← All vessels
PELICAN
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named PELICAN
PELICAN is a 1978 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1981, most recently in June 2017, along with 99 deficiencies and 2 operational controls.
Records from 1981 to 2017. Most recent: inspection, 6 June 2017.
- Built
- 1978
- Last inspected
- 6 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 99 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
599716
WDC4306
49974
Flag
UNITED STATES
303342000 (licence lapsed)
Maury page id
psix-49974
Inspections, by type
…with no type recorded11
Years with a record
25 calendar years (1981–2017)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
19 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDC4306MMSI 303342000 · expired · compulsorily equipped · granted 8 March 2005, cancelled 9 May 2015
WCX6932MMSI not assigned · expired · voluntarily equipped · granted 20 August 1997, cancelled 20 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
6 June 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6167210
11 April 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2905821
3 April 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2902145
1 January 2006
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2560208
7 December 2005
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2548000
26 November 2005
Type not recorded
No type recorded · USCGC CUSHING (WPB 1321) · USCG Southeast District (CGD-SE) · Activity 2546718
1 June 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2383464
26 April 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2342971
11 April 2005
Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2332879
10 April 2005
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2331700
22 February 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2304748
18 January 2005
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2282219
13 December 2004
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2266398
6 April 2004
Administrative Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2039025
26 February 2004
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2015447
30 May 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1873855
28 April 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1782227
12 March 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1758211
15 January 2003
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1735883
5 February 2002
Simplified Stability Test
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1489388
18 January 2002
Simplified Stability Test · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1488407
29 August 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1071743
26 June 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 49767
15 June 2001
Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1470321
9 January 2001
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1423496
17 July 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1051448
22 June 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1451570
17 June 1999
Re-Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1457689
13 April 1999
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1375720
16 June 1998
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1390785
5 March 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1118392
24 November 1997
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 776039
22 November 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 737
8 August 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1460109
19 June 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1371872
1 May 1997
Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1439874
6 June 1996
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1448766
14 June 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422584
3 April 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 850233
30 June 1993
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 864205
24 June 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 845102
11 February 1992
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 952906
11 February 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435313
16 December 1991
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1259214
23 April 1990
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909701
22 February 1990
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909664
29 August 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1347012
5 June 1989
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1350024
16 February 1989
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1344042
26 May 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1339529
1 September 1987
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1308379
5 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323867
2 October 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006314
6 March 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994956
6 February 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989610
11 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284642
22 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972912
7 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972277
18 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274507
8 December 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969382
Deficiency record · 99
Construction/Loadline › Hull › Bottom Plating
Issued 1 January 2006
Resolved
STEERING COMPARTMENT AND ENGINE COMPARTMENT ARE FLOODED. VESSEL MUST BE DRY-DOCKED & PROPER REPAIRS CONDUCTED.
Pollution Prevention/Response › Response Equipment › Containers
Issued 1 January 2006
Resolved
ENGINE COMPARTMENT CONTAINS OIL/WATER MIXTURE. THIS MIXTURE MUST BE DISPOSED OF PROPERLY. PROVIDE PROPER RECEIPT OF DISPOSAL OF THIS OIL/WASTE TO RIO PONCE AT [phone withheld].
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 27 December 2005
Resolved
Provide documentation stating that the exhaust (04 mufflers) have been installed satisfactorily and that the vsl equipment is operational. * Exhaust mufflers were removed in the steering compartment due to welding repairs.
Construction/Loadline › Hull › Side Shell
Issued 21 December 2005
Resolved
Make permanent repairs, to the satisfaction of the attending USCG Inspector, to the small (1" wide x 1/2" high) hole in the sideshell, stbd side aft below the waterline.
Construction/Loadline › Hull › Side Shell
Issued 13 December 2005
Resolved
Make permanent repairs to port side hull aft side shell below the waterline with an insert to the satisfaction of attending Marine Inspector. Owner to submit a repair proposal and welder certification prior to commence the repair. ****This is a duplicate entry******
Construction/Loadline › Hull › Side Shell
Issued 7 December 2005
Resolved
Make permanent repairs to the small (approx 1/8") hole below the water line, port side, caused by unknown circumstances, possibly a drill bit.
Construction/Loadline › Hull › Bottom Plating
Issued 11 April 2005
Resolved
Make vessel hull available for inspection by the attending USCG Marine Inspector. Vessel grounded w/ water ingress into steering compartment on 10Apr05.
Engineering › Bilge Water Management System › Pump
Issued 11 April 2005
Resolved
Prove proper operation of the bilge pump in the steering compartment to the attendedin USCG Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 11 April 2005
Resolved
Replace safety pin for the port propeller counter nut.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 11 April 2005
Resolved
Repair portside rudder post fasteners that are loose and/or missing conter nuts.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 11 April 2005
Resolved
Make repairs to portside rudder to eliminate excessive play up and down and sideways. There are approx 3" of play.
Engineering › Bilge Water Management System › Pump
Issued 11 April 2005
Resolved
Make steering room bilge pump to operate automatically. Presently pump is working manually.
Engineering › Bilge Water Management System › Pump
Issued 22 February 2005
Resolved
Install and prove the proper operation of an independent visual indicator alarm for either the bilge pump operating indicator or the bilge high water level indicator. Currently both visual indicator alarms share the same indicator light. Each visual indictor alarm for the bilge high level and bilge pump operating must be labelled accordingly 46CFR 182.530
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 January 2005
Resolved
Provide proof of enrollmet w/ an approved drug consortium.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 January 2005
Resolved
Maintain a training and life saving equipment maintenance log.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2005
Resolved
Prove the proper operation of the anchor light. Vessel is restricted to daytime operations until cleared.
Construction/Loadline › Structures › Superstructure
Issued 18 January 2005
Resolved
Replace three cracked windows with approved safety glass to the satisfaction of the attending USCG Marine Inspector.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 18 January 2005
Resolved
Renew retroreflective tape on the lower buoyant apparatus to the satisfaction of the attending USCG Marine Inspector.
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 18 January 2005
Resolved
Vessel restricted to carrying no more than 30 adult passengers due to lack of sufficient pfds as per the COI.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 18 January 2005
Resolved
Mark portable fire extinguisher location om the aft cabin bulkhead to the satisfaction of the attending USCG Marine Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 18 January 2005
Resolved
Prove the proper operation of the bilge water high level visual alarm. The audible alrms is operational.
Engineering › Bilge Water Management System › Pump
Issued 18 January 2005
Resolved
Prove the proper operation of the visual bilge pump operating indicator.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 18 January 2005
Resolved
Alleviate the safety hazard from the cabin door dog and bolt. This steel is a hazard due to excessive corrosion.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 April 2004
Resolved
Repair cooling water supply pipe for the starboard engine wet exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Engineering › Bilge Water Management System
Issued 26 February 2004
Resolved
Permanently attach the existing reach rod for bilge suction to the valve forward of the collision bulkhead to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Valve
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 February 2004
Resolved
Adjust the forward and aft main deck hatches to make them watertight to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Deck Hatches
Electrical › Electrical Distribution System (service)
Issued 26 February 2004
Resolved
Provide cover to electrical junction box in cabin under pilot station to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Junction Box
Documentation › Certificates/Documents
Issued 26 February 2004
Resolved
Provide a valid FCC Safety Certificate to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: FCC Safety Certificate
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 26 February 2004
Resolved
Sesure the refrigerator to prevent shifting while underway to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Unsecured
Electrical › Lighting (service)
Issued 26 February 2004
Resolved
Provide a cover for engine room light to the satisfaction of the attending USCG Inspector. LEGACY COMPONENT DESC: Cover
Lifesaving
Issued 12 March 2003
Resolved
Provide battery for EPIRB.
Lifesaving
Issued 12 March 2003
Resolved
Provide float-free arrangement for EPIRB.
Lifesaving
Issued 12 March 2003
Resolved
Provide water-light for lifefloat.
Lifesaving › Lifebuoys
Issued 12 March 2003
Resolved
Provide waterlight to life ringbuoy. LEGACY COMPONENT DESC: Self-igniting Lights
Lifesaving › Buoyant Apparatus
Issued 12 March 2003
Resolved
Provide two paddles of 4 feet in length to life-floats.
Lifesaving › Buoyant Apparatus
Issued 12 March 2003
Resolved
Stencil vessel name to life-float paddles.
Engineering › Fuel Oil Service System
Issued 12 March 2003
Resolved
Stencil direction of operation of emergency fuel shut-off valve. LEGACY COMPONENT DESC: Valve
Engineering › Fuel Oil Service System
Issued 12 March 2003
Resolved
Proof proper operation of emergency fuel shut-off valve. LEGACY COMPONENT DESC: Valve
Stability
Issued 18 January 2002
Resolved
Vessel to provide stability letter for exposed waters operation if vessel wants to operate with more than 7 passengers and more than 3 miles from shore. LEGACY COMPONENT DESC: Stability test for Exposed Waters Required
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 January 2002
Resolved
Vessel switchboard must have all switches marked or label to depict type of operation or service.
Engineering
Issued 18 January 2002
Resolved
Vessel crew to demonstrate operation of high water level alarms (visual and audio).
Personnel › Training
Issued 18 January 2002
Resolved
Vessel crew to show proof of First Aid Training by Red Cross. LEGACY COMPONENT DESC: Red Cross First Aid Training
Engineering
Issued 15 June 2001
Resolved
INSTALL APPROVED HOSE ON RAW WATER SYSTEM IN WAY OF RAW WATER PUMP ON PORT ENGINE.
Electrical
Issued 15 June 2001
Resolved
PERMANENTLY FASTEN LOOSE WIRING ON STARBOARD ENGINE ALERNATOR.
Lifesaving
Issued 15 June 2001
Resolved
INSTALL APPROPRIATE SIZE WEAK-LINKS FOR LIFE FLOATS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Engineering
Issued 15 June 2001
Resolved
REPLACE MISSING HOSE CLAMPS ON RAW WATER SYSTEM IN WAY OF STARBOARD ENGINE.
Construction/Loadline
Issued 15 June 2001
Resolved
PROVE PROPER OPERATION OF BILGE PUMP IN LAZARETTE.
Engineering
Issued 15 June 2001
Resolved
INSTALL APPROVED VALVE IN FUEL RETURN LINE IN WAY OF PORT SIDE FUEL FILTER PRIOR TO CARRYING PASSENGERS FOR HIRE.
Electrical
Issued 15 June 2001
Resolved
REPAIR TO ORIGINAL, FUEL PUMP FOR GENERATOR. PROVE PROPER OPERATION TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 22 June 2000
Resolved
PROVIDE AN ADDITIONAL (01) FIRE BUCKET PROPERLY LABELED. 46CFR181.610
Lifesaving
Issued 22 June 2000
Resolved
REPAIR CRACKED WELD ON PORT ENGINE MOUNT INBOARD SIDE.
Construction/Loadline
Issued 22 June 2000
Resolved
REPAIR CRACKED WELD IN FOREPEAK IWO OF FIRST SIDELONG FROM OVERHEAD SECOND FRAME FROM FWD.
Lifesaving
Issued 22 June 2000
Resolved
PROVIDE PROOF OF NOAA REGISTRATION. 46CFR185.728
Engineering
Issued 17 June 1999
Resolved
REPAIR ENGINE CONTROL SYSTEM PRIOR TO THE CARRIAGE OF PASSENGERS.
Lifesaving
Issued 24 November 1997
Resolved
MAKE VESSEL AVAILABLE FOR DAMAGE SURVEY PRIOR TO OPERATING WITH PASSAGERS.
Construction/Loadline
Issued 24 November 1997
Resolved
MAKE PERMANENT REPAIR TO DAMAGE LOCATED STARBOARD SIDE JUST FORWARD OF ENGINE INTAKE FWD DECK AND SHEER STRAKE.
Documentation
Issued 8 August 1997
Resolved
MISSING CERTIFICATE OF DOCUMENTATION
Documentation
Issued 14 June 1995
Resolved
OBTAIN FCC OPERATOR'S LICENSE.
Navigation
Issued 14 June 1995
Resolved
FIX OR REPAIR STERN LIGHT.
Lifesaving
Issued 14 June 1995
Resolved
REPAIR OR REPLACE SNAPS ON 3 ADULT PFD'S.
Lifesaving
Issued 14 June 1995
Resolved
PUT RETROREFLECTIVE MATERIAL ON THE LIFE FLOAT.
Documentation
Issued 14 June 1995
Resolved
OBTAIN FCC STATION LICENSE.
Accommodation/Occupational Safety
Issued 14 June 1995
Resolved
INSTALL MSD HOLDING TANK.
Electrical
Issued 14 June 1995
Resolved
PROVE OPERATION OF THE GENERATOR.
Fire Fighting
Issued 14 June 1995
Resolved
OBTAIN 2 B-II TYPE FIRE EXTINGUISHERS.
Lifesaving
Issued 14 June 1995
Resolved
REPLACE RETROREFLECTIVE MATERIAL ON 8 ADULT AND 3 CHILD PFD'S.
Construction/Loadline
Issued 3 April 1995
Resolved
WELD UP TWO (2) PINHOLES ON THE PORT SIDE BOTTOM, MIDSHIP, OUTBOARD SIDE.
Lifesaving
Issued 11 February 1992
Resolved
LABLE PFD STOWAGE AREAS_x001C_ _x001C_
Construction/Loadline
Issued 11 February 1992
Resolved
CLEAN BILGES AND REMOVE OIL
Lifesaving
Issued 11 February 1992
Resolved
PROVIDE FOUR ADULT PFDS
Engineering
Issued 11 February 1992
Resolved
PROVIDE OPERATIONAL TEST OF MAIN ENGINES AND GENERATORS AFTER INSTALLATION OVERHAUL
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
PROVIDE OPERATIONAL INSTRUCTIONS FOR MARINE SANITATION DEVICES
Navigation
Issued 11 February 1992
Resolved
PROVIDE 1992 TIDE TABLES
Electrical
Issued 11 February 1992
Resolved
ENCLOSE SHOREPOWER TRANSFER SWITCH
Navigation
Issued 11 February 1992
Resolved
PROVIDE CHARTS FOR AREA OF OPERATION
Fire Fighting
Issued 11 February 1992
Resolved
PROVIDE RETAINING DEVICES FOR ALL PORTABLE FIRE EXTINGUISHERS
Lifesaving
Issued 11 February 1992
Resolved
REPAIR OR REMOVE WATERLIGHT FOR STARBOARD RING BUOY
Lifesaving
Issued 22 February 1990
Resolved
PROVIDE TWO ADULT TYPE I PFD'S. UNTIL THIS REQUIREMENT IS COMPLETED, YOUR PASSENGERS ARE REDUCED BY TWO
Navigation
Issued 22 February 1990
Resolved
REMOVE EXCESSIVE SLACK IN STEERING LINKAGE
Engineering
Issued 22 February 1990
Resolved
REPAIR PORT MDE EXHAUST LEAK
Fire Fighting
Issued 22 February 1990
Resolved
HYDROTEST & SERVICE TWO B-II CO2 PORTABLE FIRE EXTINGUISHERS
Lifesaving
Issued 22 February 1990
Resolved
MARK LIFE JACKET STOWAGE
Navigation
Issued 22 February 1990
Resolved
PROVIDE & DEMONSTRATE PROPER NAVIGATION LIGHTS, MASTHEAD, RUNNING & STERN
Navigation
Issued 22 February 1990
Resolved
PROVIDE THREE RED AND THREE ORANGE FLARES
Navigation
Issued 22 February 1990
Resolved
REPLACE PORT RUDDER
Engineering
Issued 22 February 1990
Resolved
REPAIR AND MARK EMERGENCY F/O SHUT-OFF VALVE
Navigation
Issued 16 February 1989
Resolved
RENEW STARBOARD STEERING RAM FLEXIBLE HOSE
Electrical
Issued 16 February 1989
Resolved
PROVIDE PERMANENT CONNECTION FOR POWER SUPPLY TO BATTERY CHARGER TO MAIN POWER PANEL WITH APPROPRIATELY SIZED MARINE TYPE CABLE AND CIRCUIT BREAKER
Engineering
Issued 16 February 1989
Resolved
LABEL REMOTE EMERGENCY FUEL OIL SHUT-OFF VALVE
Electrical
Issued 16 February 1989
Resolved
PROPERLY SUPPORT ELECTRIC CABLES FROM BATTERY CHARGER TO BATTERIES
Navigation
Issued 16 February 1989
Resolved
PROVIDE THREE ADDITIONAL APPROVED HAND HELD FLARES PER 46 CFR 180.35
Engineering
Issued 16 February 1989
Resolved
TEST IN THE PRESENCE OF CG MARINE INSPECTOR BOTH MAIN ENGINES AND PROPUL- SION CONTROL SYSTEMS FORE AND AFT
Navigation
Issued 16 February 1989
Resolved
REMOVE DISABLED AFT STEERING WHEEL ACTUAL COMPLIANCE FOR ALL ABOVE REQUIREMENTS: 18MAR89
Electrical
Issued 16 February 1989
Resolved
RENEW CHARRED BATTERY CABLE FROM BATTERY TO ADJACENT JUNCTION BOX
Construction/Loadline
Issued 6 February 1986
Resolved
BOLT DOWN CENTER WALKWAY BETWEEN ENGINE HATCHES. COMPLIANCE DATE IS 06MAR86.
Electrical
Issued 6 February 1986
Resolved
PROVIDE GUARD FOR GENERATOR BELT DRIVE. COMPLIANCE DATE IS 06MAR86.
Construction/Loadline
Issued 6 February 1986
Resolved
PROVIDE CHAINS TO SECURE LAZARETTE AND FOREPEAK HATCHES TO VESSEL. COMPLIANCE DATE IS 06MAR86.
Engineering
Issued 6 February 1986
Resolved
PROVIDE RIGID SUPPORT FOR RAW WATER COOLING LINE ON PORT ENGINE. COMPLIANCE DATE IS 06MAR86.
Electrical
Issued 6 February 1986
Resolved
MAKE PERMANEND REPAIRS TO GENERATOR EXHAUST MUFFLER. COMPLIANCE DATE IS 06MAR86.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.