Records from 1999 to 2016. Most recent: inspection, 13 May 2016.
Documentation record
Registered dimensions (L × B × D)221.6 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 627
ITC dimensions (L × B × D)221.6 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 627
BuilderNORTH AMERICAN SHIPBLDG · HOUMA, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2092 - Convention (Subpart B), Gross Ton
627 - Convention (Subpart B), Net Ton
3268 - Dead Weight, Ton
4829 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
13 May 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876283
28 August 2014
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4966823
20 May 2014
Hull Examination · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4862306
11 May 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4862646
29 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3548767
16 July 2009
Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3536703
17 January 2009
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3395833
17 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3402711
14 July 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3267673
24 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3222248
18 July 2007
Re-Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3002325
17 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2751284
8 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2739860
11 July 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2710710
20 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2518908
3 October 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2523887
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501720
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294017
15 October 2004
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2221364
23 July 2004
Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2140773
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979611
3 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1895413
30 August 2002
Underwater Inspection in lieu of Drydock · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670184
23 August 2002
Re-Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664513
27 August 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436617
3 October 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462894
15 May 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 100028
9 September 1999
Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369340
Construction/Loadline › Hull › Hull Plating
Issued 17 January 2009
Resolved
Vessel has 10" x 3/4" puncture/fracture in hull plating IWO 89ft forward of stern and 12ft below the waterline in the #4 fuel tank
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 January 2009
Resolution: Chine plate and bottom plate was replaced and air tested.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 14 July 2008
Resolved
Prove proper operation of remote engineer's assistance needed alarm in Chief's stateroom.
Due 14 August 2008
Resolved 23 July 2008
Communications › Audible Communications › Horn/Whistle
Issued 14 July 2008
Resolved
Prove proper operation of ship's horn.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2008
Electrical › Electric Generation Source (service) › Generator
Issued 14 July 2008
Resolved
Prove proper operation of vsl's port side ship service generator including overspeed trips and reverse power relay.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2008
Construction/Loadline › Structures › Door
Issued 14 July 2008
Resolved
adjust watertight door dogs at aft entrance to the engineroom
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 July 2008
Resolved
Prove proper operation of ship's OWS.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 July 2007
Resolved
Demostrate proper operation of fire detection system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2007
Resolution: Fire detection system repaired by service technician.
Stability › Watertight Integrity › Deadlight Cover
Issued 18 July 2007
Resolved
Demonstrate proper operation of E/R watertight door indicator on bridge.
Due 16 August 2007
Resolved 2 August 2007
Resolution: Watertight door indicator for E/R repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 July 2007
Resolved
Renew Shaft Alley bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2007
Resolution: Renewed shaft alley bilge alarm.
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 18 July 2007
Resolved
Crew not properly trained in use of Safety Lamp. Recommended training, or purchase of new oxygen deficient detection meter.
Due 16 August 2007
Resolved 2 August 2007
Resolution: Vessel Captain verified deficiency correction.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 8 August 2006
Resolved
Provide steering failure alarm system.
Due 8 September 2006
Resolved 29 July 2009
Resolution: Alarm tested sat.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 8 August 2006
Resolved
Update automation test procedures to include steering alarms.
Due 8 September 2006
Resolved 29 July 2009
Resolution: Vessel rep stated that shipyard provided changes to the automation procedures testing.
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 July 2006
Resolved
Service expired liferaft - vsl limited to 25 total persons until corrected.
Condition: Improper/Lack of Maintenance
Due 11 August 2006
Resolved 4 August 2006
Resolution: Master faxed completed worklist item.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 11 July 2006
Resolved
Provide new personnel hanrnesses for man overboard platform (expired service life)
Condition: Unknown
Due 11 August 2006
Resolved 8 August 2006
Resolution: Master faxed completed worklist item.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 11 July 2006
Resolved
Repair hi and low level sensors for emergency generator fuel tank.
Condition: Improper/Lack of Maintenance
Due 11 August 2006
Resolved 8 August 2006
Resolution: Master faxed completed worklist.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 11 July 2006
Resolved
Provide steering failure alarm.
Condition: Improper Installation
Due 11 August 2006
Resolved 29 July 2009
Resolution: Alarm tested sat.
Engineering › Fuel Oil Service System
Issued 3 September 2003
Resolved
Replace all plastic Raycor filter plugs with metallic plugs. LEGACY COMPONENT DESC: Filter
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2003
Resolved 3 September 2003
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 3 September 2003
Resolved
Post fuel oil transfer procedures.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2003
Resolved 3 September 2003