Documentation record
Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 20 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
1 May 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8120325
2 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7904922
4 April 2024
Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7889141
9 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684801
21 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611937
2 May 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7442248
25 February 2022
Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7402120
26 June 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7248639
17 February 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141244
23 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6931035
24 February 2020
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6914462
3 April 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6660008
29 September 2018
DAPI Audit · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6611263
4 June 2018
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6434212
2 February 2018
Administrative Inspection · Drydock Exam · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348598
27 March 2017
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112557
8 February 2016
DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5811675
28 January 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5805729
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 May 2025
Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. Ventilation closures were unable to me kept in place due to configuration.
46 CFR 182.465 (c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
Resolution: Vessel rep installed a cleat to support the wire that held the ventilation closures for the engineroom.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 May 2025
Resolved
Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. HRU and painter line were not configured correctly and would not have floated free.
46 CFR 180.130 (a) (2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
Resolution: Vessel operator adjusted the HRU on the IBA correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2025
Resolved
The number and identification of the items stowed inside must be marked in clearly with numbers on each container for life jackets. Life jackets were not all stowed in their designated, labeled compartments.
46 CFR 185.604 (f)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
Resolution: Vessel operator arranged the lifejackets to proper stowage locations.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 1 May 2025
Resolved
The drill entry shall include a general description of the drill scenario and training topics. Drills did not sufficiently describe the evolution.
46 CFR 185.524(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
Resolution: Vessel rep educated on proper drill log requirements.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 May 2025
Resolved
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12. No eyewash present.
46 CFR199.175(b)(10)(i)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
Resolution: Vessel rep bought new eye wash.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent...Closure device did not seal air shutoff vent, provide appropriate means of sealing vent to the satisfaction of the Marine Inspector.
46 CFR 182.465(h)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 June 2024
Resolution: Operator installed closing device to create a seal in the e/r
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2024
Resolved
The rules concerning shapes shall be complied with by day...No day shapes were onboard vessel.
33 CFR 83.20(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspection of lifesaving equipment and systems, including the inspection of each hydrostatic release unit...The vessel's hydrostatic release for the inflatable buoyant apparatus was incorrectly arranged, operator made correction on the spot.
46 CFR 176.808(a)(5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Corrected installation during inspection. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 April 2024
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. The engine room cables were supported by plastic supports.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 2 May 2024
Resolution: Installed metal supports.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 May 2023
Resolved
Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI. The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Vessel had expired alcohol testing swabs onboard. Vessel limited to 2 hours from testing facility until testing strips onboard. 46 CFR 4.06-3(a)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: New Alcohol testing strips placed onboard.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 May 2023
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of §80.1101(c)(2). Vessel has VHF installed that is not connected to GPS. 46 CFR 184.502; 47 CFR 80.905(a)(1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 23 May 2023
Resolution: Owner has connected GPS to VHF-DSC.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 9 May 2023
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. The Coast Guard will review all information provided and will determine whether: The applicant is physically and medically qualified for the medical certificate without any limitations, waivers and/or other conditions. During inspection, owner was not able to produce a medical certificate. 46 CFR 10.301(a)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 9 June 2023
Resolution: Received verification of new medical card for operator.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 February 2022
Resolved
A vessel that is exposed to salt water more than three months in a 12 month period since the last examination must undergo a drydock examination and an internal structural at least every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on the COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2022
Resolution: Vessel has completed worklist for credit drydock.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 February 2022
Resolved
The owner, managing operator, or qualified facility must conduct the following tests: Portable extinguishers must be inspected/maintained by NFPA 10. Due for annual service. 46 CFR 810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 March 2022
Resolution: Portable fire extinguishers inspected by Fire King.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2022
Resolved
For fixed gas systems, the inspections and tests required by table 176.810(b). Annual service due. 46 CFR 810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 March 2022
Resolution: Operator has had service done on fixed system. Report in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 April 2019
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and inflates automatically. The hydrostatic release for the IBA was installed incorrectly. The lashing straps securing the IBA to the bracket was not installed on the hydrostatic release; rendering the hydrostatic release inoperable. Install hydrostatic release properly. Owner rectified deficiency on the spot.
46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 April 2019
Resolved 3 April 2019
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2019
Resolved
A vessel not required to have a power driven fire pump must have at least three 2 and 1/2 gallon fire buckets. Only two fire buckets were made available during the inspection. The operator corrected the deficiency on the spot.
46 CFR 181.610
Action required: 10 - Deficiency Rectified
Due 3 April 2019
Resolved 3 April 2019
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 June 2018
Resolved
A pre-engineered fixed gas fire extinguishing system must shut down all engines within the space protected. Prove the proper operation of the generator and its automatic shutdown as required. 46 CFR 181.420
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2018
Resolved 7 June 2018
Resolution: Owner proved proper operation of the pre-engineered fixed gas fire fighting engine shut downs and resets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2018
Resolved
Ring buoy is not readily accessible and stowed in a way that it can be readily cast loose. 46 CFR 180.71
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2018
Resolved 7 June 2018
Resolution: Owner moved the life ring buoy to a readily accessible location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2018
Resolved
Replace leaky water pump on vessel's generator. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2018
Resolved 7 June 2018
Resolution: Owner replaced water pump for the vessel's generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2018
Resolved
Install guard for exposed belt on vessel's generator. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 23 October 2018
Resolution: Vessel rep installed a sufficient metal guard around the generator belt.