MAURY USCG vessel records Sign in
← All vessels

ORIENT CARP

ORIENT CARP is a 1999 freight ship. The Coast Guard has recorded 20 inspections since 2000, most recently in October 2008, along with 5 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2000 to 2008. Most recent: inspection, 27 October 2008.

Built
1999
Last inspected
27 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9172387 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
499963
Flag
PANAMA
—
Maury page id
psix-499963

Inspections, by type

…with no type recorded8
Years with a record 9 calendar years (2000–2008)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it20947 - Convention (Subpart B), Gross Ton
11740 - Convention (Subpart B), Net Ton
42108 - Displacement, Ton
35366 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

27 October 2008 NPV Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3348649
20 May 2008 PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3205686
18 May 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3209370
7 December 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3111500
7 March 2007 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2882990
12 October 2006 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798547
26 April 2005 MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2342978
16 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2335226
8 November 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2237389
6 November 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2236061
11 July 2004 PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2128627
7 July 2004 ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2125028
29 January 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1996998
26 January 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1991600
19 August 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1880881
3 March 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1752137
22 June 2002 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1635435
30 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 295166
5 February 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286773
17 July 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 280072

Deficiency record · 5

Navigation › Collision/Grounding Avoidance › Radar
Issued 20 May 2008 Resolved
Master reported that the X band radar was not operating. During the exam the PSCO did find the radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2008
Resolved 21 May 2008
Resolution: Received tech report satisfying requirements.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 October 2006 Resolved
During the record keeping portion of the port state control examination it was found that the garbage logbook had numerous reporting mistakes and inconsistencies annotated that did not comply with 33 CFR 151.55. Repair to the satisfaction of the Coast Guard Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 October 2006
Resolved 7 March 2007
Resolution: Conducted PSC exam, Garbage Record Book was filled out properly.
Electrical › Lighting (service)
Issued 26 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 February 2004
Resolved 29 January 2004
Engineering › Freshwater Generation System
Issued 3 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 19 August 2003
Resolution: Recieved a report from class as requested and Defiencies have been cleared. [name withheld]
Engineering › Feedwater/Condensate Water System
Issued 3 March 2003 Resolved
SALTWATER OUTLET PIPE FOR CASCADE TANK COOLER HAS A SOFT PATCH . LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 19 August 2003
Resolution: Recieved class report as requested and deficiencies have been cleared.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.