Records from 2016 to 2025. Most recent: inspection, 15 December 2025.
Inspection history · 24
15 December 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8283955
20 March 2025
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8095317
2 December 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8029238
6 September 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7959101
9 January 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7811366
16 March 2023
Plan Review "T" Boat · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7652251
2 February 2023
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7627240
7 November 2022
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7586766
26 September 2022
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7549793
24 February 2022
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7401678
21 January 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7383168
18 November 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7353830
9 February 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7136428
29 January 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7133192
22 October 2020
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7077990
9 January 2020
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6883768
5 February 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6618815
30 January 2019
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6616732
17 January 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6333274
18 September 2017
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6269636
5 May 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6146695
13 March 2017
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6104106
18 January 2017
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6070725
29 December 2016
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6063496
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2024
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Section of bilge pipe servicing the Forepeak compartment found to be broken and repaired with a temporary soft rubber patch. Provide permanent repairs of bilge piping section. 46 CFR 182.25-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 13 December 2024
Resolution: Repaired with metal coupling and conducted test of bilge piping to the satisfaction of the attending MI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 December 2024
Resolved
For each marine casualty required to be reported by 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. All alcohol swabs on board the vessel were found to be expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 13 December 2024
Resolution: Obtained new alcohol swabs and kept on vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 December 2024
Resolved
Watertight doors must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: "WATERTIGHT DOOR - KEEP CLOSED". Watertight doors in engine room did not have any markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 13 December 2024
Resolution: Watertight doors were properly marked.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 December 2024
Resolved
Abandon ship and man overboard drills and training (and firefighting drills and training) shall be logged or otherwise documented for review by the Coast Guard upon request. Drills were not logged and available.
Action required: 10 - Deficiency Rectified
Resolved 2 December 2024
Resolution: Crew satisfactorily performed abandonship, man overboard and fire drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 January 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessel was not able to perform a proper shutdown of ventilation and engines for the fixed suppression system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Vessel satisfactory demonstrated proper shutdown of the engines via the fire extinguishing system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 January 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Inspector noted that one of the vents had an opening from a removed shore tie connection. Vessel was able to bolt aluminum plate to close the opening.
Action required: 10 - Deficiency Rectified
Due 9 January 2024
Resolved 9 January 2024
Resolution: Vessel was able to cover opening with aluminum plate
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 February 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Provide plans for installation of an interconnected fore detection system to Sector LA/LB.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Vessel installed 08 battery operated interconnected fire detectors to meet regulation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2022
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a
vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189
liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. Fire pump psi reading did not exceed 48psi.
46CFR181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 16 March 2023
Resolution: Vessel installed new fire pump that reaches 86 PSI while hose station is open.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 January 2022
Resolved
A hatch exposed to the weather must be weathertight. Aft weathertight door does not shut fully.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2022
Resolved 15 February 2023
Resolution: Vessel repaired door and frame.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 January 2022
Resolved
Guards for exposed hazards must be properly protected by a cover, guard or rail. Head fan squirrel cage open.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2022
Resolution: Operator submitted photo of screen installed over fan opening.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 January 2021
Resolved
Vessel is rwequired to complete a hull exam every 2 years. Vessel is over due for hull exam.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2021
Resolved 9 February 2021
Resolution: Vessel completed hull exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 October 2020
Resolved
Vessel is required to have an operating bilge system.
Vessel's bilge system was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
Resolution: Proved proper operation of bilge system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 October 2020
Resolved
Vessel is required to have water tight bulkheads.
Vessel's aft engine room bulkhead wasn't water tight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
Resolution: Bulkhead was made watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 October 2020
Resolved
Vessel is required to have 03 servicable life ring buoys.
Two of the vessel's life ring buoy's grab lines were wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: Grab lines were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2019
Resolved
Replace both safety valves on air recievers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2019
Resolved 14 March 2019
Resolution: Safety valves replaced.
Documentation › Certificates/Documents › Stability Letter
Issued 13 March 2017
Resolved
As required by MSC letter (Serial H1-1501915), submit new draft mark information to MSC for revision of stability letter.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 25 January 2018
Resolution: Submission complete.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2017
Resolved
Repair anchor light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2017
Resolved 13 February 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 December 2016
Resolved
Repair hydraulic steering leak stbd side lazarette.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 January 2017
Resolved 13 February 2017
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 29 December 2016
Resolved
Replace door on breaker panel in the lazarette.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 January 2017
Resolved 18 January 2017
Engineering › Compressed Air System (control) › Compressor
Issued 29 December 2016
Resolved
Repair fluid leak on port air compressor in lazarette.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 January 2017
Resolved 18 January 2017
Fire Fighting › Means of Escape › Blocked
Issued 29 December 2016
Resolved
Adjust starboard upper dog of the forward escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2017
Resolved 18 January 2017
Engineering › Bilge Water Management System › Strainer
Issued 29 December 2016
Resolved
Passenger Compt: clean AC unit debris from bilge & remove deteriorating debris from AC units.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2017
Resolved 18 January 2017