← All vessels

CRUNCH TIME

CRUNCH TIME is a 1978 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1984, most recently in July 2025, along with 110 deficiencies and 1 operational control.

Records from 1984 to 2025. Most recent: inspection, 17 July 2025.

Built
1978
Last inspected
17 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN 7594
Flag
UNITED STATES
368025190, 368245610
Maury page id
psix-49895

Inspections, by type

…with no type recorded4
Years with a record 38 calendar years (1984–2025)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 16.9 ft × 8.2 ft
Registered tonnagegross 37 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE BROS · HARKERS ISLAND, NC, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN7594MMSI 368245610 · active · compulsorily equipped · granted 25 April 2023, expires 25 April 2033
WDM8688MMSI 368245610 · cancelled · compulsorily equipped · granted 22 March 2022, cancelled 21 April 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDJ9349MMSI 368025190 · active · compulsorily equipped · granted 2 March 2018, expires 2 March 2028 · licensed under a name not among this hull’s recorded names (not shown)
WDE5286MMSI 367364430 · expired · compulsorily equipped · granted 21 June 2008, cancelled 25 August 2018 · licensed under a name not among this hull’s recorded names (not shown)
WSY8907MMSI 366973610 · expired · compulsorily equipped · granted 24 August 2004, cancelled 25 October 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

17 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8187785
15 April 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8111538
14 May 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7911534
17 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7747557
25 April 2023 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7677299
1 March 2023 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7642614
11 April 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7420111
5 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7189731
8 April 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7170880
23 June 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6984603
16 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6831341
24 April 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669081
2 April 2019 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669783
20 April 2018 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395736
26 January 2018 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6344331
30 May 2017 Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6160508
9 September 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5996339
6 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5899469
10 May 2016 Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5873628
18 March 2014 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4818026
18 May 2012 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4314868
24 March 2010 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3703305
1 April 2009 Simplified Stability Test
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3444382
8 January 2009 COI Inspection · In-Service Inspection · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3390738
8 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3292639
12 May 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3204408
29 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3138441
16 January 2008 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3131204
25 April 2006 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2632415
18 January 2005 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2275119
21 May 2004 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2064162
2 January 2004 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1966208
22 December 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1967444
22 January 2003 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1733302
14 May 2002 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1613629
24 October 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1428100
12 October 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1405060
31 May 2000 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1460425
14 April 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1410295
24 September 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1418599
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 796599
22 February 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1462722
7 January 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 810427
15 October 1998 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801756
29 May 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127089
15 October 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 775408
2 October 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 837370
30 May 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084231
24 October 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184205
20 October 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864858
31 May 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1178569
5 October 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143479
27 October 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252657
27 May 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269996
8 May 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259757
14 November 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265463
3 October 1990 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242955
28 June 1990 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223891
10 October 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196044
2 June 1989 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886499
1 June 1989 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346111
7 December 1988 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199140
1 November 1988 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039499
8 October 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012331
21 January 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013416
7 January 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013256
31 October 1986 Drydock Extension · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332844
29 October 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304683
3 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289025
10 October 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 974515
10 October 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1282507

Deficiency record · 110

05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 May 2024 Resolved
EPIRB battery dates not listed on device. Required proof of battery life or to obtain new prior to operating outside 3 NM.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 20 May 2024
Resolution: Owner purchased new EPIRB.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2023 Resolved
Vessels first aid kit missing items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2023
Resolved 18 May 2023
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 April 2023 Resolved
Vessel is required 02 IBA, vessel currently only has 01 as there is a back order nation wide. Issued 835v restricting pax count until both are on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 17 July 2023
Resolution: See narrative
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 April 2022 Resolved
Vessel only has one 10-man IBA onboard. Persons onboard reduced to 12 passengers & 2 crew till other 10-man IBA installed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 May 2022
Resolution: Second inflatable life raft installed on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 April 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properlyh protected by a cover, guard or rail. Install protective covering around pulleys on main diesel engines.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 11 May 2022
Resolution: Machinery guards installed
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 April 2022 Resolved
EPIRB must be installed to automatically float free and activate. Move EPIRB away from overhang & ladder.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 13 April 2022
Resolution: EPIRB moved
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 April 2022 Resolved
Coast Guard inspected small passenger vessels must be equipped with a VHF-DSC radio installation. Connect VHF radio to DSC. 47 CFR 80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 12 April 2022
Resolution: DSC installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2022 Resolved
Alcohol test swabs were expired. Replace with updated alcohol test swabs.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 12 April 2022
Resolution: Procured test swabs
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 11 April 2022 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and stern of the vessel. Mark port & starboard bow with vessel name.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 19 April 2022
Resolution: Name stenciled on p/s bow
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 April 2022 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 19 April 2022
Resolution: Placard installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2021 Resolved
Suitable guards and covers shall be installed in way of of all exposed and hazardous places such as gears, machinery, etc.. Mechanical guards required on port/starboard shafts and drive belts. 46CFR177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 13 May 2021
Resolution: Operator provided photo documentation of mechanical guards.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 5 May 2021 Resolved
Each disposable hydrostatic release unit must be marked with an expiration of two years. EPIRB hydrostatic release expired and requires replacement. 46CFR185.740
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 13 May 2021
Resolution: Operator provided photo documentation of installed hydrostatic release as well as expiration date marked out.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021 Resolved
Electrical equipment shall be installed and maintained to prevent electrical shock and hazards. Distribution circuit break panel located under interior stairs is not properly secured inside distribution box and front cover required attachment. 46CFR183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 6 May 2021
Resolution: Operator sent CG MI a picture and video of the repaired distribution box and door panel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Wire connections on P/STBD aft quarters under gunnel need to be made within an enclosure. 46CFR183.340(G)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 6 May 2021
Resolution: Operator sent pictures of installed waterproof enclosures to the CG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2020 Resolved
Vessels constructed of wood must provide bilge alarms watertight compartments, except in small buoyancy chambers. #2 void bilge alarm was inoperable.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2020
Resolved 24 June 2020
Resolution: Received satsifactory proof of fully operational #2 void bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 June 2020 Resolved
A marine employer whose vessel is involved in an incident or incident that is, or likely to become, a serious marine incident the marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel chemically tested. Vessel was missing 2 alcohol test strips and 01 was expired. 46 CFR 4.06-1.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Alcohol strips are ordered
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 June 2020 Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard, or rail. Both MDE's were missing guards on rotating gears.46 CFR 177.940
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Guards were replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020 Resolved
A vessel must carry one floating waterlight, unless it is limited to day-time operations. Vessel's waterlight was not attached to ring buoy. 46 CFR 180.70(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Waterlight attached to ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2020 Resolved
A vessel not required to have a power driven fire pump by 46 CFR 181.300 must have at least 3 2.5 gallon buckets, with an attached lanyard to the satisfaction of the cognizant OCMI and must be labeled “FIRE BUCKET” in contrasting colors. Vessel was missing fire buckets. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: 3 fire buckets were ourchased and on board
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2020 Resolved
Each connection to a conductor or terminal part must be made within an enclosure. All bilge wiring connections were not in an enclosure. 46 CFR 183.340(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Bilge wiring connections were in enclosed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2020 Resolved
Each life jacker carried on a vessel on oceasn, coastwise, or Great Lakes route must have a life jacket light. Vessel can operate as an unispected Passenger Vesel on an oceans route in accordance with current COI and must have lights on an 09 adult life jackets and 02 child life jackets. 46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 7 July 2020
Resolution: Lights were added to lifejackets
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 September 2019 Resolved
Vessel owner had fabricated a box that held fishing rods for passengers and also provided protection for the glass hatch on the forward main deck. This hatch is the emergency escape hatch from the accommodation space and must be maintained accessible at all times.
Action required: 10 - Deficiency Rectified
Due 16 September 2019
Resolved 16 September 2019
Resolution: Vessel owner removed box.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 April 2019 Resolved
Vessel's power on indicating light is inoperable on the fire control panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 3 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 April 2019 Resolved
Vessel is missing its FCC Radio Safety Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 3 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 April 2019 Resolved
Vessel's navigational publications are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2019 Resolved
MI identified pvc piping in the generator's exhaust piping. Prior to operating generator, vessel needs to replace piping with authorized material.
Action required: 705 - Other - as specified
Resolved 3 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2019 Resolved
Provide safety guard on starboard main engine
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 3 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2019 Resolved
Mount high level bilge alarm located in the most fwd space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2019 Resolved
Provide portable hand bilge pump capable of pumping 5 gpm
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2019 Resolved
Vessels need to plug a hole in the fwd engine room bulkhead on the starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 26 April 2019
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 April 2018 Resolved
Provide Light List and Coast Pilot.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 27 April 2018
Resolution: Provided evidence of rectification and receipt of purchase.
Communications › Radio Communications › EPIRB
Issued 20 April 2018 Resolved
Provide HRU for EPIRB.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 1 May 2018
Resolution: Provided evidence of rectification and receipt of purchase.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 June 2017 Resolved
Install exhust clamp on MDE exhust.
Condition: Improper/Lack of Maintenance
Due 15 July 2017
Resolved 23 April 2018
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 15 June 2017 Resolved
Adjust port stuffing box packing.
Due 15 July 2017
Resolved 23 April 2018
Resolution: Vessel has installed drip-less packing glands.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 June 2017 Resolved
Repair stern light.
Due 15 July 2017
Resolved 23 April 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 June 2016 Resolved
Label 12v breakers in rod room.
Due 6 July 2016
Resolved 9 September 2016
Engineering › Bilge Water Management System › Pump
Issued 6 June 2016 Resolved
Repair forepeak bilge pump float switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2016
Resolution: Bilge pump switch wiring repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 6 June 2016 Resolved
Shave transverse frame IWO port shaft so that shaft is not rubbing.
Due 6 July 2016
Resolved 9 September 2016
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 6 June 2016 Resolved
Secure cable harness above starboard MDE.
Due 6 June 2016
Resolved 9 September 2016
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 June 2016 Resolved
Remove spring clamps on battery charger.
Due 6 July 2016
Resolved 9 September 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 June 2016 Resolved
Provide outlet for freezer in rod room.
Due 6 July 2016
Resolved 10 June 2016
Resolution: Outlet provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2016 Resolved
Provide guard for starboard MDE pulleys.
Due 6 July 2016
Resolved 9 September 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 23 April 2014 Resolved
Faceplate not properly attached to electrical box and missing blanks.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2014
Resolution: Owner has provided receipt for the purchase of new electrical box cover and installed new cover.
Fire Fighting › Nozzles › Size
Issued 18 March 2014 Resolved
Nozzle for wash down/fire hose must be provided.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2014
Resolved 2 June 2014
Resolution: Nozzle in place and tested sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 March 2014 Resolved
Make repairs to the black water tank as discussed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2014
Resolved 2 June 2014
Resolution: Tank repair completed.
Lifesaving › Lifebuoys › Serviceable
Issued 18 May 2012 Resolved
Replace life ring on starboard side.
Due 18 June 2012
Resolved 22 June 2012
Resolution: Life ring replaced.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 May 2012 Resolved
Replace retro tape as needed
Due 18 June 2012
Resolved 22 June 2012
Resolution: Retro tape replaced.
Lifesaving › Hand Flares › Quantity
Issued 18 May 2012 Resolved
Provide 04 orange smoke flares.
Due 25 May 2012
Resolved 22 May 2012
Resolution: 06 new flares provided.
Communications › Radio Communications › EPIRB
Issued 18 May 2012 Resolved
Service EPIRB due to broken activation tab
Action required: 705 - Other - as specified
Resolved 22 June 2012
Resolution: Activation tab replaced.
Communications › Radio Communications › EPIRB
Issued 18 May 2012 Resolved
Replace hydrostatic release.
Action required: 705 - Other - as specified
Resolved 22 May 2012
Resolution: New hydrostatic release provided.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 May 2012 Resolved
Install blank in DC panel under steps.
Due 18 June 2012
Resolved 22 June 2012
Resolution: Blank installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 May 2012 Resolved
Repair cracked deck rail, starboard side near spring cleat.
Due 18 June 2012
Resolved 2 October 2012
Resolution: Crack re-welded.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 January 2009 Resolved
Provide a 3-6 ft, floating black (or uv resistant) line for the water light on the ring buoy. The line must have a clip on the end to attach to the ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: UV resistant line attached between water light and ring buoy with clip on water light end.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 January 2009 Resolved
Provide a 60 ft floating black (or uv resistant) lime for the ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: UV resistant line attached to ring buoy.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 January 2009 Resolved
Provide a cover over the stbd engine rotating machinery.
Due 4 May 2009
Resolved 13 July 2009
Resolution: Guard installed.
Engineering › Bilge Water Management System › Not Operational
Issued 8 January 2009 Resolved
Repair the high bilge water alarm in the compartment fwd of the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: High bilge water alarm repaired.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 8 January 2009 Resolved
Vessel must provide compass deviation table.
Due 11 May 2009
Resolved 13 July 2009
Resolution: Deviation card provided.
Construction/Loadline › Hull › Bottom Plating
Issued 12 May 2008 Resolved
Replaced two butt blocks aft inboard of rudders.
Due 12 May 2008
Resolved 12 May 2008
Resolution: Owner repaired with new butt blocks & bolts.
Construction/Loadline › Hull › Transverse Frame
Issued 12 May 2008 Resolved
Bottom frame IWO P & S shafts in E/R fractured longitudinally following grain of wood from notch cut upon initial construction to allow shaft clearance. Wood dry and checked. Owner found during his exam of vessel and fixed.
Due 12 May 2008
Resolved 12 May 2008
Resolution: Frames glued along check following grain and lag bolted to clamp together.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 May 2008 Resolved
Collision BHD small section of plywood delaminated at chine level stbd side. Owner observed and repaired during drydocking.
Due 12 May 2008
Resolved 12 May 2008
Resolution: Delaminated section cut away. New piece glued in place and then doubler fitted as a batten over the repaired area. Secured with marine adhesive and screws.
Communications › Alarms/Indicators › High Water Alarm
Issued 18 January 2005 Resolved
Repair lazarette high level alarm. Prove proper operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2005
Resolved 10 February 2005
Fire Fighting › Fire Pumps › Capacity
Issued 18 January 2005 Resolved
Prove proper operations of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2005
Resolved 10 February 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 January 2005 Resolved
Renew line around lifebuoy.
Condition: Unknown
Due 18 February 2005
Resolved 10 February 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 January 2005 Resolved
Provide CG Light List
Condition: Placed in Improper Service
Due 18 February 2005
Resolved 7 March 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 January 2005 Resolved
Provide tide tables & current tables for 2005.
Condition: Placed in Improper Service
Due 18 February 2005
Resolved 10 February 2005
Communications › Radio Communications › EPIRB
Issued 18 January 2005 Resolved
Provide proof of EPIRB registration.
Due 18 February 2005
Resolved 10 February 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 December 2003 Resolved
Provide one child PFD, until provided vessel is limited to (5) children.
Due 5 January 2004
Resolved 2 January 2004
Communications › Alarms/Indicators
Issued 22 December 2003 Resolved
Repair high level bilge alarms visual indicators, until repaired vessel can not operate with passengers. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2004
Resolved 2 January 2004
Communications › Radio Communications
Issued 22 December 2003 Resolved
Provide updated EPIRB registration sticker. LEGACY COMPONENT DESC: EPIRB
Due 5 January 2004
Resolved 2 January 2004
Documentation › Markings/Placards
Issued 22 December 2003 Resolved
Provide vessel with emergency broadcast placard. LEGACY COMPONENT DESC: Emergency broadcast placard
Due 5 January 2004
Resolved 2 January 2004
Navigation › Collision/Grounding Avoidance
Issued 22 January 2003 Resolved
Fwd mast light inop. Repair/renew LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 8 February 2003
Resolution: Received fax item complete.
Navigation › Piloting/Steering
Issued 22 January 2003 Resolved
No light for compass. Repair/renew vsl restricted to daylight ops. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 8 February 2003
Communications › Alarms/Indicators
Issued 22 January 2003 Resolved
Fwd compartment high level alarm inop. Repair/renew prior to carrying passengers. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 8 February 2003
Communications › Radio Communications
Issued 22 January 2003 Resolved
EPIRB did not flash when tested, missing antenna missing, hydrostatic release out dated. Vsl restricted to three miles. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 8 February 2003
Engineering › Fuel Oil Service System
Issued 22 January 2003 Resolved
Unable to get cover open for access for emergency fuel shut off. Repair/renew prior to carrying passengers. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 8 February 2003
Lifesaving
Issued 12 October 2000 Resolved
RENEW SUN WORN LIFELINE WHICH SECURES DROP BASKET IN CENTER OF LIFE FLOAT.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Electrical
Issued 12 October 2000 Resolved
REPLACE MISSING COVER FOR POWER PANEL WITH 12 VDC BILGE PUMP CONTROLS. (LOCATION UNDER LADDER TO FWD CABIN.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 12 October 2000 Resolved
REPLACE MISSING TAMPER SEAL FOR THE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Lifesaving
Issued 12 October 2000 Resolved
RENEW SHORT PENDANTS ON LIFE FLOAT.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 24 September 1999 Resolved
PROVIDE 2 TAMPER SEALS FOR 2 PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 1 October 1999
Resolved 12 October 1999
Navigation
Issued 24 September 1999 Resolved
TIGHTEN/REPACK RUDDER SHAFT PACKING GLANDS.
Condition: Unknown
Due 1 October 1999
Resolved 12 October 1999
Electrical
Issued 24 September 1999 Resolved
REMOVE DEAD END WIRE, WHEELHOUSE DECK.
Condition: Unknown
Due 1 October 1999
Resolved 12 October 1999
Lifesaving
Issued 24 September 1999 Resolved
MOUNT 2 RING BOUYS.
Condition: Unknown
Due 1 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 15 October 1998 Resolved
PROVIDE REPLACEMENT FOR TWO DEFECTIVE PFD LIGHTS. VESSEL LIMITED TO NMT 20MILES FROM SHORE.
Condition: Unknown
Due 10 November 1998
Resolved 29 October 1998
Unknown
Issued 15 October 1998 Resolved
RENEW STBD SIDE AFT WINDOW GLASS ON MAIN CABIN
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 15 October 1998 Resolved
CAP SEA VALVE FROM AUX GENERATOR SET.
Condition: Unknown
Due 31 December 1998
Resolved 29 October 1998
Engineering
Issued 15 October 1998 Resolved
REMOVE FUEL TANKS FROM FOUNDATION TO PERMIT EXAMINATION.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Lifesaving
Issued 20 October 1994 Resolved
MARK PFD STORAGE WITH THE NUMBER AND SIZE.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Lifesaving
Issued 20 October 1994 Resolved
POST INSTRUCTIONS FOR BOTH STYLES OF PFD'S ABOARD.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Electrical
Issued 20 October 1994 Resolved
COMPLETE REBUILDING OF AUX AC GEN SET AND PROVE PROPER OPERATION.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Electrical
Issued 20 October 1994 Resolved
RELAIR FWD ELECTRIC BILGE PUMP WIRE SPLICE/JUNCTION CONNECTIONS.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Lifesaving
Issued 20 October 1994 Resolved
RENEW 1 CHILD AND 4 ADULT PFD'S. TOTAL PERSONS ALLOWDE REDUCED TO 48 PERSONS.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Engineering
Issued 20 October 1994 Resolved
RENEW WORN LUBE OIL HOSES ON PORT AND STARBOARD MDE AND INSTALL EFFECTIVE CHAFFING GEAR.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Electrical
Issued 20 October 1994 Resolved
FASTEN CABLE CLAMPS ON STARTER MOTOR FEED WIRE NEAR PORT SIDE AFT MOTOR MOUNT.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Electrical
Issued 20 October 1994 Resolved
REPLACE MISSING FREQUENCY METER COVER FOR 110 VAC SYSTEM.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Navigation
Issued 20 October 1994 Resolved
ADJUST PACKING GLAND FOR STBD RUDDER STOCK
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 3 October 1990 Resolved
CLEANED AND FREED DOGS ON DECK HATCHERS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Lifesaving
Issued 3 October 1990 Resolved
REPLACED DEFECTIVE PFD LIGHT
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Engineering
Issued 3 October 1990 Resolved
CLEANED ALKALI SALTS OFF STRUT BOLTS.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Construction/Loadline
Issued 3 October 1990 Resolved
CAULKED CABLE PENETRATION OF FWD BHD
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Navigation
Issued 3 October 1990 Resolved
REPACKED RUDDER STOCK.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Lifesaving
Issued 3 October 1990 Resolved
REPLACED DUST CAP ON EPIRB.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Accommodation/Occupational Safety
Issued 3 October 1990 Resolved
REPAIRED LADDER TO BRIDGE
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Construction/Loadline
Issued 3 October 1990 Resolved
INSTALLED DECK HATCH SECURING CHAINS.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Construction/Loadline
Issued 1 June 1989 Resolved
MAKE VESSEL AVAILBALE FOR EXAMINATION OF HULL DAMAGE.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Engineering
Issued 1 November 1988 Resolved
INSTALL CLAMPS AT FAIRLEADS ON FLEXIBLE FUEL LINE FOR AUX GEN.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Engineering
Issued 8 October 1987 Resolved
PROVIDE RETRO FIT TO FUEL FILTERS.
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Engineering
Issued 31 October 1986 Resolved
REPLACE THIN WALL PLASTIC DISCHARGE PIPING ON SUBMERSIBLE BILGE PUMP WITH JACKETED WATER HOSE WITH AT LEAST 1" DIAMETER.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Accommodation/Occupational Safety
Issued 31 October 1986 Resolved
PROVIDE ONE EXHAUST VENT WITH PIPING TO BILGE LEVEL.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.