BROOKS HOOKS

BROOKS HOOKS is a 1999 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1999, most recently in July 2026, along with 94 deficiencies.

Records from 1999 to 2026. Most recent: inspection, 30 July 2026.

Built
1999
Last inspected
30 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI7744
498215
Flag
UNITED STATES
367731780 (licence lapsed)
Maury page id
psix-498215

Inspections, by type

Years with a record 23 calendar years (1999–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS · CRISFIELD, MD, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTILGHMAN, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 22 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7744MMSI 367731780 · expired · compulsorily equipped · granted 3 May 2016, cancelled 27 June 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

30 July 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8455089
27 August 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8219141
1 May 2025 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8127359
15 January 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8063843
20 August 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7985431
25 July 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7966777
24 August 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7776515
14 August 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7768014
1 August 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7757954
13 September 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7558575
2 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7275021
13 July 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7255005
23 September 2019 Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818576
17 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6817296
10 July 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6744500
3 April 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6400595
9 February 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6352459
25 July 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6264147
5 April 2017 Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6127538
3 June 2016 COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5895990
9 February 2012 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4245047
3 August 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4104243
10 January 2011 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3924180
2 September 2010 Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3846913
27 January 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3692580
26 March 2009 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3442843
11 September 2008 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3323407
23 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3136560
21 September 2006 Plan Review "T" Boat · Hull Examination · Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2783157
9 January 2006 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2563342
11 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2307879
3 September 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2192151
30 January 2004 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1997840
27 January 2003 Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1742202
30 July 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1654225
1 November 2001 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1376725
21 August 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1382045
7 July 1999 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1093436
7 July 1999 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1365282

Deficiency record · 94

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2024 Resolved
07126 - At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. There was excessive accumulation of oil in the engine compartment. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 20 August 2024
Resolution: Received photographic evidence the bilge was cleaned of excess oil.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 July 2024 Resolved
11118 - An adult life jacket must be provided for each person carried on board a vessel. The vessel is required to carry 40 adult life jackets and there were only 34 on board. The passenger count is reduced to 32 until all required life jackets are on board the vessel. 46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 20 August 2024
Resolution: Received photographic evidence the 6 missing life jackets were placed on baord.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 August 2023 Resolved
13104: Individual power pumps used for separate spacesare to be controlled from a central control point and must have a means at control point to indicate operation. Visual indicator for aft hold did not illuminate when tested. 46 CFR 182.520 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Witnessed satisfactory test of the aft compartment bilge indicator.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 August 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel Owner/Operator failed to complete the required annual inspection by the due date of August 1, 2023. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2024
Resolution: An annual inspection was completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found rot on chine beam in space aft of engine compartment STBD side. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found rot on plywood decking plating IVO Space aft of engine compartment STBD side FWD. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found wood rot on hull in space aft of engine compartment Port side. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found de-lamination of FRP in Lazarette. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found crack in gel coating on STBD side aft hull below rub rail. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2023 Resolved
46CFR176.670 - The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. MI found STBD cutlass bearing wasted. Replace cutlass bearing to the satisfaction of [name withheld] to yard availability, extended requirment until 16SEP2023
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 7 September 2023
Resolution: Received photo evidence for cutlass bearing replacement
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 September 2022 Resolved
A buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. The vessel is required to have a life float in accordance with 46 CFR 180.200(c) Table and currently has a buoyant apparatus on board. 46 CFR 180.200(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2024
Resolution: The vessel now has a 12 person life float on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2021 Resolved
A submersible electric bilge pump may be used provided that a positive shutoff valve is installed at the hull penetration. Vessel was missing shutoff valve in lazarette and engine room valve was severely corroded. 46 CFR 182.520(e)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 8 September 2021
Resolution: O/O replaced valve
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 August 2021 Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter. The vessel had expired waterlight batteries in life float. 46 CFR 180.70(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 8 September 2021
Resolution: O/O replaced waterlight batteries.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Vessel has break in plywood located in starboard bow approx. 30" from the stem. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: O/O repaired as original.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Plywood deck around fuel oil tank was wasted. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: O/O replaced plywood deck.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Crack in gel coat on starboard side approx. 10' from the stem and 2' below gunnel. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Crack in gel coat has been repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. De lamination in lazarette, inboard and forward of port side rudder. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Delamination has been repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Port ventilation shutoff seperated from deck. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Port ventilation shutoff has been reglassed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Transom rot in both aft corners. Submit repair proposal for repairs. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Transom rot has been abated and epoxied over.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 April 2018 Resolved
Vessel's fwd and aft fuel tanks were not properly grounded. Ensure fuel tanks are properly grounded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Fuel tanks were properly grounded.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 April 2018 Resolved
Vessel's fuel fill on aft tank not properly grounded . Ensure fill is proplery grounded.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Fuel tank fills were propelry grounded.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 April 2018 Resolved
Vessel's port fuel filter leaking diesel fuel. Ensure filter is not leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Port filter was not observed leaking during operational test.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2018 Resolved
Vessel's electrical wiring was not properly supported throughout vessel. Ensure wires are properly supported.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Wires were properly supported.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2018 Resolved
Vessel's port/stbd water washdown pump's electrical wiring not properly connected. Enaure wires are connected using proper connectors.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Washdown pumps wiring was properly connected/installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2018 Resolved
E;ectrical conductor found with exposed wiring in wash down cmpt. Remove, properly connect wiring.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Exposed wire was removed from vessel.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 April 2018 Resolved
Vessel's stbd shaft bearing leaking water excessively. Ensure shaft is not leaking water excessively.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Bearing was tightened and shaft was not leaking water during operational tests.
Engineering › Bilge Water Management System › Pump
Issued 3 April 2018 Resolved
Vessel's forward bilge pump not operating properly. Ensure proper operation of pump.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Bilge pump was tested and was found to be operating properly.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 April 2018 Resolved
Excessive oil found in bilges. Remove excessive oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Owner removed excessive oil from bilges.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 3 April 2018 Resolved
Fire boy fixed extinguishing system electrical connection not properly connected. Connection is worn/improper. Ensure proper connection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Fireboy connection was repaired and override was retested with satisfactory results.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 April 2018 Resolved
Portable fire extinguishers not in proper bracket suitable for size of extinguisher. Provide suitable bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Port. extinguisher had proper brackets.
Lifesaving › Lifebuoys › Serviceable
Issued 3 April 2018 Resolved
Vessel's life ring torn and color is faded. Replace with proper life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Vessel replaced life ring with non worn proper type.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2018 Resolved
Vessel's first aid kit has expired contents. Ensure contents have not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Owner replaced contents with non-expired type.
Documentation › Markings/Placards › Lifejacket Placard
Issued 3 April 2018 Resolved
Vessel's life jacket instruction placard did not have instructions for proper type I PFD's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Owner placed proper life jacket donning placard onboard.
Lifesaving › Lifefloat › Netting
Issued 28 September 2017 Resolved
Lifefloat netting needs to get replaced.
Condition: Improper/Lack of Maintenance
Due 5 October 2017
Resolved 3 April 2018
Resolution: Owner repaired life float with proper repair kit and replaced netting.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2017 Resolved
Provide UL approved type auto bilge pump where non UL approved pumps are used.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner installed proper bilge pumps.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 25 July 2017 Resolved
Onboard pre-engineered fire fighting system for engine cmpt rated for 700 CF not 1000 CF as listed on the COI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: ER measured for cubic ft and determined that it is 600 CF. Not 1000 cubic feet that was previously listed on COI. Current fire boy system is sat.
Lifesaving › Lifefloat › Float-free Link
Issued 25 July 2017 Resolved
Weak link for life float assembly missing capacity tag. Provide tag or new weak link assembly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Lifefloat has appropriate weak link.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 25 July 2017 Resolved
Vessel stbd shaft leaking water excessively. Ensure shaft is not leaking water excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 25 July 2017
Resolution: Vessel owner adjusted shaft packing.
Engineering › Lubricating Oil Storage/Transfer System › Filter/Strainer
Issued 25 July 2017 Resolved
Port engine oil filters leaking oil excessivley. Ensure oil is not leaking excessively.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Operated engine and did not observe any oil leaking from filter.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 July 2017 Resolved
Provide current copy of Certificate of Documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner provided current COD.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 July 2017 Resolved
Provide current copy of FCC Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner provided current certificate.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 July 2017 Resolved
Emergency instructions were not onboard vessel. Provide current copy of emergency instructions and post onboard vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner provided updated emergency instructions.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 July 2017 Resolved
PFD's have tears and require maintenance. Ensure PFD's are repaired with proper approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 3 April 2018
Resolution: Owner repaired or replaced worn PFD's.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 April 2017 Resolved
Replace fuel tank flexible line withe approved hose IAW 46 CFR 182.450(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 24 May 2017
Resolution: Owner purchased proper flexible vent hose.
Construction/Loadline › Hull › Stringer
Issued 5 April 2017 Resolved
Bilge stringers IWO of steering compt. decayed/rotted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2017
Resolved 25 April 2017
Resolution: Owner removed decayed stringers and installed new stringers IVO steering cmpt.
Construction/Loadline › Hull › Transverse Frame
Issued 5 April 2017 Resolved
Transverse deck beam IWO steering cmpt rotted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2017
Resolved 25 April 2017
Resolution: Owner removed decayed transverse beam and installed new beam.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2017 Resolved
Port side side shell/transom butt joint rotted IWO of steering cmpt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner installed new plywood and FRP on side shell.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2017 Resolved
Stbd side sideshell/transom butt joint rotted IWO steering cmpt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner installed new plywood insert and FRP.
Construction/Loadline › Structures › Deck Plating
Issued 5 April 2017 Resolved
Port side gunwale rotted crop/renew as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner removed damaged gunwale and glassed over with new FRP.
Construction/Loadline › Hull › Side Shell
Issued 5 April 2017 Resolved
Port side hull damaged excessively repair/renew
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner ground down damaged portion and glassed over with new FRP.
Construction/Loadline › Hull › Transverse Frame
Issued 5 April 2017 Resolved
Pot side transverse deck beam and frame rotted IWO of fuel cmpt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 24 May 2017
Resolution: Owner removed rotted beam and installed new beam.
Construction/Loadline › Hull › Keel Plate
Issued 5 April 2017 Resolved
Stbd side keel gel coat damaged repair/renew
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Observed photograph of repaired keel/skeg area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2017 Resolved
Remove/properly dead end exposed electrical wiring IWO of engine cmpt.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 25 July 2017
Resolution: Owner removed electrical wires from E/R.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 April 2017 Resolved
Replace fuel tank fill line with approved hoses IAW 46 CFR 182.445(g).
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 24 May 2017
Resolution: Owner purchased proper flexible fuel fill hose.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 January 2011 Resolved
Repair wires at Stbd battery for anchor windless. Reconnect to Fuse.
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 5 April 2011
Resolution: Attended vessel and cleared above deficiency.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 10 January 2011 Resolved
Prove proper operation of engine compartment ventilation shutdowns.
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 5 April 2011
Resolution: Attended vessel and cleared above deficiency.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 10 January 2011 Resolved
Stbd shaft coupling leaking excessively. Repair and prove proper operation.
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 5 April 2011
Resolution: Attended vessel and cleared above deficiency.
Construction/Loadline › Hull › Keel
Issued 2 September 2010 Resolved
Keel aft directly below the transom is cracked & damaged. Remove damage to good wood and make repairs to the satisfacion of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2010
Resolution: Approximately 4'' of keel directly beneath the transom was cropped and renewed to the satisfaction of the CG Marine Inspector.
Construction/Loadline › Hull › Side Shell
Issued 2 September 2010 Resolved
Fiberglass cracked port side amiship on the chine. Remove fiberglass to exam integrity of underlying wood and submit repair proposal to CG Marine Inspector for review.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2010
Resolution: Cracked fiberglass on the port side of vessel amidship was sanded down and reglassed to the satisfaction of the CG Marine Inspector.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 September 2010 Resolved
Starboard strut cracked where it connects to hull. Repair to the satisfaction of the CG Marine Inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2010
Resolution: Starboard strut re-welded to the brace to the satisfaction of the CG Marine Inspector.
Construction/Loadline › Structures › Deck Plating
Issued 2 September 2010 Resolved
Flooring behind port & starboard main engines showing signs of rot. Remove the rotted sections to good wood and make repairs to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2010
Resolution: Approximately 6'' of flooring behind both engine compartments cropped and renewed to good wood and replaced with marine grade plywood to the satisfaction of the CG Marine Inspedtor.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 January 2010 Resolved
Pre-engineered fixed fire extinguishing system (Fire Boy) wouldn't shut off the main engines when the wiring was disconnected from the bottle. Service/replace Fire Boy so it shuts down the mains when disconnected (simulation of a discharge).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: Service rep repaired the wiring on the Fire Boy which was satisfactorily tested on this date.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 January 2010 Resolved
Missing one adult, type I life jacket. Replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: Additional life jacket purchased.
Lifesaving › Lifefloat › Markings
Issued 27 January 2010 Resolved
Person capacity and reflective tape missing from Life Float. Re-label and replace reflective tape as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: Person capacity re-stenciled on the life float. Reflective tape replaced on the life float as directed.
Lifesaving › Lifefloat › Float-free Link
Issued 27 January 2010 Resolved
Weak link on Life Float to small - replace with an appropriate sized weak link.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: 22 person (adequate size) weak link purchased and installed on the vessel.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 January 2010 Resolved
Emergency Fuel shutoffs at both port & starboard fuel tanks not labeled (worn off). Re-label as appropriate.
Condition: Improper/Lack of Maintenance
Due 27 February 2010
Resolved 29 March 2010
Resolution: Emergency fuel shutoffs relabeled.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 March 2009 Resolved
Alcohol tests kit on-board vessel expired. Replace as new prior to carrying to passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Resolution: Alcohol test kits purchased and maintained on board.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 March 2009 Resolved
Bilge pump alarm in forward compartment inoperable. Replace and show proof of an operable bilge pump alarm in forward compartment prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2009
Resolution: Loose wire was located on bilge pump alarm. Wire re-connected and alram functional to the satisfaction of the CG Marine Inspector.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 January 2008 Resolved
03 automatic bilge pump lights at console are non-functional. Vessel owner informed that he must repair in-kind w/ CG approved automatic bilge pump lights that correspond with appropriate bilge pumps. The forward compartment needs a UL listed bilge pump and high water level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2008
Resolved 17 April 2008
Resolution: Conducted deficiency check on vessel to determine whether electric bilge pump lights were currently in compliance w/ CG regs. Vessel''s deficiencies were cleared due to proper activation of lights at the console.
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 September 2006 Resolved
Replace two (2) longitudinal frames under cabin that are rotten.
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 19 April 2007
Resolution: completed.
Construction/Loadline › Hull › Transverse Frame
Issued 21 September 2006 Resolved
Remove and replace frame undr fuel tank.
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 19 April 2007
Resolution: completed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 January 2006 Resolved
Cylinder for system could not be serviced by visiting fire extinguisher contractor. Replace cylinder in kind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2006
Resolution: Owner replaced Fire Boy bottle.
Construction/Loadline › Hull › Stringer
Issued 11 March 2005 Resolved
Replace port bilge stringer in forward fuel tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 31 March 2005
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 March 2005 Resolved
Renew retro-reflective tape, label number of passengers, and re-attach waterlight to body of lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 31 March 2005
Engineering › Bilge Water Management System › Valve
Issued 11 March 2005 Resolved
Replace handle on shutoff valve for aft fuel compartment bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 31 March 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 March 2005 Resolved
Re-label emergency shut-off for aft fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 31 March 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2005 Resolved
Owner failed to schedule annual inspection within 90-day window.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2005
Resolved 11 March 2005
Communications › Alarms/Indicators
Issued 30 January 2004 Resolved
Demonstrate operation of high water alarm in fuel tank compartment. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 23 March 2004
Engineering › Fuel Oil Service System
Issued 29 January 2004 Resolved
Provide fuel shut off valve on engine. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 23 March 2004
Engineering
Issued 29 January 2004 Resolved
Provide valve on forward bilge pump overboard discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 23 March 2004
Documentation › Certificates/Documents
Issued 29 January 2004 Resolved
Provide marine radio operator license.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 23 March 2004
Documentation › Certificates/Documents › FCC SSL
Issued 29 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 8 June 2004
Lifesaving › Lifebuoys
Issued 29 January 2004 Resolved
Provide non corrosive clip on life ring buoy waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 30 March 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 January 2004 Resolved
Provide gasket on engine boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 30 March 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 2 June 2003 Resolved
Repair automatic shutdown for port engine on fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2003
Resolved 5 June 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 January 2003 Resolved
Repair alarm on fixed fire-extinguishing system LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2003
Resolved 5 June 2003
Engineering › Shafting/Propeller Arrangements
Issued 27 January 2003 Resolved
Tighten shaft seal on port MDE LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Due 27 February 2003
Resolved 5 June 2003
Engineering › Bilge Water Management System
Issued 27 January 2003 Resolved
Label high water alarms at operating station LEGACY COMPONENT DESC: Interface Detector
Due 27 February 2003
Resolved 5 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 27 January 2003 Resolved
Install machinery guards on MDE's LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 27 February 2003
Resolved 5 June 2003
Lifesaving › Buoyant Apparatus
Issued 27 January 2003 Resolved
Label lifefloat paddles w/ vessel name
Due 27 February 2003
Resolved 5 June 2003
Lifesaving › Buoyant Apparatus
Issued 27 January 2003 Resolved
Provide capacity info for float-free link
Due 27 February 2003
Resolved 5 June 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 30 July 2002 Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2002
Resolved 31 July 2002
Fire Fighting
Issued 30 July 2002 Resolved
INSTALL CAP ON END OF CONDUITS ON PORT/STBD SIDE OF FWD ENGINE COMPARTMENT BLKHEAD
Due 15 August 2002
Resolved 15 August 2002
Lifesaving
Issued 21 August 2000 Resolved
REPLACE EXISTING BA WITH APPROVED LIFEFLOAT.
Condition: Unknown
Due 21 September 2000
Resolved 14 January 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.