MAURY USCG vessel records Sign in
← All vessels

AZAMARA ONWARD

AZAMARA ONWARD is a 1999 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1999, most recently in December 2025, along with 64 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 1999 to 2025. Most recent: inspection, 3 December 2025.

Built
1999
Last inspected
3 December 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9187887 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
498872
Flag
MALTA
—
Maury page id
psix-498872

Inspections, by type

…with no type recorded13
…past their stated due date2
Years with a record 22 calendar years (1999–2025)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it30312 - Convention (Subpart B), Gross Ton
11493 - Convention (Subpart B), Net Ton
30312 - Regulatory (Subpart C or D), Gross Ton
11493 - Regulatory (Subpart C or D), Net Ton
3188 - Dead Weight, Metric Ton
16147 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

3 December 2025 COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8275280
9 February 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8076931
28 January 2025 Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 8072485
9 December 2024 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8041530
22 December 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7841899
30 November 2023 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7829062
1 December 2022 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7602099
27 November 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7599978
17 April 2020 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6998782
17 March 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6928043
22 December 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6876923
12 June 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6712455
22 December 2018 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6601572
21 February 2018 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6358423
22 December 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6326232
22 February 2017 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6092363
10 January 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068666
15 December 2016 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6058220
20 January 2016 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5800711
19 January 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5799664
26 August 2015 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5761522
5 August 2015 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5214721
16 July 2015 COC-CVE Quarterly · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5186608
13 July 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5168178
26 June 2014 ILO-147 Exam · STCW 95 Exam · PII Safety Exam · Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4900363
5 June 2014 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4881360
28 January 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4237239
16 December 2011 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4206444
22 December 2010 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3908344
13 January 2010 MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3662729
2 July 2009 COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3521394
1 July 2009 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3520823
2 January 2009 ISPS II Exam · PII Safety Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3387706
29 October 2007 COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3089287
9 May 2007 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2928105
9 May 2006 COC-CVE Annual · MARPOL Annex V Examination · ISPS III Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2644353
12 May 2005 COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2331689
2 August 2004 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2155398
30 July 2004 ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2151002
3 June 2004 Security Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2086892
15 May 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2198479
14 May 2004 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2064406
24 September 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1912105
8 July 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1843441
26 June 2003 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1828408
27 May 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1802506
27 May 2003 Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1803255
27 May 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1803438
22 May 2003 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 1810574
25 October 2002 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1730529
24 October 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1731416
11 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 431665

Deficiency record · 64

01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 28 January 2025 No resolution recorded
Vessel was operating within US navigable waters (American Samoa) without an approved VRP for the area.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 December 2024 No resolution recorded
The company and the ship shall comply with the requirements of the International Safety Management Code. PSCO's identified multiple A60 Fire Screen Doors (FSD) that did not close within the prescribed times of the vessels FSD maintenance procedure. 74 SOLAS 20 IX/3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2025 — due date passed with no resolution recorded
Resolution: Class report submitted
14 - Pollution Prevention › 146 - MARPOL Annex VI › Type approval certificate of incinerator
Issued 9 December 2024 Resolved
Shipboard incinerators described shall possess an IMO Type Approval Certificate for each incinerator. Incinerator walls are to be protected with insulated fire bricks/refactory and a cooling system. PSCO identified refactory was broken inside incinerator. MARPOL 2017 Annex VI/16.6.1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2025
Resolved 24 December 2024
Resolution: Received class report attesting to repairs.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Diesel engine relating to air pollution control
Issued 22 December 2023 Resolved
The Administration of a Party may allow any fitting, material, appliances, or apparatus to be fitted in a ship if arrangement is at least equivalent to the emissions reduction of MARPOL Annex VI. The EGCS installed onboard is not functioning as designed. MARPOL VI/4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2024
Resolved 9 January 2024
Resolution: Sector Miami PSC received documentation from the class society acknowledging the deficiency and issuing a Condition of Authority with a due date of 07FEB2024.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2022 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall satisfy the following requirements: indication shall be provided at the fire door indicator panel in the continuously manned central control station whether each of the remote-released doors are closed. FSD 904 in way of forward stairway, deck 9, does not accurately convey status on indicator panel. 74 SOLAS (01) 11-2/30.6
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 6 December 2022
Resolution: Class survey statement reported :"Repaired/rectifiied: the door was repaired as agreed with the USCG and satisfactoory retested by DNV."
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 December 2019 Resolved
Where the contents and use of a space are such that there is a doubt to its classification, the space shall be treated as a space within the relevant category having the most stringent boundary requirements. Open locker space on deck 9 aft in pax buffet area is being used to store flammable materials (cardboard, plywood panels, flame locker) in the manner of a Category 13 service space but is classified as a Category 5 open deck space. The sapce is not enclosed as a Category 13 space should be, nor does it have fire detection or suppression required of such a space by SOLAS 01 10.6.1.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 22 December 2019
Resolution: All flammable materials in the open locker space on deck 9 aft were removed and relocated to an appropriate approved storage location.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 December 2019 Resolved
Fire doors shall be self-closing and the approx. time of closure shall be no more than 40s and no less than 10s. Fire doors 911, 715, 717, 721, 407, 314, and 367 did not close properly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 December 2019
Resolution: Fire doors 911, 715, 717, 721, 407, 314, and 367 were adjusted by ships crew, re-tested and found to close properly.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 22 December 2018 Resolved
The construction of all doors in "A" class divisions, with the means of securing them when closed shall provide resistance fire as well as to the passage of smoke and flame, equivalent to that of the bulkheads in which the doors are situated. Roller shutter for deck 09 barbeque grill does not completely close. 74 SOLAS (2001) II-2/30.2
Action required: 10 - Deficiency Rectified
Due 22 December 2018
Resolved 22 December 2018
Resolution: Roller shutter corrected to close flush with the deck.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 December 2018 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall have a closure rate of no more than 40 seconds and no less than 10 seconds. Numerous fire doors throughout the vessel closed at a rate of less than 10 seconds. 74 SOLAS (2001) II-2/30.4.2
Action required: 10 - Deficiency Rectified
Due 22 December 2018
Resolved 22 December 2018
Resolution: Door closure rates were adjusted to meet the regulation.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 26 June 2014 Resolved
During random tests of the smoke detection system onboard, smoke detector in Panorama Galley failed to function & unlabeled (no number), unsat. as per Chapter II-2 Construction Detection Reg 14, 2.1.2 &2.2.1 and Reg 7-2.2 (Fire Safety Code) & 5.2. Several smoke detectors in various areas found not identified properly (no labels) or worn out identification numbers/letters as per Fire Safety Code..
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 26 June 2014
Resolution: All corrected on spot, renew not working smoke detector & labeled all detectors. Electrician will go through the system to check each smoke detector numbered properly as per detection on the bridge, sat.
Personnel › Certificates/Documents/Licenses › STCW Certificate of Proficiency, Fast Rescue Boat
Issued 16 December 2011 Resolved
Every candidate for a certifcate of proficiency in fast rescue boats shall be the holder of a certificate of proficiency in survival craft and rescue boats other than fast rescue boats, have attended an approved training course; and meet the standard of competence of proficiency in fast rescue boats.Operators for fast rescue boats did not hold documentation attesting to their proficiency STCWVI2.2
Action required: 705 - Other - as specified
Due 16 January 2012
Resolved 13 December 2012
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 December 2010 Resolved
0750- Fire prevention- Cabin doors in "B" class divisions shall be of self closing type. Hold back hooks are not permitted. All passenger corridor cabin doors held open with wedges. SOLAS 2009 CH II-2 REG 9.4.1.2.2
Action required: 705 - Other - as specified
Due 26 January 2011
Resolved 16 December 2011
Resolution: Verified cabin doors were closed during drill.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 December 2010 Resolved
0700 - Fire fighting appliances: Fire doors in MVZ, bulkheads, galley boundaries and stairway enclosures shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire door 1003 was found with a broken door activator and Fire Door 904 will not completely shut. 2004 Cons Ed, Chap II-2, Reg 9.4.1.1.4.
Due 22 December 2010
Resolved 22 December 2010
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 22 December 2010 Resolved
0710- Fire Prevention- The contents of a space must be appropriate for the space category as per the vessels SFP Plan. Found Flammable liquids inappropriately located in deck 3 print shop room 302 which is not a category 14 space. Also found flammable liquids inappropriately located on deck 9 spa locker which is not a category 14 space. SOLAS 09 CH 11-2 Reg 9 2.2.5.2.2
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 16 December 2011
Resolution: Flammable liquids moved to category 14 space with exception of daily use amounts found in small flammable liquid lockers.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 22 December 2010 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Trash cans marked as "Paper and Plastic" were found constructed of combustible materials (plastic) on deck 4 galley and in laundry room. SOLAS 2009Cons.Ed. CHII-2 Reg 4.4.2
Due 22 January 2011
Resolved 16 December 2011
Resolution: Verified non-combustible trash cans.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 22 December 2010 Resolved
Low Location lighting markings must enable passengers and crew to identify the routes of escape. Low location lighting on deck 4 by room 4300 is blocked by trash cans.SOLAS 74 2009 cons. CH II-2 Reg. 13.3.2.5.2 and 13.3.2.5.1
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 16 December 2011
Resolution: Trash cans removed from area.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 22 December 2010 Resolved
2240- Stowage- Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible materials providing storage for non hazardous safety equipment and open information counters are permitted. Excess stowage was located in stairwell by door 303. SOLAS 09 CH II-2 Reg 13 3.2.3
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 16 December 2011
Resolution: Stowage removed.
Fire Fighting › Means of Escape › Mimic Plans
Issued 22 December 2010 Resolved
0960- Means of escape- Above the bulkhead deck, there shall be at least two means of escape from each main vertical zone or similarly restricted space or groups of spaces, at least one of which shall give access to a stairway forming a main vertical zone. The linen locker (5d045) is being used as a office. SOLAS 2009 II-2 REG 13 2.2.2
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 30 December 2011
Resolution: Received e-mail from [name withheld] attesting to recategorization of space, installation of PA speaker within locker.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 22 December 2010 Resolved
2510- Safety and Environmental Policy- The Safety management system shall be maintained in accordance with the provisions of the ISM code. Found stowage in AC space rooms 201 and 404. Both spaces were clearly marked "No Stowage Allowed". SOLAS 2009 CH IX REG 5
Due 22 January 2011
Resolved 16 December 2011
Resolution: No stowage found in AC spaces.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 22 December 2010 Resolved
0750-Fire Prevention- Storage of combustibles materials is prohibited in spaces with a space categorization (10). Combustible materials were found in ventilation room deck 3 room 1103. SOLAS 74 (2009) II-2/9.2.2.3.2 (10)
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 16 December 2011
Resolution: Combustible materials were only stored in category 14 spaces with the exception of daily use amounts found in combustible liquid sotwage lockers.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 22 December 2010 Resolved
0721- Fixed fire extinguishing installation- Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler system complying with the requirements of the FSS code. Excessive Linen was found in a category 13 space (Laundry room deck 1 fwd) in a area where there was no sprinkler coverage. (Under Stairs) SOLAS 74 (2009) II-2/ Reg 10 6.1.1
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 16 December 2011
Resolution: Linen stowage was found only in spaces of adequate sprinkler coverage during exam.
Documentation › Safety/Response Plans/Programs
Issued 24 October 2002 Resolved
Provide Vessel Security Plan (VSP) to US Coast Guard Marine Safety Center prior to embarking passengers in the USA.
Due 31 May 2003
Resolved 27 May 2003
Resolution: VSP on board and valid Jan03.
Pollution Prevention/Response › Prevention Equipment
Issued 24 October 2002 Resolved
Weld closed containment within bunkering stations. Rat holes were found in both port and starboard bunkering stations. LEGACY COMPONENT DESC: Coamings
Condition: Improper Installation
Due 31 May 2003
Resolved 27 May 2003
Resolution: containment sealed.
Fire Fighting › Fire Pumps
Issued 24 October 2002 Resolved
Repair #2 local fire pump gauge. LEGACY COMPONENT DESC: Pressure
Due 31 May 2003
Resolved 27 May 2003
Resolution: Fire pump gauge operable
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 October 2002 Resolved
Deck 9 - frame 129 port side, remove key lock on door 902 going to stairs.
Condition: Unknown
Due 24 October 2002
Resolved 24 October 2002
Resolution: Observed removed.
Documentation › Manuals/Policy Documentation
Issued 24 October 2002 Resolved
Oil Transfer Procedures to be updated to P&O management style.
Due 31 May 2003
Resolved 27 May 2003
Resolution: OTP properly updated
Fire Fighting › Structural - A Class Divisions
Issued 24 October 2002 Resolved
Prove operation of FSD 316. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 31 May 2003
Resolved 27 May 2003
Resolution: FSD 316 operable
Fire Fighting › Ventilation Systems
Issued 24 October 2002 Resolved
Prove proper operation of the Hydraulic Room 3A047 vent diffuser. LEGACY COMPONENT DESC: Ducts
Due 24 October 2002
Resolved 24 October 2002
Electrical › Electric Supply System (service)
Issued 24 October 2002 Resolved
Properly terminate redundant cable at Embarkation Platform, port side, aft. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 31 May 2003
Resolved 27 May 2003
Resolution: Redundant cable properly terminated.
Accommodation/Occupational Safety
Issued 24 October 2002 Resolved
Reverse the muster station sign directional arrow located on Deck 9, Passenger Stairwell.
Due 31 May 2003
Resolved 27 May 2003
Resolution: Sign reversed.
Fire Fighting › Structural - A Class Divisions
Issued 24 October 2002 Resolved
Repair fire door 432 in way of the Main Galley. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 31 May 2003
Resolved 27 May 2003
Resolution: FD 432 operable
Accommodation/Occupational Safety › Occupational Safety
Issued 24 October 2002 Resolved
Repair the broken handle on the escape door at the AC Room, Deck 11 at approximately frame #32. 11A-14. LEGACY COMPONENT DESC: Hand Grab
Due 31 May 2003
Resolved 27 May 2003
Resolution: handle repaired
Fire Fighting › Structural - B Class Divisions
Issued 24 October 2002 Resolved
Provide Class approval certificate for B15 door between corridor and crew scullery, deck 3. LEGACY COMPONENT DESC: Openings - Doors
Due 24 October 2002
Resolved 24 October 2002
Resolution: Class approval rcvd.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 October 2002 Resolved
Remove all storage from Fan Rooms.
Due 31 May 2003
Resolved 27 May 2003
Resolution: no storage in Fan Rooms
Documentation › Markings/Placards
Issued 24 October 2002 Resolved
Re-write instructions for CO2 operation in all galleys so that they clearly show operation instructions.
Due 27 May 2003
Resolved 27 May 2003
Resolution: CO2 operation instructions clearly rewritten
Documentation › Markings/Placards
Issued 24 October 2002 Resolved
Provide instructions for CO2 operation in the BBQ Galley and Crew Galley - currently there are none.
Due 31 May 2003
Resolved 27 May 2003
Resolution: CO2 operation instructions posted.
Documentation › Certificates/Documents
Issued 24 October 2002 Resolved
All vessel certificates, logs, manuals are either expired and/or need Class approval and name change of Pacific Princess to be indicated; Provide current/valid/approved certificates, logs, and manuals.
Due 31 May 2003
Resolved 27 May 2003
Resolution: All valid with vessel name change approved
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 October 2002 Resolved
Prove operation of the low level lighting in the forward passenger stairway between deck 4 and 5.
Due 31 May 2003
Resolved 27 May 2003
Resolution: Low level lighting operable
Operations/Management › Drills/Instruction
Issued 24 October 2002 Resolved
Conduct fire and abandon ship drills upon arrival in US port. Included in the abandon ship drill: Conduct one life raft deployment.
Due 31 May 2003
Resolved 27 May 2003
Resolution: Fire and abandon ship drills satisfactory
Communications › Radio Communications › EPIRB
Issued 24 October 2002 Resolved
Verify EPIRB registration.
Due 24 October 2002
Resolved 24 October 2002
Resolution: EPIRB registered.
Navigation › Piloting/Steering
Issued 24 October 2002 Resolved
Provide new compass deviation card that is current since departing drydock in Singapore (1Nov02). LEGACY COMPONENT DESC: Deviation Table/Graph
Due 31 May 2003
Resolved 27 May 2003
Resolution: New compass deviation card posted
Navigation › Piloting/Steering
Issued 24 October 2002 Resolved
Verify accuracy of port steering flat gyro repeater. LEGACY COMPONENT DESC: Gryo Compass Repeater
Due 24 October 2002
Resolved 24 October 2002
Resolution: Accuracy verified.
Navigation › Collision/Grounding Avoidance
Issued 24 October 2002 Resolved
Provide ARPA label on ARPA radar. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Due 24 October 2002
Resolved 24 October 2002
Resolution: Label provided.
Lifesaving › Line-Throwing Appliances
Issued 24 October 2002 Resolved
Verify issue date of line throwing device.
Due 24 October 2002
Resolved 24 October 2002
Resolution: issue date verified to be current.
Documentation › Safety/Response Plans/Programs
Issued 24 October 2002 Resolved
Inaccurate Fire Control Plan for the Engine Room space; Re-verify engine room space and provide updated Fire Control Plan. LEGACY COMPONENT DESC: Fire Control Plans
Due 31 May 2003
Resolved 27 May 2003
Resolution: Fire Control Plan updated.
Lifesaving › Embarkation Appliances/Stations
Issued 24 October 2002 Resolved
Tender vessel pontoon doors- Remove the plaque "do not open without Staff Captain's permission' and provide correct plaque.
Due 24 October 2002
Resolved 24 October 2002
Resolution: Proper plaque provided.
Engineering › Bilge Water Management System
Issued 24 October 2002 Resolved
Repair dirty bilge pump discharge gauge. LEGACY COMPONENT DESC: Pump
Due 31 May 2003
Resolved 27 May 2003
Resolution: repaired
Engineering
Issued 24 October 2002 Resolved
Refasten all floorplates in engine room.
Due 31 May 2003
Resolved 27 May 2003
Resolution: refastened
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 October 2002 Resolved
Renew broken hand rail in chiller room.
Due 24 October 2002
Resolved 24 October 2002
Resolution: Hand rail renewed.
Fire Fighting › Structural - A Class Divisions
Issued 24 October 2002 Resolved
Ensure proper penetrations through all Water tight bulkheads in Engine room. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Due 31 May 2003
Resolved 27 May 2003
Resolution: Water tight bulkheads in tact.
Engineering
Issued 24 October 2002 Resolved
Free up all counter flooding devices, for sounding pipes, in engine room.
Due 24 October 2002
Resolved 24 October 2002
Resolution: Devices were freed up.
Fire Fighting › Automatic Sprinkler System › Sprinkler Grouping
Issued 24 October 2002 Resolved
Deck 10, Hold Bar (specialty restaurant). Provide sprinkler in locker behind bar, or demonstrate taht existing sprinklers provide adequate coverage.
Due 24 October 2002
Resolved 24 October 2002
Resolution: Adequate coverage demonstrated. Corrected on the spot.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 24 October 2002 Resolved
Pool BBQ - Remove doors and hinges to the lockers on the cooking appliances. Lower dedicated sprinkler heads below the recess and ceiling.
Due 24 October 2002
Resolved 24 October 2002
Resolution: Doors/hinges removed. Sprinkler heads properly relocated. Corrected on the spot.
Fire Fighting › Automatic Sprinkler System
Issued 24 October 2002 Resolved
Pool BBQ - Provide cover for the deep fat fryer or install directional sprinkler head that will direct water spray away from oil and towards the door. LEGACY COMPONENT DESC: Sprinkler Grouping
Due 31 May 2003
Resolved 27 May 2003
Resolution: Cover provided and directional sprinkler installed
Fire Fighting › Combustible Materials
Issued 24 October 2002 Resolved
Spa Reception Area - Remove storage/shelving area beneath counter.
Due 31 May 2003
Resolved 27 May 2003
Resolution: storage removed.
Fire Fighting › Combustible Materials
Issued 24 October 2002 Resolved
Deck 4 - Reception / Excursion areas. Floor to deck head cupboards to be removed. Remove drop box from excursion area.
Due 31 May 2003
Resolved 27 May 2003
Resolution: drop box removed
Fire Fighting › Means of Escape
Issued 24 October 2002 Resolved
Deck 5 - Remove lock from FWD mooring deck escape. LEGACY COMPONENT DESC: Doorways
Due 24 October 2002
Resolved 24 October 2002
Resolution: Lock removed. Corrected on the spot.
Fire Fighting › Fire Hydrants
Issued 24 October 2002 Resolved
Remove muster station equipment from Fire Station located Stbd side in Theater. LEGACY COMPONENT DESC: Location/Position
Due 24 October 2002
Resolved 24 October 2002
Resolution: Corrected on the spot.
Fire Fighting › Combustible Materials
Issued 24 October 2002 Resolved
Deck 4 - Electrical locker Stbd. side, outside FWD passenger stair - remove shelving from frame #122 - #125.
Due 24 October 2002
Resolved 24 October 2002
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions
Issued 24 October 2002 Resolved
Prove correct operations of the following FSD's (doors were not indicating as closed). 1001, 903, 904, 508, 506, 523, 432, 14, 408, 371, 334, 316, 313, 310, 309, 202, and splash door #310. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 31 May 2003
Resolved 27 May 2003
Resolution: All FSD''s indicated above operable
Fire Fighting › Automatic Sprinkler System
Issued 24 October 2002 Resolved
Conduct operational test of newly installed Water Mist system in a machinery space. LEGACY COMPONENT DESC: Testing Switches (Alarm/Sprinklers)
Due 31 May 2003
Resolved 27 May 2003
Resolution: Water Mist sysem operable
Fire Fighting › Automatic Sprinkler System
Issued 24 October 2002 Resolved
Clear system faults (due to drydockinng work) on sprinkler system monitoring panel. System faults during drydocking were Section - 21 Valves # 2 and 18, Section - 22 Valves # 7 and 19, and Section - 24 Valve # 11.
Due 31 May 2003
Resolved 27 May 2003
Resolution: System faults cleared.
Fire Fighting › Automatic Sprinkler System
Issued 24 October 2002 Resolved
Prove proper operation of the Zone Indication on the sprinkler board (sprinkler system indicator panel on the bridge). LEGACY COMPONENT DESC: Testing Switches (Alarm/Sprinklers)
Due 31 May 2003
Resolved 27 May 2003
Resolution: operable
Fire Fighting › Automatic Sprinkler System
Issued 24 October 2002 Resolved
Prove proper operaion of Sprinkler Section # 21. LEGACY COMPONENT DESC: Sprinklers
Due 31 May 2003
Resolved 27 May 2003
Resolution: operable

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.