CREW RUNNER

CREW RUNNER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1985, most recently in May 2026, along with 59 deficiencies and 1 casualty investigation in 2005.

Records from 1985 to 2026. Most recent: inspection, 8 May 2026.

Built
1978
Last inspected
8 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9749
Flag
UNITED STATES
368473910
Maury page id
psix-49893

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1985–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.3 ft × 17.0 ft × 7.7 ft
Registered tonnagegross 57 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9749MMSI 368473910 · active · compulsorily equipped · granted 14 May 2026, expires 14 May 2036
WDI3012MMSI 367684080 · expired · compulsorily equipped · granted 16 July 2015, cancelled 23 August 2025
WSJ6693MMSI 367007840 · expired · compulsorily equipped · granted 4 January 2005, cancelled 23 May 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 53

8 May 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8369346
3 June 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8151268
22 October 2024 Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8012413
12 March 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7819169
7 October 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7573482
24 August 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7542910
24 August 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7275262
27 October 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7076279
6 May 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6931432
15 March 2019 COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6643404
23 November 2018 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6585523
5 July 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6457563
20 April 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6126113
16 August 2016 Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5968449
26 May 2016 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5885279
8 August 2014 Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4940781
25 March 2014 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4818903
4 February 2010 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3673393
26 March 2009 COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3438407
29 July 2008 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3277550
25 March 2008 Administrative Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3167542
3 July 2007 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2980653
5 May 2006 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2641387
28 March 2006 Annual Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2610923
29 July 2005 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2441800
8 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2360551
3 June 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2087178
3 May 2004 COI Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2057975
20 September 2002 Annual Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1676113
13 June 2002 Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1630359
12 December 2001 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1476446
11 December 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 772732
28 September 2000 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365973
21 December 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404885
19 February 1999 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473204
1 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 769663
30 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 190112
12 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431929
28 January 1997 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400484
6 February 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1353867
18 January 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409227
18 March 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 466486
20 October 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 825930
10 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 836706
15 October 1992 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257888
24 January 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909276
7 September 1990 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906307
31 March 1989 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352894
23 November 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897439
28 February 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333658
29 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019406
24 February 1987 Hull Examination · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014211
13 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287069

Deficiency record · 59

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 June 2025 Resolved
The person in command of a documented vessel must have on board that vessel the original certificate of documentation currently in effect for that vessel. Certificate of documentation on board is a copy. Provide original before operating. 46 CFR 67.313
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2025
Resolution: Vessel provided original COD onboard and placed in documents folder, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 March 2024 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. 46 cfr 176.500
Action required: 10 - Deficiency Rectified
Due 12 March 2024
Resolved 12 March 2024
Resolution: Conducted annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 August 2021 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in §176.500(b)(1) and your Certificate of Inspection must be endorsed. The annual inspection was to be conducted by no later than August 2, 2021 to remain valid but the inspection not completed until August 24, 2021. 46 CFR 176.502
Action required: 10 - Deficiency Rectified
Resolved 24 August 2021
Resolution: An Annual Inspection was completed on August 24, 2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 August 2021 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. A weeping fuel connection was observed on the #4 cylinder injector for the generator, additionally the lagging on the exhaust was deteriorated. Correct to the satisfaction of the attending Marine Inspector. 46 CFR 182.10-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 August 2021
Resolution: The fuel line was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 August 2021 Resolved
Inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Inspection records of the vessel's life-saving appliances were not onboard. 46 CFR 185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Vessel rep proivided proof of lifesaving equipment checks.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 24 August 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2021
Resolution: Vessel rep provided copy of Captain's FCC Radio Operators Permit.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 24 August 2021 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The hot water heater tank is severely wasted, remove from service. 46 CFR 182.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: The hot water heater tank was replaced.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 24 August 2021 Resolved
Placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Garbage placards posted depicted obsolete garbage discharge standards. 33 CFR 159.59(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: New garbage placard posted with current garbage discharge standards.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 August 2021 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] end wires were observed coming out of the "stove disconnect" box in the crew accommodations. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: "stove disconnect" was removed and wire was mounted within a junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 August 2021 Resolved
All electrical installations shall be to the satisfaction of the OCMI. The 240 V distribution panel on the bridge has a 50 amp breaker installed for the A/C unit but not labeled and the panel cover is unable to close. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Breaker panel was relabeled to include the 50 amp beaker for the A/C unit and panel door functions properly.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 24 August 2021 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable marine sanitation device (MSD). No chemical treatment products were available for the MSD to operate properly. 33 CFR 159.7
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Chemical treatment tabs were placed onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 August 2021 Resolved
Fuel shutoff valves shall be installed the tank connection. The aft fuel tank is no longer in-service, remove signage for the aft fuel tank emergency fuel shutoff on the main deck. 46 CFR 182.40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2021
Resolution: Remote fuel shutoff reach-rod and signage removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 August 2021 Resolved
The Master of the vessel must ensure that all of the provisions of the Certificate of Inspection are strictly adhered to. The flooring in the aft starboard corner of the passenger seating area is rotting and weakening the flooring. 46 CFR 185.20-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 September 2021
Resolution: 02 sections of flooring were replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2020 Resolved
All pressure vessels must be provided with protective devices. The vessel's hot water heater's pressure/temperature relief valve was inoperable. Rectify prior to use of the hot water heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted video of properly functioning relief valve.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 October 2020 Resolved
Piping including valves, pipe fittings, and flanges conveying vapor, gas, or liquid, the temperature of which exceeds 150 degree F must be suitably insulated where necessary to prevent injury. The insulation on both MDEs and Generator were wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate insulation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
If electrical equipment is utilized in a space in which the equipment's rated ambient temperature is below the assumed ambient temperature of the space (50 degrees C), its load must be derated. Vessel's generator data plate had an ambient temperature rating of 40 degrees C. Provide new data plate for an ambient temperature of 50 degrees C or derate the generator to adhere to the above regulation prior to use of the generator.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 8 December 2020
Resolution: Receieved, reviwed, and accepted generator data plate notating an ambient operating temperature of 50 degrees celsius.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
Each generator must meet the applicable construction and test requirements of Section 35 of the American Bureau of Shipping's "Rules for Building and Classing Steel Vessels". Vessel's generator windings were dirty with oil soaked dust. Rectify before use of generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of cleaned generator windings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 October 2020 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to salt water, petroleum oils and vibration. Vessel's fuel line on the generator was wasted. Replace fuel line prior to use of the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of new installation of fuel line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping metal objects across the terminal. Vessel's starboard engine batteries were not suitably covered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate battery covers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2020 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. 02 ends of of 02 vent pipes were torn and ineffective for intended use.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate flame screens.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2020 Resolved
The exhaust piping shall be so arranged as to prevent backflow of water from reaching engine exhaust ports under normal conditions. The vessel's starboard engine exhaust had no backflow protection rectify prior to use of starboard engine
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of adequate exhaust backflow protection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Vessel had multiple openings in watertight bulkheads that were not water tight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation that all watertight bulkheads were made water tight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Vessel's light in the lazarette space was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation of functioning light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Veesel's generator control box was not adequately mounted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation that generator control box was properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 October 2020 Resolved
A hatch exposed to the weather must be watertight. Vessels starboard engine room access had a wasted gasket.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 November 2020
Resolution: Received, reviewed, and accepted documentation that engine room door gasket was satisfactorily replaced.
Lifesaving › Lifefloat › Painter
Issued 20 April 2017 Resolved
Replace electrical tape on lines for life floats and lights with more suitable ties to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 20 April 2017
Resolution: Received pictures showing electrical tape has been removed and lines are secured with quick release ties.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 26 May 2016 Resolved
Missing x2 type BII Fire Extinguishers. Corrected on the spot.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 26 May 2016
Resolution: Added missing fire extinguishers.
Lifesaving › Lifefloat › Float-free Link
Issued 26 May 2016 Resolved
Life Float not connected to weak link/spool. Corrected on the spot.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 26 May 2016
Resolution: Properly attached lifefloat to weak link and spool.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 May 2016 Resolved
Exhaust insulation on generator shows signes of exhaust leak. Repair effected area to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 31 May 2016
Resolution: Exhaust lagging on generator was replaced. No evidence of continuing leak.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 May 2016 Resolved
Certificate of Documentation expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 27 May 2016
Resolution: Placed current COD on board that was issued in Feb 2016.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 May 2016 Resolved
Mast Light missing nonreflective flat black back.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 31 May 2016
Resolution: Background for mast light was painted nonreflective flat black.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 March 2014 Resolved
Provide Documentation fire and abandoned ship drills are being conducted at quarterly intervals.
Action required: 705 - Other - as specified
Due 8 April 2014
Resolved 3 April 2014
Resolution: Attended vessel and noted logs had been updated to contain 2 drills in addition to conducting a drill while CG inspector was onboard.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 25 March 2014 Resolved
Vent pipe for diesel fuel tank is cracked. Fix crack on vent tube.
Action required: 705 - Other - as specified
Due 8 April 2014
Resolved 3 April 2014
Resolution: Vent tube had been gouged and rewelded so that a crack was no longer there.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 March 2014 Resolved
Ensure that water heater is properly secured and that wiring is properly covered.
Action required: 705 - Other - as specified
Due 8 April 2014
Resolved 4 April 2014
Resolution: Verified that electrical panel on the heater was covered and that the heater was secured.
Engineering › Bilge Water Management System › Pump
Issued 25 March 2014 Resolved
Provide a central control point and light for powered bilge pump.
Action required: 705 - Other - as specified
Due 8 April 2014
Resolved 3 April 2014
Resolution: Verified that switch and light for the bilge pump had been installed in the engine room. Ran bilge pump to verify that system was operational.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 4 February 2010 Resolved
Provide Marine Radio Operator's permit for master [name withheld] #1128875 and provide proof to the [name withheld].
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 1 March 2010
Navigation › Piloting/Steering › Marine Charts
Issued 4 February 2010 Resolved
Provide all charts and nav pubs for operational area.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 February 2010 Resolved
Provide EAP information in accordance with 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 February 2010 Resolved
Provide "not under command" lights and day shapes.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 February 2010 Resolved
Provide proof of fire extinguisher maintenance.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 4 February 2010 Resolved
Provide and install Engine Room globe and guard.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 4 February 2010 Resolved
Provide valve handle for the Forepeak bilge suction.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 February 2010 Resolved
Provide emergency instructions in accordance with 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 23 February 2010
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 26 March 2009 Resolved
Excess oil build-up in Generator Set windings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 31 March 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 July 2007 Resolved
Provide valid COD (one on board was expired).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 July 2007 Resolved
Install required line on ring buoy.
Due 3 August 2007
Resolved 10 July 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 July 2007 Resolved
Prove proper operation of vent closures.
Due 3 August 2007
Resolved 10 July 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 3 July 2007 Resolved
Install flame screen on fuel vent.
Due 3 August 2007
Resolved 10 July 2007
Stability › Watertight Integrity › Weathertight Enclosure
Issued 3 July 2007 Resolved
Install bolts and gaskets for engine room covers.
Due 3 August 2007
Resolved 10 July 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 July 2007 Resolved
Install double hose clamp on fuel hose in lazarette.
Due 3 August 2007
Resolved 10 July 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 July 2007 Resolved
Install double hose clamp on generator exhaust hose in lazarette.
Due 3 August 2007
Resolved 10 July 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 July 2007 Resolved
Install double hose clamps on sea water supply system in engine room.
Due 3 August 2007
Resolved 10 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007 Resolved
Terminate open-end white wire on inboard side of starboard MDE.
Due 3 August 2007
Resolved 10 July 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 July 2007 Resolved
Install chaffing gear where hose meets generator belt guard.
Due 3 August 2007
Resolved 10 July 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 July 2007 Resolved
Provide battery terminal covers for all batteries.
Due 3 July 2007
Resolved 10 July 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 July 2007 Resolved
Install shaft guard on port & starboard MDEs. Ensure guards are the correct size.
Due 3 August 2007
Resolved 10 July 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 3 July 2007 Resolved
Replace cracked window in port side of pilothouse.
Due 3 August 2007
Resolved 10 July 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 3 July 2007 Resolved
Secure valve for MSD overboard discharge.
Due 3 August 2007
Resolved 10 July 2007
Documentation
Issued 15 October 1992 Resolved
PROVIDE PROOF OF STABILITY OR DOCUMENTATION SHOWING EVIDENCE OF TOTAL NUMBER OF PEOPLE CARRIED FOR DETERMINING SATISFACTORY STABILITY IN SERVICE,OR MAKE VESSEL AVAILABLE FOR A SIMPLIFIED STABILITY TEST IN ACCORDANCE WITH46 CFR 170.120 (B) AND 46 CFR 170.160 (B).
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992

Casualty record · 1

8 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2360551
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.