Inspection history · 22
16 March 2026
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8319855
6 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8129713
16 April 2024
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7893645
12 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7877602
24 April 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7669982
21 December 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7611649
15 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425726
4 March 2022
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7404008
24 September 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7319835
28 July 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7274968
18 March 2021
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7148932
25 October 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7084829
20 June 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6986488
19 May 2020
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6954075
26 February 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6903128
11 April 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6651580
6 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6428295
7 February 2018
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6351078
14 July 2017
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6360575
21 April 2017
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6129908
30 March 2017
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6104498
22 February 2016
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5819649
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2023
Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it. Vessel was missing tag. Provide proof that float free link has the correct certificate/tag to the attending MI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 4 May 2023
Resolution: New float free link was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 24 April 2023
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free. Line was not properly stowed in canister. Re-lay line and mount link correctly. Make available for re-inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: Painter properly attached to the float free link.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 April 2023
Resolved
A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Engine room hatch was not secured to vessel. Make hatch secured and ready for re-inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: Captive securing device intstalled preventing its loss.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2023
Resolved
Each life raft must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018. SOLAS reflective tape needs to be replaced on life raft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: SOLAS reflective tape replaced on life raft.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 April 2023
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Re-label oars in life raft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 4 May 2023
Resolution: Re-labeled oars in life raft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021
Resolved
Prove proper operation for passenger compartment bilge suction.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Took suction on passenger compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2021
Resolved
Replace both ring buoys
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 2 April 2021
Resolution: Bloth life ring buoys were renewed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 March 2021
Resolved
Install captive chains on forepeak scuttle and steering compartment scuttle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Captive chains installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2021
Resolved
FCC Safety Radiotelephony Certificate expired
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: FCC Safety Radiotelephony Certificate is up to date.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2021
Resolved
Navigational paper charts for area/operational not onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Up to date charts are onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 March 2021
Resolved
Provide EPIRB registration.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Epirb registration is onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Clean terminal block under console due to corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Terminal block was cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Remove dead ended wire under console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 2 April 2021
Resolution: Dead ended wires were removed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 March 2021
Resolved
Provide documentation for EPIRB hydrostatic release mechanism or nenew.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Documentation provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021
Resolved
Make fuel cutout valve handles watertight
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 2 April 2021
Resolution: Fuel cut out valve was made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021
Resolved
Water spout on bilge manifold needs handle and cap.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Cap was added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Hardwire battery charger in engine room forward bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2021
Resolved 8 April 2021
Resolution: The charger was hardwired in using a junction box and boat cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Install battery terminal covers in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Terminal covers were added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021
Resolved
Starboard MDE sea strainer is loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Sea strainer was secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021
Resolved
Prove proper operation for bilge overboard valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Valve is now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021
Resolved
Remove inoperable fuel filter assembly in E/R aft bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Fuel filter assembly was removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 March 2021
Resolved
Prove proper operation for engine room watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Hatch is now operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Connections must be made to battery terminals with permanent type connectors.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Permenant connectors were added to the terminals.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 March 2021
Resolved
Ensure forepeak is de-watered prior to carrying passengers. Maintain in accordance with stability letter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 March 2021
Resolved 18 March 2021
Resolution: Fore peak was de-watered with installed bilge pump and piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 March 2021
Resolved
Install gasket on aft passenger compartment door and pilothouse door to make weathertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 2 April 2021
Resolution: Gaskets were properly installed on aft door and pilothouse door.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 18 March 2021
Resolved
Replace carpet on upper deck and remove rug.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 16 April 2021
Resolution: Upper deck rug was renewed and properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2021
Resolved
Secure carpet in passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 2 April 2021
Resolution: Carpet was secured and trip hazard was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2021
Resolved
Renew line on canopy and replace damaged grommets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 2 April 2021
Resolution: Canopy line and grommets were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021
Resolved
Install hose clamp on forward electric bilge pump
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Hose clamp installed to the pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021
Resolved
Adjust and renew as needed, both MDE alternator belts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 2 April 2021
Resolution: The belts for both mde alternators were replaced and properly tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2021
Resolved
One adult life jacket is wasted. Replace. 705: restricted to 29 passengers
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2021
Resolved 29 March 2021
Resolution: Adult size life jacket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 March 2021
Resolved
Install float free link for life floats
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Float free link was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 March 2021
Resolved
Re-mark vessel name on both life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Both life floats were properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 March 2021
Resolved
Replace 2 paddles on life floats and properly label.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2021
Resolved 29 March 2021
Resolution: Both paddles were renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2020
Resolved
Provide proof of third party servicing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2020
Resolved 29 May 2020
Resolution: Vessel rep provided photos and docs after MI requested due to outstanding defs. All SAT
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 May 2020
Resolved
Vessels EPIRB battery is expired. Provide proof of valid battery. Limited to Less than 20 NM route.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2020
Resolved 26 May 2020
Resolution: EPIRB battery replaced and working.SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2019
Resolved
Fire Ext. rusted at nozzel and at base. Sand and repaint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: Fire ext. repainted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 April 2019
Resolved
Replace lifefloat float light due to UV damage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: New light install
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2019
Resolved
Make electrical connections water tight on pilot house as discussed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: electrical connection water tight.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 April 2019
Resolved
Generator salt water strainer cooling hose has cracking. Replace hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2019
Resolved 15 April 2019
Resolution: End of hose cut off and reinstalled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 June 2018
Resolved
Replace float light lanyard and attached around the body of life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2018
Resolved 20 June 2018
Resolution: New lanyard installed and attached properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 June 2018
Resolved
Replace expaired first aid items and or missing.
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 20 June 2018
Resolution: New meds placed on vsl.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 June 2018
Resolved
Replace stbd engine inboard hose (raw water) as marked.
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 20 June 2018
Resolution: New hose installed
Lifesaving › Hand Flares › Expired
Issued 6 June 2018
Resolved
Replace six orange smoke signals by expiration (end of month)
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 20 June 2018
Resolution: New flares on vsl
Stability › Weathertight Integrity › General
Issued 30 March 2017
Resolved
Cracked window aft pilot house port side
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: Window has been replace with new.
Electrical › Electric Supply System (service) › Cable
Issued 30 March 2017
Resolved
Wash down pump hooked to battery with alligator clips. Remove wiring and pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: removed pump and wiring for wash down pump.
Electrical › Electrical Distribution System (emergency) › Fuse
Issued 30 March 2017
Resolved
Fuse holder for radio and ssb busted/broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: Replaced fuse panel with new panel in kind.
Construction/Loadline › Penetrations › Gasket
Issued 30 March 2017
Resolved
Aft Cabin door gsk need to be secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 21 April 2017
Resolution: Reinstalled door gsk.