MAURY USCG vessel records Sign in
← All vessels

OUTRAGEOUS V

OUTRAGEOUS V is a 1978 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1981, most recently in March 2026, along with 107 deficiencies and 12 casualty investigations between 2003 and 2021.

Records from 1981 to 2026. Most recent: inspection, 16 March 2026.

Built
1978
Last inspected
16 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WSB6889
Flag
UNITED STATES
367078020
Maury page id
psix-49912

Inspections, by type

…with no type recorded21
Years with a record 43 calendar years (1981–2026)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS, INC · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMOREHEAD CITY, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WSB6889MMSI 367078020 · active · compulsorily equipped · granted 6 March 2026, expires 14 January 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MIDNIGHT EXPRESS Passenger (Inspected) · MISLE 54179 · 20 June 2020 · activity 6986488

Inspection history · 84

16 March 2026 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8319855
6 May 2025 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8129713
16 April 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7893645
12 March 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7877602
24 April 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7669982
21 December 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7611649
15 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425726
4 March 2022 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7404008
24 September 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7319835
28 July 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7274968
18 March 2021 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7148932
25 October 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7084829
20 June 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6986488
19 May 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6954075
26 February 2020 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6903128
11 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6651580
6 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6428295
7 February 2018 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6351078
14 July 2017 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6360575
21 April 2017 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6129908
30 March 2017 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6104498
22 February 2016 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5819649
27 August 2015 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6081789
1 May 2014 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4854515
5 March 2014 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4794452
5 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4307720
28 February 2012 Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4241176
12 September 2011 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 4142638
22 July 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4101794
15 March 2010 DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3696477
24 April 2009 DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3453624
19 March 2008 Annual Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3179302
4 April 2007 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2902070
11 July 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2752056
7 March 2006 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2597120
20 April 2005 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2338794
29 April 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2058341
29 March 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2037548
3 September 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1895687
17 April 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1777866
10 April 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1602828
22 March 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1495819
20 April 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1415585
4 May 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1415351
8 March 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1424881
4 May 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1447940
13 April 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1468053
18 February 1999 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1129364
20 June 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 122995
14 May 1998 COI Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1111451
25 August 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1120264
21 July 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1115208
4 April 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1100717
18 March 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1105373
20 July 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 152267
5 April 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1082080
5 March 1996 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 880318
5 March 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 885030
10 March 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1133661
10 March 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1173524
29 April 1994 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 858663
29 March 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 856311
16 November 1993 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1141386
23 April 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 827204
24 March 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1149091
7 April 1992 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 948468
17 March 1992 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1136494
16 April 1991 Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1219211
30 May 1990 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1234586
4 April 1990 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 904069
14 September 1989 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1198951
4 May 1989 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1040031
12 April 1989 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 896092
14 June 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 890715
9 May 1988 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1348582
7 March 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1337189
1 May 1987 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1026894
4 June 1986 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 992956
17 April 1986 COI Inspection
Physical examination · THE UNKNOWN UNIT · Activity 1301014
10 April 1986 Credit Drydock
Administrative · THE UNKNOWN UNIT · Activity 1301009
11 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284639
27 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972839
4 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964729
2 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969478

Deficiency record · 107

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2023 Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it. Vessel was missing tag. Provide proof that float free link has the correct certificate/tag to the attending MI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 4 May 2023
Resolution: New float free link was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 24 April 2023 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free. Line was not properly stowed in canister. Re-lay line and mount link correctly. Make available for re-inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: Painter properly attached to the float free link.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 April 2023 Resolved
A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Engine room hatch was not secured to vessel. Make hatch secured and ready for re-inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: Captive securing device intstalled preventing its loss.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2023 Resolved
Each life raft must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018. SOLAS reflective tape needs to be replaced on life raft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: SOLAS reflective tape replaced on life raft.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 April 2023 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Re-label oars in life raft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: Re-labeled oars in life raft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021 Resolved
Prove proper operation for passenger compartment bilge suction.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Took suction on passenger compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2021 Resolved
Replace both ring buoys
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 2 April 2021
Resolution: Bloth life ring buoys were renewed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 March 2021 Resolved
Install captive chains on forepeak scuttle and steering compartment scuttle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Captive chains installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2021 Resolved
FCC Safety Radiotelephony Certificate expired
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: FCC Safety Radiotelephony Certificate is up to date.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2021 Resolved
Navigational paper charts for area/operational not onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Up to date charts are onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 March 2021 Resolved
Provide EPIRB registration.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Epirb registration is onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Clean terminal block under console due to corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Terminal block was cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Remove dead ended wire under console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 2 April 2021
Resolution: Dead ended wires were removed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 March 2021 Resolved
Provide documentation for EPIRB hydrostatic release mechanism or nenew.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Documentation provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021 Resolved
Make fuel cutout valve handles watertight
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 2 April 2021
Resolution: Fuel cut out valve was made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021 Resolved
Water spout on bilge manifold needs handle and cap.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Cap was added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Hardwire battery charger in engine room forward bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2021
Resolved 8 April 2021
Resolution: The charger was hardwired in using a junction box and boat cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Install battery terminal covers in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Terminal covers were added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021 Resolved
Starboard MDE sea strainer is loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Sea strainer was secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021 Resolved
Prove proper operation for bilge overboard valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Valve is now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021 Resolved
Remove inoperable fuel filter assembly in E/R aft bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Fuel filter assembly was removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 March 2021 Resolved
Prove proper operation for engine room watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Hatch is now operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Connections must be made to battery terminals with permanent type connectors.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Permenant connectors were added to the terminals.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 March 2021 Resolved
Ensure forepeak is de-watered prior to carrying passengers. Maintain in accordance with stability letter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 March 2021
Resolved 18 March 2021
Resolution: Fore peak was de-watered with installed bilge pump and piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 March 2021 Resolved
Install gasket on aft passenger compartment door and pilothouse door to make weathertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 2 April 2021
Resolution: Gaskets were properly installed on aft door and pilothouse door.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 18 March 2021 Resolved
Replace carpet on upper deck and remove rug.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 16 April 2021
Resolution: Upper deck rug was renewed and properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2021 Resolved
Secure carpet in passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 2 April 2021
Resolution: Carpet was secured and trip hazard was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2021 Resolved
Renew line on canopy and replace damaged grommets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 2 April 2021
Resolution: Canopy line and grommets were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021 Resolved
Install hose clamp on forward electric bilge pump
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Hose clamp installed to the pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021 Resolved
Adjust and renew as needed, both MDE alternator belts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 2 April 2021
Resolution: The belts for both mde alternators were replaced and properly tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2021 Resolved
One adult life jacket is wasted. Replace. 705: restricted to 29 passengers
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2021
Resolved 29 March 2021
Resolution: Adult size life jacket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 March 2021 Resolved
Install float free link for life floats
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Float free link was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 March 2021 Resolved
Re-mark vessel name on both life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Both life floats were properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 March 2021 Resolved
Replace 2 paddles on life floats and properly label.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Both paddles were renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2020 Resolved
Provide proof of third party servicing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2020
Resolved 29 May 2020
Resolution: Vessel rep provided photos and docs after MI requested due to outstanding defs. All SAT
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 May 2020 Resolved
Vessels EPIRB battery is expired. Provide proof of valid battery. Limited to Less than 20 NM route.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2020
Resolved 26 May 2020
Resolution: EPIRB battery replaced and working.SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2019 Resolved
Fire Ext. rusted at nozzel and at base. Sand and repaint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: Fire ext. repainted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 April 2019 Resolved
Replace lifefloat float light due to UV damage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: New light install
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2019 Resolved
Make electrical connections water tight on pilot house as discussed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: electrical connection water tight.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 April 2019 Resolved
Generator salt water strainer cooling hose has cracking. Replace hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2019
Resolved 15 April 2019
Resolution: End of hose cut off and reinstalled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 June 2018 Resolved
Replace float light lanyard and attached around the body of life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2018
Resolved 20 June 2018
Resolution: New lanyard installed and attached properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 June 2018 Resolved
Replace expaired first aid items and or missing.
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 20 June 2018
Resolution: New meds placed on vsl.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 June 2018 Resolved
Replace stbd engine inboard hose (raw water) as marked.
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 20 June 2018
Resolution: New hose installed
Lifesaving › Hand Flares › Expired
Issued 6 June 2018 Resolved
Replace six orange smoke signals by expiration (end of month)
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 20 June 2018
Resolution: New flares on vsl
Stability › Weathertight Integrity › General
Issued 30 March 2017 Resolved
Cracked window aft pilot house port side
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: Window has been replace with new.
Electrical › Electric Supply System (service) › Cable
Issued 30 March 2017 Resolved
Wash down pump hooked to battery with alligator clips. Remove wiring and pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: removed pump and wiring for wash down pump.
Electrical › Electrical Distribution System (emergency) › Fuse
Issued 30 March 2017 Resolved
Fuse holder for radio and ssb busted/broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: Replaced fuse panel with new panel in kind.
Construction/Loadline › Penetrations › Gasket
Issued 30 March 2017 Resolved
Aft Cabin door gsk need to be secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: Reinstalled door gsk.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 March 2008 Resolved
Repair float light for ring buoy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 20 May 2008
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 March 2008 Resolved
Renew/replace retro on Life floats
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 May 2008
Resolved 20 May 2008
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 4 April 2007 Resolved
Replace retro tape on Life ring and lifefloat
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 12 May 2008
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 4 April 2007 Resolved
Provide a rescue harness for man overboard situations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 12 May 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 April 2007 Resolved
Replace line around lifering with 3/8" UV resistant line.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 12 May 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 March 2006 Resolved
Properly seal all penetrations through forward engine room bulkhead and aft engine room bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Construction/Loadline › Hull › Transverse Frame
Issued 7 March 2006 Resolved
Vee and weld fractures on #3 & #4 tranverse frames port and starboard aft of the collision bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Engineering › Bilge Water Management System › Hose
Issued 7 March 2006 Resolved
Two clamps on each end of a flexible hose must be installed on piping systems that penetrate the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Engineering › Bilge Water Management System › Piping
Issued 7 March 2006 Resolved
Clean and exam engine room bulkhead fitting for forward bilge piping system.
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 7 March 2006 Resolved
Replace handle (cord grip) for reach rod on emergency fuel shut-off valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Construction/Loadline › Structures › Superstructure
Issued 7 March 2006 Resolved
Replace cracked port side window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Engineering › Bilge Water Management System › Valve
Issued 7 March 2006 Resolved
PMS handle (cord grip) on reach rod for emergency shut-off valve on forward peak bilge system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 11 April 2006
Engineering › Bilge Water Management System › Piping
Issued 7 March 2006 Resolved
Replace PVC piping for forward peak bilge system with Aluminum or steel piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Lifesaving › Hand Flares
Issued 29 April 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 1 May 2004
Resolution: VERIFIED PURCHASE RECEIPT FOR FLARES.
Lifesaving
Issued 17 April 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 18 April 2003
Resolution: NEW HYDROSTATIC RELEASE PURCHASED AND INSTALLED.
Engineering › Reduction Gearing/Clutches
Issued 17 April 2003 Resolved
REPLACE FAULTY GAUGE/SENDING UNIT FOR STBD MRG OIL PRESSURE.
Action required: 705 - Other - as specified
Resolved 18 April 2003
Resolution: NEW SENDING UNIT PURCHASED AND INSTALLED.
Lifesaving
Issued 14 May 1998 Resolved
PROVIDE FCC TYPE ACCEPTED CATEGORY I, 406 EPIRB, INSTALLED TO AUTOMATICALLYFLOAT FREE AND ACTIVATE PRIOR TO 01FEB99.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Electrical
Issued 21 July 1997 Resolved
Provide means of measuring frequency generated as required by 46 CFR 183.320(c).
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Electrical
Issued 21 July 1997 Resolved
Provide chafing gear at bulkheads where electrical wires are run and_x001C_ provide wire ties to hang new wiring.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Engineering
Issued 18 March 1997 Resolved
INSTALL GUARD IN WAY OF FIXED BILGE PUMP ON STBD ENGINE, NO LATER THAN 18 APRIL 1997.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 18 March 1997 Resolved
REPAIR FRACTURE IN PORT SIDE SUPPORT BRACKET IN WAY OF BATTERY TRAY, NO LATER THAN 18 APRIL 1997.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 18 March 1997 Resolved
CORRECT PFD STOWAGE TO REFLECT ACCURATE NUMBER OF ADULT (30) AND CHILD (3) PFD'S ONBOARD.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Engineering
Issued 18 March 1997 Resolved
REPAIR/REPLACE STBD MAIN ENGINE EXHAUST SUPPORTS WHERE FRACTURED, NO LATER THAN 18 APRIL 1997.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE REPAIR PROPOSAL FOR (4) FRACTURES LOCATED ON TRANSOM (IN WAY OF SWIM PLATFORM) AND MAKE PROPER REPAIRS TO SAME.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE GAUGINGS OF PORT SIDE AREA, AS MARKED.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, CROP AND RENEW HULL IN WAY OF STARBOARDSIDE BOW WHERE TEMPORARY REPAIR EXISTS.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, MAKE PROPER REPAIRS TO ALL FRACTURES (TOTAL OF 20) LOCATED IN VOID BENEATH PASSENGER ACCOMODATIONS IN WAY OF STANCHIONS/GUSSETS.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, CROP AND RENEW AS ORIGINAL, AREA ON PORT SIDE, FWD OF MIDSHIP IN WAY OF WATERLINE (WHERE TEMP REPAIR EXISTS).
Condition: Unknown
Due 26 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPLACE HOSE CLAMPS TO BOTH STUFFING BOXES.
Condition: Unknown
Due 5 March 1996
Resolved 8 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR FRACTURE ON PORT M/E EXHAUST THRU FITTING IN WAY OF AFT ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR AREA IN WAY OF BULL NOSE (WHERE FRACTURED).
Condition: Unknown
Due 26 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR/REPLACE VALVE TO STARBOARD SIDE RAW WATER COOLING LINE TO M/E.
Condition: Unknown
Due 5 March 1996
Resolved 8 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPLACE BILGE PIPING IN ENGINE ROOM, WHERE WASTED AND DEMONSTRATE PROPER OPERATION OF SAME.
Condition: Unknown
Due 7 March 1996
Resolved 8 March 1996
Accommodation/Occupational Safety
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR/REPLACE (2) BROKEN WINDOWS LOCATED ON PORT/STBD SIDE AFT PASSENGER CABIN.
Condition: Unknown
Due 5 March 1996
Resolved 8 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPLACE THRU-HULL VALVE LOCATED ON S/S PASSENGER COMPARTMENT VOID, WHERE PREVIOUS MSD LOCATED.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Electrical
Issued 5 March 1996 Resolved
PROVIDE WIRING SUPPORT FOR RUNS BELOW DECK. ITEM TO BE COMPLETED NLT 05APR96.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR WASTED SECTION OF BILGE PIPE IN ENGINE ROOM AND DEMONSTRATE PROPER OPERATION OF BILGE SYSTEM.
Condition: Unknown
Due 7 March 1996
Resolved 8 March 1996
Accommodation/Occupational Safety
Issued 5 March 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, INSTALL ADDITIONAL RAIL COURSES AT STERN AND PORT/STBD MAIN DECK ACCESSES.
Condition: Unknown
Due 7 March 1996
Resolved 8 March 1996
Electrical
Issued 5 March 1996 Resolved
REMOVE ALL WIRING ASSOCIATED WITH INOPERABLE/PREVIOUSLY REMOVED EQUIPMENT. ITEM TO BE COMPLETED NLT 05APR96.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Lifesaving
Issued 5 March 1996 Resolved
REPLACARD PFD STOWAGE TO REFLECT ACCURATE COUNT OF CHILD PFD'S ONBOARD.
Condition: Unknown
Due 7 March 1996
Resolved 8 March 1996
Fire Fighting
Issued 10 March 1995 Resolved
PROVIDE DOCUMENTATION FOR ANNUAL SERVICE FOR (2) B-II PORTABLE FIRE EXTINGUISHERS IAW NFPA 10.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Accommodation/Occupational Safety
Issued 10 March 1995 Resolved
CORRECT IMPROPER VALVE PLACEMENT FOR MSD SYSTEM IN WAY OF INSTALLATION OF AN OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Construction/Loadline
Issued 29 March 1994 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN FWD BHD OF STEERING COMPT IN WAY OF STBD EXHAUST PIPE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN FUEL TANK PRIOR TO CARRIGE OF PASSENGERS.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Navigation
Issued 24 March 1993 Resolved
PROVE PROPER OPERATION OF VESSELS SSB RADIO ON 2182 AND 2670 MHZ PRIOR TO OPERATION OVER 20 MILES FROM SHORE.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Engineering
Issued 24 March 1993 Resolved
REPAIR LEAK IN PORT ENGINE EXHAUST IN WAY OF MUFFLER.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Lifesaving
Issued 17 March 1992 Resolved
PROVIDE A COAST GUARD APPROVED CATEGORY I EPIRB ON BOARD VESSEL NO LATER THAN 01JAN93.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Accommodation/Occupational Safety
Issued 16 April 1991 Resolved
INSTALL TYPE III HOLDING TANK FOR MSD.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Fire Fighting
Issued 16 April 1991 Resolved
SERVICE OR RENEW THE WHEELHOUSE B-I DRY CHEMICAL EXTINGUISHER, HYDRO DATE NOT LEGIBLE.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Engineering
Issued 16 April 1991 Resolved
REPAIR FRACTURES IN PORT MAIN ENGINE EXHAUST FWD OF FLANGED AREA.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Navigation
Issued 4 April 1990 Resolved
RENEW ALL NAVIGATION LIGHT FIXTURES WITH MODELS THAT MEET THE REQUIREMENTS OF THE 1972 COLREGS FOR VESSELS LESS THAN 20 METERS IN LENGTH.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Lifesaving
Issued 12 April 1989 Resolved
RENEW 15 PERSON LIFEFLOAT.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Engineering
Issued 12 April 1989 Resolved
RENEW FUEL TANK VENT HOSE USING HOSE APPROVED FOR FULE SERVICE.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Electrical
Issued 9 May 1988 Resolved
REPAIR/REPLACE BATTERY BOX. NEUTRALIZE ACID ON BULKHEAD BENEATH BATTERY BOX
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 9 May 1988 Resolved
INSTALL FLAME SCREEN IN FUEL TANK VENT.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Lifesaving
Issued 9 May 1988 Resolved
RENEW THE WEAK LINK FOR LIFEFLOATS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Construction/Loadline
Issued 1 May 1987 Resolved
REWELD CRACKED FRONT ENGINE FOUNDATIONS.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Construction/Loadline
Issued 1 May 1987 Resolved
REWELD DECK SUPPORT STANCHIONS UNDER CABIN DECK.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Fire Fighting
Issued 1 May 1987 Resolved
HYDROSTATICALLY TEST ALL B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987

Casualty record · 12

3 September 2003Routine · role: Involved in a Marine Casualty · activity 1895687
11 July 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2752056
19 June 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3770490
22 July 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4101794
5 May 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4307720
6 August 2012Routine · role: Involved in a Marine Casualty · activity 4411031
16 September 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4728939
27 August 2015Routine · role: Subject of Search and Rescue · serious marine incident, as classified · 1 injured · activity 6081789
14 July 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6360575
20 June 2020Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 6986488
25 October 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7084829
28 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7274968
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record