04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 April 2024
No resolution recorded
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual indicator for engine space not working at time of inspection. Must correct to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2024
No resolution recorded
All flex hoses on the main engines must be double clamped to the satisfaction of the USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 April 2024
No resolution recorded
All flex hoses for vital systems must be double clamped. Flex supply fuel hoses at main cut-off valves must be double clamped to the satisfaction of the USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024
Resolved
Rigid plastic piping (PVC) for vital systems must meet the requirements of IMO Resolution A.753(18) and MSC.313(88). Must show that plastic piping sections for raw water cooling feeds for all engines meet the resolution requirements or must remove these sections to the satisfaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 23 May 2024
Resolution: PVC piping traced to bait tanks. No def
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 April 2024
Resolved
All escape hatch signs must be marked with clearly legible letters. Sign on galley side is wasted and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 23 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 April 2024
Resolved
Remote fuel shut-off valves must be marked with clearly legible letters. Signs at the pull handles for fuel shut-offs are worn and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 23 May 2024
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 18 April 2024
No resolution recorded
A vessel must comply with the applicable requirements for any radio equipment as required by 47 CFR 80. Digital Selective Calling (DSC) did not indicate vessel's current Lat and Lon on VHF radio. Must correct to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 March 2023
Resolved
Vessel's integrated fire detection system is inoperable. Repair fire detection system and conduct satisfactory test in presence of USCG marine inspector. Cite: 46 CFR 181.405(c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: Witnessed satisfactory test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 March 2023
Resolved
Vessel's roving watch alarm system is inoperable. Repair roving watch alarm system and conduct satisfactory test in presence of USCG marine inspector. Cite: 46 CFR 185.410(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: Witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 March 2023
Resolved
Vessel's ring life buoy is excessively worn. Replace ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2023
Resolved 24 April 2023
Resolution: Received picture of new ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 March 2023
Resolved
Window on the starboard quarter of the wheelhouse is broken. Repair broken window. Cite: 46 CFR 177.1020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2023
Resolved 24 April 2023
Resolution: Received picture of repaired window.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 13 March 2023
Resolved
Vessel does not have a garbage management plan. Draft a garbage management plan and post in the galley/salon where it can be readily seen by passengers and crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2023
Resolved 24 April 2023
Resolution: Received picture of posted garbage management plan.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 March 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible, U.S. Coast Pilot or similar publication, Coast Guard Light List, Tide tables, and Current tables. Vessel does not have required charts and nav pubs. Acquire charts and nav pubs for vessel. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2023
Resolved 24 April 2023
Resolution: Received picture of new nav pubs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 February 2023
Resolved
Vessel is not adequately equipped to rescue an unconscious person from the water. Develop an adequate means for recovery of an unconscious man-overboard and demonstrate in the presence of a USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2023
Resolution: Vessel acquired a sturdy aluminum ladder that reaches the water.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 July 2022
Resolved
Vessel experienced a break to the starboard shaft in vicinity of the gear box to the main engine while transiting outbound of San Diego Bay. Prior to carrying passengers, the vessel operator must: conduct a full damage assessment of all shaft components (struts, cutless bearings, propeller) replace starboard shaft in kind, replace any damage shaft components and have a USCG Marine Inspector verify installation of new shaft and condition of all shaft components.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2022
Resolution: Shaft replaced, all STBD motor mounts replaced, shaft seal replaced; dock trials tested satisfactory. [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 February 2022
Resolved
A pre engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2022
Resolved 25 February 2022
Resolution: Corrected; Op tested; ALL SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2022
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Two engine room water pumps not secured. Fasten pumps to prevent movement.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 25 February 2022
Resolution: Refastened to deck mount; Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 February 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Provide permanent separation to prevent child life-jackets from being mistaken for adult.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 25 February 2022
Resolution: Properly stowed and marked.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 February 2022
Resolved
Emergency escape placard at main deck salon; broken. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 19 April 2022
Resolution: Installed proper placard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 February 2022
Resolved
Original COI not available onboard / available for inspection. Provide original for Annual Inspection endorsement and keep onboard
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 25 April 2022
Resolution: Original COI found and included in vesssl files.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 February 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2022
Resolution: Two crewmembers showed proof of FCC License
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 February 2022
Resolved
FCC Safety Radiotelephony Certificate not onboard / available for inspection. Provide valid certificate from FCC technician.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 February 2022
Resolution: Operator provided photo.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 February 2022
Resolved
All Three 5 gallon fire buckets are to be 2.5 gallon capacity. Reduce drilled holes to the appropriate 2.5 gallon mark.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 25 April 2022
Resolution: Bucket replaced with proper 2.5 galllon fill marks.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 February 2021
Resolved
Vessels charts and publications were more than three years old. Provide up to date charts and publications (as required by 46 CFR 184.420) for the vessel's intended voyages.
Action required: 10 - Deficiency Rectified
Due 8 March 2021
Resolved 22 February 2021
Resolution: Proof of updated charts/pubs submitted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. (Note: Show over-current protection on generator switchboard or on generator)
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 20 August 2020
Resolution: AC 1-line verification completed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Due 13 October 2019
Resolved 13 October 2019
Resolution: Educated operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Correct the following: 1) Properly install vessel ship/shore switch. 2) Install circuit breaker blanks in wheelhouse panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 18 November 2019
Resolution: Witnessed corrections.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 October 2019
Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the underside. Mark emergency escape hatch with proper marking on both sides. In addition, add "PUSH" with direction arrow forward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 18 November 2019
Resolution: Witnessed corrections.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 13 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Vessel did not have lighting at the aft emergency exit. Provide emergency lighting at this emergency exit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 18 November 2019
Resolution: Witnessed corrections.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 October 2019
Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation form galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 18 November 2019
Resolution: Witnessed corrections. Discussed with operator that as per local CID policy, hood shall be cleaned at least quarterly or less as needed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2019
Resolved
Properly mount galley and accommodation fire extinguishers in brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 28 May 2019
Resolution: Extinguishers mounted properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2019
Resolved
Provide 60 feet of line for the life ring.
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 April 2019
Resolution: 60 feet of line provide the same day.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2019
Resolved
Renew retro-tape on life ring.
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 April 2019
Resolution: Retro-tape renewed the same day.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 April 2019
Resolved
Make two unused bulkhead penetrations stbd side in the aft E/R bulkhead vapor tight.
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 April 2019
Resolution: Penetrations made vapor tight the same day.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 23 April 2019
Resolved
Provide a mic for the HF radio.
Action required: 10 - Deficiency Rectified
Due 23 May 2019
Resolved 23 April 2019
Resolution: Mic provided the same day.
Documentation › Certificates/Documents › Stability Letter
Issued 4 May 2018
Resolved
Post stability letter on the bridge.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Letter posted.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 May 2018
Resolved
Renew alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Swabs renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 May 2018
Resolved
Renew stern light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Light replaced.
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 May 2018
Resolved
Post life jacket donning placard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Placard posted.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 May 2018
Resolved
Connect GPS to VHF DSC radio.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: GPS connected.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 May 2018
Resolved
Renew smoke detectors in berthing area.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Detectors renewed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 May 2018
Resolved
Properly mark fuel shut off valves.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Valves marked.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 May 2018
Resolved
Post emergency broadcast placard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 May 2018
Resolution: Placard posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 April 2017
Resolved
Prior to operating with passengers, provide proof of servicing fixed f/f system & portable extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 27 April 2017
Resolved
Prior to carrying passengers below deck, provide RV-type (UL-217) smoke detector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 28 April 2017
Electrical › Electrical Distribution System (service) › Switch
Issued 27 April 2017
Resolved
Replace handle on shore power switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 26 June 2017
Communications › Radio Communications › EPIRB
Issued 28 April 2016
Resolved
Replace EPIRB hydro release NLT 31MAY16
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 28 April 2016
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 28 April 2016
Resolved
Vessel is restricted to 20 NM pending repair or replacement of SSB radio.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 6 June 2016
Resolution: New SSB installed and tested
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 April 2016
Resolved
Remove FireBoy auto shutdown/override unit from E/R and install in dry location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 26 May 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 April 2016
Resolved
Attach electric waterlight to ring buoy with 6-ft detachable line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 28 April 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 April 2016
Resolved
Post drug abuse hotline phone number.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 28 April 2016
Documentation › Markings/Placards › Warning Signs
Issued 28 April 2016
Resolved
Label exterior of 120V electrical panel in E/R: "120V BREAKERS"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 28 April 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 April 2016
Resolved
Complete COI renewal exam; vessel overdue as of March 31, 2016.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2016
Resolved 28 April 2016