Records from 1993 to 2000. Most recent: inspection, 15 June 2000.
Inspection history · 79
15 June 2000
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1050508
18 May 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1049704
26 April 2000
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1048705
13 April 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 176943
6 March 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 815601
7 February 2000
Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1046097
6 February 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 8640
21 January 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1048032
17 December 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 812129
21 November 1999
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1402995
1 November 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 800404
6 October 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 143204
28 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 106223
28 September 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1343932
15 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 148878
4 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 31746
5 April 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1121443
11 March 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 808966
15 February 1999
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1386431
5 November 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 804446
11 October 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1465424
10 September 1998
Deficiency Check · Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 800234
25 August 1998
Administrative
Administrative · Activities Europe · Activity 1132084
23 August 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 163976
29 April 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1124359
11 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1111284
11 February 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1386185
10 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 153198
10 February 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 775428
3 February 1998
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1108195
3 February 1998
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1108419
14 January 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1107960
17 December 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119435
21 November 1997
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1398796
26 September 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1116027
2 September 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119866
1 September 1997
Deficiency Check · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 785117
13 February 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1388216
6 February 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 39879
16 January 1997
Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1449991
10 January 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 54039
9 January 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 700374
30 December 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1095963
22 November 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1457402
6 November 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 858076
29 October 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 90119
3 October 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 835350
16 August 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1084792
11 June 1996
Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1451079
15 April 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1079814
31 March 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2587
30 January 1996
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 882936
6 January 1996
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1355612
29 December 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 113089
17 November 1995
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1374439
7 July 1995
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 883250
15 June 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1189143
23 May 1995
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 872279
20 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 61131
6 April 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 841383
11 March 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1177662
9 March 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 861806
8 March 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 96217
8 March 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1169460
10 February 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1150812
14 January 1995
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1456234
20 December 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 845397
28 September 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1174700
21 September 1994
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1175138
1 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177338
18 July 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1377231
21 June 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1026630
28 May 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1171008
2 May 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 858724
6 April 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1166816
1 April 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 178322
9 February 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1163895
14 January 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 852036
16 December 1993
Initial Certification · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161809
Engineering
Issued 17 December 1999
Resolved
PROVE PROPER OPERATION OF #3 MAIN PROPULSION ENGINE UNDER FULL LOAD BY PROVIDING OPERATING LOGS AND DATA OF ENGINE PERFOMANCE WHILE UNDERWAY.
Condition: Unknown
Due 17 December 1999
Resolved 17 December 1999
Engineering
Issued 21 November 1999
Resolved
PROVE PROPER OPERATION OF HIGH JACKET WATER TEMPERATURE ALARM ON THE AUXILIARY GENERATOR.
Condition: Unknown
Due 17 December 1999
Resolved 17 December 1999
Engineering
Issued 21 November 1999
Resolved
PROVE PROPER OPERATION OF THE HIGH JACKET WATER TEMP, LOSS OF LUBE OIL PRESSURE AND OVERSPEED ALARMS AND SHUTDOWNS ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 17 December 1999
Resolved 17 December 1999
Electrical
Issued 28 September 1999
Resolved
PROVE PROPER OPERATION OF #3 DIESEL PROPULSION GENERATOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 15 February 1999
Resolved
MAKE PERMANENT REPAIR TO #7B STARBOARD TANK IN WAY OF WASTED METAL ON AFT BULKHEAD TO SATISFACTION OF CG INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
MAKE PROPER INSTALLATION REPAIR EMERGENCY GENERATOR FUEL TANK SIGHTGLASS TOSATISFACTION OF THE ATTENDING CG INSPECTION.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
MAKE PROPER REPAIRS TO INSTALLATION OF ENGINEROOM FUEL TANKS SIGHTGLASS TO SATISFACTION OF THE ATTENDING CG INSPECTION.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
PROVE PROPER REPAIR OR RENEW ALL FUEL PUMPS ON BOTH #1 AND #3 MAIN DIESEL GENERATORS TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
INSTALL EXHAUST LAGGING ON #1 AND #3 MAIN GENERATOR TO THE SATISFACTION OF CG MARINE INSPECTOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Engineering
Issued 15 February 1999
Resolved
PROVE PROPER REPAIR TO BOTH #1 AND #3 MAIN DIESEL GENERATORS' REAR OIL LEAKIN WAY OF ENGINE FLYWHEEL, TO SATISFACTION OF CG MARINE INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
PROVE PROPER REPAIR OF F/O PURIFIER FUEL PUMP TO SATISFACTION OF CG MARINE INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
RENEW FUEL SUPPLY PIPE FROM FUEL TANK TO EMERGENCY GENERATOR TO SATISFACTION OF ATTENDING CG INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 15 February 1999
Resolved
PROVE PROPER OPERATION AND REPAIR OF EMERGENCY GENERATOR TO SATISFACTION OFCG MARINE INSPECTOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Electrical
Issued 15 February 1999
Resolved
REMOVE ALL DEAD END ELECTRICAL WIRES IN VARIOUS SPACES TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 15 February 1999
Resolved
CONDUCT OPERATIONAL TEST OF AUX GENERATOR TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR UPON COMPLETION OF INSTALLATION.
Condition: Unknown
Due 15 February 1999
Resolved 15 February 1999
Documentation
Issued 15 February 1999
Resolved
OBTAIN APPROVAL FROM COAST GUARD FOR THE CONVERSION OF #13 P/S BALLAST TANKS TO POTABLE WATER TANKS PRIOR TO USING THESE TANKS FOR POTABLE WATER
Condition: Unknown
Due 15 February 1999
Resolved 15 February 1999
Lifesaving
Issued 15 February 1999
Resolved
PROVE PROPER OPERATION OF RESCUE BOAT TO SATISFACTION OF CG MARINE INSPECTOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Lifesaving
Issued 15 February 1999
Resolved
CONDUCT WEIGHT TEST OF RESCUE BOAT DAVIT TO SATISFACTION OF CG MARINE INSPECTOR PRIOR GETTING UNDERWAY.
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Electrical
Issued 25 August 1998
Resolved
Repair and satisfactorily demonstrate a proper operation of the emergency generator prime mover to the attending Coast Guard Inspector prior to departing from Norfolk, Virginia.
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Electrical
Issued 11 February 1998
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY DIESEL GENERATOR AND CONNECTIONS TO AUXILLARY GENERATORS PRIOR TO DEPARTING THE PORT OF HAMPTON ROADS.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Electrical
Issued 11 February 1998
Resolved
Prior to sailing provide a revised "Generator Transfer Procedure" and proveoperation to the attending marine inspector.
Condition: Unknown
Due 11 March 1998
Resolved 12 February 1998
Documentation
Issued 11 February 1998
Resolved
Provide a copy of the vessel's Coast Guard approved electrical line diagram.
Condition: Unknown
Due 11 March 1998
Resolved 12 February 1998
Electrical
Issued 14 January 1998
Resolved
ISOLATE AND REPAIR GROUNDED CIRCUIT ON EMERGENCY GENERATOR BOARD.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 21 November 1997
Resolved
PROVIDE PLACARD FOR RED FLASHING LIGHT ENGINE ROOM (GQ).
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Electrical
Issued 21 November 1997
Resolved
PROVIDE A DIFFERENT COLORED LENS FOR ENG ALARM WARNING LIGHT LOCATED AFT OF#2 GEN.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Electrical
Issued 21 November 1997
Resolved
DEMONSTRATE PROPER OPERATION OF REVERSE POWER RELAY FOR MDE GENERATOR.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Engineering
Issued 21 November 1997
Resolved
REPAIR CRIMPED COPPER TUBING AIR SUPPLY LINE TO #4 DBL BOTTOM FUEL TANK AIRACCUATED VALVE. CRIMP LOCATED BY VALVE.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 21 November 1997
Resolved
SUBMIT UPDATED STABILITY INFO CALCULATED FOR THE REMOVAL OF #2 MDE GEN SET TO G-MSC.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Engineering
Issued 21 November 1997
Resolved
DEMONSTRATE PROPER OPERATION OF THE OWS.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Electrical
Issued 21 November 1997
Resolved
DEMONSTRATE PROPER OPERATION OF #1 MDE GEN LOW L/O PRESSURE SWITCH SHUTDOWN.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Engineering
Issued 21 November 1997
Resolved
MARK REACH ROD FOR EMERGENCY FUEL OIL CUTOFF TO EMERGENCY GENERATOR.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Engineering
Issued 21 November 1997
Resolved
REMOVE PORTABLE BLOWERS DIRECTED AT #1 AND #3 MDE GOVERNORS, PROVIDE FIXED VENTELATION.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Fire Fighting
Issued 21 November 1997
Resolved
PROVIDE CO2 RELEASE WARNING PLACARD FOR ALARM IN ENG ROOM.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 2 September 1997
Resolved
Prior to additional modifications and final hook-up of bridge remote control system, have all propulsion and steering modifications approved by USCG Marine Safety Center. Demonstrate proper documentation and system operation to cognizant [name withheld] plan modifications NLT 02 OCT 97.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Engineering
Issued 1 September 1997
Resolved
DEMONSTRATE PROPER OPERATION OF PROPULSION AHEAD AND ASTERN CONTROLS TO THESATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Construction/Loadline
Issued 16 January 1997
Resolved
CROP AND RENEW DISTORTED UNDERDECK DEEP WEB FRAMES IN WAY OF #11 PORT VOID.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
CROP AND RENEW BUCKLED SIDE SHELL LONGINTUDINALS #1 AND #2 IN WAY OF #11 PORT VOID.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
REMOVE CONCRETE PATCH IN WAY OF SMOKE STACK AND MAKE AREA AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
REMOVE AND REPLACE WITH APPROVED MATERIAL ALL PACKING IN WAY OF STUFFING TUBES_x001C_ AND BULKHEAD PENETRATIONS IN THE MCC ROOM.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 16 January 1997
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 17 February 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
MAKE PERMANENT REPAIRS IWO #10 STBD BALLAST TANK AND REMOVE SOFT PATCH.
Condition: Unknown
Due 17 February 1997
Resolved 22 January 1997
Accommodation/Occupational Safety
Issued 16 January 1997
Resolved
PROVIDE CG APPROVED PILOT LADDER.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
MAKE REPAIRS TO DAMAGED BULWARK IWO PORT AMD STARBOARD BOW.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Engineering
Issued 16 January 1997
Resolved
MAKE PERMANENT REPAIRS IWO HOLED #8 DIESEL TANK.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
CROP AND RENEW 3 INCH SIDE SHELL SET IN WITH DOUBLER PLATES FROM 5 FEET FORWARD OF SWASH BULKHEAD EXTENDING 23 FEET AFT BY 5 1/2 FEET IN WAY OF #12PORT BALLAST TANK, #11 PORT VOID AND PORT BOUYANCY BOX.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
CROP AND RENEW DISTORTED BULKEAD IN WAY OF #12 PORT BALLAST TANK.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
CROP AND RENEW BUCKLED SIDE SHELL LONGINTUDINAL #5 IN WAY OF OF PORT BUOYANCY_x001C_ BOX.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 16 January 1997
Resolved
RENEW CO2 PULL BOXES OR WATERTIGHT CONTAINER DOORS IWO STBD CO2 CONTROL STATION.
Condition: Unknown
Due 16 January 1997
Resolved 22 January 1997
Accommodation/Occupational Safety
Issued 16 January 1997
Resolved
RENEW MICROSWITCHES IWO OF STBD SIDE FIXED CO2 CONTROL STATION AND DEMONSTRATE PROPER OPERATION OF ADVANCE CO2 DISCHARGE ALARMS.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Accommodation/Occupational Safety
Issued 16 January 1997
Resolved
DEMONSTRATE PROPERER OPERATION OF TOILET IWO OF MAIN DECK (PORT SIDE/AFT).
Condition: Unknown
Due 16 January 1997
Resolved 22 January 1997
Documentation
Issued 16 January 1997
Resolved
COFR EXPIRED ON 16DEC96.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Accommodation/Occupational Safety
Issued 16 January 1997
Resolved
REPLACE VENT REGISTERS IN VARIOUS ACCOMADATION SPACES.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Accommodation/Occupational Safety
Issued 16 January 1997
Resolved
PROVIDE COMPLETED OIL RECORD BOOK FROM 8JUNE96 TO 8JAN97; INCLUSIVE.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Documentation
Issued 16 January 1997
Resolved
PROVIDE VALID CARGO SAFETY CONSTRUCTION CERTIFICATE WITH CURRENT ENDORSEMENT.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
PROPERLY SEAL THE BULKHEAD PENETRATION MADE BY THE CABLES WHICH PENETRATE_x001C_THE BULKHEAD IN THE ENGINE CONTROL ROOM ON THE PORTSIDE.
Condition: Unknown
Due 17 February 1997
Resolved 29 January 1997
Electrical
Issued 16 January 1997
Resolved
REPLACE MISSING GUARDS FOR INCANDESCENT LIGHTS IN THE ENGINE ROOM.
Condition: Unknown
Due 17 February 1997
Resolved 23 January 1997
Electrical
Issued 16 January 1997
Resolved
REPAIR ALL WIRES WHICH ARE PULLED LOOSE FROM THE CONNECTORS FOR THE AIR CONDITIONER/HEATER UNIT IN THE HOUSE.
Condition: Unknown
Due 17 February 1997
Resolved 23 January 1997
Accommodation/Occupational Safety
Issued 16 January 1997
Resolved
PROVIDE A RELIEF VALVE FOR THE FOLLOWING AIR RECEIVERS - WHISTLE AIR TANK LOCATED IN THE STOREROOM AND POTABLE WATER TANK IN THE MOTOR ROOM.
Condition: Unknown
Due 17 February 1997
Resolved 23 January 1997
Electrical
Issued 16 January 1997
Resolved
PROVIDE GROUND DETECTION SYSTEM FOR THE SECONDARY SIDE OF THE TRANSFORMER PROVIDING POWER TO THE WASHING MACHINE IN WAY OF LAUNDRY ROOM AS PER 46_x001C_ CFR 111.05 (d).
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Electrical
Issued 16 January 1997
Resolved
MAKE REPAIRS TO OIL LEAKS IN WAY OF THE AUXILLARY GENERATOR.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Engineering
Issued 16 January 1997
Resolved
TIGHTEN/REPACK EXCESSIVELY LEAKING PORT AND STARBOARD SHAFT SEALS.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Navigation
Issued 16 January 1997
Resolved
PROVE PROPER ALIGNMENT OF RUDDER ANGLE INDICATOR AND ELIMINATE 2-5 DEGREE VARIATION.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 16 January 1997
Resolved
DEMONSTRATE PROPER OPERATION OF FIRE DETECTION SYSTEM.
Condition: Unknown
Due 17 February 1997
Resolved 22 January 1997
Engineering
Issued 16 January 1997
Resolved
PROVIDE PROPER FLAME SCREEN FOR HYDRAULIC TANK VENTS IWO STEERING FLAT.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
AT NEXT DRYDOCK MAKE PERMANENT REPAIRS IN WAY OF #10 STBD BALLAST TANK WITH3 INCH CRACK TO THE 3RD UNDER DECK LONGITUDINAL FROM CENTER.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 16 January 1997
Resolved
REPLACE MISSING A-60 INSULATION IN WAY OF TRANSFORMER ROOM, MCC ROOM, AND CO2 STORAGE ROOM.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 16 January 1997
Resolved
DEMONSTRATE PROPER OPERATION OF THE ELECTRIC WINCH INSTALLATION FOR THE RESCUE BOAT.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
ELIMINATE GAP BETWEEN FLAME SCREEN AND AND BASE ON SEWAGE TANK VENT.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
REATTACH MIDDLE RUNG TO RAIL AND STANCHION IWO STBD GANGWAY.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
CROP AND RENEW WASTED BOTTOM LONG IWO OF PORT AND STARBOARD MOTOR ROOM, NEAR SHAFT SEALS.
Condition: Unknown
Due 17 January 1997
Resolved 22 January 1997
Construction/Loadline
Issued 16 January 1997
Resolved
AT NEXT DRYDOCK MAKE PERMANET REPAIRS TO PIPING EXTENDING OUT OF EXHAUST IWO SMOKE STACK BY SEALING/BLANKING PIPE WITH STEEL.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Engineering
Issued 6 November 1996
Resolved
DUE TO THE PROPULSION FAILURE WHILE THE VESSEL WAS DEPARTING THE PORT OF HAMPTON ROADS, THE VESSELS OWNER/ OPERATORS ARE TO NOTIFY THIS PORT WHEN THE VESSEL RETURNS SO THAT AN INSPECTOR CAN VISIT THE VESSEL TO TEST AND EXAMINE THE PROPULSION EQUIPMENT.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Engineering
Issued 16 August 1996
Resolved
MAKE PERMANENT REPAIRS TO AND PROVE PROPER OPERATION OF THE #3 PRIME MOVER.
Condition: Unknown
Due 16 August 1996
Resolved 16 August 1996
Electrical
Issued 15 April 1996
Resolved
#1 MAIN DIESEL ELECTRIC GENERATOR EXCITER FAILED.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Engineering
Issued 23 May 1995
Resolved
MAKE PERMINENT REPAIRS TO #2 MAIN ENGINE AND PROVE PROPER OPERATION OF SAMETO AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Construction/Loadline
Issued 9 March 1995
Resolved
MAKE PERMANENT REPAIRS TO FRACTURE ON MAIN DECK, PORT SIDE IN WAY OF FORWARD PRESSURE GUIDES ON #1 CARBO BAY.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Lifesaving
Issued 9 March 1995
Resolved
PROVE PROPER OPERATION OF BRIDGE ELECTRONICS, NAVIGATION LIGHTS, STEERING GEAR AND PROPULSION MACHINERY DAMAGED BY WATER PRIOR TO DEPARTURE FROM THE PORT OF HAMPTON ROADS.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Engineering
Issued 10 February 1995
Resolved
DEMONSTRATE OPERATION OF RELIEF VALVE IN WAY OF OUTBOARD AIR RECEIVER LOCATED ON FLAT ABOVE #1 AND #2 MAIN DIESEL ENGINES. DO NOT ISOLATE RECEIVER UNTIL PROPER RELIEF VALVE OPERATION IS OBTAINED.
Condition: Unknown
Due 10 February 1995
Resolved 10 February 1995
Engineering
Issued 10 February 1995
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR. NO EXTENSIONS WILL BE GRANTED FOR THIS REQUIREMENT.
Condition: Unknown
Due 10 February 1995
Resolved 10 February 1995
Accommodation/Occupational Safety
Issued 14 January 1995
Resolved
REPLACE PLASTIC VENTILATION DUCTING IN LAUNDRY ROOM WITH SHEET METAL DUCT MATERIAL.
Condition: Unknown
Due 14 January 1995
Resolved 14 January 1995
Electrical
Issued 14 January 1995
Resolved
PROPERLY MARK/STENCIL ALL EMERGENCY LIGHTING FIXTURES.
Condition: Unknown
Due 14 January 1995
Resolved 14 January 1995
Engineering
Issued 14 January 1995
Resolved
PROVE PROPER OPERATION OF RELIEF VALVES FOR EACH AIR RECEIVER. DEMONSTRATE THE ABILITY TO ISOLATE EACH RECEIVER.
Condition: Unknown
Due 14 January 1995
Resolved 14 January 1995
Engineering
Issued 14 January 1995
Resolved
PROVE PROPER OPERATION OF #1 DIESEL-ELECTRIC ENGINE, INCLUDING LOSS OF LUBEOIL PRESSURE ALARM AND TRIP. TEST OVERSPEED TRIP.
Condition: Unknown
Due 14 January 1995
Resolved 14 January 1995
Engineering
Issued 14 January 1995
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 14 January 1995
Resolved 14 January 1995
Accommodation/Occupational Safety
Issued 14 January 1995
Resolved
MAKE PERMANENT REPAIRS TO ALL DAMAGED HANDRAILS
Condition: Unknown
Due 14 January 1995
Resolved 14 January 1995
Electrical
Issued 18 July 1994
Resolved
PROVE SATISFACTORY OPERATIONAL TEST OF NO. 1 MDG. THIS IS TO BE COMPLETED TO THE SATISFACTION OF THE MARINE INSPECTOR NO LATER THAN 18SEP94.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Engineering
Issued 18 July 1994
Resolved
PROVE SATISFACTORY OPERATIONAL TEST OF OILY WATER SEPARATOR.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Accommodation/Occupational Safety
Issued 18 July 1994
Resolved
PROVE SATISFACTORY OPERATIONAL TEST OF MARINE SANITATION DEVICE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Documentation
Issued 28 May 1994
Resolved
SUBMIT PLANS SHOWING MODIFICATIONS TO 3 DECK SCUTTLES, DRAIN MODIFICATIONS AND SEALING UP OF ONE DOOR LEADING TO THE ROPE LOCKER. THESE DRAWINGS ARE TO BE SUBMITTED TO ABS AND USCG MARINE SAFETY CENTER.
Condition: Unknown
Due 28 May 1994
Resolved 28 May 1994
Engineering
Issued 28 May 1994
Resolved
PROVE PROPER OPERATION OF #3 MAIN ENGINE.
Condition: Unknown
Due 28 May 1994
Resolved 28 May 1994
Documentation
Issued 2 May 1994
Resolved
PRIOR TO DEPARTING THE PORT OF HAMPTON RDS, PROVIDE ORIGINAL CERTIFICATE OFINSPECTION, ON BOARD THE VSL.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Electrical
Issued 2 May 1994
Resolved
PRIOR TO DEPARTING THE PORT OF HAMPTON RDS, PROVE PROPER OPERATION OF MAIN DIESEL ENGINES RELAY TO THE WHEELHOUSE.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Construction/Loadline
Issued 6 April 1994
Resolved
RENEW ALL WASTED DOGS ON THE DOOR TO THE CO2 ROOM LOCATED ON THE STBD. SIDEMAIN DECK AFT OF THE HOUSE.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
PROVE PROPER OPERATION OF THE AUTO START AND ON THE LINE OF THE EMERGENCY GENERATOR.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Construction/Loadline
Issued 6 April 1994
Resolved
NDT, "V" OUT, DRILL STOP, BACK GOUGE AND WELD THE FOUR FOOT CRACK IN THE MAIN DECK STBD. SIDE AFT OF THE HOUSE NEAR FRAME 45. REPAIR TO BE AIR TESTED UPON COMPLETION.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Lifesaving
Issued 6 April 1994
Resolved
CLEAN ALL OIL AND TRASH FROM WITHIN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Electrical
Issued 6 April 1994
Resolved
REPAIR THE EMERGENCY LIGHT LOCATED IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Electrical
Issued 6 April 1994
Resolved
CLEAR ALL ELECTRICAL GROUNDS WHICH ARE SHOWING ON THE EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Engineering
Issued 6 April 1994
Resolved
PROVE PROPER OPERATION OF AT LEAST TWO OF THE THREE MAIN POPULSION ENGINES/GENERATORS.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 6 April 1994
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP AND REMOTE START SWITCH.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Electrical
Issued 6 April 1994
Resolved
PROVE PROPER OPERATION OF THE HOTEL SERVICE GENERATOR LOCATED IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Lifesaving
Issued 6 April 1994
Resolved
MAKE REPAIRS AND PROVE PROPER OPERATION OF THE DAVIT WINCH MOTOR FOR THE RESCUE BOAT.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Construction/Loadline
Issued 6 April 1994
Resolved
REPLACE ALL MISSING BOLTS FOR THE HATCH COVER LOCATED ON THE MAIN DECK AFT OF THE HOUSE NEAR THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Electrical
Issued 6 April 1994
Resolved
REMOVE THE NUMEROUS EXTENSION LIGHTS FROM THE ENGINE CONTROL ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
REPLACE ALL MISSING GLOBES AND GUARDS ON LIGHTING FIXTURES THROUGHOUT THE VESSEL. REPLACE ALL BURNED OUT BULBS.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
REPLACE MISSING MULTICABLE FIRE BOUNDRY SEAL WHERE ELECTRICAL CABLES PASS THROUGH THE VENT DUCT LOCATED IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Engineering
Issued 6 April 1994
Resolved
PROPERLY LABEL THE EMERGENCY FUEL SHUT OFF FOR THE EMERGENCY GENERATOR FUELTANK.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 6 April 1994
Resolved
RELOCATE THE PORTABLE CO2 FIRE EXTINGUISHER IN THE EMERGENCY GENERATOR ROOMTO A LOCATION NEAR THE EXIT.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 6 April 1994
Resolved
REMOVE ALL UNUSED PORTABLE FIRE EXTINGUISHER BRACKETS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
REMOVE OR PROPERLY SECURE AND COVER ALL DEAD ENDED CABLES IN THE ENGINE ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 6 April 1994
Resolved
PROPERLY LABEL WITH THE VESSELS NAME, THE FIRE AXE LOCATED ON THE MAIN DECKAFT OF THE HOUSE.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Accommodation/Occupational Safety
Issued 6 April 1994
Resolved
REPLACE ALL FAN GUARDS FOR THE AIR CONDITIONING UNIT LOCATED ON THE TOP OF THE WHEELHOUSE.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 6 April 1994
Resolved
REPAIR THE LEAKS IN THE CASING OF THE EMERGENCY FIRE PUMP LOCATED IN THE BOW THRUSTER ROOM, AND PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Construction/Loadline
Issued 6 April 1994
Resolved
NDT, "V" OUT DRILL STOP AND WELD THE THE TWO CRACKS IN THE MAIN DECK LOCATED BETWEEN FRAMES 47-48 PORT AND STBD. SIDES OUT BOARD FWD. CORNERS OFTHE CARGO HOLD AREA. CRACKS EXTEND APROX. 2" ON THE MAIN AND 3" INTO THE CARGO HOLD.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Engineering
Issued 6 April 1994
Resolved
PROVE SATISFACTORY OPERATION OF THE #3 MAIN ENGINE / GENERATOR.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
REPAIR ALL ELECTRICL WIRING WHICH IS IMPROPERLY SECURED TO LIGHTING FIXTURES AND JUNCTION BOXES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Construction/Loadline
Issued 6 April 1994
Resolved
REPAIR OR REPLACE WASTED WEATHER DECK DOORS AND REPAIR GASKETS IN SAME IN THE FOLLOWING LOCATIONS: PORT AND STBD. DOORS LEADING TO THE BOW AREA, AND THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
REMOVE THE ELECTRICAL CABLE WHICH IS IMPROPERLY RUN INTO THE DECK LIGHTING PANEL LOCATED ON THE AFTER BULKHEAD ON THE BRIDGE.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 6 April 1994
Resolved
REMOVE TAPE AND INSTALL PROPER COVERS OVER AREAS WHICH ARE MISSING CIRCUIT BREAKERS IN THE LIGHTING PANEL LOCATED ON THE AFTER BULKHEAD ON THE BRIDGE.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Construction/Loadline
Issued 6 April 1994
Resolved
REMOVE RED HAND PATCH FROM THE AFTER HOUSE BULKHEAD PORT SIDE NEAR VENT APROX. 7 FT. UP FROM THE DECK.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 16 December 1993
Resolved
CONDUCT DIRECT CURRENT GROUND FAULT TEST WITH MAIN SHAFT MOTOR ON LINE. RESULTS TO BE ENTERED IN [name withheld]._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Electrical
Issued 16 December 1993
Resolved
RENEW GALLEY RANGE AND CONTROL PANEL WITH UL APPROVED EQUIP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Navigation
Issued 16 December 1993
Resolved
RENEW NAV LIGHT JUNCTION BOX'S AND WIRE CONNECTORS WITH UL MARINE APPROVED EQUIP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
RENEW ALL BRASS FIXTURES IN AFT STEERING WITH UL 595.
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
ALL ELECTRICAL JUNCTION BOXES IN MOTOR ROOM MUST MEET UL 50 OR UL 514._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
PROVE OLD PLASTIC JUNCTION BOX STBD SIDE FWD DECK LEVEL IWO #8 F/O TANK MEET UL 50 OF UL 514._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
RENEW CONTROL PANEL FWD IWO SPECIAL TOOL RACK FOR MDE IN E/R, PANEL IS NOT UL APPROVED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
PROVE ALL LIGHTS AND JUNCTION BOXES IN NEW CRANE TRUNK MEET UL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
PROVE NEWLY INSTALLED UL BOXES IN E/R AND MAIN SWITCHBOARD ROOM MEET UL 50 OR UL 514._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
RENEW NUMEROUS GLOBES AND GUARDS ON LIGHT FIXTURES THROUGHOUT THE VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Engineering
Issued 16 December 1993
Resolved
REMOVE BRASS PETCOCKS FOR LEVEL INDICATOR ON P/S L/O TANKS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 16 December 1993
Resolved
PROVE EMERGENCY FIRE PUMP CONTROL PANEL MEET UL STANDARDS 508.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
RENEW CERAMIC PLUG FUSES WITH APPROVED TYPE IN AUX GENERATOR ROOM, 600V F/OTRANSFER PUMP STBD E/R, FWD FIRE PUMP IN SCR ROOM FWD BULKHEAD BY STAIRS, AND IN THE AIR HANDLERS (HVAC UNITS) IN SCR ROOM PORT SIDE, MAIN DECK FWD STBD, 01 DECK FWD AND ON 02 CHART ROOM STBD._x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Documentation
Issued 16 December 1993
Resolved
SUBMIT THE FOLLOWING PLANS TO MSC (WASH) AND MIO NEW YORK: _x001C_ (1) LINES (2) HATCH COVER (3) CONTAINER PLAN & FOUNTAINS _x001C_ (4) FLOOR PLATING IN CARGO HOLD (5) FRAME 46/47 (6) WING OF A BRIDGE FRAME 43-34 (7) MOORING ARRANGEMENT (FUEL OIL CATCH TANKS)
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Navigation
Issued 16 December 1993
Resolved
CALIBRATE AND SWING SHIP'S MAG. COMPASS AND SUPPLY DEVIATION TABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Accommodation/Occupational Safety
Issued 16 December 1993
Resolved
PERMANENTLY REPAIR RED HAND ON MSD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
RENEW WASHER AND DRYER WITH UL APPROVED EQUIP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
PROVE NAV LIGHT'S CONNECTION PLUGS MEET UL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Engineering
Issued 16 December 1993
Resolved
RENEW ISOLATION VALVE FOR P/V'S IN EXHAUST STACK AND REDO SAFETY VALVE TESTTO VERIFY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
RENEW OVERSPEED TRIP ON AUX. GENERATOR AND RUN A COMPLETE SET OF TESTS. NO TESTS ON AUX. GEN. PREVIOUSLY DONE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
THE FOLLOWING ELECT PANEL'S NEWLY INSTALLED IN E/R MUST MEET U/L MARINE STANDARD'S. 1) FUSE PANEL, DOMESTIC SERVICE PUMPS 2) F/W SANITARY PUMP 3) ELECTRIC HOT WATER HEATER CONTROL 4) L/O TNK AND SLUDGE TANK OIL INDICATOR CONTROL PANEL._x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
PROVE THE FOLLOWING ELECTRICAL PANEL'S NEWLY INSTALLED IN SCR MEETS UL MARINE STANDARDS. 1) BILGE ALARM PANEL 2) A/C UNIT CONTROLLERS P/S_x001C_ 3) D/C GROUND FAULT INDICATOR FOR S.C.R. PANELS._x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Fire Fighting
Issued 16 December 1993
Resolved
HYDRO ALL FIXED CO2 BOTTLES AT AN APPROVED U.S. DOT FACILITY UPON ARRIVAL AT FIRST U.S. PORT.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 December 1993
Resolved
PROVE NEWLY INSTALLED DIC GROUND FAULT INDICATOR FOR MAIN DIC SYSTEM IN SCRRM MEETS UL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Documentation
Issued 16 December 1993
Resolved
IN CONJUNCTION WITH REQUIREMENT #20 MAKE THE VESSEL AVAILABLE FOR INSPECTION BY USCG MARINE INSPECTOR FROM MSO HAMPTON ROADS FOR THE PURPOSE OF RE-EVALUATING ENGINEROOM MANNING REQUIREMENTS.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Documentation
Issued 16 December 1993
Resolved
SUBMIT VENTILATION PROP AND CARGO ROOM CO2 SYSTEM PLANS TO MSC (WASH) AND MIO NEW YORK.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Documentation
Issued 16 December 1993
Resolved
SUBMIT THE FOLLOWING PLANS TO MSC (WASH) AND MIO NEW YORK:_x001C_ (1) CRANE BOOM REST (2) RESCUE BOAT ARRANGEMENT (3) NAVIGATION LIGHTS AFT (4) ACCESS TO AFT ENGINEROOM (5) TANK VOLUME GAUGE FOR TK NO. 6 P+S_x001C_ (6) BILGE BALLAST FIRE FIGHTING (7) FUEL OIL TRANSFER AND SERVICE SYSTEM_x001C_
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Deck/Cargo
Issued 16 December 1993
Resolved
RENEW ANCHOR CHAINS WITH CORRECT SIZE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Documentation
Issued 16 December 1993
Resolved
PROVIDE USCG HAMPTON ROAD'S VA WITH ALL DOCUMENTS NECESSARY TO RE-EVALUATE ENGINE ROOM MANNING IN PARTICULAR WHETHER THE VSL REQUIRES (3) OILERS. USE NVIC 6-84 AND 1-69 AS GUIDANCE.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993