MAURY USCG vessel records Sign in
← All vessels

FORTUNE

FORTUNE is a 1975 freight ship. The Coast Guard has recorded 35 inspections since 1999, most recently in February 2024, along with 63 deficiencies and 17 operational controls.

Records from 1999 to 2024. Most recent: inspection, 5 February 2024.

Built
1975
Last inspected
5 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7420948 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5U2089
499940
Flag
COOK ISLANDS
—
Maury page id
psix-499940

Inspections, by type

…with no type recorded28
Years with a record 9 calendar years (1999–2024)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it959 - Convention (Subpart B), Gross Ton
520 - Convention (Subpart B), Net Ton
1511 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

5 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860922
22 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3349484
12 April 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3183652
10 April 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3181133
22 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3151928
10 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3113678
9 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3112262
23 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3084381
23 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3085849
22 September 2007 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3054041
7 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3051931
10 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2708097
7 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2704268
2 May 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2638585
28 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2635643
28 March 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2611084
26 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2609687
2 March 2006 ILO-147 Exam · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2594478
1 March 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2594678
28 February 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2593507
16 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2493717
11 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2489298
29 July 2005 Ballast Water Examination · ISPS I Exam · Deficiency Check · MARPOL Annex I Examination · PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2443888
27 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2441995
27 June 2005 ISPS I Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2404532
23 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2399809
17 April 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1775407
1 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 289688
22 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 732608
21 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 288384
23 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 12591
23 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 286064
1 May 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 277469
23 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 275165
15 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 732607

Deficiency record · 63

Operations/Management › Drills/Instruction › Fire
Issued 10 September 2007 Resolved
Performed unsatisfactory fire drill due to lack of crew on board. Request vessel conducts daily drills and contact Sector Miami when drills satisfactory.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 21 September 2007
Resolution: Crew performed a satisfactory fire and abandon ship drill.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 10 September 2007 Resolved
When chief mate reports on board request vessel fax licenses to Sector Miami.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 22 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 10 September 2007 Resolved
No chart corrections log book on bridge.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 21 September 2007
Resolution: Chart correction log book was filled out properly and maintained.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 September 2007 Resolved
Starboard side generator and air compressor are missing shroud over belts. Replace prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 September 2007 Resolved
Oily water separator is inop. Request vessel repair or remove and fax report to Sector Miami.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 21 September 2007
Resolution: OWS operates properly.
Communications › Internal Communications System › Portable Radios
Issued 10 September 2007 Resolved
Vsl needs communications between bridge and steering
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 21 September 2007
Resolution: Vsl is equipped with adequate hand held radios.
Deck/Cargo › Marine Portable Tanks › Securing Device
Issued 10 September 2007 Resolved
Torch bottles on deck need to be properly stowed.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 21 September 2007
Resolution: Torch bottles were removed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 September 2007 Resolved
Personnel need to police engine room for excess debris
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 21 September 2007
Resolution: Engine room was in satisfactory condition.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 10 September 2007 Resolved
Need to fumigate entire vessel for roaches.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 5 February 2024
Resolution: Clearing old def from activity # 3054041. Vessel was allowed to depart and came back into port on a separate occasion. Cleaning up old misle cases vessel has not been back to U.S since 2008 and last AIS update was in 2015.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 September 2007 Resolved
OWS did not have alarm according to IOPP certificate.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2007
Resolved 21 September 2007
Resolution: IOPP certificate was not accurate. Flag State corrected error on IOPP, OWS is not required to be equipped with an alarm.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 September 2007 Resolved
Oil Pollution Placard was missing in engine room.
Due 21 September 2007
Resolved 21 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 2 March 2006 Resolved
Vessels charts are out of date update all charts onboard and correct using notice to mariners.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Lifesaving › Hand Flares › Quantity
Issued 2 March 2006 Resolved
Vessel is missing one flare on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Fire Fighting › Nozzles › Location
Issued 2 March 2006 Resolved
Vessel is missing a nozzle for the fire hose in the engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 March 2006 Resolved
Vessel is missing fire plans on port and starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 March 2006 Resolved
One lifejacket on the bridge is missing light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Communications › Radio Communications › Emergency Source of Power
Issued 2 March 2006 Resolved
Secure batteries in box for GMDSS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 January 2006 Resolved
33U.S.C.1321(j)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(D)(ii)-The NTVRP does not provide 24-hour contract information for the qualified individual, or indicate that the qualified individual will have immediate contact with the NRC.
Due 25 February 2006
Resolved 15 January 2009
Resolution: NTVRP plan #03503 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 January 2006 Resolved
33U.S.C.1321(j)(D)(i)-The NTVRP does not clearly identify the vessel's intended areas of operation/COTP zones. In addition, it does not include the volume and type of oil that would be involved in a worst case discharge. 33U.S.C.1321(j)D)(iv)-The NTVRP does not address training as well as all applicable drill/exercise frequencies.
Due 25 February 2006
Resolved 15 January 2009
Resolution: NTVRP plan #03503 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 29 July 2005 Resolved
Vsl has a gasoline emergency fire pump. The aministration needs to address to the fire pump.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2005
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 29 July 2005 Resolved
Fire Main pipeing wasted and holed fix prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2005
Construction/Loadline › Structures › Deck Plating
Issued 29 July 2005 Resolved
Vessel has wooden deck with steel underneath both are wasted and need to be addressed by the administration
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2005
Resolved 29 July 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 27 June 2005 Resolved
Current flag state has not issued safe manning certificate.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 28 June 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 27 June 2005 Resolved
Vessel is not manned in accordence with safe manning document. Vessel is missing one officer in charge of Navigation.
Action required: 15 - Rectify deficiencies by next port
Resolved 29 July 2005
Lifesaving › Rescue Boat › Propulsion Engine
Issued 27 June 2005 Resolved
Rescue boat engine is inoperable and can not be used for rescue.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2005
Communications › Radio Communications › Satellite Communications Capability
Issued 27 June 2005 Resolved
GMDSS is inoperable and crew cannot send distress signal.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2005
Communications › Radio Communications › EPIRB
Issued 27 June 2005 Resolved
EPIRB not registered with current MMSI number. Vessel not reconizable to search and rescue centers.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2005
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 June 2005 Resolved
Magnetic compass deviation table is overdue.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 June 2005 Resolved
Emergency generator has exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 June 2005 Resolved
Paint stored in eergency generator space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 July 2005
Resolved 29 July 2005
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 21 March 2001 Resolved
Provide valid documents for oiler in IAW Safe Manning Document. [name withheld] indicated 05 AB Seaman on board; Safe Manning requires 02 AB, 02 OS, and 01Oiler.
Condition: Unknown
Due 21 March 2001
Resolved 27 June 2005
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 21 March 2001 Resolved
Provide valid documents/licenses for Chief Engineer. Had no valid licenseson board.
Condition: Unknown
Due 21 March 2001
Resolved 27 June 2005
Documentation › Certificates/Documents › IOPP Certificate
Issued 21 March 2001 Resolved
Provide all expired certificates as valid: Safety Construction Certificate,Safety Equipment Certificate, Safety Radio Certificate, IOPP.
Condition: Unknown
Due 21 March 2001
Resolved 27 June 2005
Documentation
Issued 23 February 2001 Resolved
Provide a valid Certificate of Responsibility while in U.S. waters.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Documentation
Issued 23 February 2001 Resolved
Commence logging of lifesaving and firefighting equipment in log book.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Documentation
Issued 23 February 2001 Resolved
Man ship in accordance with safe manning document.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Documentation
Issued 23 February 2001 Resolved
Commence logging receipts in garbage log.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Engineering
Issued 23 February 2001 Resolved
Install guards around all rotating machinery in engine room.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Accommodation/Occupational Safety
Issued 23 February 2001 Resolved
Repair latching mechanism for engine room door from accomodation spaces.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 23 February 2001 Resolved
Repair all lighting in accomodation spaces.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Navigation
Issued 23 February 2001 Resolved
Prove proper operation of GMDSS by crew.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Navigation
Issued 23 February 2001 Resolved
Prove proper operation of both installed radars.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Navigation
Issued 23 February 2001 Resolved
Provide corrected charts and pubs.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Accommodation/Occupational Safety
Issued 23 February 2001 Resolved
Remove all flammables from accomodation spaces.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Accommodation/Occupational Safety
Issued 23 February 2001 Resolved
Repair hand rail for portside ladder.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Construction/Loadline
Issued 23 February 2001 Resolved
Repair starboard hause pipe inway of emergency fire pump room.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Lifesaving
Issued 23 February 2001 Resolved
Repair/replace aft bouy light, aft of galley.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 23 February 2001 Resolved
Provide all portable fire extinguishers onboard.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 23 February 2001 Resolved
Provide nuts/bolts/gaskets and fasteners for the international shore connection.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 23 February 2001 Resolved
Conduct satisfactory fire and abandonship drills in presence of U.S. Coastguard.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Documentation
Issued 23 February 2001 Resolved
Have PIC sign oil record book IAW established guidelines.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Documentation
Issued 23 February 2001 Resolved
Have SOPEP approved by Flag State/Class Society.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 23 February 2001 Resolved
Properly secure starting battery for starboard generator in engine room.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 23 February 2001 Resolved
Repair fuel oil leaks on port and starboard generators.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 23 February 2001 Resolved
Repair exhaust leak on emergency generator.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Unknown
Issued 23 February 2001 Resolved
Have class provide a report attesting to completion of all items prior to scheduling a continuing Coast Guard exam.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2001 Resolved
Have CLASS address the hull doubler patch mentioned in ships log JAN 06 2001.
Condition: Unknown
Due 14 March 2001
Resolved 27 June 2005
Electrical
Issued 23 February 2001 Resolved
Repair electrical outlet switch at entrance of emergency generator room.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Documentation
Issued 23 February 2001 Resolved
Revise Oil Transfer Procedures.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Documentation
Issued 23 February 2001 Resolved
Provide medical certificates for all crew.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Unknown
Issued 23 February 2001 Resolved
Have CLASS adress all "prior to departure" items and FAX report to MSO Miami, prior to next inspection.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 23 February 2001 Resolved
Repair Main Generator (portside) to satisfaction of class.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Unknown
Issued 23 February 2001 Resolved
Correct/address all prior discrepancies from 24JAN01 boarding report.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.