SPIRIT OF THE WATER

SPIRIT OF THE WATER is a 1999 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 1999, most recently in July 2025, along with 34 deficiencies, 2 operational controls and 1 casualty investigation in 2018.

Records from 1999 to 2025. Most recent: inspection, 2 July 2025.

Built
1999
Last inspected
2 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA6208
498128
Flag
UNITED STATES
—
Maury page id
psix-498128

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (1999–2025)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 169 / net 61
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREDWING, MN
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Net Ton
61 - Convention (Subpart B), Net Ton
76 - Regulatory (Subpart C or D), Gross Ton
169 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

2 July 2025 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8173421
29 October 2024 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8025709
20 June 2024 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7934069
22 May 2024 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7921560
16 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7890035
1 December 2023 Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7833161
20 June 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7719208
21 June 2022 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7453804
28 March 2022 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7419888
6 July 2021 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7246584
23 June 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7234451
8 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7000501
4 June 2019 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6704489
15 April 2019 Examination of Repairs
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6663114
6 November 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6575323
21 October 2018 Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6570524
26 June 2018 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6456843
26 April 2017 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6104440
2 May 2016 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5867464
1 May 2012 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4299238
17 November 2010 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3892991
8 April 2009 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3448567
9 May 2008 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3202070
20 June 2007 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2959875
6 June 2007 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2953058
19 June 2006 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2686954
20 July 2005 Periodic Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2435634
24 August 2004 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2174951
24 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1977935
23 September 2003 Annual Inspection · Deficiency Check
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1912573
25 June 2002 COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1635805
5 September 2001 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1379552
21 August 2001 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 31255
20 June 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1393740
20 September 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 822074
27 April 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1459596
4 July 1999 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 14223
1 July 1999 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1372690

Deficiency record · 34

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 December 2023 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural examination at least once every five years. Vessel did not complete dry dock examination and ISE prior to 30NOV2023. Vessel is not permitted to carry passengers until credit dry dock is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Credit Drydock completed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Attached electrical box cover on 2nd deck storage locker, and properly cap or remove electrical cables: STBD AFT corner in the Engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 27 June 2023
Resolution: Recieved photos of cover 12 volt junction box cover installed, and electric cable removed in E/R
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2023 Resolved
Each ring life buoy on a vessel must: be approved in sub-chapter Q of this chapter... Port fwd life ring line was deteriorated. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 14 August 2023
Resolution: Life ring replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2022 Resolved
#2 space bilge alarm could be tested but only manually; the float appears to be broken
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2022
Resolution: New float installed and tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2022 Resolved
Engine room CO2 bottles not secured properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: bottles have been secured
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2022 Resolved
Crew unable to perform routine shipboard functions
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 July 2021 Resolved
Inadequate pressure (20 psi)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: Diver found zebra mussels and debris in the water intake. Cleared out and pressure was sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 July 2021 Resolved
flares expired in 2019
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2021
Resolution: Flares have been delivered.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 July 2021 Resolved
No light list found onboard
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2021
Resolution: Printed out local area light list.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 July 2020 Resolved
high bilge alarms were sounding on the bridge for the tank compartment and rudder compartment. Small amount of water located in the bilge. Dewater and test alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2020
Resolution: crew dewatered spaces and re-tested alarms; all sat.
Stability › Watertight Integrity › General
Issued 8 May 2009 Resolved
Install metallic shutoff valves on all non-metallic thru hull openings 46 CFR 182.720
Action required: 705 - Other - as specified
Due 13 April 2011
Resolved 17 November 2010
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 April 2009 Resolved
Obtain and Post Emrgency Instruction List at Op Station - IAW 46 CFR 185.510
Action required: 705 - Other - as specified
Due 6 June 2009
Resolved 4 June 2009
Resolution: Master post the emergency instruction list at the op station
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2009 Resolved
Renew 2 fuel hoses on bow thruster that are not CG Approved Hoses IAW 46 CFR 182.720
Action required: 705 - Other - as specified
Due 6 June 2009
Resolved 4 June 2009
Resolution: Type A1 hoses were installed, Master stated the system does not get above 5 psi
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 April 2009 Resolved
Engine Room CO2 Botles are not installed per Kiddie Manual - Bottles need to be up Right Per Marks on Bottle 46 CFR 181.410
Action required: 705 - Other - as specified
Due 6 June 2009
Resolved 4 May 2016
Resolution: Nardian (Company Hired by Master) correct the bottles to be up right, two of the bottles were not correct to valve heads and syphon tube.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 April 2009 Resolved
Remove and install metalic approved flexable hose on both the fire and blige pump suction and discharge IAW 46 CFR 182.710. Current hoses are not approved
Action required: 705 - Other - as specified
Due 6 June 2009
Resolved 4 June 2009
Resolution: Items completed, new metalic hoses installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 April 2009 Resolved
Provide an acceptable means to retrive a man from the water IAW 46 CFr 185.520
Action required: 705 - Other - as specified
Due 6 June 2009
Resolved 4 June 2009
Resolution: Item pruchased waiting to arrive to vessel.
Engineering › Bilge Water Management System › Strainer
Issued 9 May 2008 Resolved
Replace bilge strainer in stearing gear compartment old one is rusted through on one side.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 23 May 2008
Resolution: Operator sent photo of new strainer in place.
Stability › Incline Test › General
Issued 9 May 2008 Resolved
In accordance with paragraph 8 of your stability letter, HI-9902017, dated 22 June 1999, and the addition of 3744 lbs of ballast your stability letter is invalidated. The ballast must be removed or the vessel must be given a stability test IAW 178.310. Until one of these options is complete your number of passengers is reduced to 125. Contact this office at [phone withheld] on your course of action
Action required: 705 - Other - as specified
Resolved 30 May 2008
Resolution: Vessel Representative removed ballast from space.
Lifesaving › Hand Flares › Expired
Issued 6 June 2007 Resolved
Provide distress signaling devices IAW 46 CFR 180.86. All Current devices are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2007
Resolution: Replaced expired signal flares, verified on 6/7/07
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 June 2007 Resolved
No service report available for fixed fire fighting system in engine room or bow thruster room. To the satisfaction of a Coast Guard Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2007
Resolution: Servicing report provided to [name withheld] on 6/7/2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 June 2007 Resolved
Conduct drills underway, unable to at this time due to no properly licensed captain on board.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 20 June 2007
Resolution: Conducted two man-overboard drills and two fire drills. Drills were satisfactory.
Documentation › Logs/Records › Logbook (official)
Issued 6 June 2007 Resolved
No training logbook on board. Provide logbook.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 20 June 2007
Resolution: Training Logbook provided, recent entries appropriately logged.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2007 Resolved
Provide evidence of compliance with part 16.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 20 June 2007
Resolution: Provided evidence of compliance with part 16. Satisfactory drug and alcohol testing program now in place.
Engineering › Bilge Water Management System › Interface Detector
Issued 20 July 2005 Resolved
Properly secure high level bilge alarm located in the bow thruster space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 20 July 2005 Resolved
Properly secure loose light cover located in the forward storage compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 July 2005 Resolved
Properly clean battery terminals on ships generator and remove liquid from battery box.
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 July 2005 Resolved
Properly seal electrical junction box located in the galley starboard side forward of the sink.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 20 July 2005 Resolved
Properly install double nuts on throttle linkage for both main engines.
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 20 July 2005 Resolved
Properly repair coolant leak located on the starboard main engine cooler at the inboard side of hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 20 July 2005 Resolved
Properly install device designed for use as crankcase breather to collect engine blow-by.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2005
Resolved 30 July 2005
Accommodation/Occupational Safety › Potable Water System
Issued 23 September 2003 Resolved
Prove proper operation of potable water pump, lavatories, and wash basins.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2003
Resolution: Vessel operator installed new pump, inspected found all satisfactory.
Navigation › Collision/Grounding Avoidance
Issued 25 June 2002 Resolved
Replace exisiting bell with a 300 mm according to navruls LEGACY COMPONENT DESC: Danger Messages
Condition: Improper Installation
Due 30 July 2002
Resolved 24 September 2003
Resolution: New Bell installed
Electrical
Issued 20 September 2000 Resolved
DO NOT ENERGIZE, OR USE THE INSTALLED ROPE LIGHTING UNTIL FURTHER NOTICE
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Documentation
Issued 1 July 1999 Resolved
PROVIDE PROOF THAT THE CERTIFICATE OF DOCUMENTATION IS ENDORSED WITH COASTWISE SERVICE.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999

Casualty record · 1

21 October 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6570524
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.