STAR OF MONTEREY

STAR OF MONTEREY is a 1978 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1985, most recently in January 2026, along with 151 deficiencies, 3 operational controls and 2 casualty investigations between 2013 and 2018.

Records from 1985 to 2026. Most recent: inspection, 5 January 2026.

Built
1978
Last inspected
5 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD4204
Flag
UNITED STATES
367141650
Maury page id
psix-49913

Inspections, by type

…with no type recorded13
Years with a record 38 calendar years (1985–2026)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.7 ft × 19.1 ft × 8.0 ft
Registered tonnagegross 75 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY'S ENTERPRISES, INC · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 27 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD4204MMSI 367141650 · active · compulsorily equipped · granted 13 August 2026, expires 26 September 2036
WSX6716MMSI not assigned · expired · compulsorily equipped · granted 1 July 1996, cancelled 13 November 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 95

5 January 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8290044
12 February 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078501
15 February 2024 Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865108
13 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7853645
17 January 2023 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612570
23 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612391
22 February 2022 Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7400920
15 February 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7398461
4 March 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7150511
14 April 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939703
11 March 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6925011
25 February 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6912324
9 January 2019 Administrative Inspection · Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600802
27 July 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6511187
9 March 2018 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6369115
28 February 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6364351
13 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6087798
7 March 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828262
29 February 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5835402
18 March 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816410
10 March 2014 Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4813596
7 December 2011 Simplified Stability Test · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4204403
21 September 2011 Type not recorded
No type recorded · Station Monterey · USCG Southwest District (CGD-SW) · Activity 4153333
23 November 2010 Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3896337
15 December 2009 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3651449
7 December 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3643985
17 December 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3380260
2 December 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3369951
15 November 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3089821
6 December 2005 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2546881
30 March 2005 Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2322561
10 December 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2256332
26 November 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2248315
18 November 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2221121
18 November 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2244283
16 September 2004 Internal Structural Exam · Drydock Extension
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2176229
15 March 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2025087
4 December 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1960811
6 May 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1777964
28 January 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1736533
10 December 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1717015
26 November 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1710424
10 September 2002 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1671246
26 December 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1473771
18 December 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1474864
22 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076202
14 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382153
1 August 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1401288
5 January 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1046813
1 December 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1457719
26 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126025
24 February 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 778864
24 February 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806909
21 January 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787798
1 December 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805358
19 December 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1120714
3 December 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400683
29 January 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103158
5 December 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413091
2 July 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1086749
7 May 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1082709
13 December 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189662
25 August 1995 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879351
19 August 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 117155
30 May 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 873412
7 February 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148926
18 January 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871125
15 December 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146325
9 October 1994 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172552
8 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 125884
22 December 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1162973
7 December 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083827
7 December 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159616
8 January 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 840466
17 December 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132406
23 September 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942125
30 January 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 946286
12 December 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 944859
8 February 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216403
13 December 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225424
15 November 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924862
12 September 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923575
4 May 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216730
5 January 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234758
24 May 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 896099
23 February 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044192
9 February 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342570
13 January 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012233
3 November 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328489
10 February 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012477
1 October 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313017
2 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1029770
1 August 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290762
29 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290914
24 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 972766

Deficiency record · 151

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 January 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. MI found that the bilge pump piping is corroded causing low F/M pressure and back flooding into the engine room bilge when the pump is operational. Patch corroded piping and then replace it at the next drydock to the satisfaction of MI. 46 CFR 185.25-1(a) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2026
Resolution: Operator provided photos of correction. See Documents- "Bilge Pump Piping Replacement: Star of Monterey 05Jan26 Annual Exam"
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2026 Resolved
Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. MI discovered Fuel Oil leak on the starboard fuel tank intake pipe. Replace starboard intake pipe to the satisfaction of the MI. 46 CFR 182.20-30(b) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI pictures of fill line replacement and installation.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in... A machinery space bilge. MI found that the audible and visual bilge high water alarm for the engine room are inoperable. 46 CFR 182.530(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI video of the audio and visual alarm working from the operating station.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in... A space with a through-hull fitting below the deepest load waterline, such as a lazarette. MI found that the visual bilge high water alarm for the Lazarette was inoperable. 46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI video of Lazarette visual and audible working from the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 January 2026 Resolved
The lights prescribed in these Rules shall have an intensity so as to be visible at the following minimum ranges... In a vessel of 12 meters or more in length but less than 50 meters in length... A sidelight, 2 miles. MI found that the Starboard running light is inoperable. 33 CFR 83.22(b)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI a picture of the starboard running light turned on and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 January 2026 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications... Each paddle must be... lashed to the life float to which it belongs and buoyant. MI found that the oars for two life floats were not lashed to their respective life floats. 46 CFR 180.175(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI pictures of oars lashed to their respective life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 January 2026 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. MI found that the vessel name on the oars for the life floats were too faded to be legible. 46 CFR 185.604(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI a picture of the faded oars relabeled.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2026 Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange. MI found that 3 of the 4 lifefloats were sun faded and no longer vivid reddish orange. Repaint lifefloats to the satisfaction of the MI. 46 CFR 160.010-4(n)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 18 February 2026
Resolution: Operator provided MI with pictures of the lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 January 2026 Resolved
Each ring life buoy on a vessel must... If on a vessel on an oceans or coastwise route, be orange in color. MI found that the life ring was sun faded and no longer orange. Repaint life ring orange to the satisfaction of the MI. 46 CFR 180.70(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 12 January 2026
Resolution: MI observed that life ring has been repainted
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2026 Resolved
Each buoyant apparatus must have Type II retroreflective material... on each side and end. MI found that most of the retroreflective tape on the lifefloats was worn and faded. 46 CFR 160-010-4(p)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 18 February 2026
Resolution: Operator provided MI with pictures of lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 January 2026 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. MI found that all 5 floating waterlight batteries on board were expired. 46 CFR 176.808(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 18 February 2026
Resolution: Operator provided MI with pictures of the new waterlight batteries.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2026 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. MI found fuel oil in several spots on the starboard side of the fuel tank compartment. Pressure test the starboard fuel oil tank at next drydock to the satisfaction of the MI. 46 CFR 176.25-50(a) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2026
Resolution: Operator filled fuel tank with fuel. No excess accumulation of fuel found in bilge or compartment.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 5 January 2026 Resolved
Scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. MI found severe cracking in the FRP above the seating located on the forecastle in front of the pilot house. Seal cracking at next drydock to the satisfaction of MI. 46 CFR 177.01-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2026
Resolution: Operator provided photos of correction. See "FRP Cracking – Star of Monterey Annual Inspection 05JAN26" in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI found a life jacket no longer fit for service. 46 CFR 176.808(b)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 5 January 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: External inspection of fuel tanks and inspection of tank vents, piping, and pipe fittings. Port fuel tank vent line in fuel void appears crushed by sideshell screw. Remove screw in part or whole to make vent line available for MI inspection. 46 CFR 176.804
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed screw removed. No damage to adjacent piping was found.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. Upper starboard 15 person life float found with broken grab line loops and a portion of the main body seem that was failing. Repair or replace life float. 46 CFR 176.808
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Lifefloat onboard was inspected and in servicable condition.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Bait tank piping in lazarette overhead is weeping around fiberglass to pipe connection and around overhead/deck connection. Provide repair details and affect proper repairs. 46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed repair to pipe penetration. No water intrusion observed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2025 Resolved
On a vessel of at 26 feet, a visual and audible alarm must be provided at the operating station. MI observed fuel tank void bilge alarm not visually indicating at operating station. 46 CFR 182.530(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed bilge alarm visual indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length provided that the pump is permanently mounted. MI observed submersible bilge pump in engine room was not mounted to the bilge. 46 CFR 182.520(e ) (3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed submersible bilge pump mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 February 2025 Resolved
Each vessel must have on board an EPIRB, installed to automatically float free and activate. MI observed HRU on EPIRB to be missing expiration date. Operator provided evidence of purchase/installation date and marked HRU with corresponding date. 46 CFR 180.64
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 February 2025
Resolution: Operator provided evidence of purchase date and marked HRU in MI presence.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 February 2024 Resolved
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part: (1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Owner has not completed the worklist for credit drydock. Vessel has expired drydock and may not carry passengers until completing drydock worklist.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Drydock inspection complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of fixed gas fire extinguishing system. During operational test of engine room pre-engineered fire fighting system, engines were able to restart without activating override function.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2024
Resolved 28 March 2024
Resolution: Verified operation of system.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 February 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Underway portion and man overboard drill were not able to be completed due to firefighting discrepancy. Perform satisfactory man overboard drill and underway operational tests in the presence of a marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 February 2024
Resolved 3 April 2024
Resolution: Extended to coincide with MI attendance. 03APR2024: Conducted man overboard drill and underway operation tests.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 February 2024 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew training was not performed within the last 3 months.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 24 March 2024
Resolution: Verified updated training.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 February 2024 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Servicing report for system was not available for inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 15 February 2024
Resolution: Report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Port engine exhaust piping had a water leak on the underside where the non metallic sleeve is clamped to the fiberglass.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 3 April 2024
Resolution: Visually inspected machinery space while underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2024 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeter (24 inches) in diameter. Ring buoy is worn, faded and needs replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 26 February 2024
Resolution: Accepted photo of replaced life buoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 13 February 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Expired items in first aid kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 24 March 2024
Resolution: Verified updated first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There are unterminated wires under the helm console on starboard side.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 February 2024
Resolved 13 February 2024
Resolution: Wire correctly terminated during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 January 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts. Vessel representative completed temporary repair of inoperable collision bulkhead bilge pump. Complete permanent splice, connection to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified proper connection for bilge pump wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 January 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Collision bulkhead bilge space high water alarm was inoperable and corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 January 2023
Resolved 17 January 2023
Resolution: Witnessed sat operation of bilge alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 17 January 2023 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Port light in STBD Head is missing fasteners to provide proper weather-tight closure. Provide means to properly close to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified proper closures for portholes.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 January 2023 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Vessel missing STBD fuel tank vent flame screen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified stbd flame screen.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 January 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Buckets provided on vessel were too large. Procure fire buckets of proper size.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified properly sized buckets onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. (b) The records shall be sufficient to: (1) Satisfy the requirements of §§ 16.210(b) and 16.220(c) of this part. (2) Identify the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required by this part including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Provide records of chemical tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Completed company DAPI audit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Risk evaluation, training and instruction to seafarers
Issued 17 January 2023 Resolved
For a vessel described by 46 CFR175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include all items referenced in this part. Provide required training and log into vessels training/drills logs. Federal Register/V.86 No. 245 46 CFR 185.420 Federal Register/V.86 No. 245 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 1 February 2023
Resolution: Captain provided sat training log.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 February 2022 Resolved
Each hatch exposed to the weather must be watertight. Forward and aft watertight hatches leaked when exposed to water. 46 CFR 171.124(a) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 February 2022
Resolution: New gasket placed on hatches to perform more sufficent seal.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 March 2021 Resolved
The construction and arrangement of a vessel must allow for the safe operation of hte vessel in accordance with the terms of the COI giving consideration to provisions of a seaworthy hull. Vessel's main deck has two soft spots located in the vicinity of the lazarette hatch as well as by the starboard breezeway aft of the main house. The deck in these areas is not adequately supported. Submit a repair proposal with provisions to strengthen the deck in these two areas.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2021
Resolved 12 March 2021
Resolution: Vessel provided repair photos and submitted a statement to effectiveness of repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 February 2020 Resolved
Penetrations and openings in watertight bulkheads must have a means to keep them watertight. Several of the watertight bulkheads required for subdivision have wire and wire runs that are installed without a means to keep the bulkheads watertight. Vessel passenger count reduced to 49 or less until subdivision is met. Provide plan for approval to make bulkheads required for subdivision watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 March 2020
Resolution: The numerous penetrations through the watertight bulkheads were professionally sealed using a fire-rated sealant. The penetration were sealed to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2019 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One adult life jacket was found not serviceable. Vessel limited to 70 adult passengers until life jacket is replaced. 46 CFR 180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2019
Resolution: Vessel added 1 adult life jacket.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 April 2019 Resolved
An exposed hazard, such as rotating machinery must be properly protected by a cover, guard, or rail. Port and Starboard Main Diesel Engine's rotating shafting is not protected. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Shaft guards were provided over both port and starboard shafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019 Resolved
All machinery shall be installed and maintained to afford adequate protection against machinery failure. Fuel return line located on port fuel tank is cracking. 46 CFR 182.07-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Fuel return line replaced with SAE 1942 hose.
Engineering › Bilge Water Management System › Not Operational
Issued 13 February 2017 Resolved
Prove proper operation of lazarette bilge suction. 46 CFR "OLD T" 182.25-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2017
Resolved 14 February 2017
Resolution: Bilge suction satisfactorily tested in Lazarette and forepeak.
Stability › Watertight Integrity › Coaming
Issued 13 February 2017 Resolved
Permanently remove 1" by 4" drainage hole from below aft deck house door. Vessel is on an Oceans route and required to have a 6" watertight coaming under a weather tight door.46 CFR "Old S" 171.124(d)
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 9 March 2017
Resolution: Repaired 1"x4" hole in coaming.
Lifesaving › Lifefloat › Serviceable
Issued 14 March 2014 Resolved
Renew life floats on board to international orange
Due 18 April 2014
Resolved 7 April 2014
Resolution: Renewed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 March 2014 Resolved
Provide tournaquet for first aid kit.
Due 1 April 2014
Resolved 26 March 2014
Resolution: Provided
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 March 2014 Resolved
Provide 30x30 mesh flame screen for stbd fuel vent.
Due 1 April 2014
Resolved 27 March 2014
Resolution: Provided
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 8 December 2011 Resolved
Replace all expired waterlight batteries. 46 CFR 180.75
Condition: Improper/Lack of Maintenance
Due 7 January 2012
Resolved 8 December 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2011 Resolved
Prive Aspirin for first aid kit. 46 CFR 160.041 (b)
Condition: Improper/Lack of Maintenance
Due 7 January 2012
Resolved 8 December 2011
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 November 2010 Resolved
Condemned (2) Adult and (2) Child PFDs. Provide (2) Adult and (1) Child PFDs. Limited to 69 Total Adults and 7 Children.
Due 2 December 2010
Resolved 2 December 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 23 November 2010 Resolved
Cable to SBD ME starter worn through insulation. Replace with new cable.
Due 15 December 2010
Resolved 2 December 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 November 2010 Resolved
Provide lifejacket placard for type carried onboard.
Due 2 December 2010
Resolved 2 December 2010
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 November 2010 Resolved
Provide retroreflective tape on adult PFD where initialed.
Due 2 December 2010
Resolved 2 December 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 23 November 2010 Resolved
Port and STBD clutch and throttle cables hang from overhead. Mount both cables in overhead without creating bends.
Due 2 December 2010
Resolved 2 December 2010
Lifesaving › Lifefloat › Paddle
Issued 23 November 2010 Resolved
Port LF paddles not lashed to float. Lash both paddles to float.
Due 2 December 2010
Resolved 2 December 2010
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 November 2010 Resolved
Provide EPIRB registration from NOAA.
Due 15 December 2010
Resolved 2 December 2010
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Company did not have result/exemptions for pre-employment testing prior for individuals working in a safety sensitive position, as required by 46 CFR 16.210.
Due 15 January 2010
Resolved 16 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 15 January 2010
Resolved 15 December 2009
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 7 December 2009 Resolved
Prove proper operation of the single side band radio and provide emergency broadcast placard. Must be completed before operating greater than 20nm from shore.
Action required: 705 - Other - as specified
Resolved 26 February 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 December 2009 Resolved
Replace missing second clamp on port engine exhaust piping.
Due 31 December 2009
Resolved 17 December 2009
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 November 2007 Resolved
Prove proper operation of type I child lifejacket light.
Due 15 November 2007
Resolved 15 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 November 2007 Resolved
Properly install required amount of retro-reflective tape on installed ring lifebuoy.
Due 15 November 2007
Resolved 15 November 2007
Communications › Radio Communications › EPIRB
Issued 15 November 2007 Resolved
Provide onboard current NOAA registration for installed EPIRB.
Due 15 November 2007
Resolved 15 November 2007
Stability › Watertight Integrity › General
Issued 15 December 2005 Resolved
Make deck watertight in way of potable water fill connection.
Action required: 705 - Other - as specified
Resolved 15 December 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 December 2005 Resolved
Repair STBD running light in way of loose connection.
Action required: 705 - Other - as specified
Resolved 15 December 2005
Lifesaving › Lifefloat › Float-free Link
Issued 15 December 2005 Resolved
Correctly install weak link to life floats.
Action required: 705 - Other - as specified
Resolved 15 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 December 2005 Resolved
Replace lights on 8 of the adult PFD's and on 1 of the Childs PFD's.
Action required: 705 - Other - as specified
Resolved 15 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 December 2005 Resolved
Replace defective and or missing retaining clips on 12 adult PFD's.
Action required: 705 - Other - as specified
Resolved 15 December 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 November 2004 Resolved
Prove proper operation of automatic engine shutdowns associated with fixed fire extinguishing sytem
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2004
Lifesaving › Launching Appliances › Release Mechanism
Issued 18 November 2004 Resolved
Provide float free arrangement for EPIRB (Limited to not more than 3NM from shore)
Condition: Unknown
Due 18 December 2004
Resolved 24 November 2004
Documentation › Logs/Records › Logbook (official)
Issued 18 November 2004 Resolved
Provide copy of senior deckhand designation letter IAW NVIC 1-91
Condition: Unknown
Due 8 December 2004
Resolved 24 November 2004
Navigation › Piloting/Steering › Marine Charts
Issued 18 November 2004 Resolved
Provide current & corrected navigation charts onboard
Condition: Improper/Lack of Maintenance
Due 18 December 2004
Resolved 24 November 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 November 2004 Resolved
Install Machinery guards for alternator belts and engine driven pumps on both port and starboard main engines IAW 46 CFR 177.960
Condition: Unknown
Due 18 December 2004
Resolved 10 December 2004
Engineering › Freshwater Generation System › Piping
Issued 18 November 2004 Resolved
Install supports for following PVC piping in lazarette: (a) potable water tank vent line, (b) potable water tank suction line, and (c) supply line for deck wash down fitting
Condition: Improper Installation
Due 8 December 2004
Resolved 24 November 2004
Electrical › Lighting (service) › Conductor
Issued 18 November 2004 Resolved
Properly secure wiring to engine room light fixture over starboard exhaust piping
Condition: Unknown
Due 8 December 2004
Resolved 24 November 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 18 November 2004 Resolved
Provide means to properly secure engine room ventilation
Condition: Unknown
Due 8 December 2004
Resolved 24 November 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 November 2004 Resolved
Make aft engine room bulkhead watertight in way of centerline wire run.
Due 5 November 2004
Resolved 5 November 2004
Resolution: Correct on spot.
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 September 2004 Resolved
Wasted valve handles on 1 inch ball sea valve to shaft cooling. Port valve fell apart during inspection. Starboard valve appeared similarly wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2004
Resolved 16 September 2004
Resolution: Replaced with new
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 September 2004 Resolved
Restore watertight integrity in cable runs between engine room and fuel tank space.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 16 September 2004
Resolution: Restored
Electrical › Electric Supply System (service) › Cable
Issued 16 September 2004 Resolved
Add chaffing gear to prevent wear to cable run near port fuel tank.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 16 September 2004
Resolution: Chaffing gear added
Communications › Radio Communications
Issued 26 November 2002 Resolved
Replace as new EPIRB antenna. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2002
Resolution: Copy of recept for purchase of new antenna provided.
Construction/Loadline › Structures
Issued 26 November 2002 Resolved
Make bulkhead between #2 void space and fuel tank space watertight as indicated by attending marine inspector. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 1 January 2003
Resolved 9 January 2003
Resolution: Witnessed repairs to bulkhead between #2 void space and fuel tank space.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 26 November 2002 Resolved
Replace as new 4 non operating life jacket lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 September 2002 Resolved
Adjust port main engine propellor shaft so shaft is not resting on metallic bearing retainer.
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 12 November 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 10 September 2002 Resolved
Repair as new and prove to the satisfaction of the attending marine inspector that both fuel oil tanks do not leak. Use 46 CFR 182.440(c) as a guide. LEGACY COMPONENT DESC: Tank
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 20 September 2002
Construction/Loadline › Penetrations
Issued 10 September 2002 Resolved
Make all PVC piping penetrations in all watertight bulkheads watertight by complying with 46 CFR 182.720(d)(1).
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 26 November 2002
Engineering › Bilge Water Management System
Issued 10 September 2002 Resolved
Renew bilge suction piping/fire pump piping suction line as required by 46 CFR 182.720(c)(1) due to corrosion. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 20 September 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 September 2002 Resolved
Install motor mount bolts where found missing on port & starboard engine foundations. LEGACY COMPONENT DESC: Bedplate
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 20 September 2002
Engineering › Bilge Water Management System
Issued 10 September 2002 Resolved
Install valve in bilge line to forward peak compartment as required by 46 CFR 182.25-5(d) Old "T" or 46 CFR 182.520(d) New "T" LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 20 September 2002
Construction/Loadline › Penetrations
Issued 10 September 2002 Resolved
Remove thru hull penetration on starboard bow and patch hull using acceptable marine practice.
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 20 September 2002
Construction/Loadline › Hull
Issued 10 September 2002 Resolved
Repair fwd collision bulkhead in way of fractured FRP cleat on aft port side of bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2002
Construction/Loadline › Hull
Issued 10 September 2002 Resolved
Repair as new the hull defect in way of the port propellor shaft.
Due 10 September 2002
Resolved 10 September 2002
Construction/Loadline › Penetrations
Issued 10 September 2002 Resolved
Repair as new MSD overboard hull connection.
Due 10 September 2002
Resolved 10 September 2002
Construction/Loadline › Structures
Issued 10 September 2002 Resolved
Remove watertight hatch/scuttle from fuel oil tank space and install scuttle on main deck. Restore bulkheads watertight integrity. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 6 May 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 December 2001 Resolved
Provide 2 PFD lights for adult life jackets. Vessel is restricted to 68 passengers (71 total persons) until PFD lights are provided. LEGACY COMPONENT DESC: Lights
Condition: Placed in Improper Service
Due 18 January 2002
Resolved 2 January 2002
Communications › Radio Communications
Issued 18 December 2001 Resolved
Provide an approved hydrostatic release for EPIRB. Vessel is restricted to not more than 3 miles from shore until this is corrected. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 18 January 2002
Resolved 2 January 2002
Lifesaving › Lifebuoys
Issued 18 December 2001 Resolved
Install quick disconnect clip on ring buoy waterlight. Corrected on the spot LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Due 18 December 2001
Resolved 18 December 2001
Documentation › Certificates/Documents › Stability Letter
Issued 18 December 2001 Resolved
Relocate Stability Letter to Pilot House. Corrected on the spot.
Condition: Improper Installation
Due 18 December 2001
Resolved 18 December 2001
Construction/Loadline
Issued 1 December 1999 Resolved
PROVIDE AUDIBLE ALARM FOR BILGE HIGH WATER ALARM IN ENGINE ROOM.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 3 December 1997 Resolved
SCRAPE AND TREAT FURRING ON TRANSVERSE DECK BEAM IN ENGINE ROOM.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Accommodation/Occupational Safety
Issued 3 December 1997 Resolved
REPAIR STANCHIONS FOR HANDRAILS.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Lifesaving
Issued 5 December 1996 Resolved
REPAIR REAR LIFEFLOAT (1 AREA).
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Documentation
Issued 5 December 1996 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Navigation
Issued 5 December 1996 Resolved
PROVIDE COAST PILOT, LIGHT LIST, TIDES & CURRENTS TABLES, AND CURRENT CHARTS OF THE OPERATING AREA (CHARTS WERE 10+ YEARS OLD).
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Accommodation/Occupational Safety
Issued 5 December 1996 Resolved
TIGHTEN RAILING AROUND AFT AND SIDES OF VESSEL.
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Electrical
Issued 5 December 1996 Resolved
PROVIDE PLAN FOR BAIT PUMP INSTALLATION (ELECTRICAL LOAD, ETC).
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Electrical
Issued 5 December 1996 Resolved
STRAIGHTEN WIRING UNDER BRIDGE CONSOLE. REMOVE ANY DEAD WIRES.
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Lifesaving
Issued 5 December 1996 Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 5 December 1996
Resolved 5 December 1996
Accommodation/Occupational Safety
Issued 7 May 1996 Resolved
REFASTEN SCARFS IN TOP COURSE OF WOOD GUARD RAILS AT STBD BOW.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Accommodation/Occupational Safety
Issued 7 May 1996 Resolved
REPAIR DE-LAMINATED SECTION OF PORT SIDE GUARD RAIL AT STEPS TO BRIDGE WING.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Construction/Loadline
Issued 7 May 1996 Resolved
IN FOREPEAK, REPLACE AS ORIGINAL UPPER PORT CORNER CONNECTION OF AFT BULKHEAD.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Construction/Loadline
Issued 7 May 1996 Resolved
PROPERLY MOUNT BILGE LEVEL SENSOR FOR HIGH LEVEL ALARM IN ENG COMPT.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Construction/Loadline
Issued 7 May 1996 Resolved
REPLACE SEA VALVES FOR BAIT TANK SUCTION AND STBD HEAD FLUSH PUMP SUCTION.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Accommodation/Occupational Safety
Issued 7 May 1996 Resolved
PROPERLY MOUNT SANITARY PUMPS IN PORT AND STBD SIDE OF ENG COMPT.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Construction/Loadline
Issued 7 May 1996 Resolved
RE-INSTALL FLOAT SWITCH FOR ENG COMPT RULE TYPE BILGE PUMP.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Construction/Loadline
Issued 7 May 1996 Resolved
REMOVE OILY WATER FROM BILGE OF ENG COMPT.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Navigation
Issued 7 May 1996 Resolved
RENEW AS ORIGINAL THE PORT AND STBD STEERING ARM STOPS.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 25 August 1995 Resolved
CONDUCT U/W TEST IN PRESENCE OF USCG MARINE INSPECTOR AFTER COMPLETING REPAIR & LAGGING OF PORT STACK SYSTEM. COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 August 1995
Resolved 18 September 1995
Navigation
Issued 18 January 1995 Resolved
INVESTIGATE AND REPAIR HYDRAULIC LEAK IN STEERING GEAR HYDRAULIC RAM.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Lifesaving
Issued 18 January 1995 Resolved
PROCURE THREE PFD LIGHTS.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Engineering
Issued 18 January 1995 Resolved
MARK FUEL SHUT-OFF VALUES WITH DIRECTIONAL ARROWS.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Lifesaving
Issued 18 January 1995 Resolved
PROCURE JUM BUOY REPAIR KIT AND REPAIR ALL BUOYANT APPARATI AND LIFE FLOATS.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Engineering
Issued 9 October 1994 Resolved
REPLACE CHARRED LAGGING AROUND PRT ENGINE EXHAUST.
Condition: Unknown
Due 9 October 1994
Resolved 9 October 1994
Electrical
Issued 8 October 1994 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Resolution: CLEARED
Electrical
Issued 8 October 1994 Resolved
ELECTRICAL FIRE STARTED IN ENGINE ROOM WHEN A HYDRYLIC HOSE BURST AND SPRAYED HYDRAYLIC OIL ON TO ELECTRICAL REGULATOR. THE REGULATOR SHORTED OUT CAUSING FIRE.
Condition: Unknown
Due 8 January 2002
Resolved 3 February 2002
Resolution: CLEARED
Engineering
Issued 8 October 1994 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Resolution: CLEARED
Construction/Loadline
Issued 7 December 1993 Resolved
PLUG ALL WATERTIGHT BULKHEAD PENETRATIONS IN FIRST COMPARTMENT AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Lifesaving
Issued 7 December 1993 Resolved
PROVIDE AN ADDITIONAL SEVEN LIGHTS FOR SEVEN LIFEJACKETS. VESSEL IS RESTRICTED TO CARRYING 54 PASSENGERS ON A LIMITED COATWISE ROUTE AND 23 PASSENGERS ON AN OCEANS ROUTE.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Lifesaving
Issued 7 December 1993 Resolved
REPAIR ALL HOLES ON BUOYANT APPARATUS AND BOTH LIFEFLOATS.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Lifesaving
Issued 7 December 1993 Resolved
REPLACE 100' PAINTER FOR LIFEFLOAT.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Lifesaving
Issued 17 December 1992 Resolved
PROVIDE LIGHTS FOR 6 ADULT AND ONE CHILD PFD. VESSEL IS RESTRICTED TO CARRYING 57 ADULTS AND 6 CHILDREN.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Engineering
Issued 17 December 1992 Resolved
REPLACE FUEL VENT FLAME SCREEN ON STBD SIDE OF VESSEL.
Condition: Unknown
Due 15 January 1993
Resolved 21 December 1992
Engineering
Issued 17 December 1992 Resolved
REPAIR/REPLACE FREEZE PLUG ON PORT ENGINE, 2ND FROM AFT OF ENGINE INBOARD.
Condition: Unknown
Due 15 January 1993
Resolved 21 December 1992
Navigation
Issued 17 December 1992 Resolved
REPAIR/REPLACE ANCHOR LIGHT.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Construction/Loadline
Issued 17 December 1992 Resolved
PROVIDE SUFFICIENT HOSE TO OPERATE HAND FIRE/BILGE PUMP FROM MAIN DECK.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Lifesaving
Issued 12 December 1991 Resolved
PROVIDE BOAT HOOK TO ASSIST IN RECOVERY OF PERSON IN WATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Navigation
Issued 13 December 1990 Resolved
ROUTE IS LIMITED TO COASTWISE UNTIL EPIRB IS RETURNED TO SERVICE.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Lifesaving
Issued 5 January 1990 Resolved
PROVIDE AND INSTALL NEW BATERRIES IN LIFE PRESERVER LIGHTS. VESSEL,S ROUTE IS LIMITED TO 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Navigation
Issued 5 January 1990 Resolved
EXAMINE AND REPLACE IF NEEDED, UPPER BEARINGS IN BOTH RUDDER POSTS. THIS ITEM TO BE COMPLETED AT NEXT DRY DOCK.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Accommodation/Occupational Safety
Issued 9 February 1989 Resolved
WIRE MSD OVERBOARD DISCHARGE VALVES ON PORT AND STARBOARD SIDES OF THE ENGINEROOM SHUT.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Engineering
Issued 9 February 1989 Resolved
TIGHTEN PORT SHAFT PACKING TO STOP EXCESSIVE LEAKAGE.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Construction/Loadline
Issued 9 February 1989 Resolved
REMOVE LATCH ON EMERGENCY EXIT ON BRIDGE AND PUT PULL HANDLE IN PASSENGER COMPARTMENT SO THAT EXIT CAN BE OPENED FROM PASSENGER COMPARTMENT.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Engineering
Issued 9 February 1989 Resolved
REPAIR VOLTAGE GAUGE ON PORT ENGINE.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Electrical
Issued 13 January 1988 Resolved
FIBERGLASS OR LEADLINE NEW BATTERY BOX LOCATED ON PORT SIDE OF ENGINEROOM.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Engineering
Issued 13 January 1988 Resolved
REPAIR FUEL LEAKS ON PORT AND STARBOARD FUEL TANKS.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Construction/Loadline
Issued 3 November 1987 Resolved
PROVIDE VALVES FOR EACH KEEL COOLER THROUGH HULL FITTING OR REMOVE FLEX CONNECTION AND HARD PIPE TO ABOVE THE WATERLINE.
Condition: Unknown
Due 3 November 1987
Resolved 3 November 1987
Documentation
Issued 10 February 1987 Resolved
PROVIDE VALID FCC OPERATOR'S PERMIT.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Deck/Cargo
Issued 29 May 1985 Resolved
INSTALL, AS REQUIRED BY 46CFR182.25-5(D), SCREW-DOWN VALVE IN BILGE LINE NEAR COLLISION BULKHEAD.
Condition: Unknown
Due 29 May 1985
Resolved 29 May 1985
Construction/Loadline
Issued 29 May 1985 Resolved
REPAIR UNDECK LONGITUDINAL IN ENGINE ROOM PORT SIDE, BY PROVIDING ADQUATE BRACE BETWEEN LONGITUDINAL AND TRANSVERSE DECK FRAME.
Condition: Unknown
Due 29 May 1985
Resolved 29 May 1985
Lifesaving
Issued 24 January 1985 Resolved
PROVIDE 1 ADULT PFD.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Navigation
Issued 24 January 1985 Resolved
REPAIR AND PROVE OPERATION OF STERN LIGHT.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985

Casualty record · 2

8 July 2013Routine · role: Involved in a Marine Casualty · activity 4648350
27 July 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6511187
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.