MAURY USCG vessel records Sign in
← All vessels

W-O HANHAN

W-O HANHAN is a 1998 tank ship. The Coast Guard has recorded 38 inspections since 1999, most recently in July 2007, along with 23 deficiencies — 1 with no resolution recorded — and 14 operational controls.

Records from 1999 to 2007. Most recent: operational control imposed, 21 July 2007.

Built
1998
Last inspected
21 July 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9183477 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
499962
Flag
MARSHALL ISLANDS
—
Maury page id
psix-499962

Inspections, by type

…with no type recorded25
…past their stated due date1
Years with a record 9 calendar years (1999–2007)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9419 - Convention (Subpart B), Gross Ton
4957 - Convention (Subpart B), Net Ton
15389 - Dead Weight, Ton
19781 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

21 July 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3002283
14 July 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2994328
18 January 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2857924
5 January 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2850647
18 September 2006 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2780999
14 June 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2685632
31 May 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2666743
5 March 2006 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2596194
1 March 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2593862
15 February 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2585984
11 December 2005 MARPOL Annex V Examination · Deficiency Check · MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2549260
9 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2549089
25 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2543516
23 November 2005 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2539728
23 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2582328
19 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2467874
19 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2467955
8 August 2005 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2455803
7 August 2005 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2449213
2 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2452372
27 October 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2228778
5 October 2004 ISPS II Exam · COC-CHEM Renew
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2214352
26 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1801835
12 February 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1743556
8 February 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1741750
4 February 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1739794
30 January 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1737688
27 January 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1735679
14 November 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1705568
18 March 2002 In-Service Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1494524
7 December 2001 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 296003
15 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286001
10 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 86487
9 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283086
3 July 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 279591
1 February 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274254
11 October 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 433482
11 October 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1121090

Deficiency record · 23

Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 January 2007 No resolution recorded
The vessel is missing 1 of 2 anchors required. Vessel was required a tug assist while in the COTP zone as well as to provide a report attesting to the proper replacement of the anchor from the Classification Society.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2007 — due date passed with no resolution recorded
Resolution: Class report recieved attesting to proper installation of the port anchor. Operational Control is lifted. 01 def issued, 01 def cleared, 00 def remain.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 September 2006 Resolved
Galley class A--60 Fire door was equipped with a holdback.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Resolution: Holdback was removed deficiency cleared while inspectors were still onboard.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 September 2006 Resolved
Fire doors located in the vessel's main ladder on A and B decks did not close properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Resolution: Vessel repaired fire doors will inspectors were still on board
Lifesaving › Lifeboat › Propulsion Engine
Issued 18 September 2006 Resolved
Lifeboat engine failed to start.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Resolution: Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 March 2006 Resolved
Vsl suffered damage to mooring equipment and had rails during mooring operations. Port side bitt used to tie off line was sheared off its base. Class must asses damage prior to the vsl's departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Resolution: Recieved damage assessment from class. Minor damage sustained due to incident must be repaired prior to 19 MAY 06 as chemical and petroleum cargoes are currently on board. Temporary measures have been made to ensure the crew members safety.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 23 November 2005 Resolved
Vessel's forward eyewash station broke when conducting test. Vessel must repair valve within (14) days to the satisfaction of the Coast Guard. Cite 46 CFR 153.216.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 11 December 2005
Resolution: Cleared deficiency to the satisfaction of Coast Guard Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 2 August 2005 Resolved
Vessel's MAIN ENGINE INCAPABLE OF ACHIEVING 100% PROPULSION prior to entering port. Inbound Deviation was granted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2005
Resolution: Received technicians report attesting to satisfactory repairs.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 October 2004 Resolved
PERMANENT STUDS ON FLANGES MISSING.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 October 2004
Resolution: During inspection found that the studs on the VCS flanges had been installed.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 5 October 2004 Resolved
Oil discharge monitoring equipment is inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 October 2004
Resolution: Received fax copy of technician repair report.
Operations/Management › Pollution › Control of Garbage
Issued 5 October 2004 Resolved
Dispose of garbade to US Facility prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2004
Resolution: Received fax reciept of garbage disposal.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 October 2004 Resolved
Garbage log book provided only ten months of log entries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 October 2004
Resolution: Received fax copy of class survey and SMS Company Circular.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 October 2004 Resolved
Missing Navigation Rules of the Road Publication. Provide fax reciept prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2004
Resolution: Received fax reciept showing vessel received publication.
Documentation › Certificates/Documents › Certificate of Fitness (BCH Code)
Issued 5 October 2004 Resolved
Upon expiration of Certificate of Fitness provide fax copy of new Certificate of Fitness at next US Port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2004
Resolution: Received fax copy of new certificate of fitness.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 8 February 2003 Resolved
Vsl Request inbound/outbound deviation for port Anchor. Inbound deviation was granted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2003
Resolved 8 February 2003
Resolution: Rcvd class report attesting to replacement of the port anchor. Vsl was cleared to sail.
Deck/Cargo › Mooring/Anchoring
Issued 30 January 2003 Resolved
Vessel reported missing anchor. Inbound deviation granted. (33CFR164.11) Replaced missing anchor. LEGACY COMPONENT DESC: Anchor
Action required: 705 - Other - as specified
Due 30 January 2003
Resolved 9 February 2003
Resolution: Rcvd class report attesting to repairs of anchor.
Fire Fighting › Miscellaneous Items
Issued 7 December 2001 Resolved
Provide training manual for fire fighting.
Condition: Unknown
Due 7 January 2002
Resolved 18 March 2002
Resolution: Deficiency corrected.
Deck/Cargo › Holds/Tanks
Issued 7 December 2001 Resolved
Overfill for #10 stbd tank inoperable. Upon discharging and cleaning repair system to satisfaction of USCG Marine Inspector. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Condition: Unknown
Due 7 January 2002
Resolved 18 March 2002
Resolution: Vessel made required repairs to the #10 stbd tank overfill alarm and demonstrated satisfactory operation to the satisfaction of the attending Coast Guard marine inspector.
Lifesaving
Issued 7 December 2001 Resolved
Repair/Replace two broken oxygen meters. Fax receipt to COTP Baltimore.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Fire Fighting
Issued 9 October 2000 Resolved
ENSURE PROPER OPERATION OF FIRE DAMPER PORT AND STARBOARD LOWER DECK IN ENGINE ROOM. _x001C_ SOLAS 74 II-2/16
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Electrical
Issued 9 October 2000 Resolved
PLACE ELECTRICAL WIRE THROUGH CABLE RUN IN FORWARD BOS'N HOLE._x001C_ SOLAS 74 II-1/45
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Deck/Cargo
Issued 11 October 1999 Resolved
REPLACE ROTATIONG LIGHT FOR TELEPHONE IN PUMPROOM.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Deck/Cargo
Issued 11 October 1999 Resolved
REPLACE COVER ON PRESSURE SWITCH IN PUMPROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Deck/Cargo
Issued 11 October 1999 Resolved
REPAIR/REPLACE VENT SCREENS ON ALL BALLAST TANK VENTS.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.