13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that
all observed unsafe practices and hazardous situations be corrected. Vessel pilothouse shutdown for starboard engine was unable to shutdown starboard engine. Make repairs and demonstrate to attending marine inspector the pilothouse shutdown for starboard engine is able to shutdown starboard engine.
46 CFR 176.25-50(a)
Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2023
Resolution: Attended vessel and witnessed the stbd engine shutdown from the pilothouse; all sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 October 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Vessel starboard engine did not shut down during simulated CO2 activation via pressure switch. Make repairs and demonstrate to the attending marine inspector that both engines shut down during simulated CO2 activation.
46 CFR 181.410(b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2023
Resolution: Attended vessel and witnessed the starboard engine shut down by simulating CO2 activation via pressure switch; all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 October 2023
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High water level alarm for aft compartment is not giving a visual alarm. Demonstrate to attending marine inspector visual and audible alarm for high bilge level in all required spaces.
46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2023
Resolution: Attended vessel and witnessed the high water level alarm for the aft compartment audio and visual alarm; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 October 2022
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. In the midship compartment under port side of fuel tank pitting at 5/64 inch. Provide hull thickness to verify wastage. Wastage beyond 25% requires repair proposal to be approved and complete prior to next credit drydock.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 17 October 2022
Resolution: Hull thickness verified as 3/8". Wastage not beyond 25%.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Amidship on both port and starboard sides, small individual holes approximately 1/16" in diameter are present on the deck. Effective temporary repairs in place now, make permanent prior to next credit drydock.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 16 October 2023
Resolution: Attending MI inspected the amidships area; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 January 2022
Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except on passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: (i) Bulwarks;(ii) Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or
(iii) Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches)
The vessel has bulwarks that decrease in height from the bow to the stern, thus increasing the distance between the top of the bulwarks and the required top rail. The decrease in height of the bulwark creates an opening that exceeds 4 inches on the port and starboard quarters and the stern of the vessel.
Install courses to decrease the opening between the top rail and bulwarks to no more than 4 inches. If courses cannot be immediately installed submit a mitigation plan to be reviewed and approved by the attending USCG Marine Inspector until courses are installed. 46CFR177.900(g)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 22 April 2022
Resolution: Courses of stainless steel cable provided as required.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 November 2020
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Master and crew were not aware of testing or maintenance requirements for the heat detector. Create and adhere to a maintenance plan based on manufacturer's instructions.
46CFR176.810(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2020
Resolution: Witnessed HAD test performed by Oahu Fire Protection.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 5 November 2020
Resolved
Where a flexible vent pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Port fuel tank vent hose is rubbing on vertical support frames. Clean up and install chaffing gear.
46CFR182.450(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: Installed chaffing gear.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 November 2020
Resolved
Fuel tanks must be adequately supported and braced to prevent movement. The supports and braces must be insulated from contact with the tank surfaces with a nonabrasive and nonabsorbent material. Metal band securing fuel tank is causing chaffing in areas discussed with operator. Clean up and install nonabsorbent chaffing gear.
46CFR182.440(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: Installed chaffing gear.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2020
Resolved
A fixed gas fire extinguishing system may protect more than one space. The quantity of extinguishing agent must be at least sufficient for the space requiring the greatest quantity as determined by the requirements of this section. Air gaps exist where cables penetrate the bulkhead between the engine compartment and fuel tank compartment. Eradicate air gaps in bulkhead.
46CFR181.410(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2020
Resolution: Filled gaps to eradicate the passage of air between spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 November 2020
Resolved
Gauges to indicate engine revolutions per minute, jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The oil pressure gauge for the starboard engine is inoperable. Repair gauge.
46CFR184.402(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 January 2021
Resolution: Installed new oil pressure gauge
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 November 2020
Resolved
Except on a vessel limited to daylight operations, the compass must be illuminated. Master and crew were unaware of how to illuminate the compass. Provide proof of or install illuminated compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 January 2021
Resolution: Amending COI to "vessel is restricted to daylight operations only" at owner's request in lieu of completing this item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Install back cover for switchboard at operating station and cover opening on front of switchboard as discussed.
46CFR183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2020
Resolution: Installed plastic cover
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2020
Resolved
The vessel owner or operator must pay the annual vessel inspection fee each year on or before the vessel's user fee anniversary date, unless the fee has been prepaid under 2.10-105 of this subpart.
46CFR2.10-101(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2020
Resolution: User fees paid.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2019
Resolved
A vessel shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Vessel was unable to demonstrate proper operation of its primary steering system. Repair and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: Vessel bled air in hydraulic hose line and successfully proved proper operation of primary steering system.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 October 2019
Resolved
A qualified servicing facility shall conduct inspections and tests of a fixed gas fire extinguishing system. Vessel's fixed gas system had been serviced and tagged but did not have the fire servicing certificate on board. Provide fire servicing certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 October 2019
Resolution: Vessel provided fire servicing certificate for fixed and portable sytems.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 October 2019
Resolved
Vessel should be compliant with the standards acceptable to the cognizant OCMI as good marine practice. Vessel's steel anchor is stored in direct contact with the aluminum hull and causing initial corrosion. Provide a protective material between the anchor and the hull to prevent future corrosion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 October 2019
Resolution: Vessel installed rubber matting in anchor hold to prevent contact of the steel anchor with the aluminum hull plate.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 October 2019
Resolved
An exposed hazard such as gears or rotating machinery, must be properly protected bya cover, guard, or rail. One of the vessel's machinery guards is attached with plastic zip-ties. Provide proper metal supports for the engine's machinery guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 October 2019
Resolution: Vessel installed machinery guard with proper metal supports.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 October 2018
Resolved
Connections must be made to battery terminals with permanent type connectors. Connections are made with wing nuts. Remove wing nuts and install hex nuts with lock washers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 11 November 2018
Resolution: Removed wing nuts and installed hex nuts with lock washers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2018
Resolved
Employers must ensure that they and their crew members meet the requirements of part 16. Provide proof of enrollment of all crew members in random chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 11 November 2018
Resolution: Provided proof of enrollment of all crewmembers in company's random chemical testing program.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 October 2018
Resolved
On a vessel of at least 26 feet in length, a visual and audible indicator must be provided at the operating station indicate high water level in each normally unmanned space with a through-hull fitting, machinery space, shaft alley, space with non-watertight closure and other spaces subject to flooding. Vessel has one visual indicator for all required spaces. Install and demonstrate operation of audible and visual indicators for each space required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 11 November 2018
Resolution: Installed separate indicators for bilge high water alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2018
Resolved
Each battery used in lifesaving equipment must be replaced during the annual inspection if the expiration of the battery has passed or the battery is without an expiration date. Replace the battery in the life-ring floating light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 11 November 2018
Resolution: Replaced battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 October 2018
Resolved
Nonmetallic flexible hose from starboard engine to keel cooler showing signs of wear. Renew hose with approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 11 November 2018
Resolution: Renewed hose.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2017
Resolved
Remove or terminate all dead end electrical wiring throughout vesel.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 21 November 2017
Resolution: Removed as required.
Construction/Loadline › Hull › Side Shell
Issued 30 October 2017
Resolved
Provide repair proposal for hole and pitting in anchor storage area on starboard side. Complete repair following USCG approval of proposal.
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 13 December 2017
Resolution: Repair completed
Construction/Loadline › Hull › Bottom Plating
Issued 30 October 2017
Resolved
Provide repair proposal for pitting/wastage along keep, notably found in midsection storage. Crop and renew once proposal is USCG accepted.
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 13 December 2017
Resolution: Repair complete
Construction/Loadline › Hull › Bottom Plating
Issued 30 October 2017
Resolved
Make available for inspection keel plating underneath fuel tank.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 10 November 2017
Resolution: Provided borescope and UT gauging report for this area which found plating in good condition.
Construction/Loadline › Hull › Side Shell
Issued 15 November 2016
Resolved
1/4" diameter hole found inside of the anchor storage locker. The hole penetrates the hull on the starboard side, 3 feet above the waterline and 2 feet aft of the bow. Additional pitting corrosion found within 5 inche radius of the hole inside of the compartment. Submit repair proposal to OCMI for review by the next credit dry-dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 13 December 2017
Resolution: Plating was cropped and renewed.
Construction/Loadline › Penetrations › Gasket
Issued 15 November 2016
Resolved
Replace and reseat the watertight hatch gasket for the void space located forward of the main cabin. (number 1 void space)
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 February 2017
Resolution: Gasket renewed and hatch reseated correctly.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 15 November 2016
Resolved
Make proper connections to the grounding wire on the fuel tank portside fuel fill hose. Replace corroded grounding connections on the fuel fill grounding conductors.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 16 November 2016
Resolution: Grounding conductor renewed.
Engineering › Fuel Oil Service System › Hose
Issued 15 November 2016
Resolved
Replace corroded fuel hose connections penetrating the number 2 void space and engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 16 November 2016
Resolution: Connections cleaned and placed back into service.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 15 November 2016
Resolved
Replace blocked flame screen for the fuel tank located on the portside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 16 November 2016
Resolution: Repaired to the sat of MI.
Lifesaving › Lifebuoys › Serviceable
Issued 15 November 2016
Resolved
Replace deteriorated grab line and life line on the ring buoy. Apply retro reflective tape to the ring buoy or replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2016
Resolved 17 November 2016
Resolution: Operator replaced 24" life ring buoy in kind with new.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 November 2016
Resolved
Replace broken glass for the CO2 engine room fire extinguishing system remote activation located at the operating station.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 February 2017
Resolution: Broken glass replaced in kind.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 November 2016
Resolved
Replace inoperable starboard running light.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 February 2017
Resolution: Verified starboard running light operable.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 November 2016
Resolved
Passenger count reduced to 18 adults based on the amount of lifejackets onboard in a servicable condition.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 February 2017
Resolution: New lifejackets onboard to reflect total amount of passengers authorized on COI.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 November 2016
Resolved
Adult lifejackets are required to be stowed separate from children's lifejackets. Separate adult lifejackets from children's lifejackets and label the children's stowage area with minimum 2 inch lettering for total number and "children's lifejackets."
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 February 2017
Resolution: Child lifejackets are stowed in same copartment but separated from adult. Child lifejackets are stored in a bag labeled, child lifejackets only.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 15 November 2016
Resolved
Clean paint off of grounding conductors attached to the main engine. Conductors at the connection should be metal to metal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 16 November 2016
Resolution: Connections cleaned to sat of MI.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 November 2016
Resolved
Provide adequate support for the exhaust cooling line on the starboard main engine. The flexible hose connected to the main engine attaches to a steel elbow that is not supported.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2016
Resolved 9 February 2017
Resolution: Verified adequate supports for exhaust cooling line installed.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 15 November 2016
Resolved
Clean corroded terminal connections for postive battery conductors located at the battery switch bus bar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016
Resolution: Battery connections were cleaned by the operator and placed back into service.