← All vessels
CORAL ACE
Freight Ship · Bulk Carrier class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named CORAL ACE
CORAL ACE is a 1998 freight ship. The Coast Guard has recorded 20 inspections since 1999, most recently in February 2010, along with 5 deficiencies and 4 operational controls.
Records from 1999 to 2010. Most recent: inspection, 26 February 2010.
- Built
- 1998
- Last inspected
- 26 February 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9176266 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FJQ9
499746
Flag
PANAMA
—
Maury page id
psix-499746
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it25942 - Convention (Subpart B), Gross Ton
16173 - Convention (Subpart B), Net Ton
54318 - Displacement, Ton
47286 - Dead Weight, Ton
16173 - Convention (Subpart B), Net Ton
54318 - Displacement, Ton
47286 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
26 February 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3680142
2 February 2009
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3400247
12 August 2008
NPV Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3296901
7 August 2008
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3305036
30 July 2008
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3284584
25 June 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3248008
21 January 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3129327
18 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3129223
16 September 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2493896
24 February 2005
ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2297953
4 June 2004
MTSA/ISPS Verification · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2088953
9 February 2004
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1999717
21 October 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1932905
12 June 2003
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1816132
26 November 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1711298
17 November 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 295611
26 May 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 290497
5 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282830
18 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275935
30 July 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 431485
Deficiency record · 5
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 August 2008
Resolved
See naratives
Fire Fighting › Emergency Fire Pumps
Issued 9 February 2004
Resolved
Prove proper operation of the emergency fire pump to the satisfaction of Class. Complete prior to departure.
Pollution Prevention/Response › Prevention Equipment
Issued 9 February 2004
Resolved
Prove proper operation of the waste oil incinerator to the satisfaction of Class. The incinerator could not ignite the fuel. A burning rag was needed to begin the burn. The door gasket to the incinerator leaks and the refractory is fractured. SOLAS 74 amd I/11. Complete prior to departure. LEGACY COMPONENT DESC: Incinerator
Pollution Prevention/Response › Prevention Equipment
Issued 9 February 2004
Resolved
Prove proper operation of the oily water separator (OWS) to the satisfaction of Class. An oil like substance was found in the pipe immediately inboard of the OWS overboard sea valve (through hull valve). Prove proper piping of the OWS system where modifications were recently made. MARPOL 73/78 I/16 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Pollution Prevention/Response › Prevention Equipment
Issued 9 February 2004
Resolved
Prove proper operation of the oil content meter to the satisfaction of Class. A disconnected wire was found inside the oil content meter. MARPOL 73/78 I/16. Complete prior to departure. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.