Records from 2016 to 2026. Most recent: inspection, 30 April 2026.
Inspection history · 21
30 April 2026
Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8359099
1 April 2026
Internal Structural Exam · Drydock Exam · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8340208
12 June 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8157742
4 March 2025
Periodic Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8088148
2 April 2024
Internal Structural Exam · Cargo Tank Internal · Hull Examination · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7888606
20 March 2024
Administrative Inspection · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7882087
8 January 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7846265
17 March 2023
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7654145
8 March 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7637007
8 November 2022
In-Service Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7557663
8 December 2021
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7327770
8 February 2021
Drydock Exam · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7137261
17 November 2020
Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7096668
8 October 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7073902
11 December 2019
Periodic Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6855900
3 May 2019
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6675696
6 December 2018
Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6584451
8 November 2017
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6303211
12 December 2016
Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6042113
5 April 2016
Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5847089
21 January 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5801103
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 1 April 2026
Resolved
Aft rake, Leaking tank to be identified, and provide evidence of tank tagged out.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Tank was identified as slop tank. Tank was emptied, tagged out, and locked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 March 2024
Resolved
Each tank vessel must undergo dry dock, internal structural, and cargo tank internal examinations at intervals prescribed in 46 CFR Table 31.10-21(a). Dry dock, internal structural, and cargo tank internals for NRC VALOR expire after 30 March 2024, as stated on your COI. Vessel will be in transit from St. Croix to Rhode Island in order to conduct credit dry dock, but dates will expire in route. During transit, vessel not be authorized to carry cargo or freight. On or before your arrival, schedule your credit dry dock. Local OCMI will decide manner in which this deficiency will be cleared.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 22 April 2024
Resolution: Completed credit Hull, ISE and cargo tank internals
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 10 January 2024
Resolved
Vessel has at least one tank overfill sensor switch per cargo tank that is designed to activate an alarm when its normally closed contacts are open. Repair alarm to working condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2024
Resolved 10 January 2024
Resolution: Replaced light bulb retested SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 January 2024
Resolved
The contents must be marked on the containers, and the containers must be labeled in accordance with DOT requirements for flammable liquids.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2024
Resolved 11 January 2024
Resolution: Crew has repainted sun faded signage.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 January 2024
Resolved
The shipper and/or owner of the barge shall be responsible for the installation of the required placards or signs and maintenance of them. Relabel both sun faded DANGER KEEP OUT sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2024
Resolved 11 January 2024
Resolution: New placards have been installed on vessel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 March 2023
Resolved
A CO2 system must be installed in all paint lockers. Replace/ repair extinguisher hose is cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 6 April 2023
Resolution: Hose has been replaced.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 March 2023
Resolved
Emergency instructions must be conspicuously displayed at each muster station for life raft. Replace dilapidated sticker at muster station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 27 April 2023
Resolution: New sticker has been installed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 March 2023
Resolved
Warning signs shall be placed that it will be visible on all sides. Replace dilapidated sign on the Star board side of barge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 27 April 2023
Resolution: Warning sign has been stenciled and are now visible.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023
Resolved
Life jackets must be readily accessible. Repair hinge to the life jacket locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 6 April 2023
Resolution: Container hinge has been fixed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 March 2023
Resolved
High level alarm be identified in black letters at least 2 inches high on white back ground. Post signage or paint signage for high and over fill alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 6 April 2023
Resolution: High level alarms have been labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 March 2023
Resolved
Any vessel of at least 5 net tons owned by citizens of the U.S. is eligible for documentation. Provide updated docs.
1. Barge Security Officer
2. Updated VGP
3. Security Annual Exercise
4. Vessel Response Plan
5. SOPEP
6. P/V testing cert.
7. Cargo Piping Hydro cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 6 April 2023
Resolution: Seen updated paperwork for vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 March 2023
Resolved
All values and fittings shall be of material, design and manufacture for the intended service. Repair broken bolt on valve 1P. Repair broken weld on hinge stop of hatch to tank 1S.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 6 April 2023
Resolution: Value has been repaired.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 8 November 2022
Resolved
Red warning signal shall be so placed that it will be visible on all sides. Grey flag needs to be painted red.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 1 December 2022
Resolution: Flag has been painted red.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 November 2022
Resolved
A vessel must comply with the applicable requirements for a station operators license and safety installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a active safety station license and operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 17 March 2023
Resolution: Received certificate of Leeland Chapman completeing FCC marine operator course.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2022
Resolved
Each life jacket carried on a vessel on a oceans route must have a life jacket light. Replace broken lights on life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 1 December 2022
Resolution: Replaced all life jacket lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2022
Resolved
At least one ring life buoy must be fitted with a lifeline.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 1 December 2022
Resolution: Life line has been added to ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 8 November 2022
Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers and guards. Re-install guard around slop tank pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 1 December 2022
Resolution: Machinery guard has been placed on the slop tank pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2022
Resolved
A vessel or object being towed, shall exhibit sidelights and a stern light. Install batteries in Navigation lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 1 December 2022
Resolution: Batteries have been installed in all portable navigation lights.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 8 December 2021
Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation.
Document not found on board or able to be located electronically by vessel representative.
46 CFR 31.10-30
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 10 December 2021
Resolution: Received scanned copy of "Arthur D. Darden, Inc. Doc. No. 2316-300, Rev.0, NRC VALOR Intact Damage Stability and Longitudinal Strength Analysis." Document is onboard the vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 December 2021
Resolved
Each nonmetallic transfer hose must not burst, bulge, leak, or abnormally distort under static liquid pressure at least 1.5 times the maximum allowable working pressure.
MI observed previous annual test of cargo piping was tested pneumatically.
33 CFR 156.170 (c)(1)(iii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 29 December 2021
Resolution: Received documentation for the annual cargo piping hydrostatic test. The piping was tested to 1.5 MAWP IAW 33 CFR 156.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 October 2020
Resolved
Each pressure vessel listed on the COI must be thouroughly examined externally every 5 years. In addition, each pressure vessel listed on the COI that is fitted with a manhole or other inspection opening so it can be satisfactorily examined internally, must be opened for internal examination every 5 years. The two pressure vessels listed on the NRC Valor COI were due for an internal and external inspection in January 2020. The pressure vessels shall be opened for an internal examination by a USCG marine inspector prior to operational service. 46 CFR 31.30-1 and 46 CFR 61.10-5(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 13 October 2020
Resolution: Internal and external visual inspection of the pressure vessels was completed using a flashlight and borescope.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2019
Resolved
Each tank vessel that operates in salt water must undergo drydock, internal structural, and cargo tank internal examinations, with two examinations within any five year period. No more than three years may elapse between any two examinations.
Vessel's drydock, internal structural, and cargo tank internal examinations have lapsed. Prior to operations complete required examinations. - 46CFR31.10–21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2019
Resolution: Vessel completed DD/ISE/CTIE.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 December 2018
Resolved
On a tank barge, each cargo tank must be equipped with an overfill device. The overfill device for the #4 Stbd tank was alarming in normal condition. The crew had placed a metal device at the top of the overfill pull test switch to keep the alarm from going off. If this tank is to be used before the next dry docking period in April 2019, the crew must continually monitor the level of the tank while filling. 33CFR155.480(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 9 December 2019
Resolution: Tested #4 stbd tank alarm, test sat. Witnessed proper operation of tank alarm in normal position.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 5 April 2016
Resolved
Bent frame and cracked weld on 1P outboard. Top frame. 46 CFR 31.10-21.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2016
Resolution: Ground out and rewelded cracked weld.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 April 2016
Resolved
Cracked weld on inboard frame in 1S. 46 CFR 31.10-21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2016
Resolution: Ground out and rewelded cracked weld.