520 · expired · compulsorily equipped · granted 12 October 2005, cancelled 12 December 2015
WDA8054MMSI 369124000 · expired · compulsorily equipped · granted 1 May 2002, cancelled 7 July 2012 · licensed under a name not among this hull’s recorded names (not shown)
WSX2203MMSI not assigned · expired · compulsorily equipped · granted 2 May 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

28 October 2021 Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390791
2 March 2021 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7148898
25 November 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7101752
24 October 2019 Examination of Repairs · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6841635
7 November 2018 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577858
25 July 2018 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6490840
27 November 2017 Damage Survey · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6313585
26 November 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6314493
17 October 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6297882
17 August 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6241769
9 November 2016 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6038388
7 September 2016 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5994598
10 February 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5887974
21 September 2015 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5208080
22 August 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4965209
2 December 2011 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4200357
30 November 2010 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3901636
2 March 2009 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3425390
6 September 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3319095
4 September 2008 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3317828
27 February 2008 Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 3154853
8 November 2007 Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 3106825
2 October 2007 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3074050
18 June 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2967585
26 April 2007 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2916626
19 April 2007 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 2911772
9 February 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582404
8 January 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2751213
12 August 2005 COI Inspection · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2464168
13 October 2004 Administrative Inspection
Administrative · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2220162
17 May 2004 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2065948
11 September 2003 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1902314
26 August 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1884038
7 June 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1624031
12 March 2002 Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1493041
31 July 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1389454
17 July 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376298
7 March 2000 Deficiency Check · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1047393
14 June 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384171
29 June 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1130189
22 June 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126602
20 March 1998 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 781989
18 July 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117111
26 December 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1095670
27 June 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089283
20 February 1996 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 884291
20 July 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 876593
10 August 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173864
18 July 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180243
9 February 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 857075
15 July 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1151871
13 August 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958392
23 July 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261587
4 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952419
29 January 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952833
29 January 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1153238
12 November 1991 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 944070
22 July 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250309
24 January 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1213913
23 July 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 987420
29 March 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 907179
10 May 1989 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195368
28 July 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1039204
23 July 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330316
14 July 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1326026
24 July 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 993983
17 October 1985 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 989008
29 July 1985 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1295736

Deficiency record · 119

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2021 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The annual inspection was due on 30 October 2020. A Renewal COI inspection must be conducted prior to carriage of passengers for hire. 46CFR176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Vessel's port side engine room ventilation cover damaged and no longer closes duct for space protected by fixed gas extinguishing system allowing extinguishing agent to vent freely. 46 CFR 182.465 (h)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2019
Resolved 6 November 2019
Resolution: Rebuilt vent cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2019 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Fuel leak on supply line to main engine cylinder. Complete repairs prior to movement. 46 CFR 182.01-5 (a)
Action required: 60 - Rectify deficiencies prior to movement
Due 25 October 2019
Resolved 28 October 2019
Resolution: Fuel line replaced in kind. Witnessed operation of main engine without fuel leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2019 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Main engine mount fractured. Provide repair plan to satisfaction of marine inspector. 46 CFR 182.01-5 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2019
Resolved 28 October 2019
Resolution: Both forward engine mounts replaced in kind. Engine witnessed in operation with no movement noted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 October 2019 Resolved
The owner or managing operator must provide satisfactory evidence to the marine inspector of the required servicing for a fire extinguishing system required to be installed per 46 CFR 181.400. Fixed fire extinguishing system installed to protect the engine room was last serviced in July 2018. Provide a service report by a qualified servicing facility for the fixed fire extinguishing system located in the engine compartment. 46 CFR 176.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2019
Resolved 28 October 2019
Resolution: Fixed fire extinguishers serviced by third party. Witnessed engine shutdown and override procedure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. Vessel may not carry passengers past 31OCT19. 46 CFR 176.404 (a)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2019
Resolved 5 November 2019
Resolution: Satisfactory drills complete.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2019 Resolved
All connections shall be made to the battery terminals with permanent type connectors. Connections on batteries made with non permanent connectors. 46 CFR 183.05-20 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 5 November 2019
Resolution: permanent connectors installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2019 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Fuel shut off valves missing labeling. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 5 November 2019
Resolution: Fuel shut off's labeled
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 October 2019 Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories as UL Boat or UL marine cable. Cable supplying speakers not marine grade. 46 CFR 183.340 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 28 October 2019
Resolution: Speaker wire removed and replaced with 18AWG marine grade conductors.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 October 2019 Resolved
Each survival craft must be: secured to the vessel by a painter with a float-free link permanently attached to the vessel. Life float painter not attached to the vessel. 46 CFR 180.130 (a)(1)
Action required: 10 - Deficiency Rectified
Resolved 24 October 2019
Resolution: Attached painter to life float
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019 Resolved
The owner or operator must make the vessel available for all specific inspections and drills required by subpart H of this part. In accordance with Work Instruction 31 provide reduced manning written policy. 46 CFR 176.404 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 24 November 2019
Resolution: Policy recieved.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2019 Resolved
A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant OCMI. Vessel has hand tiller for auxiliary steering, however use of tiller required additional tools and several steps prior to operation. Provide dedicated emergency steering tool kit and detailed procedure for auxiliary steering operation. 46 CFR 182.620 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 6 November 2019
Resolution: Provided emergency steering tool kit and instructions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
Complete DAPI audit with the presence of a Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 5 September 2018
Resolution: Drug program is run through Maritime consortium. Seafox, Moemac, Enzo, Dive Barge, Seahound & South Seas II are all vessels covered. DAPI audit completed 05SEP2017. Activity #6254996. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
FCC operator's permit not present during time of inspection. Provide operator's permit. IAW 47CFR13.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 1 August 2018
Resolution: Master provided FFC operators permit. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018 Resolved
Provide CG approved policy IAW Work Instruction 31.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 1 August 2018
Resolution: Vessel rep provide CG approved policy of WI 31 to MI. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2018 Resolved
5-B:C fire extinguisher found at operating station. Provide fire extinguisher of adequate size. 10-B:C minimum required for operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2018
Resolved 5 September 2018
Resolution: Verified adequate size extinguisher on board vessel. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 August 2018 Resolved
Anchor light found inoperable. Vessel restricted to daylight operation only until proper operation of navigation lights is verified by the marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 5 September 2018
Resolution: Verified proper operation of anchor light. All sat.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 November 2017 Resolved
Conductor connected from battery switch to main engine starter found corroded and with a loose connection preventing the engine from starting. Renew electrical conductor in accordance with vessel plans. Prove operation of main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Electrical conductor renewed as per original approved plans.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 November 2017 Resolved
MI discovered welding cable installed as a conductor between the main engine alternator and the battery. Wiring must be of an approved type in accordance with 46 CFR 183.340(d).
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Welding cable removed and approved conductor placed into service.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 27 November 2017 Resolved
Overcurrent protection fuses must be of cartridge type only and listed by UL. Found ANL fuses installed in the DC circuit prior to battery switch for inverter. Replace fuses with UL approved cartridge type. Battery switch must be installed on supply side of fuses.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 29 November 2017
Resolution: Fuses removed and battery switch placed into service on supply side of breakers.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 November 2017 Resolved
Main engine starter positive conductor found installed in the engine room bilge under water. Conductors must be installed as high above the bilge as possible and supported every 24 inches apart.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Conductors placed into service as high above the bilge as possible.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 27 November 2017 Resolved
Electrical connections on the batteries found corroded and loosened. Renew electrical connections on battery terminals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Electrical connections to battery terminals renewed.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 27 November 2017 Resolved
Create vapor tight seal in the bulkhead between engine compartment and battery compartment to ensure fixed suppression system is successful when operated. Multiple holes found in bulkhead providing ventilation for suppression agent to escape engine compartment when used.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 29 November 2017
Resolution: Vapor tight seal found in bulkhead. Operator used expansion foam to seal holes in bulkhead where electrical wiring penetrates.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 August 2017 Resolved
Provide properly serviced fireboy for the engine compartment prior to operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 28 August 2017
Resolution: Vessel provided proper operation of serviced fireboy.
Lifesaving › Lifebuoys › Serviceable
Issued 17 August 2017 Resolved
Renew ring buoy prior to operation IAW 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 28 August 2017
Resolution: Vessel had new ring buoy.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 17 August 2017 Resolved
Provide and properly post discharge placard IAW MARPOL I.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Provided properly posted oil discharge placard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 August 2017 Resolved
Provide Coast Guard approved first aid kit prior to carrying passengers IAW 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 28 August 2017
Resolution: Provided Coast Guard approved first aid kit.
Lifesaving › Lifefloat › Serviceable
Issued 17 August 2017 Resolved
Repair broken internal netting metal retainer on the life float IAW 46 CFR 180.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Repaired mettal retainer on life float.
Engineering › Bilge Water Management System › Pump
Issued 17 August 2017 Resolved
Prove proper operation of after compartment bilge alarm IAW 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: Proved proper operation of after bilge alarm.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 17 August 2017 Resolved
Ensure installation of proper engine room vent covers IAW 46 CFR 182.465.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Dispplayed proper operation of engine room vent covers.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 August 2017 Resolved
Prove proper operation of stern navigation light, limited to daytime operation only until completion of this item IAW COLREGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 August 2017
Resolution: Provided proper operaton of stern nav light.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 17 August 2017 Resolved
Provide written policies and emergency response procedures per Sector Honolulu Work Instruction 31.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 29 November 2017
Resolution: Vessel provided written policies and emergency response procedures per Sector Honolulu Work Instruction 31.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 August 2017 Resolved
Provide emergency instructions procedures for fire and man overboard casualties IAW 46 CFR 185.510.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 7 September 2017
Resolution: Provided emergency instructions for fire and man overboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 9 November 2016 Resolved
Ensure portable fire extinguishers onboard are located in required locations (outside engine space, operating station, accomodation space)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Extinguishers properly placed in locations specified by 46CFR
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 November 2016 Resolved
Provide a valid COD
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: COD was applied for and copy was provided to [name withheld] for review and acceptance.
Documentation › Certificates/Documents › FCC SSL
Issued 9 November 2016 Resolved
Provide a valid FCC Station license
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 22 November 2016
Resolution: Vsl Captain stopped into office and provided FCC Station License for review.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 9 November 2016 Resolved
***Provide emergency steering tiller*Tiller onboard was missing sleeve to fit properly.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: A new sleeve was fabricated and proper operation of tiller was witnessed.
Navigation › Piloting/Steering › Marine Charts
Issued 9 November 2016 Resolved
Provide current navigational charts for vessels operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: New charts purchased and placed onboard.
Communications › Radio Communications › EPIRB
Issued 9 November 2016 Resolved
Provide new hydrostatic release for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: New hydrostatic release placed on EPIRB
Documentation › Markings/Placards › Lifejacket Placard
Issued 9 November 2016 Resolved
Provide liefjacket placard for lifejacket model that is onboard.
Due 17 November 2016
Resolved 17 November 2016
Resolution: New placards paced onboard.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 November 2016 Resolved
Replace coroded and broken grounding wire on starboard fuel tank. Port fuel tank grounding wire missing, replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: New grounding wires installed on port and starboard fuel tanks.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 9 November 2016 Resolved
Replace corroded conductor connection at battery terminals, overcurrent protection for conductors, battery charger and shore power.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: corroded conductors replaced and overcurrent protection installed with proper conductor size and approval.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 November 2016 Resolved
Prior to carrying passengers, conduct emergency drills in the presence of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2016
Resolution: MOB, Fire Drill and unresponsive diver drill conducted satisfactorily.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 November 2016 Resolved
Replace wasted/corroded bracket for B-II extinguisher
Due 17 November 2016
Resolved 17 November 2016
Resolution: new bracket installed.
Construction/Loadline › Structures › Scuttle
Issued 21 September 2015 Resolved
Address wood rot/angel hair IWO emergency escape hatch.
Condition: Improper/Lack of Maintenance
Due 5 October 2015
Resolved 1 October 2015
Resolution: Angel hair was removed from area and rotted wood was removed and replaced as new.
Engineering › Bilge Water Management System › Valve
Issued 30 November 2010 Resolved
Remove check valves from bilge pump discharge hoses and install positive action valves at the thru hull fittings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 30 November 2010 Resolved
Provide (2) BII fire extinguishers IAW COI. Vessel not allowed to carry passengers until provided on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2010
Resolved 2 December 2010
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 30 November 2010 Resolved
Seal penetrations in engine for fwd and aft engine room blkhds. Space is protected by pre engineered system and should be vapor tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Fire Fighting › Ventilation Systems › Ducts
Issued 30 November 2010 Resolved
Make engine room ventilation covers vapor tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Lifesaving › Hand Flares › Expired
Issued 30 November 2010 Resolved
Provide (6) red flares and (3) orange smoke flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2010
Resolved 2 December 2010
Operations/Management › Drills/Instruction › Fire
Issued 30 November 2010 Resolved
Post emergency current emergency instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 November 2010 Resolved
Post EAP information, policy statement and hotline number.
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 November 2010 Resolved
Provide proof of supervisors (1) hour EAP training.
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 November 2010 Resolved
Provide SAP name and contact information.
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 4 January 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 March 2009 Resolved
Remove battery charger or submit plans for approval for charger.
Action required: 705 - Other - as specified
Due 14 October 2009
Resolved 25 August 2010
Resolution: Battery charger was removed.
Construction/Loadline › Hull › Stiffener
Issued 2 March 2009 Resolved
Treat wood rot in identified areas at starboard forward post of engine room along starboard side of engine, and in the overhead beams of storage closet area on starboard side.
Action required: 705 - Other - as specified
Due 14 October 2009
Resolved 25 August 2010
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 2 March 2009 Resolved
Provide proof of servicing for all fire extinguishers and fixed system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2009 Resolved
Submit plans and specifications for approval of all electrical systems and wiring on board the vessel.
Action required: 705 - Other - as specified
Due 14 October 2009
Resolved 12 November 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 September 2008 Resolved
Vessel has exceeded the deadline of 90 days from their anniversary date on their second annual exam. Vessel is prohibited from carrying passengers for hire until a new COI is issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 September 2008 Resolved
Provide current tide table, coast pilot, light list, and rules of the road.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 September 2008 Resolved
Provide drill log and log of monthly EPIRB tests and maintenance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 September 2008 Resolved
Properly install EPIRB with current hydrostatic release, battery, and NOAA registration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 September 2008 Resolved
Replace expired items in first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 September 2008 Resolved
Complete satisfactory DAPI audit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Construction/Loadline › Hull › Stiffener
Issued 4 September 2008 Resolved
Treat area of rot identified in forward accommodation space overhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 September 2008 Resolved
Install railings in two areas behind wheelhouse in accordance with 46 CFR 177.90.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 September 2008 Resolved
Provide expiration dates or replace waterlight batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 September 2008 Resolved
Secure, remove, or properly dead end loose wiring under control station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Lifesaving › Lifefloat › Retroreflective Material
Issued 4 September 2008 Resolved
Renew or replace retroreflective tape on the lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Lifesaving › Lifefloat › Markings
Issued 4 September 2008 Resolved
Mark lifefloat and paddles with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Lifesaving › Lifefloat › Float-free Link
Issued 4 September 2008 Resolved
Properly attach lifefloat with appropriate sized weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Lifesaving › Lifefloat › Serviceable
Issued 4 September 2008 Resolved
Repair lifefloat with approved repair kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 4 September 2008 Resolved
Properly install existing FireBoy system to allow for automatic actuation by a heat detector and to automatically shut down engine upon activation in accordance with 46 CFR 181.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2007 Resolved
Provide crew and complete fire and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 21 June 2007
Resolution: Completed satisfactory drills.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 June 2007 Resolved
Provide drug and alcohol testing documentation for audit. (Audit completed 18JUL2007). Complete pre-employment drug tests or prove crewmember participation in a random testing program 185 days prior o 18JUN2007 or passing of a drug test since 18DEC2006. Provide Hotline number iaw 46CFR Part 16.
Due 17 August 2007
Resolved 2 October 2007
Resolution: Sighted pre-employment drug screening tests for current employees.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 June 2007 Resolved
Provide proof of Red Cross CPR/1st aid certification for 50% of crew. (1 of 2).
Due 18 July 2007
Resolved 21 June 2007
Resolution: Sighted current 1st Aid/CPR certification.
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 June 2007 Resolved
Provide an illuminated magnetic compass. 46CFR184.402.
Due 25 June 2007
Resolved 21 June 2007
Resolution: Sighted installed compass.
Lifesaving › Hand Flares › Not on Board
Issued 18 June 2007 Resolved
Provide a total of (6) red handheld flares and (6) orange handheld smoke signals. 46CFR180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 21 June 2007
Resolution: Sighted correct number of valid smokes and flares.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 18 June 2007 Resolved
Provide a 1st aid kit. 46CFR184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 21 June 2007
Resolution: Sighted new USCG approved 1st aid kit.
Fire Fighting › Fire Bucket › Quantity
Issued 18 June 2007 Resolved
Provide a total of (3) 2.5 gallon fire buckets. 46CFR181.610.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 21 June 2007
Resolution: Sighted (3) properly sized fire buckets.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 18 June 2007 Resolved
Provide ventilation closures for the machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 21 June 2007
Resolution: Sighted ventilation closures.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 June 2007 Resolved
Provide (2) flashlights for portable lighting. 46CFR183.430.
Due 25 June 2007
Resolved 21 June 2007
Resolution: Sighted (2) working flashlights dedicated for use on the boat.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 18 June 2007 Resolved
Provide an Oil Pollution placard. 33CFR155.450.
Due 25 June 2007
Resolved 21 June 2007
Resolution: Sighted oil pollution placard mounted where clearly seen.
Stability › Weathertight Integrity › General
Issued 18 June 2007 Resolved
Provide rubber seals for weather tight hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 21 June 2007
Resolution: Gasket material has been applied to the underside surface of the hatch covers.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 June 2007 Resolved
Properly mark the remote fuel shut-off valves locations. 46CFR185.608.
Due 24 June 2007
Resolved 18 July 2007
Resolution: Sighted markings for remote fuel shut-off valves.
Construction/Loadline › Hull › Keel
Issued 12 August 2005 Resolved
Reef out and recaulk seam at aded keel, repair minor rot where noted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2005
Resolved 23 August 2005
Resolution: Corrected
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 August 2005 Resolved
Replace rotted deck beams, supports and brackets in engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2005
Resolved 19 January 2006
Resolution: cORRECTED
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 August 2005 Resolved
Replace worn strut bearing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2005
Resolved 23 August 2005
Resolution: replaced.
Documentation › Certificates/Documents
Issued 26 August 2003 Resolved
Post COI.
Due 10 September 2003
Resolved 10 September 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 August 2003 Resolved
Prove servicing of Fixed CO2 fire system.
Due 10 September 2003
Resolved 10 September 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 26 August 2003 Resolved
Provide B-I extinguisher for pilothouse. LEGACY COMPONENT DESC: Number
Due 10 September 2003
Resolved 10 September 2003
Communications › Radio Communications
Issued 26 August 2003 Resolved
Reposition EPIRB to float free area.
Due 10 September 2003
Resolved 10 September 2003
Lifesaving › Buoyant Smoke Signals
Issued 26 August 2003 Resolved
Provide 4 hand red and 5 hand orange smoke flares.
Due 10 September 2003
Resolved 10 September 2003
Communications › Alarms/Indicators
Issued 26 August 2003 Resolved
Prove operation of #2 bilge high level alarm. LEGACY COMPONENT DESC: High Water Alarm
Due 10 September 2003
Resolved 10 September 2003
Operations/Management › Passenger Operations
Issued 26 August 2003 Resolved
Leave passenger count with shore personnel.
Due 10 September 2003
Resolved 10 September 2003
Navigation › Collision/Grounding Avoidance
Issued 26 August 2003 Resolved
Repair starboard running light. LEGACY COMPONENT DESC: Navigation Lights
Due 10 September 2003
Resolved 10 September 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 August 2003 Resolved
Provide 2 portable emergency lights.
Due 10 September 2003
Resolved 10 September 2003
Fire Fighting › Miscellaneous Items
Issued 26 August 2003 Resolved
Provide 3 2.5 gallon fire buckets with lanyards.
Due 10 September 2003
Resolved 10 September 2003
Navigation › Piloting/Steering
Issued 26 August 2003 Resolved
Provide tide tables for area transitted. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 10 September 2003
Resolved 10 September 2003
Communications › Alarms/Indicators
Issued 7 June 2002 Resolved
High level alarm has one light and buzzer for all compartments. Provide light for each compartment. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 25 July 2002
Electrical › Electric Supply System (service)
Issued 7 June 2002 Resolved
Cover missing on starting battery. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 24 July 2002
Fire Fighting › Fixed Fire Detection System
Issued 7 June 2002 Resolved
No fire detection, vsl has two extinguishing system, one CO2 for shut down and one halon 1301. Both of which are not approved. Provide a detection system prior to carrying passengers. Provide plans on installing a CG approve fire extinguishing system. LEGACY COMPONENT DESC: Heat Detectors
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2002
Resolved 23 September 2002
Resolution: Witnessed test of new CG approved system.
Lifesaving › Hand Flares › Quantity
Issued 7 June 2002 Resolved
No smoke flares. Provide six smoke flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 24 July 2002
Lifesaving › Launching Appliances › Release Mechanism
Issued 7 June 2002 Resolved
Life float painter not attached to weak link, paddles not attached. Repair/renew.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 25 July 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2002 Resolved
First Aid Kit incomplete. Provide kit that meets 46CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 24 July 2002
Operations/Management › Drug and Alcohol Testing
Issued 7 June 2002 Resolved
Drug testing incomplete. Provide proof of preemployment, EAP serious marine incident testing and policy. LEGACY COMPONENT DESC: Testing, Pre-employment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 24 July 2002
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 June 2002 Resolved
No waste management program. Provide plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 24 July 2002
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 June 2002 Resolved
Emergency instruction not vessel spacific, no emergency broadcast plan. Update plans
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 24 July 2002
Documentation
Issued 7 June 2002 Resolved
Provide proof of paying User Fee.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2003
Resolved 20 January 2003
Construction/Loadline
Issued 7 March 2000 Resolved
INSTALL POSITIVE CLOSURE VALVES ON ALL THRU HULL FITTINGS WITHIN 6 INCHES OF DEEPEST LOAD WATERLINE.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Lifesaving
Issued 22 June 1998 Resolved
RENEW RETRO-REFLECTIVE TAPE ON ALL ADULT LIFE PRESERVERS AND RING BUOY.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Construction/Loadline
Issued 20 March 1998 Resolved
INSTALL SEA VALVES ON ALL THROUGH HULL FITTINGS WITHIN 6 INCHES OF DEEPEST LOAD WATERLINE, WHERE MISSING.
Condition: Unknown
Due 20 March 1998
Resolved 25 March 1998
Documentation
Issued 27 June 1996 Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Navigation
Issued 18 July 1994 Resolved
RELOCATE STERN LIGHT SO IT IS NOT BLOCKED BY SWIM PLATFORM.
Condition: Unknown
Due 18 August 1994
Resolved 10 August 1994
Fire Fighting
Issued 18 July 1994 Resolved
PROVIDE 3 BII MARINE FIRE EXTINGUISHER BRACKETS.
Condition: Unknown
Due 18 August 1994
Resolved 10 August 1994
Lifesaving
Issued 18 July 1994 Resolved
IMPROVE FLOAT FREE ARRANGEMENT FOR LIFEFLOAT .
Condition: Unknown
Due 18 August 1994
Resolved 10 August 1994
Navigation
Issued 9 February 1994 Resolved
PROPERLY REPAIR VERTICLE CRACK IN WAY OF THE PINTLE.
Condition: Unknown
Due 9 March 1994
Resolved 19 April 1994
Lifesaving
Issued 9 February 1994 Resolved
REPLACE LIFE FLOAT HANMD LINES.
Condition: Unknown
Due 9 March 1994
Resolved 19 April 1994
Deck/Cargo
Issued 9 February 1994 Resolved
END FOR END ANCHOR LINE.
Condition: Unknown
Due 9 March 1994
Resolved 19 April 1994

Casualty record · 5

8 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2751213
10 September 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4981059
25 April 2015Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 5169396
10 February 2016Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 5887974
26 November 2017Routine · role: Involved in a Marine Casualty · activity 6314493
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

MOEMAC (2006–2015), MOE MAC (2016–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.