Records from 1981 to 2022. Most recent: inspection, 15 July 2022.
Inspection history · 55
15 July 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7507658
24 October 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6561736
15 May 2018
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6414651
22 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6359356
24 October 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293264
11 September 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6264077
29 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6009890
26 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5940195
20 July 2015
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5179170
26 August 2014
Drydock Exam · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4959805
28 July 2011
Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4090368
15 May 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3479960
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3396869
25 July 2007
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3007364
5 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2769187
15 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2743185
17 October 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2516066
2 September 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2481717
17 August 2005
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2466159
4 October 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2213273
24 June 2004
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2109085
27 April 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2053962
18 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2050983
23 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1934314
26 June 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1630262
19 November 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450705
29 August 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822907
29 August 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053873
3 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393498
22 June 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449199
3 August 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466543
18 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 452653
14 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 106378
3 June 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402471
18 June 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448794
5 June 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409326
3 June 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367072
11 June 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213329
9 June 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403638
11 June 1992
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439323
2 June 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1255144
16 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220023
19 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924449
9 April 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211838
2 September 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 498168
1 May 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041947
7 April 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209084
28 May 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336219
3 July 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985379
1 August 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986653
16 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283932
19 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282632
20 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967999
29 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966194
30 July 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973819
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 October 2018
Resolved
The vessel's AIS is not working properly. The system contiues to reboot itself. Vessel rep advised they have a new one on order
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2018
Resolved 30 October 2018
Resolution: New AIS was installed and tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
Starboard main engine has a significant exhaust leak from a bellows. Exhaust leak causes a safety concern for any crewmember that may be in the space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 October 2018
Resolved
Vessel's FCC station license is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 24 October 2018
Resolved
Vessels forward draft markings are not clearly visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2018
Resolution: draft marks repainted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018
Resolved
The stbd generator label indicates that it is only good for an ambient temperature of 40 deg C and not proven to be derated. Derate or provide manufacturer evidence that the SSG is operable in 50 deg C ambient temperature
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2018
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 October 2018
Resolved
Vessel does not have an installed fixed public address system. The system that once was onboard has been removed. Install and prove proper operation of PA system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 October 2018
Resolved
The approval and specification tag for the lifefloats was missing. The week link appeared to be of appropriate size but could not be confirmed. Replace or provide appropriate tag for week link
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2018
Resolution: New weak links installed
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 24 October 2017
Resolved
Provide proof of proper installation of engine shutdown air dampers on both main engines
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 27 October 2017
Resolution: Received tech report approving modification.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 October 2017
Resolved
Remove romex cable with proper marine grade cable under the pilot house console.
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 27 October 2017
Resolution: Cable replaced with marine grade cable.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2017
Resolved
Install proper terminal lugs on the pilot house console and battery cabling.
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 27 October 2017
Resolution: Proper terminal lugs installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 July 2016
Resolved
Port engine piping experiencing corrosion next to each of the flexible piping sections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 29 September 2016
Resolution: Witnessed replaced piping on port engine.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 20 July 2015
Resolved
Properly secure wiring of sewage pump.
Condition: Damaged By Earlier Event
Due 20 July 2015
Resolved 20 July 2015
Resolution: Rewired Sewage pump.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 July 2015
Resolved
Properly install lagging on Port and STBD main diesel engines exhaust.
Condition: Improper Installation
Due 20 August 2015
Resolved 30 July 2015
Resolution: Installed lagging.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 July 2015
Resolved
Install exhaust lagging on generator exhaust piping in laundry room.
Condition: Improper Installation
Due 20 August 2015
Resolved 30 July 2015
Resolution: Installed lagging.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 20 July 2015
Resolved
Provide means of securing man overboard recovery ladder to the rail.
Condition: Improper Installation
Due 20 August 2015
Resolved 30 July 2015
Resolution: Installed through bolts on ladder/stantion.
Communications › Audible Communications › Horn/Whistle
Issued 20 July 2015
Resolved
Install adequate sounding ships whistle/horn.
Condition: Improper/Lack of Maintenance
Due 20 August 2015
Resolved 30 July 2015
Resolution: Installed horn and new air valve.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 July 2015
Resolved
Install and tighten double nuts on port and stbd shaft packing.
Condition: Improper Installation
Due 20 July 2015
Resolved 20 July 2015
Resolution: Properly secured double nut on port and stbd shaft packing.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 September 2014
Resolved
M/I found plastic flexible hose installed and utilized as sight glass on three f/o tanks. Procure and install the proper cylindrical sight glass as required. Inspection required by the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: M/I Inspected and accepted the newly installed sight glass.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 25 September 2014
Resolved
M/I found port MDE f/o strainer bowl missing and a plastic petcock installed. New bowl and metal plug must be installed to the satisfaction of the attending M/I.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 September 2014
Resolved
M/I found emergency f/o shutdown valve inoperative. Replace and demonstrate proper operation of emergency shut down to the attending M/I.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 25 September 2014
Resolved
Emergency escape hatch from engine room to aft main deck is missing pins/hardware and dogging handle. Replace dogging handle and pins to the satisfaction of the attending M/I
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 25 September 2014
Resolved
Engine room air dampeners are not installed so in an emergency they could be properly covered. Modification need be made to dampeners so they can be properly installed/secured.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Engineering › Steering Gear System › Rudder Stock
Issued 25 September 2014
Resolved
M/I found rudder stock bolt not secured. Rudder bolt needs to be secured by weld tacking or double nuts installed to prevent rudder from backing off and or falling out. repairs to be made to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 September 2014
Resolved
M/I observed an electrical splice off lighting fixture running to receptacle in bathroom. receptacle must be replaced to ground fault indicator and inspected by satisfactory by the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 26 August 2014
Resolved
M/I observed steering chain linkage chaffing against electrical wiring run to pilot house. Wires must be made safe by rerouting so not to chaff on steering chain. To be made satisfactory to the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Fire Fighting › Fire Main › Condition
Issued 25 August 2014
Resolved
Crew did not demonstrate proper operation of the installed fire pump. Crew did not align fire system to take suction from the sea to get proper pressure at fire pump, hose and nozzle.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2014
Resolved 29 September 2014
Resolution: Inspected and found satisfactory to the attending Marine Inspector.
Construction/Loadline › Structures › Deck Plating
Issued 28 July 2011
Resolved
Engin removal patches were not welded completely or properly above both main deisel engines
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 August 2011
Resolved 25 August 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 July 2011
Resolved
Exhaust was leaking into the engine room from riser
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 August 2011
Resolved 25 August 2011
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 July 2011
Resolved
Sea chest valve was leaking excessively when not tube locked open or closed.
Action required: 705 - Other - as specified
Due 28 August 2011
Resolved 25 August 2011
Documentation › Markings/Placards › Official Number (US)
Issued 28 July 2011
Resolved
Main beam number not permanintly affixed
Action required: 705 - Other - as specified
Due 28 August 2011
Resolved 12 August 2011
Resolution: Attending Inspectors verified that vessel''''s official number was permanently affixed to interior structural member of the vessels hull.
Communications › Internal Communications System › Portable Radios
Issued 15 August 2006
Resolved
Provide public address system IAW 46 CFR 184.610
Due 15 September 2006
Resolved 5 September 2006
Fire Fighting › Fire Pumps › Pressure
Issued 23 October 2003
Resolved
Provide proof for fire pump to achieve 60 psi.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Communications › Radio Communications › EPIRB
Issued 23 October 2003
Resolved
Renew EPIRB antenna.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Lifesaving › Buoyant Apparatus
Issued 23 October 2003
Resolved
Renew upper life float tending lines and sea painter for life floats. LEGACY COMPONENT DESC: Life float
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 23 October 2003
Resolved
Make operable main engine shutdowns.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Construction/Loadline › Structures › Door
Issued 23 October 2003
Resolved
Renew engine room emergency escape hatch cover.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 October 2003
Resolved
Install emergency light fixture directed toward the lower berthing escape.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 23 October 2003
Resolved
Stencil lower berthing emergency escape.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 24 October 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 October 2003
Resolved
Renew (4) marked flexible hoses on main engines and generators. LEGACY COMPONENT DESC: Flexible Hoses
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 24 October 2003
Engineering › Fuel Oil Service System
Issued 23 October 2003
Resolved
Install flame shield on port main engine fuel filter. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 24 October 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 October 2003
Resolved
Paint background for sidelights flat black.
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 24 October 2003
Lifesaving › Lifebuoys
Issued 23 October 2003
Resolved
Renew all lines on port forward 01 deck lifebuoy and renew retro-reflective tape on (2) lifebuoys. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 24 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 9 July 2002
Resolved
NO FIXED CO2 SYSTEM FOR INSTALLED PAINT LOCKER.
Due 9 July 2002
Resolved 9 July 2002
Navigation › Piloting/Steering
Issued 9 July 2002
Resolved
NO UPDATED COMPASS DEVIATION CARD ONBOARD. LEGACY COMPONENT DESC: Compass Deviation Table
Due 9 July 2002
Resolved 9 July 2002
Stability › Watertight Integrity
Issued 9 July 2002
Resolved
ENGINE ROOM WATER TIGHT HATCH GASKET INOPERABLE. LEGACY COMPONENT DESC: WATER TIGHT HATCH GASKET
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2002
Resolved 9 July 2002
Fire Fighting › Ventilation Systems
Issued 9 July 2002
Resolved
NO MECHANICAL MEANS OF CLOSING VENT CLOSURE IN THE EVENT OF A ENGINEROOM FIRE. LEGACY COMPONENT DESC: DECK VENT CLOSURES
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2002
Resolved 9 July 2002
Construction/Loadline
Issued 3 August 2000
Resolved
Install and demonstrate proper operation of engine room bilge alarm visual indicator at the operating station to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Engineering
Issued 19 April 1991
Resolved
INSTALL START SWITCHES ON BRIDGE FOR BOTH MAIN ENGINES OR AN EFFECTIVE MEANS OF COMMUNICATION BETWEEN THE BRIDGE AND ENGINE ROOM.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991