Inspection history · 19
17 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8187785
15 April 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8111538
14 May 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7911534
17 July 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7747557
25 April 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7677299
1 March 2023
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7642614
11 April 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7420111
5 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7189731
8 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7170880
23 June 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6984603
16 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6831341
24 April 2019
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669081
2 April 2019
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669783
20 April 2018
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395736
26 January 2018
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6344331
30 May 2017
Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6160508
9 September 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5996339
6 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5899469
10 May 2016
Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5873628
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 May 2024
Resolved
EPIRB battery dates not listed on device. Required proof of battery life or to obtain new prior to operating outside 3 NM.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 20 May 2024
Resolution: Owner purchased new EPIRB.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2023
Resolved
Vessels first aid kit missing items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2023
Resolved 18 May 2023
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 April 2023
Resolved
Vessel is required 02 IBA, vessel currently only has 01 as there is a back order nation wide. Issued 835v restricting pax count until both are on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 17 July 2023
Resolution: See narrative
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 April 2022
Resolved
Vessel only has one 10-man IBA onboard. Persons onboard reduced to 12 passengers & 2 crew till other 10-man IBA installed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 May 2022
Resolution: Second inflatable life raft installed on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 April 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properlyh protected by a cover, guard or rail. Install protective covering around pulleys on main diesel engines.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 11 May 2022
Resolution: Machinery guards installed
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 April 2022
Resolved
EPIRB must be installed to automatically float free and activate. Move EPIRB away from overhang & ladder.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 13 April 2022
Resolution: EPIRB moved
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 April 2022
Resolved
Coast Guard inspected small passenger vessels must be equipped with a VHF-DSC radio installation. Connect VHF radio to DSC. 47 CFR 80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 12 April 2022
Resolution: DSC installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2022
Resolved
Alcohol test swabs were expired. Replace with updated alcohol test swabs.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 12 April 2022
Resolution: Procured test swabs
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 11 April 2022
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and stern of the vessel. Mark port & starboard bow with vessel name.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 19 April 2022
Resolution: Name stenciled on p/s bow
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 April 2022
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 19 April 2022
Resolution: Placard installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2021
Resolved
Suitable guards and covers shall be installed in way of of all exposed and hazardous places such as gears, machinery, etc.. Mechanical guards required on port/starboard shafts and drive belts.
46CFR177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 13 May 2021
Resolution: Operator provided photo documentation of mechanical guards.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 5 May 2021
Resolved
Each disposable hydrostatic release unit must be marked with an expiration of two years. EPIRB hydrostatic release expired and requires replacement.
46CFR185.740
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 13 May 2021
Resolution: Operator provided photo documentation of installed hydrostatic release as well as expiration date marked out.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021
Resolved
Electrical equipment shall be installed and maintained to prevent electrical shock and hazards. Distribution circuit break panel located under interior stairs is not properly secured inside distribution box and front cover required attachment.
46CFR183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 6 May 2021
Resolution: Operator sent CG MI a picture and video of the repaired distribution box and door panel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Wire connections on P/STBD aft quarters under gunnel need to be made within an enclosure.
46CFR183.340(G)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 6 May 2021
Resolution: Operator sent pictures of installed waterproof enclosures to the CG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2020
Resolved
Vessels constructed of wood must provide bilge alarms watertight compartments, except in small buoyancy chambers. #2 void bilge alarm was inoperable.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2020
Resolved 24 June 2020
Resolution: Received satsifactory proof of fully operational #2 void bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 June 2020
Resolved
A marine employer whose vessel is involved in an incident or incident that is, or likely to become, a serious marine incident the marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel chemically tested. Vessel was missing 2 alcohol test strips and 01 was expired. 46 CFR 4.06-1.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Alcohol strips are ordered
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 June 2020
Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard, or rail. Both MDE's were missing guards on rotating gears.46 CFR 177.940
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Guards were replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020
Resolved
A vessel must carry one floating waterlight, unless it is limited to day-time operations. Vessel's waterlight was not attached to ring buoy. 46 CFR 180.70(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Waterlight attached to ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2020
Resolved
A vessel not required to have a power driven fire pump by 46 CFR 181.300 must have at least 3 2.5 gallon buckets, with an attached lanyard to the satisfaction of the cognizant OCMI and must be labeled “FIRE BUCKET” in contrasting colors. Vessel was missing fire buckets. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: 3 fire buckets were ourchased and on board
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2020
Resolved
Each connection to a conductor or terminal part must be made within an enclosure. All bilge wiring connections were not in an enclosure. 46 CFR 183.340(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Bilge wiring connections were in enclosed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2020
Resolved
Each life jacker carried on a vessel on oceasn, coastwise, or Great Lakes route must have a life jacket light. Vessel can operate as an unispected Passenger Vesel on an oceans route in accordance with current COI and must have lights on an 09 adult life jackets and 02 child life jackets. 46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Lights were added to lifejackets
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 September 2019
Resolved
Vessel owner had fabricated a box that held fishing rods for passengers and also provided protection for the glass hatch on the forward main deck. This hatch is the emergency escape hatch from the accommodation space and must be maintained accessible at all times.
Action required: 10 - Deficiency Rectified
Due 16 September 2019
Resolved 16 September 2019
Resolution: Vessel owner removed box.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 April 2019
Resolved
Vessel's power on indicating light is inoperable on the fire control panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 3 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 April 2019
Resolved
Vessel is missing its FCC Radio Safety Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 3 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 April 2019
Resolved
Vessel's navigational publications are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2019
Resolved
MI identified pvc piping in the generator's exhaust piping. Prior to operating generator, vessel needs to replace piping with authorized material.
Action required: 705 - Other - as specified
Resolved 3 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2019
Resolved
Provide safety guard on starboard main engine
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 3 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2019
Resolved
Mount high level bilge alarm located in the most fwd space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2019
Resolved
Provide portable hand bilge pump capable of pumping 5 gpm
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2019
Resolved
Vessels need to plug a hole in the fwd engine room bulkhead on the starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 April 2018
Resolved
Provide Light List and Coast Pilot.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 27 April 2018
Resolution: Provided evidence of rectification and receipt of purchase.
Communications › Radio Communications › EPIRB
Issued 20 April 2018
Resolved
Provide HRU for EPIRB.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 1 May 2018
Resolution: Provided evidence of rectification and receipt of purchase.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 June 2017
Resolved
Install exhust clamp on MDE exhust.
Condition: Improper/Lack of Maintenance
Due 15 July 2017
Resolved 23 April 2018
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 15 June 2017
Resolved
Adjust port stuffing box packing.
Due 15 July 2017
Resolved 23 April 2018
Resolution: Vessel has installed drip-less packing glands.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 June 2017
Resolved
Repair stern light.
Due 15 July 2017
Resolved 23 April 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 June 2016
Resolved
Label 12v breakers in rod room.
Due 6 July 2016
Resolved 9 September 2016
Engineering › Bilge Water Management System › Pump
Issued 6 June 2016
Resolved
Repair forepeak bilge pump float switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2016
Resolution: Bilge pump switch wiring repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 6 June 2016
Resolved
Shave transverse frame IWO port shaft so that shaft is not rubbing.
Due 6 July 2016
Resolved 9 September 2016
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 6 June 2016
Resolved
Secure cable harness above starboard MDE.
Due 6 June 2016
Resolved 9 September 2016
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 June 2016
Resolved
Remove spring clamps on battery charger.
Due 6 July 2016
Resolved 9 September 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 June 2016
Resolved
Provide outlet for freezer in rod room.
Due 6 July 2016
Resolved 10 June 2016
Resolution: Outlet provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2016
Resolved
Provide guard for starboard MDE pulleys.
Due 6 July 2016
Resolved 9 September 2016