← All vessels
QUEEN MARY
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southwest District (CGD-SW) · Other hulls named QUEEN MARY
QUEEN MARY is a 1999 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 1999, most recently in May 2025, along with 57 deficiencies and 1 operational control.
Records from 1999 to 2025. Most recent: inspection, 14 May 2025.
- Built
- 1999
- Last inspected
- 14 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 57 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1099150
498855
Flag
UNITED STATES
—
Maury page id
psix-498855
Inspections, by type
…with no type recorded1
Years with a record
22 calendar years (1999–2025)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS · LAKE HAVASU · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
14 May 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8141021
9 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909650
16 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684921
28 June 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7487216
17 August 2021
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7275530
15 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6974346
30 May 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6964262
27 August 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6796758
7 August 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501266
10 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6233651
7 September 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5989622
10 June 2014
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4862880
22 December 2011
Simplified Stability Test · Annual Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4212768
11 June 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3229067
29 May 2007
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2952237
29 May 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2984803
9 May 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639847
7 June 2005
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2362427
2 May 2005
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2354994
2 September 2004
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2153944
23 July 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1846367
12 July 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1640345
10 July 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1457967
27 July 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1401301
30 June 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 225534
14 September 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 785748
20 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1100912
20 July 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1109530
3 July 1999
Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1464203
Deficiency record · 57
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 14 May 2025
Resolved
Each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel. MI observed throughhull fitting for starboard aft engine room bilge did not have valve or metallic fitting. Install valve and replace with metallic fitting to the satisfaction of the MI. 46 CFR 179.350(c)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 January 2025
Resolved
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section. Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel has not made the required improvements of their fire drill logs and has surpassed the required time frames set out. Vessel is restricted from carrying passengers until requirements have been met.
46 CFR 176.500(b)(1)(ii)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 May 2024
Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had expired flares on board. Replace expired flares to the satisfaction of the Marine Inspector.
46CFR180.68(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2024
Resolved
All hardware shall be brass, bronze, or stainless steel, and of the approximate size indicated by the drawings. Steel hardware, protected against corrosion by plating, is not acceptable. Snap hook springs shall be phosphor bronze or other suitable corrosion-resistant material. One lifejacket was missing its corrosive resistant clip. Repair the lifejacket to the satisfaction of the Marine Inspector.
46CFR180.71(c)
46CFR160.055-3(i)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel was missing the required lanyards. Install lanyards to the satisfaction of the Marine Inspector.
46CFR181.610
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2024
Resolved
The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Not all fire buckets were properly labeled. Label all fire buckets to the satisfaction of the Marine Inspector.
46CFR181.610
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2024
Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Vessel did not have any logs for drills. Vessel conducted fire drills during inspection, log drills to the satisfaction of the Marine Inspector.
46CFR185.524(d)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Vessel did not have any logs for drills. Vessel conducted drills during inspection, log drills to the satisfaction of the Marine Inspector.
46CFR185.520(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2024
Resolved
A vessel must have two independent means of controlling each propulsion engine. Control must be provided for the engine speed, direction of the shat rotation, and engine shutdown. Vessel does not have second independent means of controlling propulsion engine. Install second independent means of controlling propulsion engine to the satisfaction of the Marine Inspector.
46CFR182.620(a)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 May 2024
Resolved
Except as provided in paragraph (c) of this section, a vessel must be provided with an auxiliary means of steering that is: (1) Of adequate strength; (2) Capable of moving the rudder from 15 degrees on one side to 15 degrees on the other side in not more than 60 seconds with the vessel at one-half its maximum service speed ahead, or 7 knots, whichever is greater; and (3) Controlled from a location that permits safe maneuvering of the vessel and does not expose the person operating the auxiliary means of steering to personnel hazards during normal or heavy weather operation. Vessel has no means of a secondary means of steering on board. Install a seoncdary means of steering to the satisfaction of the Marine Inspector.
46CFR182.620(a)
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 May 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Vessel has exposed rotating machinery when you first enter the engine room. Install a protective guard to the satisfaction of the Marine Inspector.
46CFR177.960
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel had multiple lifejackets that did not have the vessel’s name. Operator satisfactorily marked those life jackets during the inspection.
46CFR185.604(b)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 June 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's aspirin was expired.
46 CFR 184.710
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 August 2019
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly covered by a cover, guard, or rail. Shafting from Engine auxiliary to para-sail winch has no adequate guard. Belt Pullies on front of Engine are not adequately guarded. Provide Guards for winch shafting and Engine belt pullies prior to April 1st, 2020.46 CFR 177.960
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 August 2018
Resolved
Both of the vessel's high water alarms failed to indicate at the operating station. Vessel must correct issue with the high level alarms prior to carrying passengers.
Documentation › Logs/Records › Drug Test Records
Issued 10 August 2017
Resolved
Add all crew in safety sensitive position to drug and alcohol testing program. 46CFR16
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 August 2017
Resolved
Provide first aid kit meeting the requirements of 46CFR160.041
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 December 2011
Resolved
Provide current servicing to expired portable extinguishers and fixed fire system. 46 CFR 181.400
Lifesaving › Lifebuoys › Serviceable
Issued 22 December 2011
Resolved
Replace or repair damaged life ring buoy. 46 CFR180.70
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 December 2011
Resolved
Replace water light battery. 46 CFR 180.70
Engineering › Bilge Water Management System › Pump
Issued 22 December 2011
Resolved
Replace electric submersible bilge pump with UL approved type. 46 CFR 182.520 (e)
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 December 2011
Resolved
Renew extinguished navigation bulbs. NAV Rules
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 11 June 2008
Resolved
Prove proper operation of installed flammable vapor detector for engine compartment (gas engine) IAW CFR 46.182.480.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
No company policy.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Drug testing background checks are not being completed.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
No EAP policy in existance or made available to employees.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
No hotline number made available to employees.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
Employer does not have a Substance Abuse Professional's name and contact information.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2007
Resolved
No record of MIS form being ever submitted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 May 2007
Resolved
Expired eye wash.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 May 2007
Resolved
Found 2 child PFD's with no stenciling of vessel name. Provide stenciling on 2 child PFD's per 46 CFR 185.604.b.
Stability › Watertight Integrity › General
Issued 2 May 2005
Resolved
Repair hole in fiberglass in way of inboard side of operating station.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 September 2004
Resolved
Provide proof of company drug testing program.
Fire Fighting › Fire Bucket › Quantity
Issued 2 September 2004
Resolved
Provide on board one additional fire bucket.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 2 September 2004
Resolved
Install lifering float light bracket permanently to vessel.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 2 September 2004
Resolved
Provide segregated life jacket storage for adult and child sized personel flotation devices.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 September 2004
Resolved
Vessel shall not operate as an inspected vessel with passengers for hire until receiving a current COI.
Construction/Loadline › Hull › Bottom Plating
Issued 2 September 2004
Resolved
Vessel shall perform credit drydocking in the presence of U.S. Coast Guard marine inspector prior to operating with passengers.
Engineering
Issued 23 July 2003
Resolved
Show proof vessel's hydraulics for the parasail winch is operating satisfactory.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 12 July 2002
Resolved
Install interlock switch so that engine cannot be started without engine space ventilation fans in operation. LEGACY COMPONENT DESC: Ventilation
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 July 2002
Resolved
Make bilge alarm operate properly LEGACY COMPONENT DESC: Bilge Alarm
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 July 2002
Resolved
Provide current Certificate of Documentation as proof of renewal. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 12 July 2002
Resolved
Document crew drills in vessel logbook. LEGACY COMPONENT DESC: Logbook (official)
Navigation
Issued 27 July 2000
Resolved
PROVIDE EMERGENCY BROADCAST PALCARD. (46 CFR 184.506)
Documentation
Issued 27 July 2000
Resolved
PROVIDE FCC OPERATOR'S PERMITS FOR ALL MASTERS OPERATING THE QUEEN MARY.
Documentation
Issued 27 July 2000
Resolved
PROVIDE OIL POLLUTION PLACARD.
Documentation
Issued 27 July 2000
Resolved
PROVIDE MARPOL V (GARBAGE) PLACARD.
Documentation
Issued 27 July 2000
Resolved
PROVIDE EMERGENCY INSTRUCTION LIST. 46 CFR 185.510
Documentation
Issued 27 July 2000
Resolved
PROVIDE PROOF OF DOCUMENTATION OR STATE NUMBERS.
Electrical
Issued 27 July 2000
Resolved
PROVIDE EMERGENCY LIGHTING.
Documentation
Issued 27 July 2000
Resolved
PROVIDE FCC STATION LICENSE.
Fire Fighting
Issued 27 July 2000
Resolved
PROVIDE PROOF OF SERVICE FOR HALON FIXED SYSTEM IN ENGINE ROOM.
Lifesaving
Issued 27 July 2000
Resolved
LABEL LIFERING AND PROVIDE 60 FT OF LINE. 46CFR180.70 / 46CFR185.605
Lifesaving
Issued 27 July 2000
Resolved
START A TRAINING LOGBOOK (RECORD OF REQUIRED DRILLS).
Documentation
Issued 3 July 1999
Resolved
Provide licensed operator enrolled in an approved drug testing program.
Lifesaving
Issued 3 July 1999
Resolved
Install line on water light.
Lifesaving
Issued 3 July 1999
Resolved
Conduct man overboard drill and fire drill in presence of a Marine Inspector.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.