MAURY USCG vessel records Sign in
← All vessels

TRISTAN JANICE

TRISTAN JANICE is a 1978 offshore supply vessel. The Coast Guard has recorded 46 inspections since 1980, most recently in April 2017, along with 62 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2014.

Records from 1980 to 2017. Most recent: inspection, 26 April 2017.

Built
1978
Last inspected
26 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC3975
Flag
UNITED STATES
366891270, 367017280 (licence lapsed)
Maury page id
psix-49894

Inspections, by type

…with no type recorded13
Years with a record 30 calendar years (1980–2017)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC3975MMSI 367017280 · expired · compulsorily equipped · granted 7 February 2015, cancelled 12 April 2025
WDB3787MMSI 366891270 · expired · compulsorily equipped · granted 25 April 2003, cancelled 29 June 2013 · licensed under a name not among this hull’s recorded names (not shown)
WUW9099MMSI not assigned · expired · compulsorily equipped · granted 11 June 1998, cancelled 22 November 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

26 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132947
7 May 2014 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4851674
23 January 2012 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4228479
4 January 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4217532
21 December 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3913795
14 December 2009 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3648569
5 January 2009 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3388567
24 January 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3135509
5 February 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867417
11 January 2007 COI Inspection · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2860528
13 February 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2584145
16 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2515447
9 October 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2521335
22 February 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2289482
15 October 2004 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2223313
20 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759672
17 December 2001 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1476237
31 August 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116807
31 August 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409954
9 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665669
23 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14440
27 August 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394820
12 December 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762144
5 December 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194056
28 August 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433096
22 August 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434294
22 August 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392052
27 July 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 665666
24 July 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 55182
13 July 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391873
16 July 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461481
30 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 145814
12 August 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932360
12 August 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248471
28 February 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930430
13 July 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222032
11 September 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200519
21 July 1989 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199484
13 July 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032639
16 July 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337659
10 July 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986517
19 November 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292704
17 October 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992092
30 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969339
10 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971105
26 September 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968579

Deficiency record · 62

Operations/Management › Drills/Instruction › Not Conducted
Issued 7 May 2014 Resolved
Complete annual inspection prior to operating vessel. See activity 4851674 for details.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2014
Communications › Radio Communications › Satellite Communications Capability
Issued 23 January 2012 Resolved
Single Side Band radio not on 12 VDC emergency supply. Vessel shall repair/replace to origninal condition.
Action required: 705 - Other - as specified
Due 30 January 2012
Resolved 30 January 2012
Resolution: Received 3rd party certificate for SSB radio operational test.
Communications › Internal Communications System › Sound-powered Telephone
Issued 23 January 2012 Resolved
Engine Room missing sound powered telephone or voice tube capability IAW 46 CFR 113.30-5(a) and 46 CFR 113.30-25(d).
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 10 February 2012
Resolution: Visually inspected and tested sound powered phone from engine room.
Engineering › Fuel Oil Service System › Valve
Issued 21 December 2010 Resolved
Demonstrate proper operation of fuel emergency shutoff
Action required: 705 - Other - as specified
Resolved 22 December 2010
Construction/Loadline › Structures › Superstructure
Issued 21 December 2010 Resolved
Replace broken window aft on bridge
Action required: 705 - Other - as specified
Resolved 22 December 2010
Communications › Radio Communications › Emergency Source of Power
Issued 21 December 2010 Resolved
Demonstrate proper operation of SSB on backup power.
Action required: 705 - Other - as specified
Resolved 22 December 2010
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 21 December 2010 Resolved
Label instructions at emergency steering
Action required: 705 - Other - as specified
Resolved 22 December 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 December 2010 Resolved
Provide guard for rotating machinery on stbd MDE
Action required: 705 - Other - as specified
Resolved 22 December 2010
Communications › Alarms/Indicators › Fire Alarm
Issued 14 December 2009 Resolved
Remount all fire alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2009
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 14 December 2009 Resolved
Clean both generator armatures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 December 2009 Resolved
Repalce blank in engine room switchboard
Due 21 December 2009
Resolved 15 December 2009
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 14 December 2009 Resolved
Adjust port generator overspeed & test for marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2009
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 December 2009 Resolved
Replace & double clamp stbd/port MDE expansion tank hoses.
Due 21 December 2009
Resolved 15 December 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 14 December 2009 Resolved
Install valve between PVC washer drain pipe & steel sewage dischage pipe.
Due 14 January 2010
Resolved 15 December 2009
Electrical › Electric Supply System (service) › Cable
Issued 14 December 2009 Resolved
Renew port MDE emergency shutdown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2009
Lifesaving › Lifebuoys › Serviceable
Issued 14 December 2009 Resolved
Renew 3 life rings
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 January 2009 Resolved
Demonstrate proper operation of Engine Stops.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2009
Engineering › Fuel Oil Service System › Vent Pipe
Issued 5 January 2009 Resolved
Install vent screen for Port Fuel Tank Vent
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2009
Navigation › Piloting/Steering › Marine Charts
Issued 5 January 2009 Resolved
Provide approach charts for areas of operation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2009
Communications › Radio Communications › EPIRB
Issued 5 January 2009 Resolved
1) Provide new Hydro-Release for EPIRB 2) Log EPIRB Testing in Official Log Monthly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 January 2009 Resolved
Install Engine Guards on Port and Stbd Main Engines
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 January 2008 Resolved
Remove collected excess oil from bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Lifesaving › Lifebuoys › Serviceable
Issued 24 January 2008 Resolved
Replace three lifebuoys on deck as directed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 January 2008 Resolved
Properly label "Emergency Exit - Keep Clear" on two exits as directed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 24 January 2008 Resolved
Provide a means to keep clothes washing machine discharge water segregated from oily water in machinery bilges.
Due 24 February 2008
Resolved 25 January 2008
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 31 January 2007 Resolved
Vessel operated past its required hull exam date of 17NOV2006
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 31 January 2007 Resolved
Provide tech report for complete overhaul of port MDE & demonstrate proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 January 2007 Resolved
Provide proof of cew enrollment in drug consortia
Due 28 February 2007
Resolved 13 February 2007
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 31 January 2007 Resolved
Demonstrate proper operation of port generator with full ship's load and overspeed protection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 January 2007 Resolved
Install missing exhaust lagging
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 January 2007 Resolved
Install open/shut direction indicators for emergency fuel shutoffs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 31 January 2007 Resolved
Demonstrate proper operation of port ventalation covers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 31 January 2007 Resolved
Install missing blank at E/R switchboard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Construction/Loadline › Structures › Scuttle
Issued 31 January 2007 Resolved
Renew cracked emergency escape hatch & gasket material
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 31 January 2007 Resolved
Demonstrate satisfactory drills to marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2007
Resolved 13 February 2007
Stability › Incline Test › General
Issued 13 February 2006 Resolved
Provide stability information and draft marks to determine the safe loading of this vessel prior to vsl operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 14 February 2006
Resolution: Provided stability information and correct draft marks.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 13 February 2006 Resolved
Demonstrate proper operation of #2 generator and over speed trip prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 15 February 2006
Resolution: Demonstrated proper operation of over speed of generator.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 February 2006 Resolved
Provide coast pilot and light list prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 14 February 2006
Resolution: Provided required light list and coast pilot.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 February 2006 Resolved
Provide servicing info with location, serial # and type of inspection prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 14 February 2006
Resolution: Provided servicing certificate.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 February 2006 Resolved
Install corect lights to Nav lights prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 15 February 2006
Resolution: Installed correct bulbs.
Communications › Radio Communications › EPIRB
Issued 13 February 2006 Resolved
Renew antenna to EPIRB prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 15 February 2006
Resolution: Renewed EPIRB antenna, operation sat.
Lifesaving › Buoyant Apparatus › Float Free
Issued 13 February 2006 Resolved
Install wood slats between life floats prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 14 February 2006
Resolution: Provided and isntalled wood slats.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 13 February 2006 Resolved
Install electrical matte at switchboard prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2006
Resolved 14 February 2006
Resolution: Provided and isntalled mat.
Documentation › Certificates/Documents
Issued 20 March 2003 Resolved
Provide proof of a valid FCC station license. LEGACY COMPONENT DESC: FCC Station License
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Navigation › Piloting/Steering
Issued 20 March 2003 Resolved
Provide up-to-date tide and current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2003
Resolved 24 April 2003
Documentation › Logs/Records
Issued 20 March 2003 Resolved
Provide for the proper logging of pre-voyage checks and EPIRB tests. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Documentation › Manuals/Policy Documentation
Issued 20 March 2003 Resolved
Provide a waste management plan. LEGACY COMPONENT DESC: Waste Management Plan
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Documentation › Safety/Response Plans/Programs
Issued 20 March 2003 Resolved
Provide a Coast Guard approved fire and safety plan. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Operations/Management › Drills/Instruction
Issued 20 March 2003 Resolved
Provide an emergency broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Communications › Radio Communications
Issued 20 March 2003 Resolved
Have EPIRB serviced, renew battery. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2003
Resolved 24 April 2003
Engineering › Fuel Oil Service System
Issued 20 March 2003 Resolved
Remove petcocks from RAYCOR filters and install plugs or provide petcocks that accept a plug. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Electrical › Electrical Distribution System (service)
Issued 20 March 2003 Resolved
Repair and insure proper operation of all indicator lights on the switchboard. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Fire Fighting › Grease Extraction Hood
Issued 20 March 2003 Resolved
Provide a cover for the light on the range hood. LEGACY COMPONENT DESC: Light
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Construction/Loadline › Markings
Issued 20 March 2003 Resolved
Paint draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 April 2003
Construction/Loadline › Hull
Issued 7 January 2002 Resolved
REPAIRS TO NUMERUOUS TO MENTION. SEE ATTACHED PLATE SUMMARY ON FILE AT MORMS. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2002
Resolved 7 January 2002
Engineering
Issued 12 August 1991 Resolved
INSTALL MAIN ENGINE OVERSPEEDS PER ABS RULE 34.11.6. SEE ATTACHED LETTER FROM COMMANDANT 16703 DTD 18JUNE1989.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Engineering
Issued 13 July 1990 Resolved
INSTALL AND PROVE OPERATION OF MDE OVERSPEEDS.
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Documentation
Issued 21 July 1989 Resolved
PROVIDE STABILITY LETTER AS REQUIRED BY 46 CFR SUBCHAPTER "S".
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Navigation
Issued 21 July 1989 Resolved
MAKE REPAIRS TO SSB RADIO.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Unknown
Issued 17 October 1985 Resolved
PROVIDE DEVIATION CARD FOR MPG COMPRESS.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Unknown
Issued 17 October 1985 Resolved
MAKE NESS REPAIRS TO STBD S/S GENATOR OVERRSPEED TRIP.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Unknown
Issued 17 October 1985 Resolved
PROVIDE STALIBILTY BOOKLET AND TANK CAP TABLES AS REQ BY STALIBILTY LETTER DATED 03OCT78
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985

Casualty record · 2

9 October 2005Routine · role: Involved in a Marine Casualty · activity 2521335
18 February 2014Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4802348
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.