A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 18 August 1999
Resolved
PROVIDE A RECORD OF FIREFIGHTING EQUIPMENT TESTS AND INSPECTIONS IN ACCORDANCE WITH 46 CFR 132.350 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Engineering
Issued 18 August 1999
Resolved
PROVIDE ADEQUATE HEAT SHIELDING OF AUXILLIARY GENERATOR EXHAUST PIPING IN ACCORDANCE WITH 46 CFR 58.01-20 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Lifesaving
Issued 18 August 1999
Resolved
INSTALL A CORROSION-RESISTANT TAG TO THE FALL USED WITH THE RESCUE BOAT LAUNCHING APPLIANCE PERMANENTLY MARKED WITH DATA REQUIRED BY 46 CFR 131.550PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Deck/Cargo
Issued 18 August 1999
Resolved
PROVIDE INFORMATION ADDRESSING ADEQUATE ANCHORING SYSTEM INSTALLATION RELATIVE TO THIS VESSEL'S UNIQUE DESIGN CHARACTERISTICS PRIOR TO COMPLIANCEDATE.
Condition: Unknown
Due 18 August 2000
Resolved 18 August 1999
Resolution: This item was cleared by MSO Morgan City by their letter, Ser Num M-90144, Dated 19 May, 1999.
Deck/Cargo
Issued 18 August 1999
No resolution recorded
PROVIDE EVIDENCE OF COMPLIANCE WITH API SPEC. 2C FOR 210 TON CRANE, 0001, AS REQUIRED BY 46 CFR 108.601 PRIOR TO OPERATION BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 18 September 1999 — due date passed with no resolution recorded
Electrical
Issued 18 August 1999
Resolved
PROVIDE NON-CONDUCTIVE GRATING IN WAY OF AREA AT AUXILLIARY GENERATOR PANELBOARD IN ACCORDANCE WITH 46 CFR 129.330 (g) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 18 September 1999
Resolved 30 June 2003
Resolution: Confirmed grating previously installed
Electrical
Issued 18 August 1999
Resolved
REPLACE BLUE LIGHT REPLACEMENT LENS' THAT ARE NOT "AS NEW" WITH PROPER REPLACEMENTS AS REQUIRED BY MANUFACTURER.
Condition: Unknown
Due 18 September 1999
Resolved 30 June 2003
Resolution: Confirmed that the above lenses were installed and appeared to be adequate for the installation.
Documentation
Issued 18 August 1999
Resolved
PROVIDE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.750 PRIOR TO TRANSFERRING OIL PRODUCTS BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Documentation
Issued 18 August 1999
Resolved
PROVIDE A SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) IN ACCORDANCE WITH33 CFR 151.26 THRU .28 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 December 1999
Resolved 19 December 2003
Resolution: Interim SOPEP was approved by CCGD8 (m) pending approval of the submitted plan.
Navigation
Issued 18 August 1999
Resolved
INSTALL LIGHTING REQUIRED FOR POWER-DRIVEN VESSEL UNDERWAY (FWD MASTHEAD LIGHT) IN ACCORDANCE WITH INTERNATIONAL NAVIGATION RULE 23 OF PROVIDE A USCG LETTER OF ALTERNATE COMPLIANCE PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 18 September 1999
Resolved 18 August 2003
Resolution: Certificate of Alternative Compliance (COAC) granted to place the navigation lights as built.
Lifesaving
Issued 18 August 1999
Resolved
PROVIDE EVIDENCE OF VESSEL NUMBERING FOR RESCUE BOAT IN ACCORDANCE WITH 33 CFR SUBPART B PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Deck/Cargo
Issued 18 August 1999
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH API RP 2D FOR 70 TON CRANE, C-150-70D- 593, AS REQUIRED BY 46 CFR 107.260 PRIOR TO OPERATION BUT NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Engineering
Issued 18 August 1999
Resolved
DESIGNATE A PERSON IN CHARGE (PIC) BY NAME OR POSITION AS REQUIRED BY 46 CFR 155.700 PRIOR TO TRANSFERRING FUEL BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Electrical
Issued 18 August 1999
Resolved
PROVIDE ADEQUATE OVERCURRENT PROTECTION FOR CONDUCTION ON SECONDARY SIDE OF150 KVA AND 112.5 KVA TRANSFORMERS ON PLAN ISI-6870-260-E4-1, REV B, VESSELDISTRIBUTION PANELS AS REQUIRED BY "MISCELLANEOUS ELECTRICAL PLANS" MSC _x001C_ LETTER DATED 15 JANUARY 1999, COMMENT 2, PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Navigation
Issued 18 August 1999
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR CHANGE-OVER PROCEDURES FOR REMOTE STEERING GEAR AND STEERING GEAR POWER UNITS IN ACCORDANCE WITH 33 CFR 164.35 (k) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Fire Fighting
Issued 18 August 1999
Resolved
PROVIDE EVIDENCE THAT ALL FIRE HOSES MEET STANDARD 19 OF UNDERWRITERS LIMITED IN ACCORDANCE WITH 46 CFR 132.130 PRIOR TO COMPLIANCE DATE. _x001C_ _x001C_ MANUFACTURER'S SPECIFICATIONS PROVIDED INDICATING MEETING STANDARD.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Documentation
Issued 18 August 1999
Resolved
PROVIDE REQUIRED USCG APPROVED NEW CONSTRUCTION ELECTRICAL LOAD ANALYSIS AND MISCELLANEOUS FOUNDATIONS, ISI6860-A252-FD1-1 THRU -11 PLANS IN ACCORDANCE WITH 46 CFR 127.100 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 December 1999
Resolved 18 August 1999
Resolution: Obtained MSC Approved copies of the above drawing dated on 17 Feb 2003.
Deck/Cargo
Issued 18 August 1999
Resolved
PROVIDE A PUBLIC ADDRESS SYSTEM IN ACCORDANCE WITH 46 CFR 113.50 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Fire Fighting
Issued 18 August 1999
Resolved
REMOVE, SECURE, OR REPLACE WITH A NON-RETURN VALVE THE VALVE AT THE CONNECTION BETWEEN THE FIRE MAIN AND THE BILGE/BALLAST MANIFOLD AS REQUIREDBY 46 CFR 132.120 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Fire Fighting
Issued 18 August 1999
Resolved
DISTINCTLY MARK IN RED LETTERS AT LEAST 2" HIGH "CARBON DIOXIDE FIRE APPARATUS" THE CO2 BOTTLE STORAGE ROOM AS REQUIRED BY 46 CFR 97.37-13 (a) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Navigation
Issued 18 August 1999
Resolved
PROMINENTLY DISPALY MANEUVERING INFORMATION REQUIRED BY 33 CFR 164.35 (g) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Accommodation/Occupational Safety
Issued 18 August 1999
Resolved
PROVIDE SAFETY CHAIN AT ALL TRANSIT OPENINGS OF SAFETY RAILING LEADING TO LADDERS AS REQUIRED BY 46 CFR 127.330 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Accommodation/Occupational Safety
Issued 18 August 1999
Resolved
PROVIDE PRESSURE RELIEF DEVICES ON POTABLE WATER HEAD PRESSURE VESSELS (2) IN ACCORDANCE WITH 46 CFR 54.15-5 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Deck/Cargo
Issued 18 August 1999
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH API RP 2D FOR 70 TON CRANE, C-150-70D- 594, AS REQUIRED BY 46 CFR 107.259 PRIOR TO OPERATION BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Fire Fighting
Issued 18 August 1999
Resolved
PROVIDE A SCHEMATIC DIAGRAM OF THE FIXED CO2 SYSTEM IN ACCORDANCE WITH 46 CFR 95.15-10 (h) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Lifesaving
Issued 18 August 1999
Resolved
PROVIDE THE MANUFACTURER'S INSTRUCTIONS FOR MAINTENANCE OF THE LIFESAVING APPLIANCES ABOARD IN ACCORDANCE WITH 46 CFR 131.545 (a) OR (d) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999