MAURY USCG vessel records
← All vessels

FIRST LIGHT

Built
1978
Last inspected
10 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDR2928
Flag
UNITED STATES
Maury page id
psix-49814

Documentation record

Registered dimensions (L × B × D)38.1 ft × 13.6 ft × 4.5 ft
Registered tonnagegross 23 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRUNO AND STILLMAN INC · NEWINGTON, NH, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHERRYFIELD, ME
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 8 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

10 June 2026 COI Inspection · Vessel Attendance · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8397470
1 July 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8172015
19 July 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7962034
18 April 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7898119
13 April 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7670981
30 March 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7660314
3 February 2022 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7390418
18 November 2021 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7356009
20 May 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7202919
15 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7175517
11 June 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6933008
30 May 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6698334
4 April 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6655430
5 April 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6386266
11 May 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6144927
3 February 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6082581
5 April 2016 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5860040

Deficiency record · 8

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The vessel's safety cert was past its due date. 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 July 2024
Resolution: New FCC Safety Cert was attained.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 February 2022 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. Excessive oil found below the engine compartment. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 3 March 2022
Resolution: Oil accumulation cleaned out of bilges
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shutoff valve was not accessible from outside the space. 46 CFR 182.455
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 3 March 2022
Resolution: Vessel opened up deck at Fuel shutoff
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 April 2021 Resolved
The owner, charter, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to the emergency instructions listed on the emergency instruction placard containing the actions to be taken in the event of fire, heavy weather, abandons ship, and man overboard conditions. Records only indicated abandon ship / man overboard drills are conducted. 46 CFR 185.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 22 February 2022
Resolution: Drills conducted during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical hazards observed: a. Starboard engine compartment light fixture has deadend wires not properly connected. b. Screw connectors used for spliced wires to oil change pump; port side engine room. c. Face plate missing from electrical outlet in accommodation space; starboard bench outlet. 46 CFR 183.210(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 29 April 2021
Resolution: Attended vessel and visually inspected corrected electrical items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2021 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated. Exhaust elbow leading to the point of cooling water injection was not water-jacketed or effectively insulated. 46 CFR 182.20-15(a) 46 CFR 182.15-15(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 29 April 2021
Resolution: Attended vessel and visualy inspected installed lagging over dry section of exhaust piping.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 March 2017 Resolved
Attach waterlight lanyard to body of lifering with corrosion resistant clip. 46 CFR 180.70(d)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 2 March 2017
Resolution: O/O properly attached waterlight to life ring buoy with corrosion-resistant clip.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 March 2017 Resolved
Replace waterlight batteries in all waterlights with batteries recommended by manufacturer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 2 March 2017
Resolution: O/O purchased proper batteries and replaced in all waterlights.

Recorded names · 1

CAPT. JASON II (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record