MAURY USCG vessel records
← All vessels

LADY BECKY

LADY BECKY is a 1978 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 42 deficiencies and 1 casualty investigation in 2006.

Records from 2006 to 2026. Most recent: inspection, 28 April 2026.

Built
1978
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5672
Flag
UNITED STATES
Maury page id
psix-49981

Documentation record

Registered dimensions (L × B × D)73.3 ft × 18.1 ft × 8.6 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing porthouston, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 42 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

28 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8350346
3 February 2025 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8073792
3 February 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8073829
16 July 2024 Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7959907
3 May 2024 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7906229
13 September 2023 Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7791063
18 July 2023 Administrative Inspection · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7746146
18 January 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7621205
15 December 2022 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7609771
1 August 2022 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7501103
14 September 2021 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7312390
27 July 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7258146
17 April 2020 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6940594
6 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6827606
20 June 2019 Administrative Inspection · Drydock Exam · In-Service Inspection · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6719871
6 September 2018 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6534183
30 July 2018 DAPI Audit · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6495320
14 September 2017 Hull Examination · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6267439
22 May 2017 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6150011
22 May 2017 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6173555
10 May 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6142938
22 July 2016 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5949444

Deficiency record · 42

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 28 April 2026 Resolved
The intent of this part is to ensure that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Marine inspector observed exhaust lagging on both ship service diesel generators to be oil soaked. {46 CFR 182.01-5}
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 30 April 2026
Resolution: Vessel crew replaced oil soaked exhaust lagging.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 28 April 2026 Resolved
The intent of this part is to ensure that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Marine Inspector observed exhaust lagging on both main engines to be oil soaked. It was also observed that sections of exhaust lagging were damaged, exposing bare piping. {46 CFR 182.01-5}
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 30 April 2026
Resolution: Vessel crew replaced oil soaked exhaust lagging.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2026 Resolved
The rules concerning lights shall be complied with from sunset to sunrise. Observed both mast lights to be very weakly illuminated. Both lenses were also considerably degraded. Vessel is restricted to daylight operations only. {33 CFR 83.20(b)}
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 30 April 2026
Resolution: Mast lights were replaced with new bulbs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 April 2026 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 PSI at the pump outlet. During test of the fire pump, outlet pressure at the gauge was <50PSI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 19 May 2026
Resolution: New fire pump installed. Conducted operational test. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2026 Resolved
Each life float shall be fitted with a water light of an approved automatic electric type, constructed in accordance with Subpart 161.010. STBD life float water light housing was cracked. {46 CFR 180.15-5(d)(i)}
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 19 May 2026
Resolution: Floating water light replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2026 Resolved
The Marine Inspector must check the settings of the safety relief valves on all pressure vessels twice every 5 years. Engine room air receiver relief had no tag/date/servicing paperwork.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 19 May 2026
Resolution: Relief valve replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 28 April 2026 Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck. Mounted emergency lighting below the pilot house was equipped with wire and plug for a wall outlet. Light was also not plugged in.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2026
Resolved 19 May 2026
Resolution: Verified emergency lighting had battery back-up. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 April 2026 Resolved
Each hatch exposed to the weather must be watertight... Each hatch cover must have securing devices. Engine room barn doors had damaged gaskets and no securing devices to make them watertight. {46 CFR 171.124(a)(b)}
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 19 May 2026
Resolution: Securing devices intalled on engine room bay doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2025 Resolved
Junction boxes, connection boxes, and outlet boxes for use in damp locations shall be of watertight construction. Inboard steering hydraulic pump motor connection box is wasted. 46 CFR 183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 April 2025
Resolution: Junction box for hydraulic pump motor connnection box was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary under normal and emergency conditions. Vessel lighting and battery charger in the engine room are plugged into an outlet receptacle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 April 2025
Resolution: Rewired to own breaker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2025 Resolved
Waste receptacles must be construction of non-combustible materials. Trash cans are plastic.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 April 2025
Resolution: Replaced with fire retardant bin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 March 2025 Resolved
The rules concerning lights shall be complied with from sunset to sunrise. STBD navigational light bulb bracket is broken within the housing. The housing needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 April 2025
Resolution: Repaired mounting bracket for the bulb.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2024 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Found lagging missing on the port engine exhaust. Repair to the satisfaction of the Marine Inspector. 46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 24 May 2024
Resolution: Replaced the missing lagging on the port engine exhaust.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found four lighting fixtures in the engine room that did not guard protecting from damage. Repair to the satisfaction of the Marine Inspector. 46 CFR 183.01-15(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 24 May 2024
Resolution: Placed guards on 04 lighting fixtures in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found cabling on both main diesel engines that was not bundled together. Repair to the satisfaction of the Marine Inspector. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 24 May 2024
Resolution: Bundled the cabling on both main diesel engines.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 May 2024 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Found 02 lifejackets missing a whistle,01 missing a light, and 03 missing retro-reflective. 46 CFR 180.75(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 May 2024
Resolution: Vessel replaced 02 lifejackets with a whistle, 01 with a light, and 03 retro reflective.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 May 2024 Resolved
Life floats and buoyant apparatus, together with their oars and paddles, shall be conspicuously marked with the vessel's name. Found 01 paddles that did not have the vessels name marked or painted. 46 CFR 185.30-5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 May 2024
Resolution: Vessel marked vessel name on 01 paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 May 2024 Resolved
All life floats and buoyant apparatus shall be of approved types (160.027).The life floats installed on the vessel had one of two permanently attached name plates as required by 46 CFR 160.010-8 and 46 CFR 160.027-2. 46 CFR 180.10-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 24 May 2024
Resolution: Installed a name plate on 01 lifw floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy did not have a USCG approval number attached to it. Correct to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 1 August 2023
Resolution: Vessel owner replaced the life ring with a USCG approved lifering and labeled it correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2023 Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant OCMI. The design, construction, and original testing of such unfired pressure vessels must meet the applicable requirements of subchapter F (Marine Engineering) of this chapter. Relief valves had no proof of testing. Relief Valve needs to be replaced or tested to satisfaction of inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 1 August 2023
Resolution: Vessel owner replaced all relief valves with no tested and approved valves.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 December 2022 Resolved
Fire Detection - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel has not installed the interconnected detection and alarm systems to meet the new regulations outlined in 181.450. Vessel will install and test to the satisfaction of the attending MI and the vessel will be limited to a route of limited coastwise. 46 CFR 181.405 (c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 January 2023
Resolution: System installed to the satisfcation of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 1 August 2022 Resolved
ALL VESSEL SHALL BE PROVIDED WITH A SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATERTIGHT COMPARTMENT OTHER THAN SMALL BUOYANCY COMPARTMENT. BILGE PUMP UNDER ACCOMMODATION SPACE UNABLE TO PROVE SUCTION. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: Replaced valve. Bilge pump able to prove suctions.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 August 2022 Resolved
PROVISIONS SHALL BE MADE BY MEANS OF PLUGS, COVERS, ETC… TO PREVENT ADMISSION OF AIR INTO SPACE. UNABLE TO SECURE FIRE DAMPER ON STARBOARD SIDE FOR MAIN ENGINE. 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: Fire damper repaired and able to be secured.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 August 2022 Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTIONS. ELECTRICAL CABLE PORT SIDE OF AIR CONDITIONER HAD 0.03 VOLTS LAYING IN BILGE THIRD COMPARTMENT AFT. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 August 2022
Resolution: Vessel placed wire in junction box and out of bilge well.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 August 2022 Resolved
STOWED SO WHEN THE VESSEL SINKS THE SURVIVAL CRAFT FLOATS FREE. STARBOARD SURVIVAL CRAFT UNABLE TO FLOAT FREE. PRIOR TO LOADING PASSENGERS, INSTALL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2022
Resolution: Starboard survival craft now float free.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 August 2022 Resolved
ALL VESSELS MUST HAVE NAVIGATION LIGHTS THAT ARE IN COMPLIANCE WITH THE APPLICABLE SECTIONS OF THE NAVIGATION RULES. AFT LIGHT NOT OPERATIONAL. MUST BE REPAIRED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2022
Resolution: Vessel repaired wire inside stern light. Light operational.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 August 2022 Resolved
WIRING JOINTS (1) WIRING JOINTS AND SPLICES SHALL BE MECHANICALLY SECURED AND MADE JUNCTION BOXES. SPACE UNDER ACCOMMODATIONS ELECTRICAL SUB PUMP WITH SPLICED WIRE CONNECTIONS MADE FAST WITH ELECTRICAL TAPE. REPAIR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 183.05-50(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2022
Resolution: Proper wire connections have been added to wire splice.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 August 2022 Resolved
OPENINGS THROUGH WHICH CONDUCTORS ENTER SHALL BE ADEQUATELY CLOSED. LOW AIR PRESSURE ALARM JUNCTION BOX UNDER BRIDGE CONSOLE MISSING CLOSURE. REPAIR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 183.10-20 (f(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2022
Resolution: Proper closure added to junction box.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 August 2022 Resolved
ALL VESSELS SHALL BE PROVIDED WITH A SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATERTIGHT COMPARTMENT. BILGE SUCTION MANIFOLD NEEDS TO BE LABELED FOR ALL COMPARTMENTS. REPAIR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2022
Resolution: Vessel properly labeled bilge suction manifolds.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 August 2022 Resolved
DISCHARGE PIPE THAT PENETRATES THE HULL BELOW A LINE DRAWN PARALLEL AND AT LEAST 6 INCHES ABOVE DEEPEST SUBDIVISION MUST HAVE MEANS TO PREVENT WATER ENTERING VESSEL IF PIPE FAILS. HANDLE FROM SINK AND SHOWER DISCHARGE MISSING. REPAIR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 171.119(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2022
Resolution: Vessel fitted sink/shower discharge with handle.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 August 2022 Resolved
IF PASSENGERS ARE NOT ASSIGNED OVERNIGHT ACCOMMODATION SPACE, THE MASTER MUST CONDUCT PASSENGER EMERGENCY EGRESS DRILL PRIOR TO BEGINNING AN EXCURSION WITH NEW PASSENGERS. LOG SHIPS EGRESS DRILLS PRIOR TO LOADING PASSENGERS. 46 CFR 185.507(a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 January 2023
Resolution: Vessel's accommodation space is for crew only.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 July 2021 Resolved
A power-driven fire pump shall be installed on each mechanically propelled "L" vessel. Fire pump observed to have steady leak from underside while providing adequate water pressure. Repair so pump runs adequately with no leaks. Old T: 46 CFR 181.10-1(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 August 2021
Resolved 28 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2020 Resolved
Bilge Piping System- The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point. Bilge suction FWD of the eng room was effected by a leaking union. This leak prevented the three FWD spaces from the manifold to reach the required 50GPM IAW 182.25-10 (a). New union installed to the satisfaction of attending Marine Inspector. 46 CFR 182.25-5 (c) Old T
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 May 2020
Resolution: New union added to replace leaking pipe.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 31 July 2018 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of §80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz. The MF-DSC transmitter and receiver must be capable of operation on 2670 kHz. Vessel’s MF-DSC radio was not checked for proper operation and installation under the Radiotelephone Safety Certificate. Vessel is restricted to a 20 nautical mile limitation from land.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 6 September 2018
Resolution: Vessel route has been changed to coastwise removing the MF radio requirement. Refer to activity 6534183.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 31 July 2018 Resolved
L. Vessels there shall be a minimum of two (2) fire hydrants on a mechanically propelled "L" vessel. Due to a hole in the fire main piping the fire main has been isolated down to only one (1) fire hydrant.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2018
Resolved 1 August 2018
Resolution: Hole in fire main piping was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 31 July 2018 Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel only has life float capacity for 27 persons. Vessel is limited to 27 persons.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 2 August 2018
Resolution: Vessel had lifefloats to accommodate 100% of the total persons.
Engineering › Steering Gear System › Rudder
Issued 15 September 2017 Resolved
Vessel representative noted damage to the rudder and made unauthorized repairs without making notification to the Officer in Charge, Marine Inspections. Vessel is to cease all operations and be made available for inspection. All repairs must be made to the satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 18 September 2017
Resolution: See invoice
Engineering › Bilge Water Management System › Valve
Issued 22 May 2017 Resolved
Engine room bilge line doesn't have a check valve. Each line is required to have a stop valve and a check valve or a stop-check valve. Repair to satisfaction of attending marine inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Added check valve to bilge piping.
Engineering › Steering Gear System › Motor
Issued 22 May 2017 Resolved
Junction box on outboard steering pump is corroded. Junction boxes must be watertight. Repair to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 26 May 2017
Resolution: Vessel owner fiberglassed the junction box so the junction box is now watertight.
Construction/Loadline › Structures › Scuttle
Issued 22 May 2017 Resolved
Emergency exits are not labeled. Properly label escape hatches to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 26 May 2017
Resolution: All emergency exits were properly labeled with "Emergency Exit Keep Clear"
Engineering › Fuel Oil Service System › Valve
Issued 22 May 2017 Resolved
Fuel shutoff valves are not labeled. Fuel shutoff valves must be labeled and include direction of closure. Label to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Corrected on the spot.
Engineering › Compressed Air System (start air) › Valve
Issued 22 July 2016 Resolved
Pressure relief valve on air receiver needs to be replaced. Valve doesn't have a servicing tag.
Condition: Improper/Lack of Maintenance
Due 8 August 2016
Resolved 8 August 2016
Resolution: Relief valve has been replaced with serviced unit.

Casualty record · 1

19 February 2006Routine · role: Involved in a Marine Casualty · activity 2647360
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.