MAURY USCG vessel records
← All vessels

CREW RUNNER

CREW RUNNER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in May 2026, along with 31 deficiencies and 1 casualty investigation in 2005.

Records from 2005 to 2026. Most recent: inspection, 8 May 2026.

Built
1978
Last inspected
8 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ9749
Flag
UNITED STATES
Maury page id
psix-49893

Documentation record

Registered dimensions (L × B × D)61.3 ft × 17.0 ft × 7.7 ft
Registered tonnagegross 57 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

8 May 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8369346
3 June 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8151268
22 October 2024 Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8012413
12 March 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7819169
7 October 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7573482
24 August 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7542910
24 August 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7275262
27 October 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7076279
6 May 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6931432
15 March 2019 COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6643404
23 November 2018 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6585523
5 July 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6457563
20 April 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6126113
16 August 2016 Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5968449
26 May 2016 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5885279

Deficiency record · 31

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 June 2025 Resolved
The person in command of a documented vessel must have on board that vessel the original certificate of documentation currently in effect for that vessel. Certificate of documentation on board is a copy. Provide original before operating. 46 CFR 67.313
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2025
Resolution: Vessel provided original COD onboard and placed in documents folder, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 March 2024 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. 46 cfr 176.500
Action required: 10 - Deficiency Rectified
Due 12 March 2024
Resolved 12 March 2024
Resolution: Conducted annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 August 2021 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in §176.500(b)(1) and your Certificate of Inspection must be endorsed. The annual inspection was to be conducted by no later than August 2, 2021 to remain valid but the inspection not completed until August 24, 2021. 46 CFR 176.502
Action required: 10 - Deficiency Rectified
Resolved 24 August 2021
Resolution: An Annual Inspection was completed on August 24, 2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 August 2021 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. A weeping fuel connection was observed on the #4 cylinder injector for the generator, additionally the lagging on the exhaust was deteriorated. Correct to the satisfaction of the attending Marine Inspector. 46 CFR 182.10-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 August 2021
Resolution: The fuel line was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 August 2021 Resolved
Inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Inspection records of the vessel's life-saving appliances were not onboard. 46 CFR 185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Vessel rep proivided proof of lifesaving equipment checks.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 24 August 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2021
Resolution: Vessel rep provided copy of Captain's FCC Radio Operators Permit.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 24 August 2021 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The hot water heater tank is severely wasted, remove from service. 46 CFR 182.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: The hot water heater tank was replaced.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 24 August 2021 Resolved
Placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Garbage placards posted depicted obsolete garbage discharge standards. 33 CFR 159.59(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: New garbage placard posted with current garbage discharge standards.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 August 2021 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] end wires were observed coming out of the "stove disconnect" box in the crew accommodations. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: "stove disconnect" was removed and wire was mounted within a junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 August 2021 Resolved
All electrical installations shall be to the satisfaction of the OCMI. The 240 V distribution panel on the bridge has a 50 amp breaker installed for the A/C unit but not labeled and the panel cover is unable to close. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Breaker panel was relabeled to include the 50 amp beaker for the A/C unit and panel door functions properly.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 24 August 2021 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable marine sanitation device (MSD). No chemical treatment products were available for the MSD to operate properly. 33 CFR 159.7
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Chemical treatment tabs were placed onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 August 2021 Resolved
Fuel shutoff valves shall be installed the tank connection. The aft fuel tank is no longer in-service, remove signage for the aft fuel tank emergency fuel shutoff on the main deck. 46 CFR 182.40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2021
Resolution: Remote fuel shutoff reach-rod and signage removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 August 2021 Resolved
The Master of the vessel must ensure that all of the provisions of the Certificate of Inspection are strictly adhered to. The flooring in the aft starboard corner of the passenger seating area is rotting and weakening the flooring. 46 CFR 185.20-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 September 2021
Resolution: 02 sections of flooring were replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2020 Resolved
All pressure vessels must be provided with protective devices. The vessel's hot water heater's pressure/temperature relief valve was inoperable. Rectify prior to use of the hot water heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted video of properly functioning relief valve.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 October 2020 Resolved
Piping including valves, pipe fittings, and flanges conveying vapor, gas, or liquid, the temperature of which exceeds 150 degree F must be suitably insulated where necessary to prevent injury. The insulation on both MDEs and Generator were wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate insulation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
If electrical equipment is utilized in a space in which the equipment's rated ambient temperature is below the assumed ambient temperature of the space (50 degrees C), its load must be derated. Vessel's generator data plate had an ambient temperature rating of 40 degrees C. Provide new data plate for an ambient temperature of 50 degrees C or derate the generator to adhere to the above regulation prior to use of the generator.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 8 December 2020
Resolution: Receieved, reviwed, and accepted generator data plate notating an ambient operating temperature of 50 degrees celsius.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
Each generator must meet the applicable construction and test requirements of Section 35 of the American Bureau of Shipping's "Rules for Building and Classing Steel Vessels". Vessel's generator windings were dirty with oil soaked dust. Rectify before use of generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of cleaned generator windings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 October 2020 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to salt water, petroleum oils and vibration. Vessel's fuel line on the generator was wasted. Replace fuel line prior to use of the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of new installation of fuel line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping metal objects across the terminal. Vessel's starboard engine batteries were not suitably covered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate battery covers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2020 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. 02 ends of of 02 vent pipes were torn and ineffective for intended use.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate flame screens.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2020 Resolved
The exhaust piping shall be so arranged as to prevent backflow of water from reaching engine exhaust ports under normal conditions. The vessel's starboard engine exhaust had no backflow protection rectify prior to use of starboard engine
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate exhaust backflow protection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Vessel had multiple openings in watertight bulkheads that were not water tight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation that all watertight bulkheads were made water tight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Vessel's light in the lazarette space was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of functioning light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Veesel's generator control box was not adequately mounted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation that generator control box was properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 October 2020 Resolved
A hatch exposed to the weather must be watertight. Vessels starboard engine room access had a wasted gasket.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation that engine room door gasket was satisfactorily replaced.
Lifesaving › Lifefloat › Painter
Issued 20 April 2017 Resolved
Replace electrical tape on lines for life floats and lights with more suitable ties to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 20 April 2017
Resolution: Received pictures showing electrical tape has been removed and lines are secured with quick release ties.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 26 May 2016 Resolved
Missing x2 type BII Fire Extinguishers. Corrected on the spot.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 26 May 2016
Resolution: Added missing fire extinguishers.
Lifesaving › Lifefloat › Float-free Link
Issued 26 May 2016 Resolved
Life Float not connected to weak link/spool. Corrected on the spot.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 26 May 2016
Resolution: Properly attached lifefloat to weak link and spool.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 May 2016 Resolved
Exhaust insulation on generator shows signes of exhaust leak. Repair effected area to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 31 May 2016
Resolution: Exhaust lagging on generator was replaced. No evidence of continuing leak.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 May 2016 Resolved
Certificate of Documentation expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 27 May 2016
Resolution: Placed current COD on board that was issued in Feb 2016.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 May 2016 Resolved
Mast Light missing nonreflective flat black back.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 31 May 2016
Resolution: Background for mast light was painted nonreflective flat black.

Casualty record · 1

8 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2360551
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.