MAURY USCG vessel records Sign in
← All vessels

GLOVIS CHORUS

GLOVIS CHORUS is a 1997 freight ship. The Coast Guard has recorded 31 inspections since 1999, most recently in May 2025, along with 14 deficiencies and 6 operational controls.

Records from 1999 to 2025. Most recent: inspection, 8 May 2025.

Built
1997
Last inspected
8 May 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9158604 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
498109
Flag
SOUTH KOREA
—
Maury page id
psix-498109

Inspections, by type

…with no type recorded10
Years with a record 15 calendar years (1999–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it21868 - Convention (Subpart B), Net Ton
21505 - Dead Weight, Metric Ton
37917 - Displacement, Metric Ton
55729 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

8 May 2025 PSC A
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8129975
25 December 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8050779
5 August 2024 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7971655
5 August 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8008303
13 January 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7620999
8 November 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7347158
30 April 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7186608
16 April 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7176411
29 October 2020 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7080687
27 October 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7085348
19 January 2019 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6608865
6 December 2017 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6316008
22 September 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6271607
24 October 2014 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5008330
23 October 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5008580
9 May 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4854444
6 February 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3676525
6 February 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3681091
19 June 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3239750
19 June 2008 MARPOL Annex V Examination · PI Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3241852
10 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2905125
12 January 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2854719
4 July 2004 PII Safety Exam · MARPOL Annex I Examination · STCW 95 Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2120524
28 June 2004 ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2114286
10 December 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1962087
8 February 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1741829
8 February 2003 Type not recorded
No type recorded · USCGC STEADFAST (WMEC 623) · Activity 1746032
28 October 2002 Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1696992
28 October 2002 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1697242
30 June 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 430156
25 June 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 429985

Deficiency record · 14

05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 5 August 2024 Resolved
Subject to the provisions of paragraph 4.1, ships shall automatically transmit the following long-range identification and tracking information: 1, identity of the ship; 2, the position of the ship; 3, the date and time of the position provided. PSCO observed LRIT in non-working order, needs replacement. 74 SOLAS (20) v/19-1.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2024
Resolved 25 December 2024
Resolution: Received documentation from class attesting to satisfactory repairs.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 5 August 2024 Resolved
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 August 2024
Resolved 5 August 2024
Resolution: Received bunkers to get sulfur content less than .1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2020 Resolved
DETECTORS AND MANUALLY OPERATED CALL POINTS SHALL BE GROUPED INTO SECTIONS. TH ACTIVATION OF ANY DETECTOR OR MANUALLY OPERATED CALL POINT SHALL INITIATE A VISUAL AND AUDIBLE FIRE SIGNAL AT THE CONTROL PANEL AND INDICATING UNITS. PORT STATE CONTROL OFFICERS DISCOVERED THE FIRE INDICATING UNIT IN THE ENGINE CONTROL ROOM WAS NOT FUNCTIONING. CREW WAS ABLE TO RECTIFY THE DEFICIENCY PRIOR TO EXAM COMPLETION. 01 SOLAS II-2/13.1.4 Action Taken:10 C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2020
Resolved 29 October 2020
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 22 September 2017 Resolved
9900: Ship's shall maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implentation to understand the plan and include a detailing biofouling maintenance and sediment removal procedures. 33CFR151.2050g
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 22 September 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2014 Resolved
All electrical cables and wiring external to equipment shall be at least of a flame retardant type and shall be so installed as not to impair their original flame retarding properties. PSCO found numerous wires on the incinerator improperly repaired, degrading the wires flame retarding properties. 74SOLAS(04Cons) II-1/45.5.2 40a.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 October 2014
Resolution: Received Class report attesting to the repairs and proper operation of the equipment.
Engineering › Fuel Oil Service System › Pump
Issued 24 October 2014 Resolved
Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter or heater from coming into contact with heated surfaces. The main engine had fuel oil leaks on the #3, #4 and #5 high pressure fuel pumps. Also, fuel strainers and lines on two of the three generators had fuel oil leaks. 74 SOLAS (97 Cons) II-2/15.2.4 17c.
Condition: Improper/Lack of Maintenance
Due 24 October 2014
Resolved 24 October 2014
Resolution: Corrected by vessel prior to PSCO departure. Def cleared on Form B
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 October 2014 Resolved
After any survey of ship has been completed, no change shall be made in the equipment, systems, fittings, or arrangements covered by the survey without sanction of the administration. PSCO discovered ship had an OWS approved under MEPC 60(33), as reflected by the IOPP and a second OWS approved under MEPC 107(49), the second OWS is not reflected on the IOPP and is the OWS Currently being used. 16b
Condition: Improper Installation
Due 7 November 2014
Resolved 31 October 2014
Resolution: Received Class Report attesting to the changes to the IOPP to reflect the correct equipment that the vessel is fitted with.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 24 October 2014 Resolved
In every case, the administration concerned shall fully guarantee the completeness and efficiency of the survey and shall undertake to ensure the necessary arrangements to satisfy obligation. IOPP reflected presence of incinerator onboard ship. IAPP certificate did not address the presence of the Incinerator. MARPOL VI/ 5.3.4 40a.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 October 2014
Resolved 31 October 2014
Resolution: Received Class Report attesting to the correction to the IAPP to reflect that the vessel is fitted with a incinerator.
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 October 2014 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO found various leaks in steering gear room and pumps. 74SOLAS(09 Cons.) I/11(a) 40c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 October 2014
Resolution: Def was corrected prior to PSCO departure from vessel.
Engineering › Steam Boiler (auxiliary/waste heat) › Furnace
Issued 24 October 2014 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO noted Auxiliary Boiler was open for maintenance. Boiler Tech. was onboard but was unable to repair on site. RO/RSO to prove proper operation of Auxiliary Boiler upon repair. 74SOLAS(09 Cons.) I/11(a) 16a.
Due 10 November 2014
Resolved 31 October 2014
Resolution: Received Class Report attesting to the repairs and proper operation of the Auxiliary Boiler.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 10 April 2007 Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting System while transiting into the Port of Brunswick, Ga.
Condition: Unknown
Due 10 April 2007
Resolved 10 April 2007
Resolution: Issued LOW
Documentation
Issued 25 June 1999 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. PROVIDE COMPLETE OIL TRANSFER PROCEDURES PRIOR TO BUNKERING OR TRANSFERING OIL IN THE U.S. WATERS AND PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Construction/Loadline
Issued 25 June 1999 Resolved
FRACTURE ON AFT CORNERS OF EMERGENCY GENERATOR HOUSE AT DECK. FRACTURES ARECOVERED WITH A BLACK PUTTY TO PREVENT WATER INTRUSION. REPAIR/RENEW TO SATISFACTION OF CLASS. PROVIDE CLASS REPORT PRIOR TO RETURN TO U.S. OR 25 JUL 99.
Condition: Unknown
Due 25 July 1999
Resolved 27 October 2002
Resolution: DEFICIENCY WAS CORRECTED PRIOR TO ENTERING THE PORT. INSPECTION SHOWED DEFFICIENCY WAS CORRECT AND WAS CLEARED BY THE CLASS.
Engineering
Issued 25 June 1999 Resolved
OILY WATER SEPERATOR HAS TIME DELAY BEFORE UNIT REACTS TO 15PPM. REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO USING OWS AND PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 26 June 1999
Resolved 27 October 2002
Resolution: DEFICIENCY WAS CLEARED PRIOR TO ENTERING THE PORT. INSPECTION DETERMINED THAT THE CORECTION WAS MADE AND THE TIME DELAY WAS FIXED. THE DEFICIENCY WAS CLEARED IN ACCORDANCE TO CLASS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.