Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)40.1 ft × 12.0 ft × 4.9 ft
Registered tonnagegross 17 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAFCO, INC · LAFAYETTE LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBATON ROUGE, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton 11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 10 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
2 October 2025Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8245565
19 November 2024Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8029151
20 November 2023Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7820763
29 November 2022Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7601431
22 June 2021COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7232714
29 July 2020Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7013392
20 September 2019Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6816876
3 October 2018Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6554313
14 September 2017Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6264182
13 June 2016Internal Structural Exam · COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903423
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 November 2023Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length and shall be properly supported by non-combustible hangers or blocks. Marine Inspector identified an exhaust leak from the flexible exhaust bellows on the port main propulsion engine. Operator replaced the broken part and conducted a satisfactory test of the port engine to the satisfaction of the Marine Inspector.
46 CFR 182.20-20
46 CFR 182.15-20(a)
10 c
Action required: 10 - Deficiency Rectified
Due 20 November 2023
Resolved 20 November 2023
Resolution: Operator replaced the broken part and conducted a satisfactory test of the port engine to the satisfaction of the Marine Inspector.
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Inspection completed outside 3 months of the due date.
46CFR176.500
Action required: 705 - Other - as specified
Resolved 30 January 2023
Resolution: Letter Of Warning issued and signed by Violating Party.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 July 2020Resolved
MI observed 14 of 27 adult life jackets not serviceable. Replace to the satisfaction of attending USCG marine inspector prior to carriage of passengers.
701C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2020
Resolution: Received documentation attesting to new lifejackets being placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2019Resolved
Exhaust piping shall be gas-tight through its entire length. Found exhaust leak on flex section of STBD MDE exhaust. Repair to satisfaction of attending USCG MI. (OLD T) 46 CFR 182.15-20(a).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2019
Resolved 26 September 2019
Resolution: Exhaust flex section was replaced with hard piping elbow and tested satisfactorily in the presence of a USCG MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 September 2019Resolved
The master of the vessel must ensure that all of the provisions of the COI are strictly adhered to. Found holing and wasted deck above engine room, in way of port handrail mounting. Remove wasted metal and renew to satisfaction of attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2019
Resolved 26 September 2019
Resolution: Affected area was cropped out and rewelded. USCG MI's carried out visual inspection of repair and water lance test.
Found hatch rubber gasket on fore peak excessively brittle and hardened. Replaced rubber gasket to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2018
Resolved 4 October 2018
Engineering › Bilge Water Management System › Not Operational
Issued 27 June 2016Resolved
Bilge alarm in Main Cabin void space not operational.
Condition: Improper/Lack of Maintenance
Due 4 July 2016
Resolved 27 June 2016
Resolution: Broken wire found and replaced. System functions as designed, all sat.
Rudder post has vent line leading overboard through the side shell plating with no valve installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 July 2016
Resolved 27 June 2016
Resolution: Installed valve, tested all sat.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.