Records from 1986 to 1992. Most recent: inspection, 10 February 1992.
Documentation record
Registered dimensions (L × B × D)360.9 ft × 98.4 ft × 20.9 ft
Registered tonnagegross 6,244 / net 6,244
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJURONG SHIP BUILDERS · JURONG TOWN, SINGAPORE · built 1979
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSITKA, AK
Trade endorsementsRegistry
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6244 - Regulatory (Subpart C or D), Net Ton
6244 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
10 February 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 953560
5 October 1990
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 905340
16 August 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1213065
16 August 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1238088
12 June 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 932689
12 June 1990
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1222794
13 October 1989
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1195381
22 June 1989
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1195518
2 June 1989
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1031113
27 December 1988
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1343283
3 June 1988
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 888563
3 June 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 894826
1 April 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 995041
18 February 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1020868
17 June 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1005236
24 May 1987
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339074
25 September 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1311366
25 September 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1312892
4 June 1986
Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298024
Electrical
Issued 12 June 1990
Resolved
MAKE OPERABLE LOW-LIFE AIL PRESSURE TRIP TO #2 MAIN GENERATOR.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Lifesaving
Issued 12 June 1990
Resolved
PROVIDE AND INSTALL BREAK FREE LIMB TO #3 LIFERAFT.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Lifesaving
Issued 12 June 1990
Resolved
REPAIR AND RE-INSTALL CO2 SYSTEM TO PAINT LOCKER.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Fire Fighting
Issued 12 June 1990
Resolved
REPAIR FIRE STATIONS 20,21,22,25,28 AND 9.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Lifesaving
Issued 12 June 1990
Resolved
RE-STENCIL PFD LOCKERS ON MAIN DECK.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Engineering
Issued 12 June 1990
Resolved
INSTALL ADEQUASTE RELIEF VALVES TO START-AIR REVEIVER ON SECOND AUXILIARY GENERATOR.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Construction/Loadline
Issued 13 October 1989
Resolved
COMPLETE UNDERWATER EXAM FOR EXTERNAL DRY DOCK CREDIT IN WAY OF THE FOLLOWING AREAS. VESSELS SIDE SHELL, BOTTOM PLATING IN AREA OF REINFORCING STRAPS, AND SEA CHEST OPENINGS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 3 June 1988
Resolved
PROVIDE DOCUMENTATION INDICATING THE MOST RECENT HYDROSTATIC TEST DATE FOR THE ONE HALON BOTTLE IN THE FIXED FIRE EXTINGUISHING SYSTEM THAT COULD NOT BE IDENTIFIED PER 46 CFR 147.04-1.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Accommodation/Occupational Safety
Issued 24 May 1987
Resolved
COVER INSULATION UNDER HALON BOTTLES TO PROPERLY PROTECT.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Unknown
Issued 24 May 1987
Resolved
PROVIDE EVIDENCE OF CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Unknown
Issued 24 May 1987
Resolved
PROVIDE EVIDENCE AND PROPERLY DISPLAY STABILITY LETTER.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Unknown
Issued 24 May 1987
Resolved
PROVIDE EVIDENCE OF LOADLINE CERTIFICATE AND MARK HULL AS REQUIRED.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Unknown
Issued 24 May 1987
Resolved
PROVIDE EVIDENCE OF APPROVED SAFETY PLAN AND POST AS REQUIRED.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Electrical
Issued 24 May 1987
Resolved
LABEL ALL EMERGENCY LIGHTS AS REQUIRED.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Lifesaving
Issued 24 May 1987
Resolved
INSTALL LIFERAFTS IN STANDS PROPERLY AS REQUIRED.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Lifesaving
Issued 24 May 1987
Resolved
MARK LIFERINGS AS REQUIRED BY REGULATIONS THROUGHOUT VESSEL.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Electrical
Issued 24 May 1987
Resolved
LABEL GENERAL ALARM BATTERY BOX.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Lifesaving
Issued 24 May 1987
Resolved
INSTALL BRACKETS FOR LIFERING LIGHTS AS REQUIRED
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Electrical
Issued 24 May 1987
Resolved
COMPLETE PROPER BANDING OF ELECTRICAL WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Construction/Loadline
Issued 24 May 1987
Resolved
MARK REMOTE CLOSING DEVICES AS REQUIRED THROUGHOUT VESSEL.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Unknown
Issued 24 May 1987
Resolved
MARK ALL GENERAL ALARM BELLS AS REQUIRED THROUGHOUT VESSEL.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Unknown
Issued 24 May 1987
Resolved
PROVIDE COPY OF PROPER FUEL OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Fire Fighting
Issued 24 May 1987
Resolved
PROPERLY MARK ALL FIRE STATIONS AS PER REGULATIONS.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987
Fire Fighting
Issued 24 May 1987
Resolved
INSTALL LOW VELOCITY FOG APPLICATORS AT FIRE STATIONS WHERE REQUIRED.
Condition: Unknown
Due 24 May 1987
Resolved 24 May 1987