Records from 1986 to 2025. Most recent: inspection, 24 April 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 58
24 April 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 8102620
1 May 2024
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7904203
15 April 2024
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7885282
30 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7701054
23 December 2022
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7613154
15 November 2022
Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7594783
1 April 2022
Hull Examination · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7424508
27 July 2021
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7282531
17 August 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7035845
18 May 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6955609
16 August 2019
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6785786
29 May 2018
Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6421968
22 August 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6250059
24 August 2016
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5974853
12 May 2016
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5921858
26 August 2015
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5211852
18 August 2015
Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 5228058
27 August 2014
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4975332
4 June 2012
Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4357531
22 February 2011
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3950368
29 July 2009
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3551895
29 May 2008
MARPOL Annex V Examination · COI Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3295622
12 May 2008
Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3205170
22 April 2008
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3195407
2 August 2006
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2735281
8 May 2006
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2680040
6 July 2005
Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2422887
3 May 2004
Hull Examination · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2078390
21 April 2003
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1783555
12 November 2002
Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1704502
13 May 2002
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1702514
16 May 2001
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1428050
5 May 2000
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1062441
20 January 2000
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 816198
30 September 1999
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1395334
25 August 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780319
13 May 1998
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1418345
29 April 1997
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1409671
14 June 1996
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1374655
25 May 1995
Re-Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 873524
5 January 1995
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1166774
14 June 1994
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1327791
26 May 1994
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1171294
11 May 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1379800
14 May 1992
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 959207
26 February 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 956594
1 August 1991
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1247557
9 July 1991
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1001032
24 April 1990
COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225902
6 April 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1226112
12 February 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1222388
2 January 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1230668
2 January 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1235043
11 May 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194955
3 April 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194954
21 April 1988
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1034748
9 April 1987
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1022862
28 April 1986
Credit Drydock · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1307297
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2025
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Marine Inspector observed 06 life jackets without lights. Operator to replace missing lights to the satisfaction of the Marine Inspector.
46 CFR 180.75(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 24 April 2025
Resolution: New lights purchased.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 April 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Marine Inspector observed engine room ventilation opening under deck seating that is difficult to properly secure. Operator to rectify to the satisfaction of the attending Marine Inspector prior to the next credit dry-dock.
46 CFR 182.465(h)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 12 May 2025
Resolution: Operator provided photo documentation of satisfactory solution for sealing opening in the event of a fire.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 May 2024
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Operator stated they were conducting drills, but not logging them. Instructed operator to start logging drills, beginning with drills conducted for annual inspection.
46 CFR 185.524 (d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 1 May 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 May 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Operator stated they were conducting drills, but not logging them. Instructed operator to start logging drills, beginning with drills conducted for annual inspection.
46 CFR 185.520 (f)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 1 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2024
Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Vessel had only two fire buckets. Operator purchased third fire bucket.
46 CFR 181.610
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 1 May 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Vessel had back gate unable to properly close, making railing protection incomplete. Operator repaired gate during inspection.
46 CFR 177.900 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 May 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 1 May 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel had expired alcohol test strips. Operator purchased new test strips.
46 CFR 4.06-15 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 August 2020
Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 5 October 2020
Resolution: Updated
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2020
Resolved
Hose leading from pump to deck wash down fitting was found dry rotted, renew
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 5 October 2020
Resolution: Hose renewed
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 17 August 2020
Resolved
Old fresh water pipe that penetrates forward engine room bulkhead was found cut. Remove system or blank system at bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 5 October 2020
Resolution: System blanked.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2018
Resolved
Vessel must have a valid FCC Safety Radiotelephony certificate onboard.
Certificate that was onboard was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2018
Resolved 11 September 2018
Engineering › Bilge Water Management System › Strainer
Issued 22 August 2017
Resolved
Provide a screen on bilge suction pipe in lazarette.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 29 May 2018
Resolution: Screen replaced.
Stability › Watertight Integrity › General
Issued 22 August 2017
Resolved
Replace sink drain hose in void space
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 5 September 2017
Lifesaving › Lifebuoys › Serviceable
Issued 22 August 2017
Resolved
Replace retro tape on rear life ring.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 5 September 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 August 2016
Resolved
medication were outdated and need to be replaced
Due 19 September 2016
Resolved 19 September 2016
Resolution: medications are up to date
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2016
Resolved
All deck railings were removed to be replaced.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2016
Resolution: Witnessed newly installed railings
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 August 2015
Resolved
Provide current navigation publications onboard - Coast Pilot, Light list, tide & current tables
46CFR 184.420
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 24 August 2016
Resolution: Cleared on 24AUG2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 August 2015
Resolved
Provide Employee Assistance Program Hotline number onboard
46CDR16.401
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 24 August 2016
Resolution: cleared on 24AUG2015
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 26 August 2015
Resolved
Repair starboard fuel shutoff valve
46CFR182.455
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 24 October 2016
Resolution: cleared on 24AUG2015
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 August 2015
Resolved
Seal bulkhead penetration on Fwd stbd E/R.
46CFR179.320
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 24 August 2016
Resolution: cleared on 24AUG2016
Stability › Incline Test › General
Issued 27 August 2014
Resolved
Conduct Simplified Stability Test to meet weight standards that became effective on December 1, 2011
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2014
Resolution: O/O conducted new SST.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 February 2011
Resolved
Vessel did not complete 2010 annual exam. Complete Inspection for Certification
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2012
Resolution: Conducted annual inspection.
Communications › Radio Communications › EPIRB
Issued 2 August 2006
Resolved
Install EPIRB in float free location on vessel
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 22 September 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 2 August 2006
Resolved
Provide FCC safety certificate
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 26 September 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 August 2006
Resolved
Install or repair inoperable high level alarm switch in mid-ship void. While carrying passengers inspect void every 30 min for flooding.
Due 2 September 2006
Resolved 2 August 2006
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 8 May 2006
Resolved
Replace port shaft cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 16 May 2006
Resolution: Corrected.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 May 2006
Resolved
Make watertight collision bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2006
Resolved 16 May 2006
Resolution: Corrected.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 May 2006
Resolved
Make p/s shaft visable for inspection.
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 16 May 2006
Resolution: Corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 April 2003
Resolved
Provide Red Cross first aid/CPR Certification Card for one crew member.
Due 21 May 2003
Resolved 6 July 2005
Resolution: Red Cross Cards were provided.
Construction/Loadline
Issued 16 May 2001
Resolved
REPAIR ENGINEROOM HATCH COVER LATCHES
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Accommodation/Occupational Safety
Issued 16 May 2001
Resolved
REPAIR CENTER AFT RAIL BRACKET
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Engineering
Issued 16 May 2001
Resolved
ADJUST PORT MAIN ENGINE SHAFT PACKING
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Navigation
Issued 16 May 2001
Resolved
OBTAIN FCC STATION LICENSE AND COMMUNICATIONS ACT CERTIFICATE
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Fire Fighting
Issued 16 May 2001
Resolved
FABRICATE/INSTALL VENT COVERS FOR ENGINEROOM
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Construction/Loadline
Issued 16 May 2001
Resolved
CLEAN ENGINEROOM BILGES
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Fire Fighting
Issued 16 May 2001
Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 May 2001
Resolved 21 April 2003
Resolution: Verified correction
Fire Fighting
Issued 16 May 2001
Resolved
LABEL MANUAL FIXED FIRE EXTINGUISHER PULL HANDLE ON OUTSIDE OF CABINET
Condition: Unknown
Due 16 June 2001
Resolved 21 April 2003
Resolution: Verified correction
Construction/Loadline
Issued 30 September 1999
Resolved
Install checkvalves in bilge system as req by 182.510.
Condition: Unknown
Due 1 December 1999
Resolved 11 January 2000
Lifesaving
Issued 30 September 1999
Resolved
Post PFD donning instructions, emergency broadcast placard, and compass deviation table. Apply vessel registration decal to EPIRB.
Condition: Unknown
Due 1 December 1999
Resolved 11 January 2000
Lifesaving
Issued 30 September 1999
Resolved
Procure CG approved 1st aid kit.
Condition: Unknown
Due 1 December 1999
Resolved 11 January 2000
Electrical
Issued 30 September 1999
Resolved
INstall cover on genset electrical/junction box.
Condition: Unknown
Due 1 December 1999
Resolved 11 January 2000
Lifesaving
Issued 14 June 1996
Resolved
Vessel PFD stowage to small for the amount of PFD's stowed. Several PFD's stowed so as not to allow for easy access.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Lifesaving
Issued 14 June 1996
Resolved
New location for PFD's were not labeled.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Lifesaving
Issued 14 June 1996
Resolved
Watertight hatch cover on aft deck did not have warning label.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Engineering
Issued 14 June 1996
Resolved
Starboard main engine jacket water temperature gauge on bridge not operable.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Engineering
Issued 14 June 1996
Resolved
Exhaust cooling pipes on both main engines are leaking water in water jacket at weld joint.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 14 June 1996
Resolved
Vessel engine hatches hold downs missing.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 25 May 1995
Resolved
Install hold down latches on engine room hatch covers.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 14 June 1994
Resolved
CONDUCT UNDERWAY DRILLS WITH REGULAR DECKHAND
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Construction/Loadline
Issued 14 June 1994
Resolved
REPAIR LEAK IN TRANSOM.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Documentation
Issued 14 June 1994
Resolved
RENEW FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Navigation
Issued 14 June 1994
Resolved
POST MAGNETIC DEVIATION TABLE ON BOARD VESSEL.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Lifesaving
Issued 14 June 1994
Resolved
REPLACE BATTERY ON EPIRB.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Fire Fighting
Issued 14 June 1994
Resolved
INSTALL TWO B-II FIRE EXTINGUISHERS
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Fire Fighting
Issued 14 June 1994
Resolved
INSTALL PROPER HOSE FITTINGS ON HAND FIRE PUMP.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Construction/Loadline
Issued 26 May 1994
Resolved
Repairs open screw holes on bottom of vessel around port and starboard mainengine raw water intakes.
Condition: Unknown
Due 1 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 26 May 1994
Resolved
Repair fiberglass hull on port side aft in three areas noted by inspector.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Engineering
Issued 26 May 1994
Resolved
Repair port main engine fiberglas exhaust pipe at first soft connection from engine. Repair to be to the satsfaction of an attending inspector.
Condition: Unknown
Due 1 June 1994
Resolved 25 October 1994
Engineering
Issued 14 May 1992
Resolved
Provide safety guards for pulleys and belts on both main engines.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Engineering
Issued 11 May 1989
Resolved
DEMONSTRATE PROPER OPERATION OF SHIPS SERVICE GENERATOR. THIS ITEM TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR FOR THE COGNIZANT OCMI.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Documentation
Issued 11 May 1989
Resolved
POST THE VESSEL'S STABILITY LETTER UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL IN THE PILOTHOUSE OF THE VESSEL.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Lifesaving
Issued 11 May 1989
Resolved
PROVIDE THE PROPER WEAK LINK FOR THE VESSEL'S BA. THIS ITEM TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Lifesaving
Issued 11 May 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE WATER LIGHT ATTACHED TO THE RING BUOY. THIS ITEM TO BE DONE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR OF THE COGINZANT OCMI AND PRIOR TO THE OPERATION OF THE VESSEL WITH PASSENGERS ON BOARD DURING REDUCED VISIBILITY.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Navigation
Issued 11 May 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE SHIP'S HORN. THIS ITEM TO BE ACCOMPLISHED PRIOR TO THE CARRIAGE OF PASSENGERS AND TO THE SATISFACTION OFTHE ATTENDING MARINE INSPECTOR FOR THE COGNIZANT OCMI.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Lifesaving
Issued 11 May 1989
Resolved
PROVIDE APPROPRIATE NUMBER OF COAST GUARD APPROVED PYROTECHNIC DISTRESS SIGNALS FOR DAY LIGHT OPERATIONS. THIS ITEM TO BE ACCOMPLISHED PRIOR TO THE CARRIAGE OF PASSENGERS ON RUNS OF OVER 30 MINUTES AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR FOR THE COGNIZANT OCMI.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Documentation
Issued 11 May 1989
Resolved
PROVIDE A CURRENT FCC CERTIFICATE. THIS ITEM TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR FOR THE COGNIZANT OCMI.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989