STAR OF MONTEREY

Built
1978
Last inspected
5 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD4204
Flag
UNITED STATES
Maury page id
psix-49913

Documentation record

Registered dimensions (L × B × D)61.7 ft × 19.1 ft × 8.0 ft
Registered tonnagegross 75 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY'S ENTERPRISES, INC · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 27 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 44 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

5 January 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8290044
12 February 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078501
15 February 2024 Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865108
13 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7853645
17 January 2023 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612570
23 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612391
22 February 2022 Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7400920
15 February 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7398461
4 March 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7150511
14 April 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939703
11 March 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6925011
25 February 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6912324
9 January 2019 Administrative Inspection · Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600802
27 July 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6511187
9 March 2018 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6369115
28 February 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6364351
13 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6087798
7 March 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828262
29 February 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5835402

Deficiency record · 44

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 January 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. MI found that the bilge pump piping is corroded causing low F/M pressure and back flooding into the engine room bilge when the pump is operational. Patch corroded piping and then replace it at the next drydock to the satisfaction of MI. 46 CFR 185.25-1(a) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2026
Resolution: Operator provided photos of correction. See Documents- "Bilge Pump Piping Replacement: Star of Monterey 05Jan26 Annual Exam"
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2026 Resolved
Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. MI discovered Fuel Oil leak on the starboard fuel tank intake pipe. Replace starboard intake pipe to the satisfaction of the MI. 46 CFR 182.20-30(b) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI pictures of fill line replacement and installation.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in... A machinery space bilge. MI found that the audible and visual bilge high water alarm for the engine room are inoperable. 46 CFR 182.530(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI video of the audio and visual alarm working from the operating station.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in... A space with a through-hull fitting below the deepest load waterline, such as a lazarette. MI found that the visual bilge high water alarm for the Lazarette was inoperable. 46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI video of Lazarette visual and audible working from the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 January 2026 Resolved
The lights prescribed in these Rules shall have an intensity so as to be visible at the following minimum ranges... In a vessel of 12 meters or more in length but less than 50 meters in length... A sidelight, 2 miles. MI found that the Starboard running light is inoperable. 33 CFR 83.22(b)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI a picture of the starboard running light turned on and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 January 2026 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications... Each paddle must be... lashed to the life float to which it belongs and buoyant. MI found that the oars for two life floats were not lashed to their respective life floats. 46 CFR 180.175(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI pictures of oars lashed to their respective life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 January 2026 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. MI found that the vessel name on the oars for the life floats were too faded to be legible. 46 CFR 185.604(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 8 January 2026
Resolution: Operator sent MI a picture of the faded oars relabeled.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2026 Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange. MI found that 3 of the 4 lifefloats were sun faded and no longer vivid reddish orange. Repaint lifefloats to the satisfaction of the MI. 46 CFR 160.010-4(n)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 18 February 2026
Resolution: Operator provided MI with pictures of the lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 January 2026 Resolved
Each ring life buoy on a vessel must... If on a vessel on an oceans or coastwise route, be orange in color. MI found that the life ring was sun faded and no longer orange. Repaint life ring orange to the satisfaction of the MI. 46 CFR 180.70(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 12 January 2026
Resolution: MI observed that life ring has been repainted
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2026 Resolved
Each buoyant apparatus must have Type II retroreflective material... on each side and end. MI found that most of the retroreflective tape on the lifefloats was worn and faded. 46 CFR 160-010-4(p)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 18 February 2026
Resolution: Operator provided MI with pictures of lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 January 2026 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. MI found that all 5 floating waterlight batteries on board were expired. 46 CFR 176.808(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2026
Resolved 18 February 2026
Resolution: Operator provided MI with pictures of the new waterlight batteries.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2026 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. MI found fuel oil in several spots on the starboard side of the fuel tank compartment. Pressure test the starboard fuel oil tank at next drydock to the satisfaction of the MI. 46 CFR 176.25-50(a) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2026
Resolution: Operator filled fuel tank with fuel. No excess accumulation of fuel found in bilge or compartment.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 5 January 2026 Resolved
Scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. MI found severe cracking in the FRP above the seating located on the forecastle in front of the pilot house. Seal cracking at next drydock to the satisfaction of MI. 46 CFR 177.01-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2026
Resolution: Operator provided photos of correction. See "FRP Cracking – Star of Monterey Annual Inspection 05JAN26" in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI found a life jacket no longer fit for service. 46 CFR 176.808(b)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 5 January 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: External inspection of fuel tanks and inspection of tank vents, piping, and pipe fittings. Port fuel tank vent line in fuel void appears crushed by sideshell screw. Remove screw in part or whole to make vent line available for MI inspection. 46 CFR 176.804
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed screw removed. No damage to adjacent piping was found.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. Upper starboard 15 person life float found with broken grab line loops and a portion of the main body seem that was failing. Repair or replace life float. 46 CFR 176.808
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Lifefloat onboard was inspected and in servicable condition.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Bait tank piping in lazarette overhead is weeping around fiberglass to pipe connection and around overhead/deck connection. Provide repair details and affect proper repairs. 46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed repair to pipe penetration. No water intrusion observed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2025 Resolved
On a vessel of at 26 feet, a visual and audible alarm must be provided at the operating station. MI observed fuel tank void bilge alarm not visually indicating at operating station. 46 CFR 182.530(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed bilge alarm visual indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length provided that the pump is permanently mounted. MI observed submersible bilge pump in engine room was not mounted to the bilge. 46 CFR 182.520(e ) (3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 March 2025
Resolution: Witnessed submersible bilge pump mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 February 2025 Resolved
Each vessel must have on board an EPIRB, installed to automatically float free and activate. MI observed HRU on EPIRB to be missing expiration date. Operator provided evidence of purchase/installation date and marked HRU with corresponding date. 46 CFR 180.64
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 February 2025
Resolution: Operator provided evidence of purchase date and marked HRU in MI presence.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 February 2024 Resolved
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part: (1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Owner has not completed the worklist for credit drydock. Vessel has expired drydock and may not carry passengers until completing drydock worklist.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Drydock inspection complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of fixed gas fire extinguishing system. During operational test of engine room pre-engineered fire fighting system, engines were able to restart without activating override function.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2024
Resolved 28 March 2024
Resolution: Verified operation of system.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 February 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Underway portion and man overboard drill were not able to be completed due to firefighting discrepancy. Perform satisfactory man overboard drill and underway operational tests in the presence of a marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 February 2024
Resolved 3 April 2024
Resolution: Extended to coincide with MI attendance. 03APR2024: Conducted man overboard drill and underway operation tests.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 February 2024 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew training was not performed within the last 3 months.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 24 March 2024
Resolution: Verified updated training.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 February 2024 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Servicing report for system was not available for inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 15 February 2024
Resolution: Report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Port engine exhaust piping had a water leak on the underside where the non metallic sleeve is clamped to the fiberglass.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 3 April 2024
Resolution: Visually inspected machinery space while underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2024 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeter (24 inches) in diameter. Ring buoy is worn, faded and needs replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 26 February 2024
Resolution: Accepted photo of replaced life buoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 13 February 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Expired items in first aid kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 24 March 2024
Resolution: Verified updated first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There are unterminated wires under the helm console on starboard side.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 February 2024
Resolved 13 February 2024
Resolution: Wire correctly terminated during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 January 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts. Vessel representative completed temporary repair of inoperable collision bulkhead bilge pump. Complete permanent splice, connection to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified proper connection for bilge pump wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 January 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Collision bulkhead bilge space high water alarm was inoperable and corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 January 2023
Resolved 17 January 2023
Resolution: Witnessed sat operation of bilge alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 17 January 2023 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Port light in STBD Head is missing fasteners to provide proper weather-tight closure. Provide means to properly close to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified proper closures for portholes.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 January 2023 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Vessel missing STBD fuel tank vent flame screen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified stbd flame screen.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 January 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Buckets provided on vessel were too large. Procure fire buckets of proper size.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Verified properly sized buckets onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. (b) The records shall be sufficient to: (1) Satisfy the requirements of §§ 16.210(b) and 16.220(c) of this part. (2) Identify the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required by this part including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Provide records of chemical tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 26 January 2023
Resolution: Completed company DAPI audit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Risk evaluation, training and instruction to seafarers
Issued 17 January 2023 Resolved
For a vessel described by 46 CFR175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include all items referenced in this part. Provide required training and log into vessels training/drills logs. Federal Register/V.86 No. 245 46 CFR 185.420 Federal Register/V.86 No. 245 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 1 February 2023
Resolution: Captain provided sat training log.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 February 2022 Resolved
Each hatch exposed to the weather must be watertight. Forward and aft watertight hatches leaked when exposed to water. 46 CFR 171.124(a) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 February 2022
Resolution: New gasket placed on hatches to perform more sufficent seal.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 March 2021 Resolved
The construction and arrangement of a vessel must allow for the safe operation of hte vessel in accordance with the terms of the COI giving consideration to provisions of a seaworthy hull. Vessel's main deck has two soft spots located in the vicinity of the lazarette hatch as well as by the starboard breezeway aft of the main house. The deck in these areas is not adequately supported. Submit a repair proposal with provisions to strengthen the deck in these two areas.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2021
Resolved 12 March 2021
Resolution: Vessel provided repair photos and submitted a statement to effectiveness of repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 February 2020 Resolved
Penetrations and openings in watertight bulkheads must have a means to keep them watertight. Several of the watertight bulkheads required for subdivision have wire and wire runs that are installed without a means to keep the bulkheads watertight. Vessel passenger count reduced to 49 or less until subdivision is met. Provide plan for approval to make bulkheads required for subdivision watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 March 2020
Resolution: The numerous penetrations through the watertight bulkheads were professionally sealed using a fire-rated sealant. The penetration were sealed to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2019 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One adult life jacket was found not serviceable. Vessel limited to 70 adult passengers until life jacket is replaced. 46 CFR 180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2019
Resolution: Vessel added 1 adult life jacket.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 April 2019 Resolved
An exposed hazard, such as rotating machinery must be properly protected by a cover, guard, or rail. Port and Starboard Main Diesel Engine's rotating shafting is not protected. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Shaft guards were provided over both port and starboard shafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019 Resolved
All machinery shall be installed and maintained to afford adequate protection against machinery failure. Fuel return line located on port fuel tank is cracking. 46 CFR 182.07-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Fuel return line replaced with SAE 1942 hose.
Engineering › Bilge Water Management System › Not Operational
Issued 13 February 2017 Resolved
Prove proper operation of lazarette bilge suction. 46 CFR "OLD T" 182.25-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2017
Resolved 14 February 2017
Resolution: Bilge suction satisfactorily tested in Lazarette and forepeak.
Stability › Watertight Integrity › Coaming
Issued 13 February 2017 Resolved
Permanently remove 1" by 4" drainage hole from below aft deck house door. Vessel is on an Oceans route and required to have a 6" watertight coaming under a weather tight door.46 CFR "Old S" 171.124(d)
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 9 March 2017
Resolution: Repaired 1"x4" hole in coaming.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.