MAURY USCG vessel records Sign in
← All vessels

GALEOMMA

GALEOMMA is a 1978 tank ship. The Coast Guard has recorded 19 inspections since 1987, most recently in April 2006, along with 11 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 1987 to 2006. Most recent: operational control imposed, 6 April 2006.

Built
1978
Last inspected
6 April 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7391202 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-49917

Inspections, by type

…with no type recorded11
Years with a record 8 calendar years (1987–2006)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it54928 - Regulatory (Subpart C or D), Net Ton
69472 - Regulatory (Subpart C or D), Gross Ton
98770 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

6 April 2006 ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2618225
14 February 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2589801
1 February 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2578108
3 January 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2559606
29 November 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2543102
29 November 2005 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2543916
28 November 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2541664
4 January 2005 COC-GAS Renew · ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2268427
27 February 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2015083
26 February 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2013417
24 July 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1856595
24 July 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1856618
8 July 2003 Certificate of Compliance
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1839387
16 September 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 437359
27 July 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 280299
27 July 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1052701
9 December 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1143618
17 September 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452975
15 September 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006188

Deficiency record · 11

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 26 February 2004 Resolved
DIGITAL INDICATORS ON MAIN CONTROL PANEL NOT INDICATING VALVES CLOSINGS. CLASS TO ATTEST TO PROPER REPAIR AND OPERATION OF DIGITAL INDICATORS PRIOR TO RETURN TO A U.S. PORT OR TERRITORY LEGACY COMPONENT DESC: INDICATORS
Action required: 15 - Rectify deficiencies by next port
Due 6 March 2004
Resolved 1 January 2005
Resolution: Outstanding deficiency from MSO BALTIMORE cleared.
Electrical › Electrical Distribution System (emergency)
Issued 8 July 2003 Resolved
Install all gas compresser alarm panel relays. LEGACY COMPONENT DESC: Overcurrent Device
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 8 August 2003
Resolved 24 July 2003
Resolution: Gas compressor alarm panels tested satisfactory.
Electrical › Electric Generation Source (service)
Issued 8 July 2003 Resolved
Replace covers on gas compressor junction boxes. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 16 July 2003
Resolved 24 July 2003
Resolution: All junction boxes found with covers in place.
Deck/Cargo › Cargo Stowage
Issued 8 July 2003 Resolved
Prove proper operation of Gassurveyor Calibration Machine LEGACY COMPONENT DESC: GMI421R Gasurveyor Calibration Machine
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 18 July 2003
Resolved 24 July 2003
Resolution: Gassurveyor calibration machine is bieng removed from vessel. All portable gas detection equipment calibrated with span gas and tested satisfactory.
Construction/Loadline › Penetrations
Issued 8 July 2003 Resolved
Drain standing water from starboard passageway.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 10 July 2003
Resolved 24 July 2003
Resolution: No standing water found in starboard passageway.
Engineering › Steam System (auxiliary)
Issued 8 July 2003 Resolved
Repair steam leak in starboard passageway. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 16 July 2003
Resolved 24 July 2003
Resolution: Steam leak in starboard passageway has been repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003 Resolved
Provide di-electric mats for generator toom switchboard.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 8 August 2003
Resolved 24 July 2003
Resolution: Di-electric mats found in place for generator room switchboard.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003 Resolved
Provide emergency generator with protective covers for: starter connections, agastst relay and junction box. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 16 July 2003
Resolved 24 July 2003
Resolution: Protective covers found in place on equipment.
Electrical › Electrical Distribution System (service)
Issued 8 July 2003 Resolved
Install cover on electric recepatacle in motor room LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 10 July 2003
Resolved 24 July 2003
Resolution: Cover found in place on electrical receptacle.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 July 2003 Resolved
Ensure all stenciling of cargo piping/valves in legible, durable, and permanent. LEGACY COMPONENT DESC: Communications
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 8 August 2003
Resolved 24 July 2003
Resolution: Cargo piping and valves found labeled.
Electrical › Electric Generation Source (service)
Issued 8 July 2003 Resolved
Replace cover on switch box near engine room boiler ignition room. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 July 2003
Resolved 24 July 2003
Resolution: Cover found on switchbox near engineroom boiler ignition room.

Ownership record