← All vessels
STAR OF MONTEREY
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named STAR OF MONTEREY
STAR OF MONTEREY is a 1978 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1985, most recently in January 2026, along with 151 deficiencies, 3 operational controls and 2 casualty investigations between 2013 and 2018.
Records from 1985 to 2026. Most recent: inspection, 5 January 2026.
- Built
- 1978
- Last inspected
- 5 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 151 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2013–2018
Identity
598636
WDD4204
49913
Flag
UNITED STATES
367141650
Maury page id
psix-49913
Inspections, by type
…with no type recorded13
Years with a record
38 calendar years (1985–2026)
The 95 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.7 ft × 19.1 ft × 8.0 ft
Registered tonnagegross 75 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY'S ENTERPRISES, INC · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 27 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD4204MMSI 367141650 · active · compulsorily equipped · granted 13 August 2026, expires 26 September 2036
WSX6716MMSI not assigned · expired · compulsorily equipped · granted 1 July 1996, cancelled 13 November 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 95
5 January 2026
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8290044
12 February 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078501
15 February 2024
Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865108
13 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7853645
17 January 2023
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612570
23 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612391
22 February 2022
Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7400920
15 February 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7398461
4 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7150511
14 April 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939703
11 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6925011
25 February 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6912324
9 January 2019
Administrative Inspection · Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600802
27 July 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6511187
9 March 2018
COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6369115
28 February 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6364351
13 February 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6087798
7 March 2016
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828262
29 February 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5835402
18 March 2014
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816410
10 March 2014
Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4813596
7 December 2011
Simplified Stability Test · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4204403
21 September 2011
Type not recorded
No type recorded · Station Monterey · USCG Southwest District (CGD-SW) · Activity 4153333
23 November 2010
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3896337
15 December 2009
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3651449
7 December 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3643985
17 December 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3380260
2 December 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3369951
15 November 2007
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3089821
6 December 2005
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2546881
30 March 2005
Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2322561
10 December 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2256332
26 November 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2248315
18 November 2004
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2221121
18 November 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2244283
16 September 2004
Internal Structural Exam · Drydock Extension
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2176229
15 March 2004
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2025087
4 December 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1960811
6 May 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1777964
28 January 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1736533
10 December 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1717015
26 November 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1710424
10 September 2002
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1671246
26 December 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1473771
18 December 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1474864
22 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076202
14 February 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382153
1 August 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1401288
5 January 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1046813
1 December 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1457719
26 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126025
24 February 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 778864
24 February 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806909
21 January 1999
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787798
1 December 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805358
19 December 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1120714
3 December 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400683
29 January 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103158
5 December 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413091
2 July 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1086749
7 May 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1082709
13 December 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189662
25 August 1995
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879351
19 August 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 117155
30 May 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 873412
7 February 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148926
18 January 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871125
15 December 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146325
9 October 1994
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172552
8 October 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 125884
22 December 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1162973
7 December 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083827
7 December 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159616
8 January 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 840466
17 December 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132406
23 September 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942125
30 January 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 946286
12 December 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 944859
8 February 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216403
13 December 1990
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225424
15 November 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924862
12 September 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923575
4 May 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216730
5 January 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234758
24 May 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 896099
23 February 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044192
9 February 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342570
13 January 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012233
3 November 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328489
10 February 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012477
1 October 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313017
2 September 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1029770
1 August 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290762
29 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290914
24 January 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 972766
Deficiency record · 151
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 January 2026
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. MI found that the bilge pump piping is corroded causing low F/M pressure and back flooding into the engine room bilge when the pump is operational. Patch corroded piping and then replace it at the next drydock to the satisfaction of MI.
46 CFR 185.25-1(a) (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2026
Resolved
Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. MI discovered Fuel Oil leak on the starboard fuel tank intake pipe. Replace starboard intake pipe to the satisfaction of the MI.
46 CFR 182.20-30(b) (OLD T)
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in... A machinery space bilge. MI found that the audible and visual bilge high water alarm for the engine room are inoperable.
46 CFR 182.530(a)(2)
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in... A space with a through-hull fitting below the deepest load waterline, such as a lazarette. MI found that the visual bilge high water alarm for the Lazarette was inoperable.
46 CFR 182.530(a)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 January 2026
Resolved
The lights prescribed in these Rules shall have an intensity so as to be visible at the following minimum ranges... In a vessel of 12 meters or more in length but less than 50 meters in length... A sidelight, 2 miles. MI found that the Starboard running light is inoperable.
33 CFR 83.22(b)(ii)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 January 2026
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications... Each paddle must be... lashed to the life float to which it belongs and buoyant. MI found that the oars for two life floats were not lashed to their respective life floats.
46 CFR 180.175(f)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 January 2026
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. MI found that the vessel name on the oars for the life floats were too faded to be legible.
46 CFR 185.604(d)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2026
Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange. MI found that 3 of the 4 lifefloats were sun faded and no longer vivid reddish orange. Repaint lifefloats to the satisfaction of the MI.
46 CFR 160.010-4(n)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 January 2026
Resolved
Each ring life buoy on a vessel must... If on a vessel on an oceans or coastwise route, be orange in color. MI found that the life ring was sun faded and no longer orange. Repaint life ring orange to the satisfaction of the MI.
46 CFR 180.70(b)(5)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2026
Resolved
Each buoyant apparatus must have Type II retroreflective material... on each side and end. MI found that most of the retroreflective tape on the lifefloats was worn and faded.
46 CFR 160-010-4(p)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 January 2026
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. MI found that all 5 floating waterlight batteries on board were expired.
46 CFR 176.808(c)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2026
Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. MI found fuel oil in several spots on the starboard side of the fuel tank compartment. Pressure test the starboard fuel oil tank at next drydock to the satisfaction of the MI.
46 CFR 176.25-50(a)
(OLD T)
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 5 January 2026
Resolved
Scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. MI found severe cracking in the FRP above the seating located on the forecastle in front of the pilot house. Seal cracking at next drydock to the satisfaction of MI.
46 CFR 177.01-5
(OLD T)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI found a life jacket no longer fit for service.
46 CFR 176.808(b)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: External inspection of fuel tanks and inspection of tank vents, piping, and pipe fittings. Port fuel tank vent line in fuel void appears crushed by sideshell screw. Remove screw in part or whole to make vent line available for MI inspection.
46 CFR 176.804
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. Upper starboard 15 person life float found with broken grab line loops and a portion of the main body seem that was failing. Repair or replace life float.
46 CFR 176.808
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Bait tank piping in lazarette overhead is weeping around fiberglass to pipe connection and around overhead/deck connection. Provide repair details and affect proper repairs.
46 CFR 176.802
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2025
Resolved
On a vessel of at 26 feet, a visual and audible alarm must be provided at the operating station. MI observed fuel tank void bilge alarm not visually indicating at operating station.
46 CFR 182.530(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length provided that the pump is permanently mounted. MI observed submersible bilge pump in engine room was not mounted to the bilge.
46 CFR 182.520(e ) (3)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 February 2025
Resolved
Each vessel must have on board an EPIRB, installed to automatically float free and activate. MI observed HRU on EPIRB to be missing expiration date. Operator provided evidence of purchase/installation date and marked HRU with corresponding date.
46 CFR 180.64
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 February 2024
Resolved
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part: (1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Owner has not completed the worklist for credit drydock. Vessel has expired drydock and may not carry passengers until completing drydock worklist.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of fixed gas fire extinguishing system. During operational test of engine room pre-engineered fire fighting system, engines were able to restart without activating override function.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 February 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Underway portion and man overboard drill were not able to be completed due to firefighting discrepancy. Perform satisfactory man overboard drill and underway operational tests in the
presence of a marine inspector.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 February 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew training was not performed within the last 3 months.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 February 2024
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Servicing report for system was not available for inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Port engine exhaust piping had a water leak on the underside where the non metallic sleeve is clamped to the fiberglass.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2024
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeter (24 inches) in diameter. Ring buoy is worn, faded and needs replacement.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 13 February 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Expired items in first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There are unterminated wires under the helm console on starboard side.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 January 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts. Vessel representative completed temporary repair of inoperable collision bulkhead bilge pump. Complete permanent splice, connection to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 January 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Collision bulkhead bilge space high water alarm was inoperable and corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 17 January 2023
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Port light in STBD Head is missing fasteners to provide proper weather-tight closure. Provide means to properly close to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 January 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Vessel missing STBD fuel tank vent flame screen.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 January 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Buckets provided on vessel were too large. Procure fire buckets of proper size.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. (b) The records shall be sufficient to: (1) Satisfy the requirements of §§ 16.210(b) and 16.220(c) of this part. (2) Identify the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required by this part including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Provide records of chemical tests.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Risk evaluation, training and instruction to seafarers
Issued 17 January 2023
Resolved
For a vessel described by 46 CFR175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include all items referenced in this part. Provide required training and log into vessels training/drills logs.
Federal Register/V.86 No. 245 46 CFR 185.420
Federal Register/V.86 No. 245 46 CFR 185.420.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 February 2022
Resolved
Each hatch exposed to the weather must be watertight. Forward and aft watertight hatches leaked when exposed to water.
46 CFR 171.124(a) (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 March 2021
Resolved
The construction and arrangement of a vessel must allow for the safe operation of hte vessel in accordance with the terms of the COI giving consideration to provisions of a seaworthy hull. Vessel's main deck has two soft spots located in the vicinity of the lazarette hatch as well as by the starboard breezeway aft of the main house. The deck in these areas is not adequately supported. Submit a repair proposal with provisions to strengthen the deck in these two areas.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 February 2020
Resolved
Penetrations and openings in watertight bulkheads must have a means to keep them watertight. Several of the watertight bulkheads required for subdivision have wire and wire runs that are installed without a means to keep the bulkheads watertight. Vessel passenger count reduced to 49 or less until subdivision is met. Provide plan for approval to make bulkheads required for subdivision watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel. One adult life jacket was found not serviceable. Vessel limited to 70 adult passengers until life jacket is replaced. 46 CFR 180.71 (a)
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 April 2019
Resolved
An exposed hazard, such as rotating machinery must be properly protected by a cover, guard, or rail. Port and Starboard Main Diesel Engine's rotating shafting is not protected. 46 CFR 177.960
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
All machinery shall be installed and maintained to afford adequate protection against machinery failure. Fuel return line located on port fuel tank is cracking. 46 CFR 182.07-5
Engineering › Bilge Water Management System › Not Operational
Issued 13 February 2017
Resolved
Prove proper operation of lazarette bilge suction. 46 CFR "OLD T" 182.25-1.
Stability › Watertight Integrity › Coaming
Issued 13 February 2017
Resolved
Permanently remove 1" by 4" drainage hole from below aft deck house door. Vessel is on an Oceans route and required to have a 6" watertight coaming under a weather tight door.46 CFR "Old S" 171.124(d)
Lifesaving › Lifefloat › Serviceable
Issued 14 March 2014
Resolved
Renew life floats on board to international orange
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 March 2014
Resolved
Provide tournaquet for first aid kit.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 March 2014
Resolved
Provide 30x30 mesh flame screen for stbd fuel vent.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 8 December 2011
Resolved
Replace all expired waterlight batteries. 46 CFR 180.75
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2011
Resolved
Prive Aspirin for first aid kit. 46 CFR 160.041 (b)
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 November 2010
Resolved
Condemned (2) Adult and (2) Child PFDs. Provide (2) Adult and (1) Child PFDs. Limited to 69 Total Adults and 7 Children.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 23 November 2010
Resolved
Cable to SBD ME starter worn through insulation. Replace with new cable.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 November 2010
Resolved
Provide lifejacket placard for type carried onboard.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 November 2010
Resolved
Provide retroreflective tape on adult PFD where initialed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 23 November 2010
Resolved
Port and STBD clutch and throttle cables hang from overhead. Mount both cables in overhead without creating bends.
Lifesaving › Lifefloat › Paddle
Issued 23 November 2010
Resolved
Port LF paddles not lashed to float. Lash both paddles to float.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 November 2010
Resolved
Provide EPIRB registration from NOAA.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Company did not have result/exemptions for pre-employment testing prior for individuals working in a safety sensitive position, as required by 46 CFR 16.210.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 7 December 2009
Resolved
Prove proper operation of the single side band radio and provide emergency broadcast placard. Must be completed before operating greater than 20nm from shore.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 December 2009
Resolved
Replace missing second clamp on port engine exhaust piping.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 November 2007
Resolved
Prove proper operation of type I child lifejacket light.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 November 2007
Resolved
Properly install required amount of retro-reflective tape on installed ring lifebuoy.
Communications › Radio Communications › EPIRB
Issued 15 November 2007
Resolved
Provide onboard current NOAA registration for installed EPIRB.
Stability › Watertight Integrity › General
Issued 15 December 2005
Resolved
Make deck watertight in way of potable water fill connection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 December 2005
Resolved
Repair STBD running light in way of loose connection.
Lifesaving › Lifefloat › Float-free Link
Issued 15 December 2005
Resolved
Correctly install weak link to life floats.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 December 2005
Resolved
Replace lights on 8 of the adult PFD's and on 1 of the Childs PFD's.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 December 2005
Resolved
Replace defective and or missing retaining clips on 12 adult PFD's.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 November 2004
Resolved
Prove proper operation of automatic engine shutdowns associated with fixed fire extinguishing sytem
Lifesaving › Launching Appliances › Release Mechanism
Issued 18 November 2004
Resolved
Provide float free arrangement for EPIRB (Limited to not more than 3NM from shore)
Documentation › Logs/Records › Logbook (official)
Issued 18 November 2004
Resolved
Provide copy of senior deckhand designation letter IAW NVIC 1-91
Navigation › Piloting/Steering › Marine Charts
Issued 18 November 2004
Resolved
Provide current & corrected navigation charts onboard
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 November 2004
Resolved
Install Machinery guards for alternator belts and engine driven pumps on both port and starboard main engines IAW 46 CFR 177.960
Engineering › Freshwater Generation System › Piping
Issued 18 November 2004
Resolved
Install supports for following PVC piping in lazarette: (a) potable water tank vent line, (b) potable water tank suction line, and (c) supply line for deck wash down fitting
Electrical › Lighting (service) › Conductor
Issued 18 November 2004
Resolved
Properly secure wiring to engine room light fixture over starboard exhaust piping
Fire Fighting › Ventilation Systems › Ducts
Issued 18 November 2004
Resolved
Provide means to properly secure engine room ventilation
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 November 2004
Resolved
Make aft engine room bulkhead watertight in way of centerline wire run.
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 September 2004
Resolved
Wasted valve handles on 1 inch ball sea valve to shaft cooling. Port valve fell apart during inspection. Starboard valve appeared similarly wasted.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 September 2004
Resolved
Restore watertight integrity in cable runs between engine room and fuel tank space.
Electrical › Electric Supply System (service) › Cable
Issued 16 September 2004
Resolved
Add chaffing gear to prevent wear to cable run near port fuel tank.
Communications › Radio Communications
Issued 26 November 2002
Resolved
Replace as new EPIRB antenna. LEGACY COMPONENT DESC: EPIRB
Construction/Loadline › Structures
Issued 26 November 2002
Resolved
Make bulkhead between #2 void space and fuel tank space watertight as indicated by attending marine inspector. LEGACY COMPONENT DESC: Transverse Bulkhead
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 26 November 2002
Resolved
Replace as new 4 non operating life jacket lights.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 September 2002
Resolved
Adjust port main engine propellor shaft so shaft is not resting on metallic bearing retainer.
Engineering › Fuel Oil Storage/Transfer System
Issued 10 September 2002
Resolved
Repair as new and prove to the satisfaction of the attending marine inspector that both fuel oil tanks do not leak. Use 46 CFR 182.440(c) as a guide. LEGACY COMPONENT DESC: Tank
Construction/Loadline › Penetrations
Issued 10 September 2002
Resolved
Make all PVC piping penetrations in all watertight bulkheads watertight by complying with 46 CFR 182.720(d)(1).
Engineering › Bilge Water Management System
Issued 10 September 2002
Resolved
Renew bilge suction piping/fire pump piping suction line as required by 46 CFR 182.720(c)(1) due to corrosion. LEGACY COMPONENT DESC: Piping
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 September 2002
Resolved
Install motor mount bolts where found missing on port & starboard engine foundations. LEGACY COMPONENT DESC: Bedplate
Engineering › Bilge Water Management System
Issued 10 September 2002
Resolved
Install valve in bilge line to forward peak compartment as required by 46 CFR 182.25-5(d) Old "T" or 46 CFR 182.520(d) New "T" LEGACY COMPONENT DESC: Valve
Construction/Loadline › Penetrations
Issued 10 September 2002
Resolved
Remove thru hull penetration on starboard bow and patch hull using acceptable marine practice.
Construction/Loadline › Hull
Issued 10 September 2002
Resolved
Repair fwd collision bulkhead in way of fractured FRP cleat on aft port side of bulkhead.
Construction/Loadline › Hull
Issued 10 September 2002
Resolved
Repair as new the hull defect in way of the port propellor shaft.
Construction/Loadline › Penetrations
Issued 10 September 2002
Resolved
Repair as new MSD overboard hull connection.
Construction/Loadline › Structures
Issued 10 September 2002
Resolved
Remove watertight hatch/scuttle from fuel oil tank space and install scuttle on main deck. Restore bulkheads watertight integrity. LEGACY COMPONENT DESC: Transverse Bulkhead
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 December 2001
Resolved
Provide 2 PFD lights for adult life jackets. Vessel is restricted to 68 passengers (71 total persons) until PFD lights are provided. LEGACY COMPONENT DESC: Lights
Communications › Radio Communications
Issued 18 December 2001
Resolved
Provide an approved hydrostatic release for EPIRB. Vessel is restricted to not more than 3 miles from shore until this is corrected. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Lifebuoys
Issued 18 December 2001
Resolved
Install quick disconnect clip on ring buoy waterlight. Corrected on the spot LEGACY COMPONENT DESC: Buoyant Lifeline
Documentation › Certificates/Documents › Stability Letter
Issued 18 December 2001
Resolved
Relocate Stability Letter to Pilot House. Corrected on the spot.
Construction/Loadline
Issued 1 December 1999
Resolved
PROVIDE AUDIBLE ALARM FOR BILGE HIGH WATER ALARM IN ENGINE ROOM.
Construction/Loadline
Issued 3 December 1997
Resolved
SCRAPE AND TREAT FURRING ON TRANSVERSE DECK BEAM IN ENGINE ROOM.
Accommodation/Occupational Safety
Issued 3 December 1997
Resolved
REPAIR STANCHIONS FOR HANDRAILS.
Lifesaving
Issued 5 December 1996
Resolved
REPAIR REAR LIFEFLOAT (1 AREA).
Documentation
Issued 5 December 1996
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Navigation
Issued 5 December 1996
Resolved
PROVIDE COAST PILOT, LIGHT LIST, TIDES & CURRENTS TABLES, AND CURRENT CHARTS OF THE OPERATING AREA (CHARTS WERE 10+ YEARS OLD).
Accommodation/Occupational Safety
Issued 5 December 1996
Resolved
TIGHTEN RAILING AROUND AFT AND SIDES OF VESSEL.
Electrical
Issued 5 December 1996
Resolved
PROVIDE PLAN FOR BAIT PUMP INSTALLATION (ELECTRICAL LOAD, ETC).
Electrical
Issued 5 December 1996
Resolved
STRAIGHTEN WIRING UNDER BRIDGE CONSOLE. REMOVE ANY DEAD WIRES.
Lifesaving
Issued 5 December 1996
Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Accommodation/Occupational Safety
Issued 7 May 1996
Resolved
REFASTEN SCARFS IN TOP COURSE OF WOOD GUARD RAILS AT STBD BOW.
Accommodation/Occupational Safety
Issued 7 May 1996
Resolved
REPAIR DE-LAMINATED SECTION OF PORT SIDE GUARD RAIL AT STEPS TO BRIDGE WING.
Construction/Loadline
Issued 7 May 1996
Resolved
IN FOREPEAK, REPLACE AS ORIGINAL UPPER PORT CORNER CONNECTION OF AFT BULKHEAD.
Construction/Loadline
Issued 7 May 1996
Resolved
PROPERLY MOUNT BILGE LEVEL SENSOR FOR HIGH LEVEL ALARM IN ENG COMPT.
Construction/Loadline
Issued 7 May 1996
Resolved
REPLACE SEA VALVES FOR BAIT TANK SUCTION AND STBD HEAD FLUSH PUMP SUCTION.
Accommodation/Occupational Safety
Issued 7 May 1996
Resolved
PROPERLY MOUNT SANITARY PUMPS IN PORT AND STBD SIDE OF ENG COMPT.
Construction/Loadline
Issued 7 May 1996
Resolved
RE-INSTALL FLOAT SWITCH FOR ENG COMPT RULE TYPE BILGE PUMP.
Construction/Loadline
Issued 7 May 1996
Resolved
REMOVE OILY WATER FROM BILGE OF ENG COMPT.
Navigation
Issued 7 May 1996
Resolved
RENEW AS ORIGINAL THE PORT AND STBD STEERING ARM STOPS.
Engineering
Issued 25 August 1995
Resolved
CONDUCT U/W TEST IN PRESENCE OF USCG MARINE INSPECTOR AFTER COMPLETING REPAIR & LAGGING OF PORT STACK SYSTEM. COMPLETE PRIOR TO CARRYING PASSENGERS.
Navigation
Issued 18 January 1995
Resolved
INVESTIGATE AND REPAIR HYDRAULIC LEAK IN STEERING GEAR HYDRAULIC RAM.
Lifesaving
Issued 18 January 1995
Resolved
PROCURE THREE PFD LIGHTS.
Engineering
Issued 18 January 1995
Resolved
MARK FUEL SHUT-OFF VALUES WITH DIRECTIONAL ARROWS.
Lifesaving
Issued 18 January 1995
Resolved
PROCURE JUM BUOY REPAIR KIT AND REPAIR ALL BUOYANT APPARATI AND LIFE FLOATS.
Engineering
Issued 9 October 1994
Resolved
REPLACE CHARRED LAGGING AROUND PRT ENGINE EXHAUST.
Electrical
Issued 8 October 1994
Resolved
Unknown Component - Unknown Cause/Condition
Electrical
Issued 8 October 1994
Resolved
ELECTRICAL FIRE STARTED IN ENGINE ROOM WHEN A HYDRYLIC HOSE BURST AND SPRAYED HYDRAYLIC OIL ON TO ELECTRICAL REGULATOR. THE REGULATOR SHORTED OUT CAUSING FIRE.
Engineering
Issued 8 October 1994
Resolved
Unknown Component - Unknown Cause/Condition
Construction/Loadline
Issued 7 December 1993
Resolved
PLUG ALL WATERTIGHT BULKHEAD PENETRATIONS IN FIRST COMPARTMENT AFT OF COLLISION BULKHEAD.
Lifesaving
Issued 7 December 1993
Resolved
PROVIDE AN ADDITIONAL SEVEN LIGHTS FOR SEVEN LIFEJACKETS. VESSEL IS RESTRICTED TO CARRYING 54 PASSENGERS ON A LIMITED COATWISE ROUTE AND 23 PASSENGERS ON AN OCEANS ROUTE.
Lifesaving
Issued 7 December 1993
Resolved
REPAIR ALL HOLES ON BUOYANT APPARATUS AND BOTH LIFEFLOATS.
Lifesaving
Issued 7 December 1993
Resolved
REPLACE 100' PAINTER FOR LIFEFLOAT.
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE LIGHTS FOR 6 ADULT AND ONE CHILD PFD. VESSEL IS RESTRICTED TO CARRYING 57 ADULTS AND 6 CHILDREN.
Engineering
Issued 17 December 1992
Resolved
REPLACE FUEL VENT FLAME SCREEN ON STBD SIDE OF VESSEL.
Engineering
Issued 17 December 1992
Resolved
REPAIR/REPLACE FREEZE PLUG ON PORT ENGINE, 2ND FROM AFT OF ENGINE INBOARD.
Navigation
Issued 17 December 1992
Resolved
REPAIR/REPLACE ANCHOR LIGHT.
Construction/Loadline
Issued 17 December 1992
Resolved
PROVIDE SUFFICIENT HOSE TO OPERATE HAND FIRE/BILGE PUMP FROM MAIN DECK.
Lifesaving
Issued 12 December 1991
Resolved
PROVIDE BOAT HOOK TO ASSIST IN RECOVERY OF PERSON IN WATER._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 13 December 1990
Resolved
ROUTE IS LIMITED TO COASTWISE UNTIL EPIRB IS RETURNED TO SERVICE.
Lifesaving
Issued 5 January 1990
Resolved
PROVIDE AND INSTALL NEW BATERRIES IN LIFE PRESERVER LIGHTS. VESSEL,S ROUTE IS LIMITED TO 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS ITEM COMPLETED.
Navigation
Issued 5 January 1990
Resolved
EXAMINE AND REPLACE IF NEEDED, UPPER BEARINGS IN BOTH RUDDER POSTS. THIS ITEM TO BE COMPLETED AT NEXT DRY DOCK.
Accommodation/Occupational Safety
Issued 9 February 1989
Resolved
WIRE MSD OVERBOARD DISCHARGE VALVES ON PORT AND STARBOARD SIDES OF THE ENGINEROOM SHUT.
Engineering
Issued 9 February 1989
Resolved
TIGHTEN PORT SHAFT PACKING TO STOP EXCESSIVE LEAKAGE.
Construction/Loadline
Issued 9 February 1989
Resolved
REMOVE LATCH ON EMERGENCY EXIT ON BRIDGE AND PUT PULL HANDLE IN PASSENGER COMPARTMENT SO THAT EXIT CAN BE OPENED FROM PASSENGER COMPARTMENT.
Engineering
Issued 9 February 1989
Resolved
REPAIR VOLTAGE GAUGE ON PORT ENGINE.
Electrical
Issued 13 January 1988
Resolved
FIBERGLASS OR LEADLINE NEW BATTERY BOX LOCATED ON PORT SIDE OF ENGINEROOM.
Engineering
Issued 13 January 1988
Resolved
REPAIR FUEL LEAKS ON PORT AND STARBOARD FUEL TANKS.
Construction/Loadline
Issued 3 November 1987
Resolved
PROVIDE VALVES FOR EACH KEEL COOLER THROUGH HULL FITTING OR REMOVE FLEX CONNECTION AND HARD PIPE TO ABOVE THE WATERLINE.
Documentation
Issued 10 February 1987
Resolved
PROVIDE VALID FCC OPERATOR'S PERMIT.
Deck/Cargo
Issued 29 May 1985
Resolved
INSTALL, AS REQUIRED BY 46CFR182.25-5(D), SCREW-DOWN VALVE IN BILGE LINE NEAR COLLISION BULKHEAD.
Construction/Loadline
Issued 29 May 1985
Resolved
REPAIR UNDECK LONGITUDINAL IN ENGINE ROOM PORT SIDE, BY PROVIDING ADQUATE BRACE BETWEEN LONGITUDINAL AND TRANSVERSE DECK FRAME.
Lifesaving
Issued 24 January 1985
Resolved
PROVIDE 1 ADULT PFD.
Navigation
Issued 24 January 1985
Resolved
REPAIR AND PROVE OPERATION OF STERN LIGHT.
Casualty record · 2
8 July 2013Routine · role: Involved in a Marine Casualty · activity 4648350
27 July 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6511187
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.