MAURY USCG vessel records Sign in
← All vessels

BIG ORANGE 25

BIG ORANGE 25 is a 1978 offshore supply vessel. The Coast Guard has recorded 25 inspections since 1980, most recently in May 1992, along with 21 deficiencies.

Records from 1980 to 1992. Most recent: inspection, 18 May 1992.

Built
1978
Last inspected
18 May 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7726328 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
VANUATU
—
Maury page id
psix-49941

Inspections, by type

…with no type recorded4
Years with a record 8 calendar years (1980–1992)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Net Ton
143 - Regulatory (Subpart C or D), Gross Ton
1313 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

18 May 1992 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1255140
5 November 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250870
3 October 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1257047
24 July 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1250720
19 March 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922702
4 December 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911675
31 July 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920995
19 March 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 926537
13 December 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226687
4 December 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901090
8 November 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225013
6 October 1989 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203452
17 November 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205571
25 July 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1339863
11 July 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897988
4 July 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1040305
7 October 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1322849
15 September 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1015216
10 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327668
31 December 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1309987
5 November 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1023007
14 August 1986 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1007002
18 July 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303118
6 November 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972148
6 November 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274671

Deficiency record · 21

Electrical
Issued 6 October 1989 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF THE EMERGENCY LIGHTING SYSTEM AS REQUIRED IN 46CFR112.15-1(C) IN THE FOLLOWING LOCATIONS: MCC ROOM, PUMP ROOM AND THE LIQUID ADDITIVE ROOM.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Documentation
Issued 6 October 1989 Resolved
PROVIDE ON BOARD VESSEL A VALID COAST GUARD APPROVED STABILITY BOOKLET AS PER REFERENCE IN VESSELS STABILITY LETTER DATED 03 OCT 89 ISSUED BY G-MSC-1
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Documentation
Issued 6 October 1989 Resolved
PROVIDE AND DISPLAY ON BOARD VESSEL AS REQUIRED IN 46CFR91.55 AN APPROVED FIRE CONTROL SAFETY PLAN.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Documentation
Issued 6 October 1989 Resolved
PROVIDE ON BOARD A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY TO REPLACEPROVISIONAL CFR DUE TO EXPIRE 06NOV89 AS REQUIRED BY 33CFR130.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Documentation
Issued 6 October 1989 Resolved
PROVIDE ON BOARD VESSEL A CURRENT DOCUMENTATION CERTIFICATE REFLECTING NEW ADMEASUREMENT VALUES(360.92 GT & 245.0 NT) AS ISSUED BY ABS AND VERIFIED BY G-MVI ON 06 OCT 89.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Documentation
Issued 6 October 1989 Resolved
PROVIDE ON BOARD AS PER 46CFR91.60-20/25 A VALID CARGO SHIP SAFETY RADIOTELEPHONEY CERTIFICATE OR OBTAIN AN EXEMPTION CERTIFICATE VIA COMMANDANT, U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 6 October 1989 Resolved
CONDUCT OPERATIONAL TESTS OF THE DYNAMIC POSITIONING SYSTEM IN ALL MODES OFOPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTION.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 11 July 1988 Resolved
REPAIR AND PROVE OPERATION FOR REACHROD FOR FOREPEAK BILGE INTAKE.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Engineering
Issued 11 July 1988 Resolved
REMOVE RUST AND SLUDGE FROM BOTTOM OF AIR RECEIVER.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Engineering
Issued 11 July 1988 Resolved
RENEW HI OIL SENSOR FOR #2 MAIN ENGINE.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Engineering
Issued 11 July 1988 Resolved
REMOVE WOOD BLOCK SUPPORTS TO AIR FILTERS TO ALL MAIN ENGINES.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Engineering
Issued 11 July 1988 Resolved
WELD UP CRACK IN CONTAINMENT TO MOORING BIT.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Deck/Cargo
Issued 11 July 1988 Resolved
REPAIR PORT ANCHOR WINCH STRIPPING BAR.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Engineering
Issued 11 July 1988 Resolved
RENEW HI TEMP SENSOR ON #3 ENGINE.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Engineering
Issued 11 July 1988 Resolved
LABEL EMERGENCY FUEL SHUT-DOWNS.
Condition: Unknown
Due 11 July 1988
Resolved 11 July 1988
Electrical
Issued 5 November 1986 Resolved
ADDRESS 46 CFR 111.105-31(F)(1), (2), (3), AND (4), AS PER LTR FROM [name withheld], MSO LA/LB.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Fire Fighting
Issued 5 November 1986 Resolved
PROVIDE (3) STEEL-CORED LIFELINES WITH HARNESS.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Fire Fighting
Issued 5 November 1986 Resolved
PROVIDE (3) EXPLOSIONPROOF SAFETY LAMPS OR UL APPROVED OXYGEN AND EXPLOSIVE METERS.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Fire Fighting
Issued 5 November 1986 Resolved
STENCIL ON SIDES OF DECKHOUSE: "NO SMOKING, NO OPEN LIGHTS."
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Documentation
Issued 14 August 1986 Resolved
HAVE VESSEL RE-ADMEASURED AND PROVIDE ON BOARD THE NEW DOCUMENT WITH CORRECT GROSS TONNAGE AND NET TONNAGE AS A RESULT OF RE-ADMEASUREMENT. REQUIRED MANNING MAY CHANGE DUE TO RE-ADMEASUREMENT.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Lifesaving
Issued 18 July 1986 Resolved
UPON PROPER NAME CHANGE OF VESSEL, STENCIL ALL LIFESAVING AND FIREFIGHTING EQUIPMENT WITH VESSEL'S NAME.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.