BROOKS HOOKS is a 1999 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in July 2026, along with 54 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 30 July 2026.

Built
1999
Last inspected
30 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 July 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7744
498215
Flag
UNITED STATES
Maury page id
psix-498215

Documentation record

Registered dimensions (L × B × D)48.0 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS · CRISFIELD, MD, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTILGHMAN, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 22 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 54 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

30 July 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8455089
27 August 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8219141
1 May 2025 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8127359
15 January 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8063843
20 August 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7985431
25 July 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7966777
24 August 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7776515
14 August 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7768014
1 August 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7757954
13 September 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7558575
2 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7275021
13 July 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7255005
23 September 2019 Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818576
17 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6817296
10 July 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6744500
3 April 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6400595
9 February 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6352459
25 July 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6264147
5 April 2017 Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6127538
3 June 2016 COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5895990

Deficiency record · 54

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2024 Resolved
07126 - At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. There was excessive accumulation of oil in the engine compartment. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 20 August 2024
Resolution: Received photographic evidence the bilge was cleaned of excess oil.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 July 2024 Resolved
11118 - An adult life jacket must be provided for each person carried on board a vessel. The vessel is required to carry 40 adult life jackets and there were only 34 on board. The passenger count is reduced to 32 until all required life jackets are on board the vessel. 46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 20 August 2024
Resolution: Received photographic evidence the 6 missing life jackets were placed on baord.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 August 2023 Resolved
13104: Individual power pumps used for separate spacesare to be controlled from a central control point and must have a means at control point to indicate operation. Visual indicator for aft hold did not illuminate when tested. 46 CFR 182.520 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Witnessed satisfactory test of the aft compartment bilge indicator.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 August 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel Owner/Operator failed to complete the required annual inspection by the due date of August 1, 2023. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2024
Resolution: An annual inspection was completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found rot on chine beam in space aft of engine compartment STBD side. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found rot on plywood decking plating IVO Space aft of engine compartment STBD side FWD. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found wood rot on hull in space aft of engine compartment Port side. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found de-lamination of FRP in Lazarette. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 August 2023 Resolved
46CFR176.610(b) - An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. MI found crack in gel coating on STBD side aft hull below rub rail. Provide repair proposal for repair to like new condition.
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 24 August 2023
Resolution: Witnessed proper repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2023 Resolved
46CFR176.670 - The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. MI found STBD cutlass bearing wasted. Replace cutlass bearing to the satisfaction of [name withheld] to yard availability, extended requirment until 16SEP2023
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 7 September 2023
Resolution: Received photo evidence for cutlass bearing replacement
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 September 2022 Resolved
A buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. The vessel is required to have a life float in accordance with 46 CFR 180.200(c) Table and currently has a buoyant apparatus on board. 46 CFR 180.200(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2024
Resolution: The vessel now has a 12 person life float on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2021 Resolved
A submersible electric bilge pump may be used provided that a positive shutoff valve is installed at the hull penetration. Vessel was missing shutoff valve in lazarette and engine room valve was severely corroded. 46 CFR 182.520(e)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 8 September 2021
Resolution: O/O replaced valve
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 August 2021 Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter. The vessel had expired waterlight batteries in life float. 46 CFR 180.70(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 8 September 2021
Resolution: O/O replaced waterlight batteries.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Vessel has break in plywood located in starboard bow approx. 30" from the stem. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: O/O repaired as original.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Plywood deck around fuel oil tank was wasted. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: O/O replaced plywood deck.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Crack in gel coat on starboard side approx. 10' from the stem and 2' below gunnel. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Crack in gel coat has been repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. De lamination in lazarette, inboard and forward of port side rudder. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Delamination has been repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Port ventilation shutoff seperated from deck. Repair as original. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Port ventilation shutoff has been reglassed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 July 2021 Resolved
An internal structural exam conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of vessel's main strength members including the major internal framing, the hull plating and planking, voids and ballast, cargo, and fuel oil tanks. Transom rot in both aft corners. Submit repair proposal for repairs. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 29 July 2021
Resolution: Transom rot has been abated and epoxied over.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 April 2018 Resolved
Vessel's fwd and aft fuel tanks were not properly grounded. Ensure fuel tanks are properly grounded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Fuel tanks were properly grounded.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 April 2018 Resolved
Vessel's fuel fill on aft tank not properly grounded . Ensure fill is proplery grounded.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Fuel tank fills were propelry grounded.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 April 2018 Resolved
Vessel's port fuel filter leaking diesel fuel. Ensure filter is not leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Port filter was not observed leaking during operational test.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2018 Resolved
Vessel's electrical wiring was not properly supported throughout vessel. Ensure wires are properly supported.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Wires were properly supported.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2018 Resolved
Vessel's port/stbd water washdown pump's electrical wiring not properly connected. Enaure wires are connected using proper connectors.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Washdown pumps wiring was properly connected/installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2018 Resolved
E;ectrical conductor found with exposed wiring in wash down cmpt. Remove, properly connect wiring.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Exposed wire was removed from vessel.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 April 2018 Resolved
Vessel's stbd shaft bearing leaking water excessively. Ensure shaft is not leaking water excessively.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Bearing was tightened and shaft was not leaking water during operational tests.
Engineering › Bilge Water Management System › Pump
Issued 3 April 2018 Resolved
Vessel's forward bilge pump not operating properly. Ensure proper operation of pump.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Bilge pump was tested and was found to be operating properly.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 April 2018 Resolved
Excessive oil found in bilges. Remove excessive oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Owner removed excessive oil from bilges.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 3 April 2018 Resolved
Fire boy fixed extinguishing system electrical connection not properly connected. Connection is worn/improper. Ensure proper connection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 24 April 2018
Resolution: Fireboy connection was repaired and override was retested with satisfactory results.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 April 2018 Resolved
Portable fire extinguishers not in proper bracket suitable for size of extinguisher. Provide suitable bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Port. extinguisher had proper brackets.
Lifesaving › Lifebuoys › Serviceable
Issued 3 April 2018 Resolved
Vessel's life ring torn and color is faded. Replace with proper life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Vessel replaced life ring with non worn proper type.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2018 Resolved
Vessel's first aid kit has expired contents. Ensure contents have not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Owner replaced contents with non-expired type.
Documentation › Markings/Placards › Lifejacket Placard
Issued 3 April 2018 Resolved
Vessel's life jacket instruction placard did not have instructions for proper type I PFD's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 24 April 2018
Resolution: Owner placed proper life jacket donning placard onboard.
Lifesaving › Lifefloat › Netting
Issued 28 September 2017 Resolved
Lifefloat netting needs to get replaced.
Condition: Improper/Lack of Maintenance
Due 5 October 2017
Resolved 3 April 2018
Resolution: Owner repaired life float with proper repair kit and replaced netting.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2017 Resolved
Provide UL approved type auto bilge pump where non UL approved pumps are used.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner installed proper bilge pumps.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 25 July 2017 Resolved
Onboard pre-engineered fire fighting system for engine cmpt rated for 700 CF not 1000 CF as listed on the COI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: ER measured for cubic ft and determined that it is 600 CF. Not 1000 cubic feet that was previously listed on COI. Current fire boy system is sat.
Lifesaving › Lifefloat › Float-free Link
Issued 25 July 2017 Resolved
Weak link for life float assembly missing capacity tag. Provide tag or new weak link assembly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Lifefloat has appropriate weak link.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 25 July 2017 Resolved
Vessel stbd shaft leaking water excessively. Ensure shaft is not leaking water excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 25 July 2017
Resolution: Vessel owner adjusted shaft packing.
Engineering › Lubricating Oil Storage/Transfer System › Filter/Strainer
Issued 25 July 2017 Resolved
Port engine oil filters leaking oil excessivley. Ensure oil is not leaking excessively.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Operated engine and did not observe any oil leaking from filter.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 July 2017 Resolved
Provide current copy of Certificate of Documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner provided current COD.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 July 2017 Resolved
Provide current copy of FCC Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner provided current certificate.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 July 2017 Resolved
Emergency instructions were not onboard vessel. Provide current copy of emergency instructions and post onboard vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 28 September 2017
Resolution: Owner provided updated emergency instructions.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 July 2017 Resolved
PFD's have tears and require maintenance. Ensure PFD's are repaired with proper approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 3 April 2018
Resolution: Owner repaired or replaced worn PFD's.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 April 2017 Resolved
Replace fuel tank flexible line withe approved hose IAW 46 CFR 182.450(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 24 May 2017
Resolution: Owner purchased proper flexible vent hose.
Construction/Loadline › Hull › Stringer
Issued 5 April 2017 Resolved
Bilge stringers IWO of steering compt. decayed/rotted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2017
Resolved 25 April 2017
Resolution: Owner removed decayed stringers and installed new stringers IVO steering cmpt.
Construction/Loadline › Hull › Transverse Frame
Issued 5 April 2017 Resolved
Transverse deck beam IWO steering cmpt rotted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2017
Resolved 25 April 2017
Resolution: Owner removed decayed transverse beam and installed new beam.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2017 Resolved
Port side side shell/transom butt joint rotted IWO of steering cmpt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner installed new plywood and FRP on side shell.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2017 Resolved
Stbd side sideshell/transom butt joint rotted IWO steering cmpt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner installed new plywood insert and FRP.
Construction/Loadline › Structures › Deck Plating
Issued 5 April 2017 Resolved
Port side gunwale rotted crop/renew as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner removed damaged gunwale and glassed over with new FRP.
Construction/Loadline › Hull › Side Shell
Issued 5 April 2017 Resolved
Port side hull damaged excessively repair/renew
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Owner ground down damaged portion and glassed over with new FRP.
Construction/Loadline › Hull › Transverse Frame
Issued 5 April 2017 Resolved
Pot side transverse deck beam and frame rotted IWO of fuel cmpt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 24 May 2017
Resolution: Owner removed rotted beam and installed new beam.
Construction/Loadline › Hull › Keel Plate
Issued 5 April 2017 Resolved
Stbd side keel gel coat damaged repair/renew
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 22 June 2017
Resolution: Observed photograph of repaired keel/skeg area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2017 Resolved
Remove/properly dead end exposed electrical wiring IWO of engine cmpt.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 25 July 2017
Resolution: Owner removed electrical wires from E/R.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 April 2017 Resolved
Replace fuel tank fill line with approved hoses IAW 46 CFR 182.445(g).
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 24 May 2017
Resolution: Owner purchased proper flexible fuel fill hose.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.